Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beta counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Identification and quantification of distinct active sites in Hf-Beta zeolites for transfer hydrogenation catalysis

Despite the significant progress made in characterizing different framework heteroatom sites that exist in Lewis acidic zeolites with probe molecule adsorption and spectroscopy, methods to reliably quantify site counts remain indefinite and have been primarily limited to Sn and Ti Lewis acid sites. Here, methods to quantify framework Lewis acidic Hf 4+ sites in zeolite Beta (Hf-Beta) with two Lewis base titrants (pyridine, deuterated acetonitrile) were developed using infrared (IR) spectroscopy. Lewis acid site counts for Hf-Beta zeolites were validated by measuring integrated molar extinction coefficients (IMECs; ε, cm μmol –1 ) on Sn-Beta zeolites using identical Lewis base titrants to benchmark site counts with established literature procedures to quantify Lewis acid sites in Beta zeolites from IR spectra. Highlighting the importance of benchmarking active site counts against well-established experimental protocols, IMECs of CD 3 CN bound to open (ε(Sn; 2316 cm –1 ): 1.80 ± 0.25) and closed (ε(Sn; 2308 cm –1 ): 3.76 ± 0.33) Sn sites were ~1.8x larger than those previously reported while total Lewis acid site counts agreed with those measured by pyridine (ε(Sn; 1451 cm –1 ): 1.58 ± 0.16) on six different Sn-Beta zeolites. IMECs measured for IR peaks reflecting pyridine bound to Lewis acidic Hf sites (ε(Hf; 1448 cm –1 ): 1.54 ± 0.21) and CD 3 CN bound to open (ε(Hf; 2313 cm –1 ): 2.40 ± 0.22) and closed (ε(Hf; 2307 cm –1 ): 3.55 ± 0.41) Hf sites, gave similar counts for the total number of Lewis acidic sites across six Hf-Beta zeolites (Si/Hf = 100–413). Consistent with previous reports with Sn-Beta catalysts where open Sn sites are responsible for catalytic turnover, apparent first and zero-order MPVO rate constants (0.01–1 M cyclohexanone in 2-butanol; per total Hf, 373 K) correlated with the total number of open Hf sites, per total Hf, but not with the total number of closed Hf sites or total Lewis acid site counts. Measured initial MPVO rates (0.1 M cyclohexanone in 2-butanol, per open Hf, 373 K) were ~25x higher on hydrophobic Hf-Beta-F than on hydrophilic Hf-Beta-OH zeolites. Overall, the apparent first-order MPVO rate constants (2-butanol solvent, per open Hf, 373 K) were ~6x higher on Hf-Beta-F than on Hf-Beta-OH zeolites. The characterization methods reported here enable normalization of MPVO turnover rates on Sn- and Hf-Beta zeolites by their number of open sites. Finally, this enables performing quantitative rate comparisons across Lewis acid zeolites of varying active site identity, solvation, and pore topology used in liquid-phase catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro cavity fission chamber radiation detection system

A radiation detector to monitor the neutron flux of a nuclear reactor or other high-radiation environment, that can withstand the high temperatures and radiation fields of such environment, is provided. A small dielectric substrate with a low neutron-activation cross section is provided. The substrate is coated with a neutron conversion material, such as uranium oxide or thorium oxide. One or more substrates form a micro-sized detection cavity that is filled with a detection gas. A voltage is provided across anode and cathode wires in the detection cavity. A neutron absorbed in the conversion material may release reaction products into the gas, causing ionization of the gas which then produces a current or voltage signal. The small detector volume minimizes energy deposition into the detection gas by competing particles such as gamma rays, fast electrons, and beta particles, and therefore minimizes false counts while retaining large signals from neutron interactions.

