Engineering PapersSearch

SEARCH · Engineering Papers

Results for “can side wall rupture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

539 records · Page 2

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter

Ferroelectric Fractals: Switching Mechanism of Wurtzite AlN

The advent of wurtzite ferroelectrics is enabling new ferroelectric devices for computer memory that have the potential to bypass the von Neumann bottleneck due to their robust polarization and silicon compatibility. However, the atomistic switching mechanism of wurtzites is still undetermined due to the limitations of density functional theory simulation size and experimental temporal and spatial resolution. Thus, physics-informed materials engineering to reduce coercive field and breakdown in these devices has been limited. In this work, the atomistic mechanism of domain wall migration and domain growth in aluminum nitride-based wurtzites is uncovered using molecular dynamics and Monte Carlo simulations. We reveal the anomalous switching mechanism of fast 1D single columns of atoms propagating from a slow-moving 2D fractallike domain wall. We find that the critical nucleus is a single aluminum ion that breaks its bond with one nitrogen and bonds to another nitrogen; this creates a cascade that flips atoms directly only in the same column, due to the extreme locality (sharpness) of the domain walls in wurtzites. We further show how the fractallike shape of the domain wall in the 2D plane breaks assumptions in the Kolmogorov, Avrami, and Ishibashi (KAI) model and leads to the anomalously fast switching in wurtzite structured ferroelectrics.

36 MATERIALS SCIENCE

Integrated Magnetics for Multiport Inductive and Conductive Power Transfer Architecture for Electric Vehicles

This paper proposes a shared magnetic arrangement for an electric-vehicle charger that supports both conductive and inductive charging while preserving independent power control at the two ports. In the proposed implementation, the high-frequency transformer used for the conductive path and the resonant inductor required by the inductive path are realized in an integrated form. By combining the magnetic structure and primary-side converter hardware, the charger can deliver improved hardware utilization and higher power density without a corresponding increase in cost or implementation complexity. The paper describes the magnetic realization and presents finite-element and circuit-level simulation results to confirm minimal interaction between the two charging paths. The study demonstrates that the proposed charger is a viable option for flexible, high-power EV charging systems.

Mukherjee, Subho [ORNL] (ORCID:0009000672297925)

Activation dynamics of a water-soluble human mu-opioid receptor

The mu-opioid receptor (MOR), a class A G protein-coupled receptor mediates opioid analgesia and remains a central target for pain therapeutics. While crystal structures of MOR exist, they provide limited insight into the receptor’s dynamic conformational landscape underlying function. Here, we engineered a thermostable water-soluble MOR variant (wsMOR) that retains native-like ligand-binding and activation dynamics. This variant enables high-yield production and detailed solution-phase structural studies that are challenging with membrane-embedded MOR, providing a valuable tool for studying receptor activation and aqueous-phase drug screening. Using a combined computational and experimental approach, we performed long-timescale all-atom molecular dynamics simulations together with neutron scattering and single-molecule FRET, revealing a structurally stable receptor with a diverse ensemble of conformations at different temporal resolutions. In the ligand-free state, wsMOR displayed high conformational flexibility, which decreased upon agonist binding, particularly in transmembrane helix 6, a hallmark of G protein-coupled receptor activation. Positive allosteric modulation and G protein binding further stabilized active-like states. These findings highlight wsMOR’s conformational plasticity across picosecond to millisecond timescales and provide a foundation for structure-guided development of next-generation opioid ligands with improved efficacy and safety.

E, Agyemang [University of Tennessee Knoxville]

