At least 37 records · Page 2

Constraining the Low-Temperature Oxidation Mechanism of n -Hexanol through the Detection and Identification of C 6 Elusive Intermediates

Alcohol-based fuels are currently considered to be viable energy carriers for the transportation sector. Consequently, a comprehensive mechanistic understanding of the low-temperature oxidation of alcohols is essential for application in advanced low-temperature compression engines. Here, in this work, a multidimensional approach involving experimental investigations, kinetic modeling, and theoretical calculations was used to provide new insights into the low-temperature oxidation mechanism of a C 6 alcohol, n -hexanol (CH 3 (CH 2 ) 5 OH), through the detection and identification of elusive C 6 intermediates. The oxidation of n-hexanol was investigated in a jet-stirred reactor under stoichiometric conditions (ϕ = 1.0), an initial fuel concentration of 2%, a residence time of 2 s, a temperature range between 500 and 660 K, and a pressure of 700 Torr. The reactants, intermediates, and final products were detected and identified by means of molecular-beam mass spectrometry coupled with single-photon ionization employing tunable synchrotron-generated vacuum ultraviolet radiation. Chemical kinetic simulations were performed using a previously published kinetic model (Togbé et al., Energy Fuels 2010, 11, 5859−5875) to predict the reactivity of n-hexanol and elucidate the predominant formation pathways of the observed low-temperature species. Experimental photoionization efficiency curves in conjunction with ab initio calculations, enabled the identification of important low-temperature species, such as C 6 unsaturated alcohols, C 6 olefinic hydroperoxides, C 6 cyclic ethers, C 6 diones, and C 6 ketohydroperoxides. The results of this study provide valuable insight into the mechanism of the low-temperature oxidation chemistry of n -hexanol, contributing to the development of kinetic models for the low-temperature oxidation of n-hexanol and other long-chain linear alcohols.

alcohols↗

Undulator radiation of single electrons: coherence length and quantum-optical properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Undulator Radiation of Single Electrons: Coherence Length and Quantum-Optical Properties

The aims of the CLARA experiment at the Fermilab Integrable Optics Test Accelerator (IOTA) were to directly measure the coherence length of undulator radiation emitted by a single electron and to test whether the radiation is in a pure classical Glauber coherent state or in a quantum mixture of coherent and Fock states. We used a Mach-Zehnder interferometer (MZI) to study visible radiation generated by 150-MeV electrons circulating in the ring. The relative delay between the two arms of the MZI was adjusted by varying the length of one of them with a resolution of 10 nm. The intensity of the circulating beam spanned several orders of magnitude, down to single electrons. A pair of single-photon avalanche diodes (SPADs) was placed at the output of the MZI arms to detect photocounts with high efficiency and timing resolution. We describe the observed interference patterns and photocount rates as a function of interferometer delay and discuss their implications.

43 PARTICLE ACCELERATORS↗

Low-Temperature Non-Oxidative Coupling of Methane on Atomically Dispersed Titanium–Aluminum–Boron Nanopowder

Nonoxidative coupling of methane represents a long-standing challenge in heterogeneous catalysis, as it requires activation of the carbon–hydrogen (C–H) bond, controlled carbon–carbon (C–C) bond formation, and effective hydrogen management without relying on oxidants. Here, we report a low-temperature C–H activation and nonoxidative C–C coupling of methane over atomically dispersed titanium–aluminum–boron nanopowder (Ti–Al–B NP) utilizing a catalytic microreactor coupled to synchrotron single-photon photoionization reflectron time-of-flight mass spectrometry. The soft-ionization, in situ probing method detects the nascent reaction products and radical intermediates under operando conditions, including methyl radical, C2 hydrocarbons, and molecular hydrogen. Methane activation is initiated at 800 K, approximately 700 K below the gas-phase decomposition threshold, leading predominantly to ethylene formation with selectivity reaching up to 78% among the C–C coupled products. Electronic structure calculations on model Ti–Al–B clusters elucidate a cooperative catalytic mechanism in which titanium enables methane adsorption and C–H activation, boron acts as a reversible hydrogen reservoir, and aluminum stabilizes methylene intermediates, thereby facilitating selective C–C coupling and dehydrogenation. These findings establish a distinct catalyst architecture for nonoxidative methane coupling based on earth abundant elements alternative to expensive platinum and other noble metal-containing conventional catalysts and provide molecular-level design principles for controlling dehydrogenation and subsequent C–C bond formation in challenging light alkane conversions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatio-spectral quantum state estimation of photon pairs from optical fiber using stimulated emission

Developing a quantum light source that carries more than one bit per photon is pivotal for expanding quantum information applications. Characterizing a high-dimensional multiple-degree-of-freedom source at the single-photon level is challenging due to the large parameter space as well as limited emission rates and detection efficiencies. Here, we characterize photon pairs generated in optical fiber in the transverse-mode and frequency degrees of freedom by applying stimulated emission in both degrees of freedom while detecting in one of them at a time. This method may be useful in the quantum state estimation and optimization of various photon-pair source platforms in which complicated correlations across multiple degrees of freedom may be present.

