Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Superconductive tunneling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of Ta-based Superconducting Tunnel Junction X-ray Detectors for Fluorescence XAS

We are developing superconducting tunnel junction (STJ) soft X-ray detectors for chemical analysis of dilute samples by fluorescence-detected X-ray absorption spectroscopy (XAS). Our 36-pixel Nb-based STJ spectrometer covers a solid angle {Omega}/4{pi}{approx_equal}10{sup -3}, offers an energy resolution of {approx}10-20 eV FWHM for energies up to {approx}1 keV, and can be operated at total count rates of {approx}10{sup 6} counts/s. For increased quantum efficiency and cleaner response function, we have now started the development of Ta-based STJ detector arrays. Initial devices modeled after our Nb-based STJs have an energy resolution below 10 eV FWHM for X-ray energies below 1 keV, and pulse rise time discrimination can be used to improve their response function for energies up to several keV. We discuss the performance of the Ta-STJs and outline steps towards the next-generation of large STJ detector arrays with higher sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of quasiparticle multi-tunneling on the energy flow through the superconducting tunnel junction

Superconducting tunnel junction (STJ) detector consists of two layers of superconducting material separated by thin insulating barrier. An incident particle produces in superconductor excess nonequilibrium quasiparticles. Each quasiparticle in superconductor should be considered as quantum superposition of electron-like and hole-like excitations. This duality nature of quasiparticle leads to the effect of multi-tunneling. Quasiparticle starts to tunnel back and forth through the insulating barrier. After tunneling from biased electrode quasiparticle loses its energy via phonon emission. Eventually, the energy that equals to the difference in quasiparticle energy between two electrodes is deposited in the signal electrode. Because of the process of multi-tunneling, one quasiparticle can deposit energy more than once. In this work, the theory of branching cascade processes was applied to the process of energy deposition caused by the quasiparticle multi-tunneling. The formulae for the mean value and variance of the energy transferred by one quasiparticle into heat were derived. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multilayered approach to superconducting tunnel junction x ray detectors

'First generation' superconducting tunnel junction X-ray detectors (characterized by a single tunnel junction in direct contact with its substrate, with totally external amplification) remain more than an order of magnitude away from their theoretical energy resolutions which are in the order of eV's. The difficulties that first generation devices are encountering are being attacked by a 'second generation' of superconducting X-ray detector designs including quasiparticle trapping configurations and Josephson junction arrays. A second generation design concept, the multilayered superconducting tunnel junction X-ray detector, consisting of tens to hundreds of tunnel junctions stacked on top of one another (a superlattice), is presented. Some of the possibilities of this engineered materials approach include the tuning of phonon transmission characteristics of the material, suppression of parasitic quasiparticle trapping and intrinsic amplification.

Rippert, E. D.↗

Subgap biasing of superconducting tunnel junctions without a magnetic field

Superconducting tunnel junctions (STJs) have been successfully used as single-photon detectors but require the use of a magnetic field to operate. A recent paper has proposed the idea to use a circuit of three junctions in place of a single junction in order to achieve the necessary biasing without applying a magnetic field. The nonlinear interaction between the different junctions in the circuit causes the existence of a stable subgap state for one of the junctions, which acts as the detector junction. In this paper, we present the first measurements demonstrating the existence of such a biasing state feasible for STJ detectors. Single junction measurements with an applied magnetic field help determine the functional form of the subgap current versus voltage; then the operating point of a three-junction circuit is measured and fit to theory. The excellent match between theory and experiment demonstrates the existence of the subgap biasing state. The outlook for possible use in detector applications is discussed.