McGregor, Douglas S.↗

Alpha/beta-gated gamma–gamma spectroscopy of mixed fission products for trace analysis

This experiment demonstrated that some hard-to-detect fission products can be quantified directly from mixed fission product samples using advanced radio-emission spectroscopy techniques. A gamma/gamma coincidence detector was combined with a custom liquid scintillation counter to evaluate the benefits of alpha and beta coincident and anti-coincident analysis of mixed fission product samples. Reduction factors in the minimum detectable activity (MDA) relative to traditional gamma counting were quantified for a set of radionuclides. For isotopes like 91Y, 144Ce, 147Nd, and 153Sm MDA reductions of factors of 1-2 were observed using optimized beta thresholds. Using beta anti-coincidence counting reductions of factors 3-5 were observed for isotopes like 89Sr, 95mNb, 115Cd, and 137Cs and factors of 5-7 for isotopes like 235U using alpha coincidence counting. The selectivity of gamma/gamma coincidence and reduction in backgrounds using beta gating were also demonstrated with 136Cs and 153Sm. The improvements observed in the detection sensitivity of fission products and actinides achieved by combining time-correlated radiation signatures is significant and of value to applications such as nuclear fission physics, environmental monitoring for nuclear waste, reactor accidental releases, and nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Integrating Metal-Hydride and Gas-Detector for Tritium Gas Detection

Detection of trace amounts of environmental tritium is a challenging problem, driving the need for field-deployable systems that offer high sensitivity, selectivity, and minimal false positives. We present a technique for high-sensitivity, high-selectivity tritium measurement, which integrates metal-hydride and gas-detector concepts into a compact field-deployable tritium sensor. A hydrogen-storage metal embedded in a gas proportional counter selectively absorbs protium (1H)/tritium (3H), which are subsequently released into the counter volume with a reduced radiation background. Ionizations induced by 3H beta particles are then measured in proportional counting mode, achieving high detection efficiency. Preliminary studies conducted with palladium (Pd) thin films coated on stainless-steel substrates demonstrated 3H absorption and metal-tritide formation, followed by 3H desorption upon heating the metal-tritide. These processes were confirmed using activity concentrations measured by a commercial tritium monitor and pulse height spectra acquired from a custom-built detector.

Gas-proportional counter↗

A new algorithm for estimating radioxenon concentrations

A new algorithm (Xcounts) is introduced for estimating the activity concentrations of the xenon isotopes 131m Xe, 133m Xe, 133 Xe, and 135 Xe using beta-gamma coincidence data. The algorithm simultaneously estimates the decay counts associated with the four xenon isotopes, background, and radon in contrast to the net-counts method that uses sequential residual removal to account for background and interreferences. Calibration data for background counts are determined from gas-background measurements and simulation. In Xcounts, the false positive count rates for 131m Xe and 133m Xe are lower than the false positive rates for 133 Xe and 135 Xe. This algorithm appears to reliably detect the metastable isotopes at lower activity levels than the net-counts method and have similar performance for the other isotopes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Synchrotron fluorescence imaging of individual mouse beta-cells reveals changes in zinc, calcium, and iron in a model of low-grade inflammation

Pancreatic beta-cells synthesize and secrete insulin maintaining an organism's energy homeostasis. In humans, beta-cell dysfunction and death contribute to the pathogenesis of type 2 diabetes (T2D). Although the causes of beta-cell dysfunction are complex, obesity-induced low-grade systemic inflammation plays a role. For example, obese individuals exhibiting increased levels of proinflammatory cytokines IL-6 and IL-1beta have a higher risk of beta-cell dysfunction and T2D. Interestingly, obesity-induced inflammation changes the expression of several cellular metal regulating genes, prompting this study to examine changes in the beta-cell metallome after exposure to proinflammatory-cytokines. Here, primary mouse beta-cells were exposed to a combination of IL-6 and IL-1beta for 48 hours, were chemically fixed and imaged by synchrotron X-ray fluorescent microscopy. Quantitative analysis showed a surprising 2.4-fold decrease in the mean total cellular content of zinc from 158 ± 57.7 femtograms (fg) to 65.7 ± 29.7 fg; calcium decreased from 216 ± 67.4 to 154.3 ± 68.7 fg (control vs. cytokines, respectively). The mean total cellular iron content slightly increased from 30.4 ± 12.2 to 47.2 ± 36.4 fg after cytokine treatment; a sub-population of cells (38%) exhibited larger increases of iron density. Changes in the subcellular distributions of zinc and calcium were observed after cytokine exposure. Beta-cells contained numerous iron puncta that accumulated still more iron after exposure to cytokines. These findings provide evidence that exposure to low levels of cytokines is sufficient to cause changes in the total cellular content and/or subcellular distribution of several metals known to be critical for normal beta-cell function.