Kim, Dong Beom (ORCID:0000000346887375)↗

Temperature-dependent characterization of large-area superconducting microwire array with single-photon sensitivity in the near-infrared

Superconducting nanowire single photon detectors (SNSPDs) are a leading detector technology for time-resolved single-photon counting from the ultraviolet to the near-infrared regime. The recent advancement in single-photon sensitivity in micrometer-scale superconducting wires opens up promising opportunities to develop large area SNSPDs with applications in low background dark matter detection experiments. Here, we present the first detailed temperature-dependent study of a 4-channel 1×1 mm 2 WSi superconducting microwire single photon detector (SMSPD) array, including the internal detection efficiency, dark count rate, and importantly the coincident dark counts across pixels. The detector shows saturated internal detection efficiency for photon wavelengths ranging from 635 nm to 1650 nm, time jitter of about 160 ps for 1060 nm photons, and a low dark count rate of about 10 -2 Hz. Additionally, the coincidences of dark count rate across pixels are studied for the first time in detail, where we observed an excess of correlated dark counts, which has important implications for low background dark matter experiments. The results presented is the first step towards characterizing and developing SMSPD array systems and associated background for low background dark matter detection experiments.

47 OTHER INSTRUMENTATION↗

Orchestrating Spontaneous Emission With Metasurfaces: Recent Advances in Engineering Thermal, Luminescent, and Quantum Emissions

Metasurfaces have emerged as powerful tools for controlling spontaneous emission, offering unprecedented control over light-matter interactions at sub-wavelength scales. While metasurfaces are traditionally utilized for shaping coherent electromagnetic waves, they have recently extended their capabilities to control incoherent or spontaneous emission. This examines review how metasurfaces can enhance and precisely control properties of thermal, luminescent, and quantum emission. In thermal emission, metasurfaces enable control over spatial, temporal, and spin coherence, offering new possibilities for applications such as energy harvesting, radiative cooling and heat assisted ranging and detection. For luminescent emission, metasurfaces significantly improve emission rates, quantum efficiency, and directionality, driving innovations in lighting and display technologies. For controlling quantized spontaneous emission, metasurfaces are instrumental in enhancing single-photon sources and enabling novel functionalities in quantum states through photon-pair generation, which is vital for quantum communication, meteorology, and computing. Here, despite these advancements several challenges to increase the operational bandwidths, accelerate and develop simulation strategies, and fabrication complexities persist. Emerging trends are also discussed, such as dynamic metasurfaces and their integration with nanophotonic platforms, which could further expand the capabilities of light-emitting metasurfaces.

Luminescence↗

Studies of LAPPD and HRPPD photodetectors for Cherenkov imaging applications

HRPPDs are the baseline single-photon sensors for a classic proximity-focusing RICH (pfRICH) counter, one of the Cherenkov radiation-based PID subsystems of the ePIC detector at the EIC. We report SPE time resolution of 87 ps rms for an LAPPD unit detecting Cherenkov photons in a quartz lens at a CERN PS test beam (2022). We also present the degradation and partial recovery of gain and relative efficiency of an LAPPD unit as a function of the B-field strength (up to 1.5 T) and angular orientation, measured with vertical dipole magnets at CERN (2023–2024). Finally, we report preliminary results of an accelerated ageing study performed on an HRPPD unit in Trieste laboratory (2025).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advances in detection for neutron reflectometry with time-resolved imaging detectors

Thermal neutron detection in neutron scattering science is a challenging endeavour due to a limited number of technologies which are sensitive to these weakly interacting particles. While many improvements to conventional detectors are underway at various facilities, there is a great opportunity to make a leap in performance by combining the spatial resolution benefits of imaging and the temporal resolution and background discrimination of event-driven radiation detectors. This idea has been realized by using a neutron sensitive scintillator read out by a single-photon sensitive camera based on a Timepix3 ASIC. We demonstrate how such data-driven imaging sensors can enable unprecedented performance in neutron reflectometry using the ASTERIX instrument at the Los Alamos Neutron Scattering Center. Several samples were measured with both the new and a conventional 3 He detector systems. The results from this work demonstrate that these imaging based systems can satisfy performance parameters for the future QIKR reflectometer to be built at the Second Target Station at Oak Ridge National Laboratory. Further improvements to the detector are already underway which will allow streamlined and expedited experiments. We demonstrate at least a two order of magnitude increase in detection rate at an acceptable dead time and introduce a new way of tuning the detector efficiency using light collecting optics to accommodate highly intense direct beams which cannot be measured with any current detectors without severe attenuation. This will allow measurements of complete reflectometry profiles and using a single sample measurement combined with fewer direct beam calibration measurements on QIKR and potentially other reflectometers.

