Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transfer Function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Ionospheric Transfer Function Tests: Line of Sight and Slab

Ionospheric transfer function (ITF) algorithms determine the effects of the ionosphere on an electromagnetic (EM) signal as it propagates through. In this report, analytic formulas are derived which can be used to compare results of ITF calculations from certain algorithms.

97 MATHEMATICS AND COMPUTING↗

Characterizing short-term stability for Boolean networks over any distribution of transfer functions

Here we present a characterization of short-term stability of random Boolean networks under arbitrary distributions of transfer functions. Given any distribution of transfer functions for a random Boolean network, we present a formula that decides whether short-term chaos (damage spreading) will happen. We provide a formal proof for this formula, and empirically show that its predictions are accurate. Previous work only works for special cases of balanced families. Finally, it has been observed that these characterizations fail for unbalanced families, yet such families are widespread in real biological networks.

97 MATHEMATICS AND COMPUTING↗

Normalization of the modulation transfer function: The open-field approach

The modulation transfer function (MTF) is widely used to describe the spatial resolution of x-ray imaging systems. The MTF is defined to have a zero-frequency value of unity, and it is common practice to ensure this by normalizing a measured MTF curve by the zero-frequency value. However, truncation of the line spread function (LSF) within a finite region of interest (ROI) results in spectral leakage and causes a reduction in the measured MTF zero-frequency value equal to the area of truncated LSF tails. Subsequent normalization by this value may result in inflated MTF values. We show that open-field normalization with the edge method produces accurate MTF values at all nonzero frequencies without need for further normalization by the zero-frequency value, regardless of ROI size. While both normalization techniques are equivalent for a sufficiently large ROI, a 5% inflation in MTF values was observed for a CsI-based flat-panel system when using a 10 cm ROI. Use of open-field normalization avoids potential inflation caused by zero-frequency normalization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Topography restoration in white-light interferometry using an instrument transfer function evaluated with binary pseudo-random arrays

Accurate knowledge of the instrument transfer function (ITF) is vital for topography measurements using white-light interferometry (WLI). To this end, we derive a complete set of analytical expressions for the power spectral density (PSD) of a discretely sampled binary pseudo-random array (BPRA) as a theoretical benchmark. We then determine the ITF by comparing this theoretical PSD with the measured PSD of the BPRA. For the Zygo ZeGage Pro HR with a objective, the determined ITF closely matches the nominal modulation transfer function (MTF). Accordingly, we integrate the nominal MTF into Fourier-domain restoration filters and apply them to practical WLI topography data, yielding restored topographies that show improved agreement with atomic force microscopy measurements. Overall, our integrated BPRA-based ITF measurement and filtering methodology offers a robust yet practical means of characterizing WLI performance and enhancing the accuracy of surface measurements.

Hirose, Shigenobu [Japan Agency for Marine Earth S↗

Practical considerations in using a binary pseudorandom array for instrument transfer function calibration

Binary pseudo-random array (BPRA) artifacts are useful devices for calibrating the instrument transfer function (ITF) of interferometric microscopes and other optical and non-optical surface and wavefront measurement instruments. The intrinsic white noise character of the power spectral density function of the artifact simplifies the deconvolution of the ITF from the measured power spectral density (PSD). However, resampling of the BPRA intrinsic artifact features with the measurement tool's specific sampling pattern modifies the white noise character of the intrinsic spectrum and needs to be accounted for in the ITF-based data deconvolution process. We have developed an analytic solution to the spectrum of a resampled one- and two- dimensional BPRA. The resultant nominal PSD function is a simple twoparameter cosine function with a period equal to the resampled pixel width. A transfer function model for interferometric microscopes that incorporates this function, along with an ITF that includes aliasing effects and variable numerical aperture (NA), wavelength, and obscuration factor, is used to fit to the BPRA PSDs measured by an interference microscope for a range of objective and zoom lens magnification combinations.

Takacs, PZ↗

Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Functions of Surface Profilometers

A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in [Proc. SPIE 7077-7, (2007), Opt. Eng. 47(7), 073602-1-5 (2008)]is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high-confidence of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two dimensional BPR arrays using two different interferometric microscopes and a scatterometer. We also present the results of application of the experimentally determined MTF correction to the measurement taken with the MicromapTM-570 interferometric microscope of the surface roughness of a super-polished test mirror. In this particular case, without accounting for the instrumental MTF, the surface rms roughness over half of the instrumental spatial frequency bandwidth would be underestimated by a factor of approximately 1.4.

