A High-Performance Superconducting Tunnel Junction (STJ) Soft X-ray Detector for Biological Science
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Small-area (1x1 sq micron) high-current-density NbN-MgO-NbN tunnel junctions with I-V characteristics suitable for high frequency mixers were fabricated. These junctions are integrated with superconducting microstrip lines designed to resonate out the large junction capacitance. The mixer gain and noise performance were studied near 205 GHz as a function of the inductance provided by the microstrip. This has yielded values of junction capacitance of 85 fF/sq microns and magnetic penetration depth of 3800 angstroms. Mixer noise as low as 133 K has been obtained for properly tuned junctions. This is the best noise performance ever reported for an NbN SIS mixer.
Small area (less than 1 sq micron), high-current-density NbN/MgO/NbN tunnel junctions with I-V characteristics suitable for high-frequency mixers have been fabricated. Mesa-geometry junctions with an area of about 1 sq micron and critical current density of 5-10 kA/sq cm are integrated with superconducting microstrip lines designed to resonate out the junction capacitance. A study was made of the mixer gain and noise performance near 205 GHz as a function of the inductance provided by the microstrip line. This has confirmed, at a high millimeter-wave frequency, values of junction capacitance of 85 fF/sq micron and recently measured values of a magnetic penetration depth of 380 nm. Mixer noise temperatures as low as 134 K at 1.5 K have been obtained for properly tuned junctions. A significant improvement in mixer performance on cooling from 4.2 K to 1.5 K was observed. Edge-geometry junctions with an area of 0.3 sq microns and critical current density of 18-25 kA/sq cm have also been fabricated. These junctions give a mixer noise temperature of 145 K at 4.2 K without the use of integrated tuning elements. These are the best results ever achieved for NbN-based SIS mixers.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The development and construction of an ultralow noise heterodyne receiver for millimeter wave astronomy is described along with its use for 115.3 GHz Co line observations. The receiver uses a Superconductor-Insulator-Superconductor (SIS) quasiparticle tunnel junction mixer to convert the millimeter wave signal to a microwave intermediate frequency. Experiments aimed at quantitative verification of J. R. Tucker's quantum mixer theory are studied, to see whether it could be used as the basis for the design of a practical receiver. The experimental results were in excellent agreement with the theory, assuming the three frequency approximation. Infinite available gain and negative output resistance were observed for the first time, nonclassical effects which are not seen in conventional diode mixers. Using Tucker's theory, an SIS receiver was then designed and constructed. At 115 GHz, the single sideband receiver noise temperature is 83K, the lowest ever reported in this frequency range. A CO survey toward Cygnus-X region, using this SIS receiver on the Columbia-GISS 4 ft. telescope, is also described.
The design, fabrication, and testing of a quasi-particle tunnel junction receiver for use at 345 GHz are discussed. The design employs small area Nb/Nb-oxide/PbInAu edge junctions in order to keep the device capacitance small and maintain a modest value for omega R(N)C. For optimum noise performance and beam properties the mixer is contained in a waveguide mounting structure. The best sensitivity was obtained at 312 GHz where a double sideband (DSB) noise temperature of 275 K was measured. Noise temperatures of 400 K (DSB) or better were obtained out to 350 GHz.
Superconductor-Insulator-Superconductor (SIS) diodes are the detector elements in the most sensitive heterodyne receivers available from 100 to 500 GHz. SIS mixers are the front end of radio astronomical systems around the world. SIS mixer technology is being extended to 1 THz and higher frequencies for eventual use on spaceborne astronomical experiments. Here is a short review of submillimeter SIS mixers. The role of impedance matching in the proper design of an SIS mixer is described. A variety of methods for achieving good impedance match at submillimeter frequencies are presented. The experimental state of the submillimeter SIS mixer art is described and summarized.
A heterodyne mixer with a micromachined horn antenna and a superconductor-insulator- superconductor (SIS) tunnel junction as mixing element is tested in the W-band (75-115 GHz) frequency range. Micromachined integrated horn antennas consist of a dipole antenna suspended on a thin Si(3)N(4) dielectric membrane inside a pyramidal cavity etched in silicon. The mixer performance is optimized by using a backing plane behind the dipole antenna to tune out the capacitance of the tunnel junction. The lowest receiver noise temperature of 30 +/- 3 K (without any correction) is measured at 106 GHz with a 3-dB bandwidth of 8 GHz. This sensitivity is comparable to the state-of-the-art waveguide and quasi-optical SIS receivers, showing the potential use of micromachined horn antennas in imaging arrays.
