Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Single particle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The free-electron laser - Maxwell's equations driven by single-particle currents

It is shown that if single particle currents are coupled to Maxwell's equations, the resulting set of self-consistent nonlinear equations describes the evolution of the electron beam and the amplitude and phase of the free-electron-laser field. The formulation is based on the slowly varying amplitude and phase approximation, and the distinction between microscopic and macroscopic scales, which distinguishes the microscopic bunching from the macroscopic pulse propagation. The capabilities of this new theoretical approach become apparent when its predictions for the ultrashort pulse free-electron laser are compared to experimental data; the optical pulse evolution, determined simply and accurately, agrees well with observations.

Colson, W. B.

Single-particle detection of enhanced polarizability in Au-decorated semiconducting nanorods via scanning dielectric microscopy

Hybrid nanostructures that combine semiconducting and metallic components offer great potential for photothermal therapy, optoelectronics, and sensing, by integrating tunable optical properties with enhanced light absorption and charge transport. Boosting the integrated performance of these hybrid systems demands techniques capable of probing local variations of the physical properties inaccessible to bulk analysis. Here, we report the single-particle dielectric characterization of hybrid, semiconducting bismuth sulfide (Bi 2 S 3 ) nanorods (NR) decorated with metallic Au nanoparticles (NP), employing scanning dielectric microscopy, which uses electrostatic force microscopy in combination with finite-element numerical simulations. We reveal a pronounced enhancement in the local dielectric response of Bi2S3 upon Au decoration, attributed to interfacial polarization and electron transfer from Au to the Bi 2 S 3 matrix, thus suggesting a enhanced metallic-like polarizability at the single-particle level. Numerical simulations show that the response is dominated by the vertical component of the permittivity and that the decorating metallic Au NP produce only moderate shielding of the semiconductor Bi 2 S 3 NR core, indicating that the large increase in the dielectric response originates primarily from intrinsic modifications within the NR. Overall, these findings provide direct insight into structure–property relationships at the single-particle level, supporting the rational design of advanced hybrid nanostructures with tailored electronic functionalities.

36 MATERIALS SCIENCE

Single-particle chemical analysis reveals organic-rich detonation soot products

The detonation of high explosives produces a wide variety of particulate matter (PM) with distinct properties, not all of which are traditionally studied for chemical composition, formation processes, and forensic applications. We report particle-resolved measurements of Composition B detonation soot using soot particle aerosol mass spectrometry (SP-AMS), identifying carbonaceous species and metals not previously characterized on a single-particle basis. Results are combined with scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) to enhance source-dependent signatures. Black carbon, including graphitic carbon and detonation nanodiamonds, contributed 50.5-71.4% of PM 2.5 mass, while 22.5-43.4% was non-refractory organic carbon, a previously overlooked component that exhibited a complex and varying composition. Detonations were performed with and without PMMA confinement and under steady and overdriven conditions. Distinct particles enriched with polycyclic aromatic hydrocarbons (PAHs) were observed in experiments utilizing confinement, with quantities dependent on manufacturing method. SEM-EDS validated SP-AMS findings of metals internally mixed with carbonaceous species and extended the particle size range to 100 µm. This work makes detecting non-refractory organics using single-particle techniques more feasible for detonation forensics and understanding high-energy soot formation. While this analysis uses offline sample collection, SP-AMS could be deployed for in-situ measurements of detonation PM 2.5 transported in the atmosphere.

36 MATERIALS SCIENCE

Parameters Inference and Model Reduction for the Single-Particle Model of Li Ion Cells

The Single-Particle Model (SPM) of Li ion cell is a computationally efficient model for simulating Li ion cell for weak to moderate currents. The model depends n a number of parameters describing the geometry and material properties of a cell components. In order to apply the model to simulating a cell, the best-fit parametric values have to be inferred from a constant discharge data. We report our efforts to determine the best-fit set for 18650 LP batteries. We found that rather than being best-fit by a particular point in the parametric space the data is fit equally well by an ensemble of points clustering about an effective multidimensional manifold in the parametric space. This property of the SPM is known to be shared by a multitude of the so-called "sloppy models" of complex systems, characterized by a few stiff directions in the parametric space, in which the predicted behavior varies significantly, and a number of sloppy directions in which the behavior doesn't change appreciably. Only the stiff parameters combinations are identifiable. Geometrical features of the BFM give insights to possible reduction of the SPM to a model having fewer sloppy parameters. We have constructed a hierarchy of such models. The fully reduced model depends on only stiff effective parameters which are identifiable and can be used for characterization of the battery's state of health.