Power and particle exhaust in the ST-E1 fusion power plant

Power exhaust challenges and potential solutions for a 5 m major radius, low-aspect ratio burning tokamak have been explored. 1D edge plasma models have been used to screen for access to detachment using short and long outer divertor legs in double and single null configurations, using Ar as the primary impurity and assuming tungsten plasma-facing components (PFCs). These show that detachment access can be accessed for all but the most conservative assumptions on scrape-off layer (SOL) width and power, but that trade-offs will be required between magnet engineering and the size of the acceptable window of as-yet uncertain plasma parameters. SOLPS-ITER was used to further model selected plasma scenarios, confirming that Ar seeding can be used to achieve dissipative divertor scenarios with peak deposited heat fluxes below 15 MWm -2 . Initial scoping of first wall loads and positioning of limiters has been carried out, showing the feasibility of protecting the breeding blanket wall during steady state without impeding tritium breeding. Initial PFC technology selection is also presented, identifying this as a critical area where further work is needed to find an attractive solution for helium-cooled PFCs that can handle high heat fluxes without excessive power requirements. Key questions and trade-offs for concept development have been identified, including: how to achieve high radiation for reduction of SOL power without core performance degradation; whether power exhaust can be well-controlled in a double null plasma; mechanical design and materials challenges of high-heat flux PFCs; and control of material erosion, redeposition and tritium retention.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

In situ electric field X-ray total scattering reveals composition-dependent electromechanical strain mechanisms in (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 ceramics

Ferroelectric materials find many applications in energy and aerospace industries. A major challenge for ferroelectric materials is maintaining their properties at elevated temperatures. The (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 (BFTM–xPT) ferroelectric solid solution is a promising candidate for high-temperature applications as it has a high piezoelectric response while also maintaining its ferroelectric phase until a high Curie temperature (T C ) of 650 °C. In this work, we investigate the piezoelectric mechanism in BFTM–xPT, a novel high-T C ferroelectric ceramic. To elucidate the origin of its enhanced piezoelectric performance, relative to other piezoceramics of similar T C , in situ electric field X-ray total scattering experiments were performed. Total scattering combines Bragg scattering (diffraction) and diffuse scattering (pair distribution function), providing insight on various length scales. With information spanning different length scales, extrinsic contributions (i.e., domain wall motion and interphase boundary motion) can be separated from intrinsic contributions (i.e., piezoelectric lattice strain). We show that, for compositions within the morphotropic phase boundary (MPB, x = 0.325), the piezoelectric response is dominated by intrinsic piezoelectric lattice strain, whereas outside the MPB (x = 0.375) the major component of the piezoelectric response is from extrinsic mechanisms including an electric-field-induced phase transition and tetragonal domain wall motion. This article reveals that the origin of piezoelectric response in BFTM–xPT is composition-dependent and shows that high-performance materials may also be located outside the MPB. These findings can help guide material design to optimize properties for specific applications.

Richtik, Brooke N. [University of Calgary, AB (Can

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Experimental investigation of a closed vapour box module for a divertor-like configuration in Magnum-PSI

Efficient management of extreme heat fluxes in the divertor region to extend the lifetime of the components remains a critical challenge for the realization of nuclear fusion-based power plants. Among the alternative concepts explored for the divertor region, the use of liquid metals, particularly lithium, is of interest due its ability to dissipate the incoming plasma heat flux through the vapour shielding effect (VS). In this work, we experimentally investigated a ‘closed’ configuration of a dedicated Vapour Box Module (VBM) in the linear plasma device Magnum-PSI. The goal of the experiments is to simulate the vapour box divertor environment conditions and assess its performance in terms of power mitigation and redistribution and lithium confinement. Initial testing without Li demonstrated the efficacy of a closed VBM structure in inducing detachment via neutral gas accumulation. Apertures which enabled non-condensing gas to be effectively pumped while ensuring lithium condensed on the inner surfaces were therefore added. With a lithium capillary porous structure target used, lithium is directly vaporized by the plasma, forming a dense lithium vapour cloud that interacts with the incoming plasma. This resulted in a significant reduction of the target temperature of at least 48%, together with a temperature locking effect, a phenomenon typically observed in the VS regime. Lithium vapour confinement within the VBM was strongly correlated with the wall temperature. Relatively cold walls promoted Li re-condensation and therefore improved Li confinement, although with the expected trade-off of increased hydrogenic retention on lithium-wetted surfaces. As the wall temperature increased, the confinement efficiency decreased, consistent with reduced Li re-condensation and thermally activated Li–H chemistry and remobilization at the walls. Diagnostic measurements through embedded thermocouples and calorimetry revealed that lithium vaporization and re-condensation processes also playedsignificant roles in plasma power dissipation. The results advance the case for a closed divertor chamber with direct lithium evaporation from the strike-points as a viable method to manage divertor heat fluxes in future fusion reactors.

