Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Subcooled Liquid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

98 records · Page 2

Highly Porous Polyimide Gel for Use as Battery Separator with Room Temperature Ionic Liquid Electrolytes

Advanced aerospace vehicular concepts require advances in many existing technologies, including space power and energy storage systems. Batteries represent one of the major areas in need of improvement, both in terms of energy density and safety, with growing concerns over the fire safety of commercial lithium-ion batteries. This has prompted efforts to develop nonflammable battery components, namely the electrolyte and separator. Existing commercial lithium-ion batteries utilize polyolefin microporous membranes as separators with an electrolyte consisting of a lithium salt dissolved in a mixture of cyclic carbonate solvents. This separator/electrolyte combination has ionic conductivities in the range of 10 −2 to 10 −3 S/cm. However, the cyclic carbonate solvents are inherently flammable. Room-temperature ionic liquids (RTILs) appear to be a safer alternative. They offer good ionic conductivities and are inherently nonvolatile and nonflammable, giving them a safety advantage. However, many promising RTILs for battery electrolytes are not compatible with commercial polyolefin separator materials. Alternative separator materials, such as polyimides, are non-flammable and are capable of accepting RTILs into their structure. Polyimide gels, with a composition of 4,4′-oxydianiline, 3,3′,4,4′-tetracarboxylic dianhydride and cross-linked with Desmodur N3300A, possess an open-porous, fibrillar network architecture which offers a high degree of porosity (typically greater than 85% porosity) for lithium-ion transport and conduction, as well as good mechanical properties. Furthermore, these polyimide gels are compatible with selected imidazolium-based RTILs. Nonflammable separator/electrolyte systems with room-temperature conductivities in the range of 10 −3 S/cm have been evaluated. It has been demonstrated that 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide was the most promising among six RTILs screened, in terms of both ionic conductivity and constant current cycling.

Polyimide

Analysis of Gas Absorption to A Thin Liquid Film in the Presence of A Zero-Order Chemical Reaction

The paper presents a detailed theoretical analysis of the process of gas absorption to a thin liquid film adjacent to a horizontal rotating disk. The film is formed by the impingement of a controlled liquid jet at the center of the disk and subsequent radial spreading of liquid along the disk. The chemical reaction between the gas and the liquid film can be expressed as a zero-order homogeneous reaction. The process was modeled by establishing equations for the conservation of mass, momentum, and species concentration and solving them analytically. A scaling analysis was used to determine dominant transport processes. Appropriate boundary conditions were used to solve these equations to develop expressions for the local concentration of gas across the thickness of the film and distributions of film height, bulk concentration, and Sherwood number along the radius of the disk. The partial differential equation for species concentration was solved using the separation of variables technique along with the Duhamel's theorem and the final analytical solution was expressed using confluent hypergeometric functions. Tables for eigenvalues and eigenfunctions are presented for a number of reaction rate constants. A parametric study was performed using Reynolds number, Ekman number, and dimensionless reaction rate as parameters. At all radial locations, Sherwood number increased with Reynolds number (flow rate) as well as Ekman number (rate of rotation). The enhancement of mass transfer due to chemical reaction was found to be small when compared to the case of no reaction (pure absorption), but the enhancement factor was very significant when compared to pure absorption in a stagnant liquid film. The zero-order reaction processes considered in the present investigation included the absorption of oxygen in aqueous alkaline solutions of sodiumdithionite and rhodium complex catalyzed carbonylation of methanol. Present analytical results were compared to previous theoretical results for limiting conditions, and were found to have very good agreement.

S Rajagopalan

Analytical Model for Steady Flow through a Finite Channel with One Porous Wall with Arbitrary Variable Suction or Injection