47 OTHER INSTRUMENTATION↗

Validity of the line-pair bar-pattern method in the measurement of the modulation transfer function (MTF) in megavoltage imaging

The measurement of the modulation transfer function (MTF) of an imaging device is a common requirement in evaluating radiographic detector performance. Such measurements are considered mandatory in detector development research, and may also be carried out as part of routine quality assurance (QA) checks of image quality. Traditionally, MTF measurement has been performed by imaging either a narrow slit or a sharp edge in order to generate a line spread function, whose Fourier transform provides the MTF on a near-continuous frequency domain. Much less commonly employed is the method of square-wave line-pair modulations, in which the modulation response to bar resolution targets contained in a bar pattern is used to estimate the MTF at discrete spatial frequencies. While the slit and edge methods offer advantages of accuracy and a well-known standardized protocol for measurement based on several decades of development, their major limitation is the difficult and time-consuming experimental setup that is necessary to ensure accurate measurements. On the other hand, the bar pattern offers the advantage of a quick, simple, and easy measurement without the need for a complex experimental setup, with the main disadvantages of the technique being a pseudo-normalization that may lead to an overestimated MTF, and corrections for removing higher-order frequency harmonics that require interpolating between discrete spatial frequencies. Therefore, bar patterns are traditionally used for qualitative imaging applications like detector QA in terms of relative and arbitrarily defined spatial resolution metrics, while slit and edge methods are preferred for quantitative MTF measurements. Compared to diagnostic x rays, MTF measurements using megavoltage x rays are further complicated by low x-ray attenuation and excessive Compton scattering. In this work, a method to measure the MTF of megavoltage x-ray detectors based on imaging square-wave line pairs with improved near-zero-frequency normalization was developed as an adaptation to previously reported methods. Monte Carlo simulations were used to identify an improved normalization condition with which the accuracy of the MTF determined from line-pair modulations could be enhanced considerably compared to previously used techniques. Slit, edge, and bar-pattern measurements were performed to obtain the MTF of commercial megavoltage imaging devices including portal film and electronic portal imaging devices. A comparison of the MTF measurements from the three techniques was used to ascertain the validity of the proposed bar-pattern method for accurate and reliable measurement of MTF for megavoltage imagers. Statistical analyses revealed no significant differences between the bar-pattern method and the standard slit and edge techniques, indicating very good agreement (mean difference within {+-}3%). These results indicated the potential for line-pair bar patterns to be used more effectively than in the past for traditional QA imaging as well as for quantitative MTF measurement in detector development research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dark matter transfer function: Free streaming, particle statistics, and memory of gravitational clustering

The transfer function T(k) of dark matter (DM) perturbations during matter domination is obtained by solving the linearized collisionless Boltzmann-Vlasov equation. We provide an exact expression for T(k) for arbitrary distribution functions of decoupled particles and initial conditions, which can be systematically expanded in a Fredholm series. An exhaustive numerical study of thermal relics for different initial conditions reveals that the first two terms in the expansion of T(k) provide a remarkably accurate and simple approximation valid on all scales of cosmological relevance for structure formation in the linear regime. The natural scale of suppression is the free-streaming wave vector at matter-radiation equality, k{sub fs}(t{sub eq})=[4{pi}{rho}{sub 0M}/[<V-vector{sup 2}>(1+z{sub eq})]]{sup 1/2}. An important ingredient is a nonlocal kernel determined by the distribution functions of the decoupled particles which describes the memory of the initial conditions and gravitational clustering and yields a correction to the fluid description. This correction is negligible at large scales k<<k{sub fs}(t{sub eq}) but it becomes important at small scales k{>=}k{sub fs}(t{sub eq}). Distribution functions that favor the small momentum region yield longer-range memory kernels and lead to an enhancement of power at small scales k>k{sub fs}(t{sub eq}). Fermi-Dirac and Bose-Einstein statistics lead to long-range memory kernels, with longer-range for bosons, both resulting in enhancement of T(k) at small scales. For DM thermal relics that decoupled while ultrarelativistic we find k{sub fs}(t{sub eq}){approx_equal}0.003(g{sub d}/2){sup 1/3} (m/keV) [kpc]{sup -1}, where g{sub d} is the number of degrees of freedom at decoupling. For WIMPS we obtain k{sub fs}(t{sub eq})=5.88(g{sub d}/2){sup 1/3} (m/100 GeV){sup 1/2} (T{sub d}/10 MeV){sup 1/2} [pc]{sup -1}. For k<<k{sub fs}(t{sub eq}), T(k){approx}1-C[k/k{sub fs}(t{sub eq})]{sup 2} where C=O(1) and independent of statistics for thermal relics. We provide simple and accurate fits for T(k) in a wide range of small scales k>k{sub fs}(t{sub eq}) for thermal relics and different initial conditions. The numerical and analytic results for arbitrary distribution functions and initial conditions allow an assessment of DM candidates through their impact on structure formation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: Expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