Romano, Fabio [Dutch Institute for Fundamental Ene

Robust Heat-Flux Sensors for Coal-Fired Boiler Extreme Environments

In this project, robust heat-flux measurement systems were developed. The heat-flux sensors utilize thermoelectric effects to directly transduce the heat-flux inputs to analog electrical voltage signals. They were constructed from dedicated materials that can withstand temperatures of at least 1000°C and maintain adequate performance at these conditions for prolonged periods of time. The proposed approaches took into account numerous considerations, including system cost, sensor head resilience, sensor footprint, data accuracy, response time, and maintenance requirements. Through modern thermoelectric materials design, methodical materials selection and rigorous testing in materials characterization labs and medium-scale fire research facilities, we have demonstrated functioning laboratory prototypes, upon which one could base industrial heat-flux sensing platforms capable of operating in the challenging high-temperature, corrosive environments of the boilers of coal-fired power plants. A distributed sensor array for heat-flux measurements throughout the furnace water-wall, the superheater area and the economizer coils can provide critical data for the power plant control systems to increase efficiency, improve safety and reduce down times. For example, the combined heat-flux sensor/control systems can contribute to the optimization of burner and boiler operations under flexible loads, the optimization of heat-exchange conditions and overall reduction of heat rate and emissions, the prediction of imminent overheating conditions, and the optimization of the soot-blowing protocols.

20 FOSSIL-FUELED POWER PLANTS

Factors Influencing Gas Evolution from High‐Nickel Layered Oxide Cathodes in Lithium‐Based Batteries

Abstract Gas evolution from high‐nickel layered oxide cathodes (>90% Ni) remains a major issue for their practical application. Gaseous species, such as CO 2 , O 2 , and CO, that are evolved at high states of charge (SOC) worsen the overall safety of batteries, as pressure build‐up within the cell may lead to cell rupture. Since these gasses are produced during cathode degradation, tracking the formation of gasses is also important in diagnosing cathode failure. Online electrochemical mass spectrometry (OEMS) is a powerful in situ technique to study gas evolution from the cathode during high‐voltage charge. However, the differences in the OEMS experimental setups between different groups make it challenging to compare results between groups. In this perspective, the various factors that influence gas evolution based on the OEMS results collected in this group are presented. The focus is on the conditions that lead to gas release, with a particular emphasis on reactive oxygen formation and subsequent chemical reactions with the electrolyte. Promising strategies, such as electrolytes, compositional tuning, and surface coatings that are effective at suppressing gas evolution from the cathode are highlighted. Critical insights into mitigating cathode degradation and gas evolution are provided to guide the development of safer, high‐energy batteries.

Chemistry

India Power Sector Reliability Analysis [Slides]

The objective of the study is to assess pathways for India to achieve its 2070 power sector goals reliably and cost-effectively by considering various supply- and demand-side factors to support planning by national stakeholders including the Central Electricity Authority (CEA).

08 HYDROGEN

Design and fabrication of ion traps for low RF power dissipation

Large surface-electrode ion traps with multiple trapping regions and junctions are a natural approach to scaling trapped ion quantum computers, supporting the connectivity and ion counts necessary for complex quantum algorithms. However, a major hurdle in this scaling is on-chip power dissipation from the applied RF voltage, which increases at a rate between linear and cubic relative to trap size, depending on whether the losses are dielectric or Ohmic. Here, we present two versions of a trap with features designed to reduce both types of RF power dissipation. The first variant contains a raised RF electrode that increases the electrode–ground distance to reduce capacitance. Different DC voltage sources are demonstrated on this trap to show that technical noise before the filter remains the dominant source of voltage noise and therefore motional heating. The second variant additionally includes a method for removing dielectric from beneath the RF electrode to further reduce dielectric losses. These traps were demonstrated at room temperature with 40 Ca + ions. In conclusion, the similar heating rates and heating rate axial frequency dependencies between 2.4 and 3.0 MHz illustrate that this dielectric modification is not detrimental to trap performance.