59 BASIC BIOLOGICAL SCIENCES↗

Generalized eikonal identities for charged currents

Abstract We discuss QED radiative corrections to contact operators coupling two heavy fields and one light field. These operators appear ubiquitously in weak interactions with nuclei such as beta decay and neutrino nucleus scattering. New eikonal identities are derived in the static limit (i.e., neglecting nuclear recoil) that allow for manifest power counting of enhancements proportional to the charge of the nucleus. We apply these new identities to nuclear beta decays and find that the “independent particle model” used by Jaus, Rasche, Sirlin & Zucchini is closely related, though not identical, to a model independent effective field theorcalculation.

Physics↗

Analysis and Recommendation of Alpha-Beta Continuous Air Monitor Alarm Setpoints for the RPL Stack Exhaust

The Radiochemical Processing Laboratory (RPL) alpha-beta continuous air monitor (CAM) is used for real-time detection of “artificial” alpha-beta particulates from the stack exhaust. The CAM interfaces with software developed by the Pacific Northwest National Laboratory—called the “PNNL OS3300 Alpha-Beta Monitoring Software”—that provides real-time estimates of alpha-beta air concentrations and integrated activities that are calculated from measured CAM counts. The OS3300 software has alarm setpoints that can be used to provide an early indication of larger releases, that if allowed to persist, could approach defined dose limits. This report performs a detailed review of historical and current alarm setpoints used at RPL, including discussion of the technical basis used in their development, analysis of alarm frequencies using measured historical data, and performs a detailed dose assessment using more realistic release scenarios, meteorology, and adjustment factors used in estimating released stack activity. Based on the results, the alpha and beta air concentration alarm setpoints will remain 1.77 × 10 -8 µCi/ml and 3.47 × 10 -8 µCi/ml, respectively; and the alpha and beta integrated activity alarm setpoints will remain 70.22 µCi and 137.63 µCi, respectively. These setpoints achieve the right operational balance in identifying larger releases from planned radiological work at RPL, without being overly conservative so as to cause nuisance alarming. Furthermore, implied doses associated with these setpoints are below defined and regulatory limits.

325RPL↗

The nylon balloon for xenon loaded liquid scintillator in KamLAND-Zen 800 neutrinoless double-beta decay search experiment

The KamLAND-Zen 800 experiment is searching for the neutrinoless double-beta decay of 136 Xe by using 136 Xe-loaded liquid scintillator. The liquid scintillator is enclosed inside a balloon made of thin, transparent, low-radioactivity film that we call Inner Balloon (IB). The IB, apart from guaranteeing the liquid containment, also allows to minimize the background from cosmogenic muon-spallation products and 8B solar neutrinos. Indeed these events could contribute to the total counts in the region of interest around the Q-value of the double-beta decay of 136 Xe. In this paper, we present an overview of the IB and describe the various steps of its commissioning minimizing the radioactive contaminations, from the material selection, to the fabrication of the balloon and its installation inside the KamLAND detector. Finally, we show the impact of the IB on the KamLAND background as measured by the KamLAND detector itself.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiple Changepoint Detection for Non‐Gaussian Time Series

ABSTRACT This article combines methods from existing techniques to identify multiple changepoints in non‐Gaussian autocorrelated time series. A transformation is used to convert a Gaussian series into a non‐Gaussian series, enabling penalized likelihood methods to handle non‐Gaussian scenarios. When the marginal distribution of the data is continuous, the methods essentially reduce to the change of variables formula for probability densities. When the marginal distribution is count‐oriented, Hermite expansions and particle filtering techniques are used to quantify the scenario. Simulations demonstrating the efficacy of the methods are given and two data sets are analyzed: 1) the proportion of home runs hit by Major League Baseball batters from 1920 to 2023 and 2) a six‐dimensional series of tropical cyclone counts from the Earth's basins of generation from 1980 to 2023. In the first series, beta marginal distributions are used to describe the proportions; in the second, Poisson marginal distributions seem appropriate.