36 MATERIALS SCIENCE↗

Characterization of Non-uniformities in Superconducting Tunnel Junction Radiation Detectors

The small dimensions of superconducting tunnel junction (STJ) radiation detectors have motivated the development of STJ arrays to increase detection efficiency and statistical accuracy. We have used a pulsed UV laser and X-rays to characterize and understand non-uniformities in the response of different pixels in Ta-based STJ arrays. To separate the contributions of the detector and the readout electronics, we have also injected the pulses from an arbitrary waveform generator into the array’s amplifier chain. We discuss the magnitude and the sources of the non-uniformity and approaches to reduce it.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Anatomy of Protein Electrospray Ionization Mass Spectra by Superconducting Tunnel Junction Mass and Energy Spectrometry

Cryogenic superconducting tunnel junction (STJ) detectors have the advantage of single-particle sensitivity, high quantum efficiency, low noise, and the ability to detect the time and relative impact energy of deposited ions. This makes them attractive for use in mass spectrometry (MS) and as a form of energy spectrometry. STJ cryodetectors have been coupled to time-offlight (TOF) mass spectrometers equipped with a matrix-assisted laser desorption ionization (MALDI) source and to an electrospray ionization (ESI) TOF mass spectrometer. Here, a lab-made linear ion trap (LIT) mass spectrometer system was coupled to an ESI source and a 16-channel Nb-STJ array with improved readout electronics. The goal was to investigate fundamentals of ESI-generated protein ions by further exploiting the advantage of resolving these ions in a third dimension of the relative energy deposited into the STJs. The proteins equine cytochrome c, bovine carbonic anhydrase, bovine serum albumin, and murine immunoglobulin G were studied using this ESI-LIT-STJ-MS instrument. Multiply charged monomers, multimers, and fragments from metastable ions were resolved from monomer peaks by differences in ion deposition energy even when these ions have the same mass-to-charge ratio as the corresponding monomer. The determination of fragment mass from metastable decomposition is accomplished without knowing the charge state of the fragment. The average charge state of the multimers is reduced with each addition of a protein which is a direct reflection of the surface area available for charging. Multiply charged in-source fragments have also been observed and distinguished in the mass spectrum of carbonic anhydrase by using the differences in the energy deposited in the STJs.

42 ENGINEERING↗

Direct Measurement of the Be 7 L / K Capture Ratio in Ta-Based Superconducting Tunnel Junctions

We report a high-statistics measurement of the L / K orbital electron capture ratio in 7 Be embedded in cryogenic Ta. The thin Ta film formed part of a high-resolution superconducting tunnel junction radiation detector that was used to identify the signals from different decay channels. The measured L/K capture ratio of 0.070(7) is significantly larger than the only previous measurement of this quantity and the theoretical predictions that include in-medium effects. This value is a uniquely sensitive probe of the 1s and 2s orbital overlaps with the nucleus and is of relevance to nuclear and atomic physics, as well as Li production in novae and other astrophysical scenarios. Furthermore, this is the first experiment that uses superconducting tunnel junctions for nuclear-recoil detection, opening a new experimental avenue for low-energy precision measurements with rare isotopes.

6 ≤ A ≤ 19↗

Final Scientific/Technical Report: Electronics for Large Superconducting Tunnel Junction Detector Arrays for Synchrotron Soft X-ray Research

Superconducting tunnel junction (STJ) detectors offer a an approach to detecting soft x-rays with energy resolutions 4-5 times better and at rates 10 faster than traditions semiconductor detectors. To make such detectors feasible, however, then need to be deployed in large arrays of order 1000 detectors, which in turn implies that their processing electronics must be compact, fully computer controlled, and low cost per channel while still delivering ultra-low noise performance so as to not degrade the STJ's performance. We report on our progress in designing a compact, low cost preamplifier intended for this application. In particular, we were able to produce a prototype preamplifier of 2 sq-cm area and a parts cost of less than $30 that matched the energy resolution of the best conventional system to date and demonstrated its ability to acquire an STJ I-V curve under computer control, the critical step for determining and setting the detectors' operating points under software control.