This paper presents an exact solution of two-dimensional laminar flow through a finite length channel with one porous wall. It improves upon previous solutions by (1) satisfying the no-slip boundary condition at the channel dead end, (2) adding a turbulent term to the porous wall boundary condition, (3) allowing for arbitrary variable suction or injection across the porous wall, and (4) model validation against new cryogenic liquid hydrogen and oxygen experimental data. Of particular interest in the current work is the modeling of cryogenic propellant flow through a porous liquid acquisition device (LAD) screen and channel inside a propellant tank. First, a detailed review of the literature is presented for previously attempted solutions to channel flow with one porous wall. Next, the governing equations, boundary conditions, and model assumptions are used to derive the analytical flow solution and present general model results for pressure and velocity fields within the channel. Then, the model solution is compared with horizontal LAD channel flow data in liquid oxygen as well as vertical LAD channel flow data in an inverted outflow configuration in liquid hydrogen. Model results are used to update the static cryogenic bubble point pressure model with a dynamic bubble point term which factors in enhanced convection and cooling at the screen during propellant outflow. Convective heat transfer at the LAD screen during outflow is also quantified by comparing model and data. The new analytical flow solution with the dynamic bubble point model is shown to compare well with available cryogenic experimental data

Navier Stokes Equations

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Spacesuit

Performance Evaluation of Intravehicular Activity Spacesuit Without the Use of a Liquid Cooling Garment

The Orion Crew Survival Systems (OCSS) suit is equipped with safety technology that protects the crew during launch and re-entry and Intravehicular Activities (IVA). It was designed to be used with a Liquid Cooling Garment (LCG), an undergarment with tubes that circulate water to remove excess heat from a crew member. The objective of this study is to determine if the Modified Advanced Crew Escape Suit (MACES), which has very similar material, assembly, and pressure characteristics as the OCSS suit, can be used without the LCG to maintain the crew within their heat storage requirements where exceedances can lead to cognitive and physiological impairment. Testing was completed for both hot and cold environments where test subjects wore varying configurations of the MACES suit ensemble without the LCG. The tests were conducted in a temperature and humidity-controlled chamber with four test subjects ranging from extra small to large. Target metabolic rates were reached using an arm ergometer. To represent the different suit configurations seen in the concept of operations, the suit was tested with visor-down, visor-up, and without helmet and gloves. The test data was analyzed to determine how the environment, test subject size, metabolic rate, and suit configuration affected heat storage. Furthermore, the test data was used to correlate the METMAN model, a transient metabolic man program that simulates the heat transfer within a crew member’s body and from a crew member to the surrounding environment. The METMAN correlation showed good agreement between predicted heat storage and test data at the end of the test duration, with a coefficient of determination (R 2 ) value of 0.8999 for visor-down cases and R 2 of 0.8902 for visor-up and helmet off cases. A correlated METMAN model allows for the analysis and prediction of IVA suit performance without an LCG in additional scenarios.

Human Thermal Modeling

Experimental Effervescence and Freezing Point Depression Measurements of Nitrogen in Liquid Methane-Ethane Mixtures

NASA is designing an unmanned submarine to explore the depths of the hydrocarbon-rich seas on Saturn’s moon Titan. Data from Cassini indicates that the Titan north polar environment sustains stable seas of variable concentrations of ethane, methane, and nitrogen, with a surface temperature near 93 K. The submarine must operate autonomously, study atmosphere/sea exchange, interact with the seabed, hover at the surface or any depth within the sea, and be capable of tolerating variable hydrocarbon compositions. Currently, the main thermal design concern is the effect of effervescence on submarine operation, which affects the ballast system, science instruments, and propellers. Twelve effervescence measurements on various liquid methane-ethane compositions with dissolved gaseous nitrogen are thus presented from 1.5 bar to 4.5 bar at temperatures from 92 K to 96 K to simulate the conditions of the seas. After conducting effervescence measurements, two freezing point depression measurements were conducted. The freezing liquid line was depressed more than 15 K below the triple point temperatures of pure ethane (90.4 K) and pure methane (90.7 K). Experimental effervescence measurements will be used to compare directly with effervescence modeling to determine if changes are required in the design of the thermal management system as well as the propellers.