Lund, Robert [Department of Statistics University ↗

Characterization of PIPS detectors for measurement of radioxenon

The International Monitoring System arm of the Comprehensive Nuclear-Test-Ban Treaty Organization utilizes sampling of atmospheric radioxenon to scan the world for nuclear testing events. Current designs utilized in the field involve plastic scintillator cells run in coincidence with Sodium Iodide (NaI) or High Purity Germanium (HPGe) detectors. The use of plastic scintillators as electron detectors exhibit some issues in comparison to other materials. Silicon detectors are analyzed as an alternative to plastic scintillators for beta detection based on their higher energy resolution and lowered memory effect. A radioxenon detection setup was created with the intent of measuring radioxenon samples using coincidence counting between silicon and NaI detectors as well as silicon and HPGe. Finally, the absolute efficiency of both setups is calculated and compared.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Online Alpha Monitoring of High Cs-137 Hanford and SRS High Level Waste with Tensioned Metastable Fluid Detectors

The Department of Energy’s Hanford and Savannah River Sites maintain millions of gallons of caustic supernate and salt high activity waste in their high-level waste (HLW) tank farm inventories. The Savannah River Site is currently treating this waste with a calixarene-based solvent extraction of Cs-137 to reduce these inventories. Hanford is employing an at-tank crystalline silico titanate (CST) based solid phase extraction methodology to reduce their liquid HLW inventories. Due to the high solubility of Cs-137 and the relative insolubility of the actinides in these caustic waste forms, the beta to alpha radioactivity ratio can often exceed six orders of magnitude in the feed solutions to these treatment processes. This unique characteristic leads to significant technical challenges in making rapid gross alpha measurements in the presence of the overwhelming beta, gamma, as well as dissolved sodium salt in these HLW matrices. Conventional radioanalytical techniques, such as liquid scintillation analysis or gas flow proportional counting require significant radiochemistry preparation prior to the radiometric measurements for gross alpha activity. These required pretreatments render these technologies untenable for rapid quantification of gross alpha activity that could be required to support on or at-line measurements ensuring a waste stream will meet regulatory requirements. The radiation measurement properties of Tensioned Metastable Fluid Detectors (TMFDs) have been studied by Purdue University’s Taleyarkhan research group for well over a decade. Fluids tensioned to the appropriate degree will rupture when struck by radiation, resulting in a measurable cavitation event. The negative pressure generating this tension can be adjusted by centrifugal rotation or by acoustic means in such a way that these cavitation events can be generated from alpha radiation but will not be generated by beta or gamma radiation. Purdue University and the Savannah River National Laboratory are currently collaborating to develop a gamma/beta blind, spectroscopic alpha measurement system based on the Tensioned Metastable Fluid Detector technology to provide a potential solution for performing rapid gross alpha measurements on these high gamma/beta sample matrices. Measurements using the Indirect Drive Acoustically Tensioned Metastable Fluid Detectors developed as part of this collaboration were performed with an alpha emitting radionuclide. Successful determination of gross alpha activity was observed, indicating a potential pathway for rapid gross alpha measurements in remote-handled shielded cells or in process situations requiring online alpha monitoring. Measurements using this system have been conducted on high beta activity solutions, demonstrating the beta blind capability of this system. Measurements are currently underway to test the system’s capability to measure gross alpha activity on Savannah River Site high level waste high Cs-137 samples that have been measured by the SRNL radiochemistry team. This work was supported by the DOE EM Technology Development program.