Khasin, Michael

A precise measurement of the jet energy scale derived from single-particle measurements and in situ techniques in proton–proton collisions at $\sqrt{s}=$ 13 TeV with the ATLAS detector

The jet energy calibration and its uncertainties are derived from measurements of the calorimeter response to single particles in both data and Monte Carlo simulation using proton–proton collisions at $\sqrt{s} = 13$ TeV collected with the ATLAS detector during Run 2 at the Large Hadron Collider. The jet calibration uncertainty for anti-$k_T$ jets with a jet radius parameter of R$_\textrm{jet} = 0.4$ and in the central jet rapidity region is about 2.5% for transverse momenta ($p_{\text {T}}$) of 20 $\text {GeV}$ , about 0.5% for $p_{\text {T}} = 300$ GeV and 0.7% for $p_{\text {T}} = 4$ TeV . Excellent agreement is found with earlier determinations obtained from -balance based in situ methods ($Z/\gamma$ +jets). The combination of these two independent methods results in the most precise jet energy measurement achieved so far with the ATLAS detector with a relative uncertainty of 0.3% at $p_\textrm{T} = 300$ GeV and 0.6% at 4 TeV. The jet energy calibration is also derived with the single-particle calorimeter response measurements separately for quark- and gluon-induced jets and furthermore for jets with R jet varying from 0.2 to 1.0 retaining the correlations between these measurements. Differences between inclusive jets and jets from boosted top-quark decays, with and without grooming the soft jet constituents, are also studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Single-Particle Isotopic Analysis Using the Liquid Sampling-Atmospheric Pressure Glow Discharge Microplasma Coupled to an Orbitrap Mass Spectrometer

Isotope ratio (IR) determinations on individual particles can provide valuable information relative to the sample, including processing and dating, which could be valuable to geological and nuclear material analysis communities. In comparison to “bulk” measurements, in which all particle information is lost and homogenized within a sample, “particle” measurements allow for fingerprinting and can provide unique insights related to the sample’s nano- and micro- compositions. Furthermore, the complex nature of particles, with potential isobaric interferences from either the matrix or other elements within the same particle, poses a significant analytical challenge for conventional mass spectrometry platforms employed for elemental analysis due to their limited mass resolution. Presented here is the first demonstration of an ultrahigh resolution method for single particle (SP) isotopic analysis using the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an Orbitrap mass spectrometer and FTMS Booster X2T acquisition/processing system. For proof of concept, well-characterized CeO 2 microparticles with a nominal diameter of 1.0 μm were analyzed at a mass resolution of ∼330,000. Important instrumental parameters were optimized to enable the detection of single particles. The 142 Ce/ 140 Ce ratio of individual particles and the population average were determined and compared to an SP inductively coupled plasma time-of-flight mass spectrometry (ICP-TOF-MS) analysis. The isotopic accuracy and precision were determined by two methods and found to be in good agreement with the SP-ICP-TOF-MS method, with the linear regression slope method providing a more accurate ratio, showing a ∼1.4% relative difference from the ratio determined from a particle digest. The encouraging performance of the method was further supported by a determined detection limit of 2.9 fg ( 142 Ce). The developed method is anticipated to overcome many of the challenges posed by isobaric interferences encountered in conventional mass spectrometry techniques when analyzing real-world samples for particle isotopic composition.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Leveraging machine learning to enhance aerosol classification using Single-Particle Mass Spectrometry