Freezing Point Depression

Lyotropic Liquid Crystalline Phase Behavior of Boron Nitride Nanotube Aqueous Dispersions

Boron nitride nanotubes (BNNTs) are gaining significant interest due to their outstanding mechanical and thermal properties, as well as their potential to serve as a model nanorod system. Processing BNNT liquid crystalline (LC) dispersions enables precise control over BNNT orientation in macroscopic assemblies, while their low absorption in the visible spectrum facilitates studying LCs at exceptionally high concentrations. Here, we investigate the behavior of BNNTs in aqueous solutions stabilized by the surfactant sodium deoxycholate (SDC), examining the effect of BNNT purity and BNNT−SDC concentrations on lyotropic LC formation. We disperse up to 15wt% BNNT in SDC solutions and use polarized light microscopy to detail the transition from an isotropic state to a biphasic regime, where isotropic and nematic domains coexist due to phase separation, to a single fully nematic phase. Cryogenic electron microscopy provides direct evidence of BNNT alignment within nematic domains. Our results show that enhanced depletion-induced attractions, driven by increased surfactant concentration, lower the threshold concentration of BNNT required to form nematic domains. In contrast, low surfactant concentrations relative to BNNT result in insufficiently coated nanotube surfaces, leading to poor dispersions and BNNT aggregation. Additionally, we fabricate well-aligned BNNT films from aqueous LC dispersions. Our findings advance the understanding of BNNT LCs, offering insight into controlling their orientation and highlighting their potential for high-performance materials.

Joe Khoury

High-density Boron Nitride Nanotube Composites via Surfactant-stabilized Lyotropic Liquid Crystals for Enhanced Space Radiation Shielding

Despite significant technological advancements in space exploration, human space travel and colonization remain limited by the health risks associated with space radiation. Boron nitride nanotubes (BNNTs) have been proposed as an advanced material for space applications due to their high specific strength and efficient radiation shielding capabilities. However, the practical implementation of BNNTs has been slow, primarily due to technological challenges in fabricating structural materials incorporating BNNTs. In this study, a method is presented for fabricating high-density BNNT films that are mechanically robust, exhibit high thermal conductivity, and effectively attenuate space radiation. The key advancement enabling high-density BNNT films is the successful preparation of BNNT liquid crystals (LCs), achieved through the strategic use of a commercial dodecylbenzenesulfonic acid surfactant. This surfactant ensures exceptional BNNT stability in aqueous dispersion, even at concentrations exceeding the LC phase transition threshold. Simulations, estimating the equivalent radiation dose to the human body in space, indicate that a high-density BNNT film with a surface density of 50 g cm−2 reduces the total dose equivalent rate by 56% compared to zero shielding. This enhancement would allow astronauts to extend their mission duration on the lunar surface by a factor of two.

Young-Kyeong Kim

Behavior of Ullage Bubbles During Blowdown in Low-g Experiment (BUBBLE): Overview of a Cryogenic Tank Depressurization Test

Behavior of Ullage Bubbles during Blowdown in Low-g Experiment (BUBBLE) is a cryogenic tank depressurization drop tower experiment currently being designed at NASA Glenn Research Center. There is a need for liquid level rise data while venting a cryogenic propellant tank below the liquid saturation pressure in a reduced gravity environment. When a cryogenic tank is vented to a vapor pressure below the liquid saturation pressure, bubbles become entrained in the liquid causing the bulk liquid-vapor interface to rise. In reduced gravity, bubble rise velocity is diminished leading to a larger liquid level rise compared to a 1g environment. The purpose of the experiment is to gain further understanding of tank depressurization fluid physics and obtain high-fidelity data for model validation in 1g and reduced gravity environments. On-orbit cryogenic propellant tanks operating at high fill levels must efficiently manage venting operations to avoid the risk of liquid entrainment in the vent line, which could lead to asymmetric control thruster loads, freezing and clogging, and loss of liquid propellant. Validated models could be used to design settling and venting profiles to reduce risk and increase efficiency for cryogenic storage and transfer operations.

tank venting

Thermal-Fluid Analysis of a Liquid-Cooled Battery Module for Electrified Aircraft

The development of safe, energy-dense batteries is critical to advancing hybrid electric and fully electrified aircraft propulsion. Achieving this capability requires a thermal management system that can maintain battery performance and safety under demanding operational conditions. The objective of this project is to support the maturation of next-generation lithium-ion batteries for electrified aircraft by conducting performance testing on integrated battery modules, specifically a 2-cell series configuration module housed within an aluminum enclosure. Designed to operate at a nominal 7.2 V with discharge rates up to 2.5C, the module will eventually be used to power an electric motor and DC-DC converter, generating substantial thermal loads that must be effectively managed to increase the usable energy and power density of electrified aircraft. To address these thermal challenges, this study presents the development and thermal-fluid analysis of a liquid-cooled thermal management system. While the full aircraft architecture utilizes an eight-string configuration, the present work evaluates a representative single-string water coolant loop to characterize baseline performance. The active cooling loop circulates water through a reservoir, pump, the battery module, and a variable area flow meter. Key performance metrics including component-level temperatures, mass flow rates, and pressure drops are quantified across the loop. Across discharge rates ranging from 0.5C to 2.5C, the active thermal loop consistently and effectively removed heat from the module, validating the design approach and confirming readiness for further development. The validated thermal performance indicates a path toward scalable battery modules that could enable energy and power dense systems for hybrid electric aircraft.