DiPrete, David [Savannah River National Laboratory↗

2 νββ spectrum in chiral effective field theory

We investigate two-neutrino double beta decay (2νββ) in chiral effective field theory. We find contributions from weak magnetism and double-weak pion-exchange at next-to-leading-order in the chiral power counting. We discuss the impact of the chiral corrections on the electron spectra and find that they should be included in analyses of 2νββ decay that aim to uncover new physics signatures in the electron spectrum. We illustrate this point by revisiting the effect of sterile neutrinos and non-standard charged interactions. We also find that the pion-exchange contributions involve nuclear matrix elements that are related to those appearing in neutrinoless double beta decay (0νββ). We investigate whether the 0νββ nuclear matrix elements can be obtained from detailed measurements of the energy spectrum of the outgoing electrons in 2νββ transitions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Annihilation-gamma-based diagnostic techniques for magnetically confined electron–positron pair plasma

Efforts are underway to magnetically confine electron–positron pair plasmas to study their unique behaviour, which is characterized by significant changes in plasma time and length scales, supported waves and unstable modes. However, use of conventional plasma diagnostics presents challenges with these low-density and annihilating matter–antimatter plasmas. To address this problem, we propose to develop techniques based on the distinct emission provided by annihilation. This emission exhibits two spatial correlations: the distance attenuation of isotropic sources and the back-to-back propagation of momentum-preserving 2 $\gamma$ annihilation. We present the results of our analysis of the $\gamma$ emission rate and the spatial profile of the annihilation in a magnetized pair plasma from direct pair collisions, from the formation and decay of positronium as well as from transport processes. In order to demonstrate the effectiveness of annihilation-based techniques, we tested them on annular $\gamma$ emission profiles produced by a $\beta ^+$ radioisotope on a rotating turntable. Direct and positronium-mediated annihilation result in overlapping volumetric $\gamma$ sources, and the 2 $\gamma$ emission from these volumetric sources can be tomographically reconstructed from coincident counts in multiple detectors. Transport processes result in localized annihilation where field lines intersect walls, limiters or internal magnets. These localized sources can be identified by the fractional $\gamma$ counts on spatially distributed detectors.

Physics↗

Diabetes and hypertension are related to amyloid-beta burden in the population-based Rotterdam Study

Abstract Higher vascular disease burden increases the likelihood of developing dementia, including Alzheimer’s disease. Better understanding the association between vascular risk factors and Alzheimer’s disease pathology at the predementia stage is critical for developing effective strategies to delay cognitive decline. In this work, we estimated the impact of six vascular risk factors on the presence and severity of in vivo measured brain amyloid-beta (Aβ) plaques in participants from the population-based Rotterdam Study. Vascular risk factors (hypertension, hypercholesterolaemia, diabetes, obesity, physical inactivity and smoking) were assessed 13 (2004–2008) and 7 years (2009–2014) prior to 18F-florbetaben PET (2018–2021) in 635 dementia-free participants. Vascular risk factors were associated with binary amyloid PET status or continuous PET readouts (standard uptake value ratios, SUVrs) using logistic and linear regression models, respectively, adjusted for age, sex, education, APOE4 risk allele count and time between vascular risk and PET assessment. Participants’ mean age at time of amyloid PET was 69 years (range: 60–90), 325 (51.2%) were women and 190 (29.9%) carried at least one APOE4 risk allele. The adjusted prevalence estimates of an amyloid-positive PET status markedly increased with age [12.8% (95% CI 11.6; 14) in 60–69 years versus 35% (36; 40.8) in 80–89 years age groups] and APOE4 allele count [9.7% (8.8; 10.6) in non-carriers versus 38.4% (36; 40.8) to 60.4% (54; 66.8) in carriers of one or two risk allele(s)]. Diabetes 7 years prior to PET assessment was associated with a higher risk of a positive amyloid status [odds ratio (95% CI) = 3.68 (1.76; 7.61), P < 0.001] and higher standard uptake value ratios, indicating more severe Aβ pathology [standardized beta = 0.40 (0.17; 0.64), P = 0.001]. Hypertension was associated with higher SUVr values in APOE4 carriers (mean SUVr difference of 0.09), but not in non-carriers (mean SUVr difference 0.02; P = 0.005). In contrast, hypercholesterolaemia was related to lower SUVr values in APOE4 carriers (mean SUVr difference −0.06), but not in non-carriers (mean SUVr difference 0.02). Obesity, physical inactivity and smoking were not related to amyloid PET measures. The current findings suggest a contribution of diabetes, hypertension and hypercholesterolaemia to the pathophysiology of Alzheimer’s disease in a general population of older non-demented adults. As these conditions respond well to lifestyle modification and drug treatment, further research should focus on the preventative effect of early risk management on the development of Alzheimer’s disease neuropathology.