47 OTHER INSTRUMENTATION↗

A Superconducting Tunnel Junction X-ray Spectrometer without Liquid Cryogens

Superconducting tunnel junctions (STJs) are being developed as X-ray detectors because they combine the high energy resolution of cryogenic detector technologies with the high count rate capabilities of athermal devices. We have built STJ spectrometers for chemical analysis of dilute samples by high-resolution soft X-ray spectroscopy at the synchrotron. The instruments use 36 pixels of 200 {micro}m x 200 {micro}m Nb-Al-AlOx-Al-Nb STJs with 165 nm thick Nb absorber films. They have achieved an energy resolution of {approx}10-20 eV FWHM for X-ray energies below 1 keV, and can be operated at a total count rate of {approx}10{sup 6} counts/s. For increased user-friendliness, we have built a liquid-cryogen-free refrigerator based on a two-stage pulse tube cryocooler in combination with a two-stage adiabatic demagnetization stage. It holds the STJ detector at the end of a 40-cm-long cold finger, and attains the required operating temperature of {approx}0.3 K at the push of a button. We describe the instrument performance and present speciation measurements on Eu dopant activators in the novel scintillator material SrI{sub 2} to illustrate the potential for STJ spectrometers at the synchrotron.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Superconducting Tunnel Junctions for High-Precision EUV Spectroscopy

We have characterized the photon response of superconducting tunnel junctions in the extreme ultraviolet energy range below 100 eV with a pulsed 355 nm laser. The detectors are operated at rates up to 5000 counts/s, are very linear in energy and have an energy resolution between 0.9 and 2 eV. Here, we observe multiple peaks that correspond to an integer number of photons with a Poissonian probability distribution and that can be used for high-accuracy energy calibration. The uncertainty of the centroid depends on the detector resolution and the counting statistics and can be as low as 1 meV for well-separated peaks with > 10 5 counts. We discuss the precision of the peak centroid as a function of detector resolution and total number of counts and the accuracy of the energy calibration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Method for producing edge geometry superconducting tunnel junctions utilizing an NbN/MgO/NbN thin film structure

A method for fabricating an edge geometry superconducting tunnel junction device is discussed. The device is comprised of two niobium nitride superconducting electrodes and a magnesium oxide tunnel barrier sandwiched between the two electrodes. The NbN electrodes are preferably sputter-deposited, with the first NbN electrode deposited on an insulating substrate maintained at about 250 C to 500 C for improved quality of the electrode.

Hunt, Brian D.↗

A Liquid-Cryogen-Free Superconducting Tunnel Junction X-ray Spectrometer for Astrobiology Research at the Synchrotron

Superconducting tunnel junctions (STJs) are being developed as energy-dispersive soft X-ray detectors, because they combine the high energy resolution of low-temperature detectors with the comparably high count rates of non-thermal devices. We have built a 36-pixel spectrometer based on 200 {micro}m x 200 {micro}m Nb-Al-AlOx-Al-Nb STJs. It offers an energy resolution of {approx}10 to 20 eV FWHM in the soft X-ray band below 1 keV, a solid angle coverage {Omega}/4{pi} {approx} 10{sup -3}, and can be operated at total rates up to {approx}10{sup 6} counts/s. For STJ operation by non-expert users, we have built a liquid-cryogen-free spectrometer with a mechanical pulse-tube cryocooler and a two-stage adiabatic demagnetization refrigerator. It is fully automated for cooldown to a base temperature of <30 mK in 15 hours, and has a hold time of >3 days between demagnetization cycles for STJ operation at 0.3 K. The STJ spectrometers are used for speciation measurements on dilute samples by fluorescence-detected X-ray absorption spectroscopy, and can achieve sensitivities below 100 ppm. We discuss the spectrometer performance in representative applications on metals in meteorites in the context of geological signatures of biological activity.

36 MATERIALS SCIENCE↗

Nonequilibrium transport in superconducting tunneling structures.