47 OTHER INSTRUMENTATION↗

Simulation of the photo-luminescent coupling transfer function in multijunction nanoheterostructure solar cells

A mathematical model of recombination radiation transfer in multilayer heterostructures for calculating photoluminescent coupling transfer function has been developed. The photoluminescent coupling effectiveness for the GaInP-GaInAs and GaInAs-Ge subcell pairs being a part of multijunction GaInP/GaInAs/Ge SCs has been investigated. The simulation results were compared with experimental data. The electroluminescence effectiveness estimation for a wide band gap subcell in each pair has been performed. An anomalously high value of the photoluminescent coupling for the GaInAs-Ge subcell pair has been observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Binary Pseudo-Random Gratings and Arrays for Calibration of Modulation Transfer Functions of Surface Profilometers

A technique for precise measurement of the modulation transfer function (MTF), suitable for characterization of a broad class of surface profilometers, is investigated in detail. The technique suggested in papers Yashchuk et al. (2007), Yashchuk et al. (2008) is based on use of binary pseudo-random (BPR) gratings and arrays as standard MTF test surfaces. Unlike most conventional test surfaces, BPR gratings and arrays possess white-noise-like inherent power spectral densities (PSD), allowing the direct determination of the one- and two-dimensional MTF, respectively, with a sensitivity uniform over the entire spatial frequency range of a profiler. In the cited work, a one-dimensional realization of the suggested method based on use of BPR gratings has been demonstrated. Here, a high performance of the MTF calibration technique is demonstrated via cross comparison measurements of a number of two-dimensional BPR arrays using two different interferometric microscopes and a scatterometer. We also present the results of application of the experimentally determined MTF correction to the measurement taken with the Micromap{trademark}-570 interferometric microscope of the surface roughness of a super-polished test mirror. In this particular case, without accounting for the instrumental MTF, the surface rms roughness over half of the instrumental spatial frequency bandwidth would be underestimated by a factor of approximately 1.4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47, 073602 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A616, 172 (2010)]. Here we report on a further expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

42 ENGINEERING↗

ARMAX-Based Transfer Function Model Identification Using Wide-Area Measurement for Adaptive and Coordinated Damping Control

One of the main drawbacks of the existing oscillation damping controllers that are designed based on offline dynamic models is adaptivity to the power system operating condition. With the increasing availability of wide-area measurements and the rapid development of system identification techniques, it is possible to identify a measurement-based transfer function model online that can be used to tune the oscillation damping controller. Such a model could capture all dominant oscillation modes for adaptive and coordinated oscillation damping control. our paper describes a comprehensive approach to identify a low-order transfer function model of a power system using a multi-input multi-output (MIMO) autoregressive moving average exogenous (ARMAX) model. This methodology consists of five steps: 1) input selection; 2) output selection; 3) identification trigger; 4) model estimation; and 5) model validation. The proposed method is validated by using ambient data and ring-down data in the 16-machine 68-bus Northeast Power Coordinating Council system. Our results demonstrate that the measurement-based model using MIMO ARMAX can capture all the dominant oscillation modes. Compared with the MIMO subspace state space model, the MIMO ARMAX model has equivalent accuracy but lower order and improved computational efficiency. The proposed model can be applied for adaptive and coordinated oscillation damping control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Measuring Magnets Transfer Functions in the NSRL Transport Line

The beamline at the NASA Space Radiation Laboratory (NSRL) is equipped with a range of magnets, including dipole magnets, dipole corrector magnets, quadrupole magnets, sextupole magnets, and octupole magnets. The magnet transfer function defines the relationship between the power supply currents and the corresponding magnet strengths. This note presents the measurements of the transfer functions for the dipole correctors and quadrupole magnet in the NSRL beamline.