Electrified Aircraft

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Cryocooler

Characterization Testing of a 20 Kelvin Cryocooler for Space Applications

Future NASA space exploration missions will require long-duration storage and liquefaction of cryogenic liquids, enabled by active cooling provided by cryocoolers. Recent gap analyses of Lunar and Mars transportation systems have identified 20 K-class cryocoolers as a critical enabling technology for chemical and nuclear thermal propulsion architectures using liquid hydrogen propellant. To address this technology gap, NASA has undergone the development of a high-efficiency, high-capacity 20 K cryocooler via an SBIR partnership with Creare. While the January 2025 testing demonstrated functionality and compliance with contractual requirements, the objective of the NASA-led characterization effort was to generate a dataset for supporting future mission designs across a broader operating envelope, including off-nominal conditions. The cryocooler demonstrated strong performance, achieving a peak coefficient of performance of 17.68% relative to Carnot efficiency and a maximum lift capacity of 24.4 W at 21 K. Overall, the results confirm that the 20 W 20 K cryocooler provides a flexible range of capabilities to enable zero boil-off storage of liquid hydrogen for future Lunar and Mars missions. The data collected provide a strong foundation for model validation and future system design efforts.

Zero boil-off

Core-Centering of Compound Drops in Capillary Oscillations: Observations on USML-1 Experiments in Space

Using the existing inviscid theories, an attempt is made to explain the centering of the oscillating liquid shell. Experiments on liquid shells and liquid-core compound drops were conducted using acoustic levitation, in a low-gravity environment during a Space Shuttle flight. It was observed that their inner and outer interfaces became concentric when excited into capillary oscillations. Using the existing inviscid theories, and attempt is made to explain the centering of the oscillating liquid shell. It is concluded that viscosity needs to be considered in order to provide a realistic description of the centering process.

T G Wang

Numerical Modeling of the Transient Chilldown Process of a Cryogenic Propellant Transfer Line

Before cryogenic fuel depots can be fully realized, efficient methods with which to chill down the spacecraft transfer line and receiver tank are required. This paper presents numerical modeling of the chilldown of a liquid hydrogen tank-to-tank propellant transfer line using the Generalized Fluid System Simulation Program (GFSSP). To compare with data from recently concluded turbulent LH2 chill down experiments, seven different cases were run across a range of inlet liquid temperatures and mass flow rates. Both trickle and pulse chill down methods were simulated. The GFSSP model qualitatively matches external skin mounted temperature readings, but large differences are shown between measured and predicted internal stream temperatures. Discrepancies are attributed to the simplified model correlation used to compute two-phase flow boiling heat transfer. Flow visualization from testing shows that the initial bottoming out of skin mounted sensors corresponds to annular flow, but that considerable time is required for the stream sensor to achieve steady state as the system moves through annular, churn, and bubbly flow. The GFSSP model does adequately well in tracking trends in the data but further work is needed to refine the two-phase flow modeling to better match observed test data.

Temperature Sensors

Cryogenic Spray Quenching of A Simulated Propellant Storage Tank Wall With Heat Transfer Enhancement By A Thin-Film Coating and Flow Pulsing in Microgravity