We derive the current-voltage (I-V) characteristics of far from equilibrium superconducting tunneling arrays and find that the energy relaxation ensuring the charge transfer occurs in two stages: (i) the energy exchange between charge carriers and the intermediate bosonic agent, environment, and (ii) relaxing the energy further to the (phonon) thermostat, the bath, provided the rate of the environmental modes-phonon interactions is slower than their energy exchange rate with the tunneling junction. For a single junction we find I {proportional_to} (V/R)ln({Lambda}/V), where R is the bare tunnel resistance of the junction and {Lambda} is the high energy cut-off of the electron-environment interaction. In large tunneling arrays comprised of macroscopic number of junctions, low-temperature transport is governed by the cotunneling processes losing energy to the electron-hole environment. Below some critical temperature, T*, the Coulomb interactions open a finite gap in the environment excitations spectrum blocking simultaneously Cooper pair and normal excitations currents through the array; this is the microscopic mechanism of the insulator-to-superinsulator transition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Antenna-Coupled Superconducting Tunnel Junctions with Single-Electron Transistor Readout for Detection of Sub-mm Radiation

Antenna-coupled superconducting tunnel junction detectors have the potential for photon-counting sensitivity at sub-mm wavelengths. The device consists of an antenna structure to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure currents through tunnel junction contacts to the absorber volume. We will describe optimization of device parameters, and recent results on fabrication techniques for producing devices with high yield for detector arrays. We will also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.↗

Method and apparatus for evaluating superconducting tunnel junction detector noise versus bias voltage

A technique for characterizing the noise behavior of a superconducting tunnel junction (STJ) detector as a function of its applied bias voltage Vb by stepping the STJ's bias voltage across a predetermined range and, at each applied bias, making multiple measurements of the detector's current, calculating their mean and their standard deviation from their mean, and using this standard deviation as a measure of the STJ detector's noise at that applied bias. Because the method is readily executed under computer control, it is particularly useful when large numbers of STJ detectors require biasing, as in STJ detector arrays In a preferred implementation, the STJ is measured under computer control by attaching it to a digital spectrometer comprising a digital x-ray processor (DXP) coupled to a preamplifier that can set the STJ's bias voltage Vb using a digital-to-analog converter (DAC) controlled by the DXP.

Warburton, William K.↗

Superconducting Tunneling Spectroscopy of Spin-Orbit Coupling and Orbital Depairing in Nb : SrTiO 3

We have examined here the intrinsic spin-orbit coupling and orbital depairing in thin films of Nb-doped ${\mathrm{SrTiO}}_{3}$ by superconducting tunneling spectroscopy. The orbital depairing is geometrically suppressed in the two-dimensional limit, enabling a quantitative evaluation of the Fermi level spin-orbit scattering using Maki's theory. The response of the superconducting gap under in-plane magnetic fields demonstrates short spin-orbit scattering times ${{\tau}}_{\mathrm{so}}{\le}1.1\text{ }\text{ }\mathrm{ps}$. Analysis of the orbital depairing indicates that the heavy electron band contributes significantly to pairing. These results suggest that the intrinsic spin-orbit scattering time in ${\mathrm{SrTiO}}_{3}$ is comparable to those associated with Rashba effects in ${\mathrm{SrTiO}}_{3}$ interfacial conducting layers and can be considered significant in all forms of superconductivity in ${\mathrm{SrTiO}}_{3}$.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Development of Superconducting Tunnel Junction Far-Infrared Photon Detector for Cosmic Background Neutrino Decay Search - COBAND experiment

We present the status of development of the Superconducting Tunnel Junction (STJ) detector for the COsmic BAckground Neutrino Decay search (COBAND) experiment. The signal of the cosmic background neutrino decay is identified as a sharp cutoff at high energy end in a far-infrared region ranging from 15meV to 30meV in the energy spectrum of the photons from the space. The COBAND experiment will be done as rocket and satellite experiments in order to detect the far-infrared photons from the space. For the photon detector of the COBAND experiment, we are developing the STJ detectors. We will use a combination of the diffraction grating and the array of Nb/Al-STJ pixels with cryogenic amplifier for the rocket experiment, and use Hf-STJ without a grating for the future satellite experiment. The present status of the detector R&D and the experimental design for the COBAND experiment is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