A heterodyne mixer with a micromachined horn antenna and a superconductor-insulator-superconductor (SIS) tunnel junction as mixing element is tested in the W-band (75-115 GHz) frequency range. Micromachined integrated horn antennas consist of a dipole antenna suspended on a thin Si3N4 dielectric membrane inside a pyramidal cavity etched in silicon. The mixer performance is optimized by using a backing plane behind the dipole antenna to tune out the capacitance of the tunnel junction. The lowest receiver noise temperature of 30 +/- 3 K (without any correction) is measured at 106 GHz with a 3-dB bandwidth of 8 GHz. This sensitivity is comparable to the state-of-the-art waveguide and quasi-optical SIS receivers, showing the potential use of micromachined horn antennas in imaging arrays.
We have developed a low-noise 850 GHz superconductor-insulator-superconductor (SIS) quasi-particle mixer with NbTiN thin-film microstrip tuning circuits and hybrid Nb/AlN/NbTiN tunnel junctions. The mixer uses a quasioptical configuration with a planar twin-slot antenna feeding a two-junction tuning circuit. At 798 GHz, we measured an uncorrected double-sideband receiver noise temperature of T(sub RX) = 260 K at 4.2 K bath temperature. This mixer outperforms current Nb SIS mixers by a factor of nearly 2 near 800 GHz. The high gap frequency and low loss at 800 GHz make NbTiN an attractive material with which to fabricate tuning circuits for SIS mixers. NbTiN mixers can potentially operate up to the gap frequency, 2(delta)/h is approximately 1.2THz.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment uses superconducting tunnel junction (STJ) sensors to search for physics beyond the standard model (BSM) with recoil spectroscopy of the 7 Be EC decay into 7 Li. A pulsed UV laser is used to calibrate the STJs throughout the experiment with ∼20 meV precision. Phase-III of the BeEST experiment revealed a systematic calibration discrepancy between STJs. We found these artifacts to be caused by resistive crosstalk and by intensity variations of the calibration laser. For phase-IV of the BeEST experiment, we have removed the crosstalk by designing the STJ array so that each pixel has its own ground wire. We now also use a more stable UV laser for calibration. The new STJ arrays were fabricated at STAR Cryoelectronics and tested at LLNL and FRIB. They have the same high energy resolution of ∼1-2~eV in the energy range of interest below 100~eV as before, and they no longer exhibit the earlier calibration artifacts. We discuss the design changes and the STJ array performance for the next phase of the BeEST experiment.
Supersonic wind tunnel electromagnetic balance with superconducting coils
Initial operational characteristics of a wind tunnel electromagnetic balance utilizing superconducting coils are reported. Both dc and ac superconducting coils are used for balancing and measuring 3-component aerodynamic forces on simple models in Mach 3, room temperature flow. Liquid helium boil-off measurements corresponding to a wide range of operating conditions are presented together with results of systematic ac losses scaling experiments using various pancake coils wound with superconducting tape. This unique prototype facility is primarily for studying the practical feasibility of using superconducting magnetic suspension techniques for aerodynamic testing and accumulating the knowledge and expertise required for extrapolating these techniques to large-scale facilities.
We have directly measured non-equilibrium quasiparticle tunnelling in the time domain as a function of temperature and RF carrier power for a pair of charge qubits based on the single Cooper-pair box, where the readout is performed with a multiplexed quantum capacitance technique. We have extracted an effective electron temperature for each applied RF power, using the data taken at the lowest power as a reference curve. This data has been fit to a standard T? electron heating model, with a reasonable correspondence with established material parameters.
The Beryllium Electron capture in Superconducting Tunnel junctions (BeEST) experiment searches for evidence of heavy neutrino mass eigenstates in the nuclear electron capture decay of 7 Be by precisely measuring the recoil energy of the 7 Li daughter. In Phase III, the BeEST experiment has been scaled from a singl superconducting tunnel junction (STJ) sensor to a 36-pixel array to increase sensitivity and mitigate gamma-induced backgrounds. Phase III also uses a new continuous data acquisition system that greatly increases the flexibility for signal processing and data cleaning. Here, we have developed procedures for signal processing and spectral fitting that are sufficiently robust to be automated for large datasets. Furthermore, this article presents the optimized procedures before unblinding the majority of the Phase III dataset to search for physics beyond the standard model.