Sterk, J. D. [Sandia National Laboratories (SNL-NM

Optimizing Porous Transport Layer Porosity for Proton Exchange Membrane Water Electrolysis

An empirical model is presented that describes anode-side losses related to porous transport layer (PTL) morphology in proton exchange membrane water electrolysis (PEMWE). The model is based on an advanced voltage breakdown analysis that links various overpotentials to PTL morphology. Custom Ti PTLs, spanning uncommonly low porosities (22 - 31%), were fabricated and analyzed with X-ray CT to obtain pore and particle size distributions. Particle size distributions were consistent across samples with an average particle diameter of 12.0?..mu..m, whereas average pore diameters ranged from 6.0 to 7.0?..mu..m. The PTLs were tested in standard PEMWE cell assemblies with anode catalyst loadings of 0.1 mgIr cm-2 to obtain polarization curves, electrochemical impedance spectra, and augmented Tafel analysis. The PTL-dependent anode side losses were deconvoluted and assigned to excess utilization, concentration, ion transport resistance, and electrical contact resistance overpotentials. The data and model reveal an optimal 20 - 28% PTL porosity region where utilization and contact resistance overpotentials are minimized without triggering concentration and ion transport losses related to water deprivation. The optimal PTL porosity depends on the operating current density and is demonstrated at realistic PEMWE water flow rates to establish PTL design guidance for operation at scale.

08 HYDROGEN

Mechanochemically responsive polymer enables shockwave visualization

Abstract Understanding the physical and chemical response of materials to impulsive deformation is crucial for applications ranging from soft robotic locomotion to space exploration to seismology. However, investigating material properties at extreme strain rates remains challenging due to temporal and spatial resolution limitations. Combining high-strain-rate testing with mechanochemistry encodes the molecular-level deformation within the material itself, thus enabling the direct quantification of the material response. Here, we demonstrate a mechanophore-functionalized block copolymer that self-reports energy dissipation mechanisms, such as bond rupture and acoustic wave dissipation, in response to high-strain-rate impacts. A microprojectile accelerated towards the polymer permanently deforms the material at a shallow depth. At intersonic velocities, the polymer reports significant subsurface energy absorption due to shockwave attenuation, a mechanism traditionally considered negligible compared to plasticity and not well explored in polymers. The acoustic wave velocity of the material is directly recovered from the mechanochemically-activated subsurface volume recorded in the material, which is validated by simulations, theory, and acoustic measurements. This integration of mechanochemistry with microballistic testing enables characterization of high-strain-rate mechanical properties and elucidates important insights applicable to nanomaterials, particle-reinforced composites, and biocompatible polymers.

Science & Technology - Other Topics

Characterization of Flashback and Flame-Holding in a Jet-in-Crossflow Mixing Configuration With Methane–Hydrogen Fuel Blends

An approach that combines experimental and numerical analyses has been implemented to characterize the fundamentals of flashback events and flame-holding phenomena during high-hydrogen combustion in a jet-in-crossflow (JICF) configuration. Such flame dynamics are visualized experimentally using nanosecond (ns)-based hydroxyl planar laser-induced fluorescence (OH-PLIF) and chemiluminescence diagnostics techniques. The JICF burner has an optically accessible premixing tube allowing the optical diagnostics. The testing was conducted for varied premixer velocities (V) and equivalence ratio (ϕ) for 90–100% (H 2 , by mole) H 2 /CH 4 reactant mixtures at atmospheric temperature and pressure conditions. Two distinct flashback events were identified – conventional rich flashback and lean flashback, recorded while increasing ϕ and decreasing ϕ, respectively. The cause of lean flashback was attributed to lower momentum flux ratio which bends the jet sharply, closer toward the injection plane. The mean OH-PLIF images characterized the flame-holding behavior, where the flame was found to be stabilized on the leeward side only or on both windward and leeward sides as a lifted flame near the fuel port. A large eddy simulation (LES) with detailed chemistry combustion modeling approach was implemented along with an OH* submechanism, and it showed qualitative agreement with the integrated line-of-sight chemiluminescence results as well as the planar OH-PLIF measurements.