Advancing automated classification of atmospheric aerosols from Single-Particle Mass Spectrometry (SPMS) data remains challenging due to overlapping ion signatures, compositional diversity, and limited labeled data. This study evaluates supervised and semi-supervised learning frameworks to enhance aerosol identification by jointly leveraging labeled and unlabeled spectra. Four models were compared: a supervised Support Vector Machine (SVM), a self-training SVM, a stacked autoencoder classifier, and a stacked autoencoder trained using a temporal-ensembling Mean Teacher approach. All models achieved high and stable accuracies (90.0 %–91.1 %), surpassing previous results on the same dataset (87 %) and matching the performance of state-of-the-art deep learning methods. Despite small global metric differences (≤ 1 %), semi-supervised variants yielded up to 5 %–10 % improvements for compositionally rare particle types – such as soot (0.77 % of spectra, F1-score: 0.93–0.97) and hazelnut pollen (0.98 % of spectra, F1-score: 0.97–1.00) – equating to roughly ∼ 187 additional correctly classified spectra. These gains are scientifically significant, as such rare particles exert disproportionate influence on radiative absorption and ice nucleation processes; their improved detection reduces modeled uncertainties in aerosol absorption optical depth and mixed-phase cloud ice nucleation rates. The models' residual misclassifications (≈ 9 %) largely arise from true spectral overlap among chemically adjacent species (e.g., Na- vs. K-feldspar, coated vs. uncoated feldspars), reflecting physical compositional continuity rather than algorithmic error. Collectively, these findings demonstrate that leveraging unlabeled data to learn robust spectral representations and refine classification enhances both fidelity and interpretability, bridging data-driven analysis with aerosol–climate process understanding.

54 ENVIRONMENTAL SCIENCES

Microstructure-dependent particulate populations in ODS steels revealed by single-particle ICP-TOF-MS

In this work, we evaluated the ability of single-particle inductively coupled plasma time-of-flight mass spectrometry (SP-ICP-TOF-MS) to characterize particulates generated from 300 series stainless steels and oxide dispersion–strengthened (ODS) steels. Particulates were produced using two different rotary tools (cutting disk and grinding bit) to assess the influence of particle generation on effluent particulates. Across all materials and preparation techniques, SP-ICP-TOF-MS detected a substantial population of particles containing the expected constituent elements, with average compositions closely matching the nominal alloy values. A secondary population of Y-bearing particles was evident in ODS steels; their formation is strongly favored in particulates generated using the grinding bit. Specifically, in PM2000, Y-bearing particles were predominantly colocated with Al, whereas in 14YWT, Y-bearing particles were less frequently Fe-free but showed stronger colocation with Ti. These trends are consistent with the known microstructural differences between Y–Al–O oxide particles in PM2000 and finer Y–Ti–O nanoclusters in 14YWT. Together, these results demonstrate that SP-ICP-TOF-MS can resolve distinct particulate populations in complex, multicomponent steels at the femtogram mass scale, enabling particle-resolved insight into microstructure-driven phase separation and preparation-dependent particle generation.

Brubaker, Zach E. [Oak Ridge National Laboratory (

Calibration of single particle sizing velocimeters using photomask reticles

The development of photomask reticle calibration standards for single particle instruments is discussed. The calibration method studied involves the use of photomask reticles where the particle artifacts are actually disks of chrome thin film in the clear field reticles produced by photolithography and etching processes. Consideration is given to various aspects of theory, design, and performance.

Hirleman, E. D.

Quenching of single-particle strength inferred from nucleon-removal transfer reactions on 15 C

The difference in the proton and neutron separation energies (ΔS) of the weakly bound 15 C ground state is -19.86 MeV, an extreme value. Data from intermediate-energy heavy-ion induced (HI-induced) knockout reactions on nuclei spanning -20 ≲ ΔS ≲ +20 MeV, suggest that the degree to which single-particle strength is quenched, R s , has a negative correlation with ΔS, decreasing from unity around -20 MeV to around 0.2 at +20 MeV. For the 15 C ground state (R s = 0.96 (4) in HI-induced knockout), contrasting results have recently been obtained via the neutron-adding transfer reaction, which reveal a value of R s = 0.64 (15), similar to the value observed at modest and more extreme values of ΔS with reaction probes other than HI knockout. In order to explore the any potential differences between adding and removing processes in transfer reactions at extreme ΔS, single-neutron removal transfer reactions on 15 C were performed at 7.1 MeV/u in inverse kinematics. The removal of a valence neutron in 2s 1/2 orbit using both (p, d) and (d, t) reactions shows consistent quenching factors and agrees with those from the neutron-adding reaction. The present results, which can be compared with neutron knockout reaction, suggest that correlations, represented by the quenching factor, show limited dependence on neutron-proton asymmetry under the most extreme asymmetry conditions so far achieved in transfer reactions.

quenching factor

Single-Particle Measurements of Midlatitude Black Carbon and Light-Scattering Aerosols from the Boundary Layer to the Lower Stratosphere

