Windowless X-Ray Tube Spectrometer for Light Element Analysis
Windowless tube spectrometer for x-ray fluorescent analysis of light elements
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Windowless tube spectrometer for x-ray fluorescent analysis of light elements
Balanced filters evaluated for performance in X-ray fluorescence analysis of lunar and planetary surface materials
Windowless tube spectrometer for x-ray fluorescent analysis of light elements down through fluorine
Analyses of major elements in tektite by rapid silicate procedures and X-ray fluorescence techniques
Potassium/rubidium ratios and individual K and Rb contents for 54 tektites determined by flame photometry or X-ray fluorescence
The dynamic nuclear polarization of hydrogen nuclei by the solid effect in single crystals of samarium doped lanthanum magnesium nitrate (Sm:LMN) was studied theoretically and experimentally. The equations of evolution governing the dynamic nuclear polarization by the solid effect were derived in detail using the spin temperature theory and the complete expression for the steady state enhancement of the nuclear polarization was calculated. Experimental enhancements of the proton polarization were obtained for eight crystals at 9.2 GHz and liquid helium temperatures. The samarium concentration ranged from 0.1 percent to 1.1 percent as determined by X-ray fluorescence. A peak enhancement of 181 was measured for a 1.1 percent Sm:LMN crystal at 3.0 K. The maximum enhancements extrapolated with the theory using the experimental data for peak enhancement versus microwave power and correcting for leakage, agree with the ideal enhancement (240 in this experiment) within experimental error for three of the crystals.
Several spectrometers carried in the Service Module of the Apollo 15 and Apollo 16 spacecraft were employed for the compositional mapping of the lunar surface. The observations involved the measurements of secondary (fluorescent) X-rays, gamma rays and alpha particle emissions. A large scale compositional map of over 20 percent of the lunar surface was obtained for the first time. It was possible to demonstrate interesting chemical differences between the mare and the highlands, to find specific areas of high radioactivity and to learn something about the composition of the moon's hidden side. Further the same devices were used to obtain useful astronomical data during the return to earth.
Directional air samplers, used for resolving suspended particulate matter on the basis of time and wind direction were used to assess the feasibility of characterizing and identifying emission source types in urban multisource environments. Filters were evaluated for 16 elements and X-ray fluorescence methods yielded elemental concentrations for direction, day, and the interaction of direction and day. Large numbers of samples are necessary to compensate for large day-to-day variations caused by wind perturbations and/or source changes.
Adaptation of vacuum X-ray spectrometer for light element analysis
Lunar X-ray emission measured by Lunik X lunar probe
A literature survey was conducted to collect material properties data on all advanced high temperature materials. Three of these, Y2O3-stabilized ZrO2, ThO2, and ZrB2 with additives of C and SiC were selected for further study. Stabilized ZrO2 and ThO2 were found to have higher temperature oxidation resistance than any metal and great potential for use in advanced biowaste resistojets. ZrO2 has a lower electrical resistivity and sublimation and a higher creep endurance strength. ZrO2 and ThO2 tubular heat exchangers, electrically heated indirectly, were evaluated in short tests to about 1900 K in flowing CO2. ZrO2 was subjected to N2, H2, H2O and vacuum as well. X-ray diffraction and fluorescence analyses were made. The metal-to-ceramic seal technology for ZrO2 and ThO2 was developed using chemical vapor deposition of tantalum for metallizing and 82 Au - 18 Ni filler braze.
X-ray spectroscopy of light elements by the elimination of the window between target and a fluorescing sample of a demountable x-ray tube
An experimental technique is described that allows for the joint study of the kinetics and of the oxide structure during the high temperature oxidation of metal surfaces. Oxygen is supplied at the metal through an electrochemical oxygen pump and the oxygen pressure, at the metal surface, is measured during oxidation by a YSZ (yttria stabilized zirconia) oxygen sensor. XAS (x-ray absorption spectroscopy) is performed in fluorescence mode at the cation K edge and after each oxidation step. An appropriate analysis of the XAS spectra could provide information on both the oxidation kinetics and oxide structure. Experimental data on the high temperature oxidation of nickel, cobalt, and Fe(64%)Ni(36%) alloy, at low oxygen pressure, are reported and analyzed according to the proposed data reduction. These results indicate the presented technique to be particularly suitable for studying the hot corrosion of oxide film too thick for common surface spectroscopy (AUGER, ESCA) and too thin for conventional thermogravimetric technique.
A diffuse atmospheric fluorescence pulse having the proper signatures of an excitation caused by a fast burst of X-ray photons incident from the general direction of the recent supernova in NGC 5253, was recorded on May 3, 1972, at 20 hr 48 min 51 sec UT. Due to excessive background pulses of terrestrial origin, it is concluded that the evidence should at best be regarded as suggestive. It is recommended that the data of satellite-borne X-ray detectors be examined for anomalies at the indicated time.
The Type IIn supernova (SN IIn) 2005ip is one of the most well-studied and long-lasting examples of an SN interacting with its circumstellar environment. The optical light curve plateaued at a nearly constant level for more than five years, suggesting ongoing shock interaction with an extended and clumpy circumstellar medium (CSM). Here, we present continued observations of the SN from ∼1000 to 5000 d post-explosion at all wavelengths, including X-ray, ultraviolet, near-infrared (NIR), and mid-infrared. The UV spectra probe the pre-explosion mass loss and show evidence for CNO processing. From the bolometric light curve, we find that the total radiated energy is in excess of 10 50 erg, the progenitor star’s pre-explosion mass-loss rate was >~ 1 × 10 −2 Mꙩ yr −1 , and the total mass lost shortly before explosion was >~1Mꙩ, though the mass lost could have been considerably larger depending on the efficiency for the conversion of kinetic energy to radiation. The ultraviolet through NIR spectrum is characterized by two high-density components, one with narrow high-ionization lines, and one with broader low-ionization H I, He I, [OI], Mg II, and Fe II lines. The rich Fe II spectrum is strongly affected by Lyα fluorescence, consistent with spectral modelling. Both the Balmer and He I lines indicate a decreasing CSM density during the late interaction period. We find similarities to SN 1988Z, which shows a comparable change in spectrum at around the same time during its very slow decline. These results suggest that, at long last, the shock interaction in SN 2005ip may finally be on the decline.
Digital computer controlled X ray fluorescent spectroscopy of geological materials
Scattering process of solar X rays with photoionization fluorescence by planetary atmospheres
Planetary atmospheres X ray fluorescence, calculating Mercury, Venus, earth, Mars and Jupiter emissions