chemiluminescence diagnostic

Evaluating Fracture Behavior of Bioinspired Alumina-YSZ Composites through Static and Dynamic Mechanical Testing

Ceramic materials are known for their high hardness and strength but are limited by low toughness and sudden failure. Inspired by the microstructure of dental enamel, which features undulating rods that promote crack deflection and energy absorption, architected specimens were designed and manufactured. A bespoke ball-on-ring (BoR) testing apparatus measured the static biaxial rupture strength of these bioinspired materials. Additionally, impact testing with spherical steel projectiles assessed their behavior under dynamic conditions. Monolithic alumina specimens were compared to architected alumina reinforced with yttria-stabilized zirconia (YSZ) rods produced via direct ink write 3D printing. BoR tests revealed that monolithic alumina had a Weibull modulus of 10.53 and a characteristic strength of 372.3 MPa, while the composite specimens showed a Weibull modulus of 5.46 and a characteristic strength of 213.3 MPa. Although the composite failed at lower stresses and projectile velocities, it exhibited notable crack deflection and fracture resistance, with cracks being effectively interrupted by the rod inclusions. The composite specimens also resulted in fewer and larger fragments upon impact. Finite element simulations confirmed the effectiveness of the rod structures in enhancing fracture resistance.

Bioinspired materials

Direct regeneration of degraded LiFePO4 cathodes via a separator-enabled prelithiation strategy

A persistent challenge in lithium-ion batteries is the loss of active lithium due to the solid electrolyte interphase (SEI) formation and associated side reactions. While prelithiation employing lithium replenishment separator (LRS) has been proven effective in compensating for lithium loss, previous studies have largely been accompanied by gas evolution or solid residue formation during the prelithiation process. To surmount this challenge, we present a LRS based on 4-fluoro-1,2-dihydroxybenzene lithium salt (LiDF), capable of mitigating lithium loss while producing decomposition products that integrate directly into the electrolyte as functional additives which can assist with the stability of the SEI, free from gas or solid formation, thus establishing a sustainable and environmentally benign strategy for lithium compensation. Incorporation of the LRS enables the pristine LiFePO4||graphite (Gr) full cell to achieve 10.8% higher capacity than the cell with a polypropylene separator (PPS) after 200 cycles at 0.5C. Remarkably, the degraded LiFePO4 (D-LFP)||Gr full cell with the LRS exhibits a 135.8% capacity improvement over the PPS-based cell after 500 cycles. These findings establish the LRS as a powerful approach for both boosting high-performance lithium-ion batteries and recovering the capacity of degraded batteries.

Tao, Fujun

An Analysis of Energy Needs and Seawater Extraction Approaches for the Integration of Primary Magnesium Production with Nuclear Power

The cost of primary magnesium production is highly dominated by the energy required to produce the metal. This, along with the current geographical concentration of its production, makes the magnesium price vulnerable as energy-production paradigms begin to rapidly change. In this work, four nuclear-integration pathways for the efficient supply of heat and electricity to magnesium production from a nuclear power plant are considered. A production route using electrified metallothermic reduction is compared to a nuclear-heat-integrated electrolytic pathway. It is shown that the latter can achieve significantly lower primary energy consumption, 261 MJ/kg Mg compared with 416 MJ/kg Mg. The electrolytic pathway can also reduce emissions down to around 2.1 kgCO2/kg Mg, compared to around 34 kgCO2/kg Mg in the Pidgeon process. Beyond energy and emissions, the four pathways considered are also compared to their ability to reduce locational dependence of the production plant and reduce process complexity. This work also highlights future advances in magnesium production with a potential scheme for the efficient extraction of magnesium from seawater with coproduction of desalinated water and the potential of demand-side response from magnesium electrolysis. This is the first work to consider the full integration of primary magnesium production using nuclear cogeneration, and it is hoped the study paves the way for the analysis of economic nuclear integration within metal extraction and manufacturing.

22 - GENERAL STUDIES OF NUCLEAR REACTORS