van Arendonk, Joyce (ORCID:0000000172941633)↗

Evidence for a cytokine-sensitive network of iron-associated genes that protects pancreatic islets against ferroptosis

Background/Objectives: The micronutrient iron is closely connected to inflammation and is among the complex factors contributing to beta-cell failure in diabetes. High levels of dietary iron increase the risk of developing type 2 diabetes, and excessive iron uptake by beta-cells can cause oxidative stress and inhibit function. Elevated levels of proinflammatory cytokines in obese individuals, such as interleukin (IL)-1beta and IL-6, increase the risk of developing type 2 diabetes, and there is evidence that these low levels of circulating cytokines can lead to islet dysfunction. Methods: In this study, gene microarray and other data were analyzed for expression differences in islets treated for 48 h with 10 pg/mL IL-1beta + 20 pg/mL IL-6 as a model of low-grade inflammation versus untreated. Results: Three iron-associated genes were among the most cytokine-sensitive in the mouse genome: Hamp, Steap4, and Lcn2. These proteins are all involved with increasing/retaining cellular iron. We hypothesized that increased cellular iron would lead to increased susceptibility to ferroptosis. Surprisingly, 24 h pre-exposure to low-grade inflammation, which upregulates this iron-gene network, prevented subsequent erastin-induced ferroptosis. We also found that Steap4 overexpression reduced islet dysfunction caused by high-dose proinflammatory cytokines (10× low-dose), suggesting an overall protective effect. Steap4 overexpression also upregulated Hamp and Lcn2, suggesting Steap4 regulates these cytokine-sensitive iron genes.; in contrast, ferritin and ferroportin gene expression, which are not sensitive to cytokines, were unchanged. Conclusions: These data suggest an inflammation-induced network of genes involved in cellular iron uptake and retention plays a protective role in islets against oxidative stress and ferroptosis.

IL-1β↗

Analysis of 127 Xe tracer measurements using a net counts method

A suite of measurement systems were deployed as part of the Physical Experiment 1 series of experiments, which involved detonating chemical explosives along with radionuclide tracers in an underground cavity, at the Nevada National Security Site (NNSS) in the United States. One of the radionuclide tracers, 127 Xe was released from the containment following the explosion and detected on a SAUNA Q B sampler situated approximately 3.5 km away. The system uses a beta-gamma coincidence detector system to measure fission product radioisotopes of xenon relevant to nuclear explosion monitoring. In this work we use the coincidence measurement data to analyse and interpret the results from the SAUNA Q B system, to calculate the measured 127 Xe activity concentration(s).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Counting facilities at the Black Hills Underground Campus

The Black Hills Underground Campus (BHUC) houses a low background counting facility on the 4850’ level of the Sanford Underground Research Facility (SURF) with ~4300 m w.e. of rock overburden. Currently there are five ultra-low-background, high-purity germanium detectors operating inside of a class-1,000 cleanroom at the Davis Campus, with a sixth anticipated to be installed within a year. Here, a robust nitrogen purge system and on-site personnel assistance allow these detectors to run continuously to support groups that need low background counting of materials.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