Human space exploration to the Moon, Mars, and possibly asteroids is NASA’s biggest challenge for the new millennium. One of the critical elements to this mission is the effective, sufficient, and reliable supply of cryogenic propellant fluids. Future lower-earth-orbiting (LEO) propellant fuel depots and human-carrying orbital transfer spacecraft flying to the moon and Mars will have to utilize the high thrust and high efficiency of liquid cryogenic chemical propulsion or nuclear thermal propulsion. Efficient in-space tank-to-tank propellant transfer (propellant fuel depot to orbital transfer spacecraft) of cryogenic propellants is an enabling technology for the planned Crewed Mars Surface Mission. The transfer of cryogenic propellants in space, however, has yet to be accomplished, solely due to the unavailability of cryogenic quenching heat transfer data during chilldown (quenching) and filling of the propellant receiver tank in reduced gravity and microgravity as liquid propellant cannot be stored in a required liquid state until the tank is quenched down to the liquid temperature. Therefore, highly energy efficient thermal-fluid management breakthrough concepts to conserve and minimize the cryogen consumption during propellant transfer have become the focus of research and engineering development, especially for the deep-space mission to Mars. In this paper, we introduce such concepts and demonstrate their feasibility for cryogenic storage tank chilldown in parabolic flights under a simulated space microgravity condition. In order to maximize the storage tank chilldown efficiency for the least amount of cryogen consumption, the technology adopted included cryogenic spray cooling, Teflon thin-film coating of the simulated tank surface, and spray flow pulsing. The completed flight experiments successfully demonstrated that spray cooling is the most efficient cooling method for the tank chilldown in microgravity. In microgravity, Teflon coating alone can improve the efficiency up to 72% and the efficiency can be improved up to 59% by flow pulsing alone. However, Teflon coating together with flow pulsing was found to substantially enhance the chilldown efficiency in microgravity for up to 113%.

spray

Transient Studies of G-Induced Capillary Dryout and Rewet

A transient, one-dimensional numerical code is developed to model the liquid motion in an axial groove with square cross section. Axial variation in liquid level, shear stress and heat transfer between the groove wall and the liquid, evaporation and transient body forces are accounted for in the model. Dryout and rewet of the groove are allowed; the front location is determined numerically using conservation of mass and linear extrapolation. Several numerical test results are presented and discussed.

M K Reagan

Numerical Predictions of the Flow and Heat Transfer Characteristics in the Film Boiling Regime During Tube Quenching

Cryogenic fluid management plays a major role in refueling of spacecrafts while in space for NASA’s future human space exploration missions. Due to the low boiling points of cryogens, storage, transport and handling of these fluids becomes difficult and may result in inefficient operation of the space propulsion systems. For refueling applications in space, the cryogenic fluids have to be transported across different locations and hence, the transfer of cryogenic fluids through pipes become critical. The cryogenic chill-down process is characterized by different regimes of flow boiling, viz., film boiling, transition boiling and nucleate boiling. The prediction of these regimes in a single CFD framework available in the literature is challenging and the present work attempts to address this challenge by initially modeling the film boiling regime accurately and to incorporate an user-defined function for transition and nucleate boiling at a later stage. Hence, the aim of the present work is to numerically model and validate the film boiling regime of the chilldown curve for liquid nitrogen experiments available in the literature. The validations are carried out at different inlet mass fluxes to have a robust simulation methodology. A dispersed mixture model is used to predict the vapor-liquid interface dynamics with the phase change phenomena modeled using the Lee model.

line chilldown

Decoupling Surface Topography from Gravitational Acceleration in Cryogenic Pool Boiling

Boiling heat transfer is governed by a complex interplay between surface conditions and gravitational acceleration. To isolate the sole effects of gravity, we investigated the pool boiling characteristics of liquid nitrogen on atomically smooth silicon dioxide (SiO 2 ) surfaces under terrestrial (1-g) and reduced gravity (0±0.02 g) conditions achieved via parabolic flight. Our results quantify a drastic reduction in the critical heat flux (CHF) in reduced gravity, decreasing from 16.15 W/cm 2 at 1-g to 5−6 W/cm 2 at μ-g due to the suppression of buoyancy. Conversely, we observed a distinct increase in the heat transfer coefficient (HTC) in the reduced gravity condition prior to CHF. By utilizing a surface with a maximum peak-to-valley height of ≈36.7 nm and low contact angle hysteresis (<10°), we confirm this HTC enhancement is an intrinsic response to the gravitational environment, decoupled from surface-defect-induced nucleation. These findings demonstrate that the influence of surface topography is significantly more prominent in reduced gravity than in terrestrial conditions, providing a critical baseline for rationalizing the design of cryogenic thermal management systems in space and quantum applications.

Liquid nitrogen