36 MATERIALS SCIENCE↗

Multiphoton and Harmonic Imaging of Microarchitected Materials

Microadditive manufacturing has revolutionized the production of complex, nano- to microscale components across various fields. This work investigates two-photon (2P) and three-photon (3P) fluorescence imaging, as well as third-harmonic generation (THG) microscopy, to examine periodic microarchitected lattice structures fabricated using multiphoton lithography (MPL). By immersing the structures in refractive index matching fluids, we demonstrate high-fidelity 3D reconstructions of both fluorescent structures using 2P and 3P microscopy as well as low-fluorescence structures using THG microscopy. These results show that multiphoton fluorescence (MPF) imaging offers reduced signal decay with respect to depth compared to single-photon techniques in the examined structures. We further demonstrate the ability to nondestructively identify intentional internal modifications of the structure that are not immediately visible with scanning electron microscope (SEM) images and compression-induced fractures, highlighting the potential of these techniques for quality control and defect detection in microadditively manufactured components.

36 MATERIALS SCIENCE↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

Generation of a fluorescent short-lifetime oxygen nanosensor by coupling of an exciplex forming dye pair

Typical oxygen-sensitive dyes have lifetimes in the μs-ms regime for sensitive oxygen detection based on molecular quenching. Due to the long triplet-state lifetimes and poor quenching efficiency of these probes, it has been difficult to develop short lifetime probes. We have developed oxygen sensors using a short-lifetime dye (∼30–60 ns) that forms an anthracene-aniline exciplex, which is quenched by molecular oxygen through an excited-state charge transfer mechanism. To achieve measurements in aqueous systems, we have tethered the dyes together via a C3 alkyl linker to facilitate greater exciplex formation at low dye concentration (20 μg mL −1 ) and encapsulated the resulting compound into polymeric nanoparticles to form an aqueous-dispersible short-lifetime oxygen nanosensor. The sensors emit at 420 nm (unfolded dye) and 500 nm (exciplex), and the ratiometric Stern-Volmer Constant is 1.52 ± 0.02 L mol −1 , showing good sensitivity from 0 % to 40 % dissolved oxygen without the tradeoff of a long lifetime needed for direct molecular quenching. In this paper, we characterize this sensor for both lifetime-based measurements using time-correlated single-photon counting and ratiometric intensity-based measurements using the unfolded dye emission as an internal reference peak.

Biological and medical sciences↗

Enhancing spectroscopy and microscopy with emerging methods in photon correlation and quantum illumination

Quantum optics has led to important advancements in our ability to prepare and detect correlations between individual photons. Its principles are increasingly translated into nanoscale characterization tools, furthering methods in spectroscopy, microscopy and metrology. Here, in this Review, we discuss the rapid progress in this field driven by advanced technologies of single-photon detectors and quantum-light sources, including time-resolved single-photon counting cameras, superconducting nanowire single-photon detectors and entangled photon sources of increasing brightness. We emphasize emerging applications in super-resolution microscopy, measurements below classical noise limits and photon-number-resolved spectroscopy—a powerful paradigm for the characterization of nanoscale electronic materials. We conclude by discussing key technological challenges and future opportunities in materials science and bionanophotonics alike.

Tsao, Chieh [University of California, Berkeley, C↗

Enhancing the Cherenkov over scintillation ratio using dichroic filters in BGO and TlCl for TOF-PET

Abstract The Cherenkov emission in inorganic crystal scintillators has been shown to dramatically improve time resolution for time-of-flight positron emission tomography (TOF-PET) for in slow scintillators with a high refractive index such as bismuth germanium oxide (BGO). This is due to the faster nature of the Cherenkov emission (tens of picoseconds) with respect to scintillation (nanosecond). However, the presence of slower scintillation light and the inability of existing detectors to distinguish between Cherenkov and scintillation make it difficult for BGO to achieve a good CTR for all the detected coincidence events. In this paper, we exploit the difference between the Cherenkov and scintillation emission spectra and use dichroic filters to enhance the Cherenkov over scintillation ratio. Dichroic filters transmit or reflect photons based on their wavelength, with a photon attenuation lower than 10%. We investigate several shortpass and longpass dichroic filters in a single-photon configuration with BGO and find the optimal filter that maximizes the Cherenkov over scintillation ratio. We demonstrate that we can enhance the ratio of Cherenkov to scintillation photons by a factor of 2.17 ± 0.38 by employing a shortpass dichroic filter with a cut-off wavelength of 450 nm for BGO, and by a factor of 2.87 ± 0.40 using a longpass dichroic filter with a cut-on wavelength of 550 nm for iodine/beryllium-doped thallium chloride.