A single-particle soot photometer (SP2) was flown on a NASA WB-57F high-altitude research aircraft in November 2004 from Houston, Texas. The SP2 uses laser-induced incandescence to detect individual black carbon (BC) particles in an air sample in the mass range of approx.3-300 fg (approx.0.15-0.7 microns volume equivalent diameter). Scattered light is used to size the remaining non-BC aerosols in the range of approx.0.17-0.7 microns diameter. We present profiles of both aerosol types from the boundary layer to the lower stratosphere from two midlatitude flights. Results for total aerosol amounts in the size range detected by the SP2 are in good agreement with typical particle spectrometer measurements in the same region. All ambient incandescing particles were identified as BC because their incandescence properties matched those of laboratory-generated BC aerosol. Approximately 40% of these BC particles showed evidence of internal mixing (e.g., coating). Throughout profiles between 5 and 18.7 km, BC particles were less than a few percent of total aerosol number, and black carbon aerosol (BCA) mass mixing ratio showed a constant gradient with altitude above 5 km. SP2 data was compared to results from the ECHAM4/MADE and LmDzT-INCA global aerosol models. The comparison will help resolve the important systematic differences in model aerosol processes that determine BCA loadings. Further intercomparisons of models and measurements as presented here will improve the accuracy of the radiative forcing contribution from BCA.

Schwartz, J. P.

FPGA-accelerated SpeckleNN with SNL for real-time X-ray single-particle imaging

We present the implementation of a specialized version of our previously published unified embedding model, SpeckleNN, for real-time speckle pattern classification in X-ray Single-Particle Imaging (SPI), using the SLAC Neural Network Library (SNL) on an FPGA platform. This hardware realization transitions SpeckleNN from a prototypic model into a practical edge solution, optimized for running inference near the detector in high-throughput X-ray free-electron laser (XFEL) facilities, such as those found at the Linac Coherent Light Source (LCLS). To address the resource constraints inherent in FPGAs, we developed a more specialized version of SpeckleNN. The original model, which was designed for broader classification across multiple biological samples, comprised ~5.6 million parameters. The new implementation, while reducing the parameter count to 64.6K (a 98.8% reduction), focuses on maintaining the model's essential functionality for real-time operation, achieving an accuracy of 90%. Furthermore, we compressed the latent space from 128 to 50 dimensions. This implementation was demonstrated on the KCU1500 FPGA board, utilizing 71% of available DSPs, 75% of LUTs, and 48% of FFs, with an average power consumption of 9.4W according to the Vivado post-implementation report. The FPGA performed inference on a single image with a latency of 45.015 microseconds at a 200 MHz clock rate. In comparison, running the same inference on an NVIDIA A100 GPU resulted in an average power consumption of ~73W and an image processing latency of around 400 microseconds. Our FPGA-accelerated version of SpeckleNN demonstrated significant improvements, achieving an 8.9 × speedup and a 7.8 × reduction in power consumption compared to the GPU implementation. Key advancements include model specialization and dynamic weight loading through SNL, which eliminates the need for time-consuming FPGA design re-synthesis, allowing fast and continuous deployment of models (re)trained online. These innovations enable real-time adaptive classification and efficient vetoing of speckle patterns, making SpeckleNN more suited for deployment in XFEL facilities. This implementation has the potential to significantly accelerate SPI experiments and enhance adaptability to evolving experimental conditions.

47 OTHER INSTRUMENTATION

Accelerators for critical experiments involving single-particle upset in solid-state microcircuits

Charged-particle interactions in microelectronic circuit chips (integrated circuits) present a particularly insidious problem for solid-state electronic systems due to the generation of soft errors or single-particle event upset (SEU) by either cosmic rays or other radiation sources. Particle accelerators are used to provide both light and heavy ions in order to assess the propensity of integrated circuit chips for SEU. Critical aspects of this assessment involve the ability to analytically model SEU for the prediction of error rates in known radiation environments. In order to accurately model SEU, the measurement and prediction of energy deposition in the form of an electron-hole plasma generated along an ion track is of paramount importance. This requires the use of accelerators which allow for ease in both energy control (change of energy) and change of ion species. This and other aspects of ion-beam control and diagnostics (e.g., uniformity and flux) are of critical concern for the experimental verification of theoretical SEU models.

Zoutendyk, J. A.