43 PARTICLE ACCELERATORS↗

Determination of modulation transfer function of a printer by measuring the autocorrelation of the transmission function of a printed Ronchi grating

We show theoretically and verify experimentally that the modulation transfer function (MTF) of a printing system can be determined by measuring the autocorrelation of a printed Ronchi grating. In practice, two similar Ronchi gratings are printed on two transparencies and the transparencies are superimposed with parallel grating lines. Then, the gratings are uniformly illuminated and the transmitted light from a large section is measured versus the displacement of one grating with respect to the other in a grating pitch interval. This measurement provides the required autocorrelation function for determination of the MTF.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic Field Mapping and Integral Transfer Function Matching of the Prototype Dipoles for the NSLS-II at BNL

The National Synchrotron Light Source-II (NSLS-II) storage ring at Brookhaven National Laboratory (BNL) will be equipped with 54 dipole magnets having a gap of 35 mm, and 6 dipoles having a gap of 90 mm. Each dipole has a field of 0.4 T and provides 6 degrees of bending for a 3 GeV electron beam. The large aperture magnets are necessary to allow the extraction of long-wavelength light from the dipole magnet to serve a growing number of users of low energy radiation. The dipoles must not only have good field homogeneity (0.015% over a 40 mm x 20 mm region), but the integral transfer functions and integral end harmonics of the two types of magnets must also be matched. The 35 mm aperture dipole has a novel design where the yoke ends are extended up to the outside dimension of the coil using magnetic steel nose pieces. This design increases the effective length of the dipole without increasing the physical length. These nose pieces can be tailored to adjust the integral transfer function as well as the homogeneity of the integrated field. One prototype of each dipole type has been fabricated to validate the designs and to study matching of the two dipoles. A Hall probe mapping system has been built with three Group 3 Hall probes mounted on a 2-D translation stage. The probes are arranged with one probe in the midplane of the magnet and the others vertically offset by {+-}10 mm. The field is mapped around a nominal 25 m radius beam trajectory. The results of measurements in the as-received magnets, and with modifications made to the nose pieces are presented.

43 PARTICLE ACCELERATORS↗

The evolution of the mass-transfer functions in liquid Yukawa systems

The results of analytic and numerical investigation of mass-transfer processes in nonideal liquid systems are reported. Calculations are performed for extended 2D and 3D systems of particles that interact with a screened Yukawa-type Coulomb potential. The main attention is paid to 2D structures. A new analytic model is proposed for describing the evolution of mass-transfer functions in systems of interacting particles, including the transition between the ballistic and diffusion regimes of their motion.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

From noise to information: The transfer function formalism for uncertainty quantification in reconstructing the nuclear density

The neutron distribution of neutron-rich nuclei provides critical information on the structure of finite nuclei and neutron stars. Parity violating experiments—such as PREX and CREX—provide a clean and largely model-independent determination of neutron densities. Such experiments, however, are challenging and expensive, which is why sound statistical arguments are required to maximize the information gained. We introduce a new framework, the “transfer function formalism,” aimed at uncertainty quantification, model selection, and experimental design in the context of neutron densities. The transfer functions (TFs) are built analytically by expressing the linear response of the objective function (e.g., χ2) to small perturbations of the data. Using the TF formalism, we are able to analyze the expected overall uncertainty—quantified in terms of bias and variance—of the mean square radius and interior density of 48 Ca and 208 Pb. Using relativistic mean field models as a proxy for the weak-charge density—and assuming that a total of five measurements could be performed on the weak form factor of 48 Ca and 208 Pb—we identify the optimal models and experimental locations that minimize the uncertainty in the extraction of the radius and interior density. We also explore the use of the TF formalism to understand the influence of prior distributions for the model parameters, as well as the optimization of model hyperparameters not constrained by the data. Here,we establish how the choice of experimental locations and the model that is used can have a significant impact on the final uncertainties of the extracted quantities of interest. For challenging experiments such as CREX and PREX, a proper quantification of such uncertainties is critical. We have demonstrated how the TF formalism provides several advantages for this type of analysis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