Science & Technology - Other Topics↗

Anomaly detection with flow-based fast calorimeter simulators

Recently, several normalizing flow-based deep generative models have been proposed to accelerate the simulation of calorimeter showers. Using caloflow as an example, we show that these models can simultaneously perform unsupervised anomaly detection with no additional training cost. As a demonstration, we consider electromagnetic showers initiated by one (background) or multiple (signal) photons. The caloflow model is designed to generate single-photon showers, but it also provides access to the shower likelihood. We use this likelihood as an anomaly score and study the showers tagged as being unlikely. As expected, the tagger struggles when the signal photons are nearly collinear but is otherwise effective. This approach is complementary to a supervised classifier trained on only specific signal models using the same low-level calorimeter inputs. While the supervised classifier is also highly effective at unseen signal models, the unsupervised method is more sensitive in certain regions, and, thus, we expect that the ultimate performance will require a combination of these approaches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Highly excited electron cyclotron for QCD axion and dark-photon detection

We propose using highly excited cyclotron states of a trapped electron to detect meV axion and dark-photon dark matter, marking a significant improvement over our previous proposal and demonstration [One-electron quantum cyclotron as a milli-ev dark-photon detector, .]. When the axion mass matches the cyclotron frequency ω c , the cyclotron state is resonantly excited, with a transition probability proportional to its initial quantum number, n c . The sensitivity is enhanced by taking n c ∼ 10 6 ( 0.1 meV ω c ) 2 . By optimizing key experimental parameters, we minimize the required averaging time for cyclotron detection to t ave ∼ 10 − 6 s, permitting detection of such a highly excited state before its decay. An open–end-cap trap design enables the external photon signal to be directed into the trap, rendering our background-free detector compatible with large focusing cavities, such as the BREAD proposal, while capitalizing on their strong magnetic fields. Furthermore, the axion conversion rate can be coherently enhanced by incorporating layers of dielectrics with alternating refractive indices within the cavity. Collectively, these optimizations enable us to probe the QCD axion parameter space from 0.1 to 2.3 meV (25–560 GHz), covering a substantial portion of the predicted postinflationary QCD axion mass range. This sensitivity corresponds to probing the kinetic mixing parameter of the dark photon down to ε ≈ 2 × 10 − 16 . Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Millimeter-Wave Superconducting Qubit

Manipulating the electromagnetic spectrum at the single-photon level is fundamental for quantum experiments. In the visible and infrared ranges, this can be accomplished with atomic quantum emitters, and with superconducting qubits such control is extended to the microwave range (below 10 GHz). Meanwhile, the region between these two energy ranges presents an unexplored opportunity for innovation. We bridge this gap by scaling up a superconducting qubit to the millimeter-wave range (near 100 GHz). Working in this energy range greatly reduces sensitivity to thermal noise compared to microwave devices, enabling operation at significantly higher temperatures, up to 1 K. This has many advantages by removing the dependence on rare 3⁢ He for refrigeration, simplifying cryogenic systems, and providing orders-of-magnitude higher cooling power, lending the flexibility needed for novel quantum sensing and hybrid experiments. Using low-loss niobium trilayer junctions, we realize a qubit at 72 GHz cooled to 0.87 K using only 4 ⁢He. We perform Rabi oscillations to establish control over the qubit state, and measure relaxation and dephasing times of 15.8 and 17.4 ns, respectively. This demonstration of a millimeter-wave quantum emitter offers exciting prospects for enhanced sensitivity thresholds in high-frequency photon detection, provides new options for quantum transduction and for scaling up and speeding up quantum computing, enables integration of quantum systems where 3 ⁢He refrigeration units are impractical, and, importantly, paves the way for quantum experiments exploring a novel energy range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of High Speed Optical and Magnetic Interactions in Superconducting Nanowire Single Photon Detectors

Single-photon detectors are essential tools for quantum photonics. The ideal single photon detector would exhibit a quantum efficiency (QE) of 100% (i.e. no false negatives), zero dark photon counts per second (i.e. no false positives), zero dead time (i.e. the detector is capable of detecting one photon immediately after another), and zero jitter (i.e. the electrical signal produced by the detector perfectly reproduces the timing of the input photon signal). Commercially available avalanche photodiodes (APDs) have generally performed reasonably well for visible wavelengths but they perform poorly at longer wavelengths. For wavelengths spanning the near- ultraviolet (UV) to the mid- infrared (IR), superconducting nanowire single photon detectors (SNSPDs) can exhibit quantum efficiencies exceeding 90% with dark count rates and timing jitter roughly an order of magnitude less than is typically seen in APDs. While SNSPDSs are now commercially available from several small businesses, fundamental questions about the nature of photon interactions with superconducting nanostructures remain.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