Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Silicon Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Proton Straggling in Thick Silicon Detectors

Straggling functions for protons in thick silicon radiation detectors are computed by Monte Carlo simulation. Mean energy loss is constrained by the silicon stopping power, providing higher straggling at low energy and probabilities for stopping within the detector volume. By matching the first four moments of simulated energy-loss distributions, straggling functions are approximated by a log-normal distribution that is accurate for Vavilov k is greater than or equal to 0:3. They are verified by comparison to experimental proton data from a charged particle telescope.

Selesnick, R. S.

Silicon Detector Studies with an Interferometric Thickness Mapper

Cosmic ray isotopic composition studies aboard satellites are normally based on energy detection measurements which require a precise knowledge of matter thickness particle penetration. A laser- interferometer system has been developed to precisely map the thick- ness variations of large-area silicon detectors. Design, operation, and the data processing to derive thickness maps is described.

Cosmic Rays Silicon Detectors Interferometry Satel

MeV Gamma Ray Detection Algorithms for Stacked Silicon Detectors

By making use of the signature of a gamma ray event as it appears in N = 5 to 20 lithium-drifted silicon detectors and applying smart selection algorithms, gamma rays in the energy range of 1 to 8 MeV can be detected with good efficiency and selectivity. Examples of the types of algorithms used for different energy regions include the simple sum mode, the sum-coincidence mode used in segmented detectors, unique variations on sum-coincidence for an N-dimensional vector event, and a new and extremely useful mode for double escape peak spectroscopy at pair-production energies. The latter algorithm yields a spectrum similar to that of the pair spectrometer, but without the need of the dual external segments for double escape coincidence, and without the large loss in efficiency of double escape events. Background events due to Compton scattering are largely suppressed. Monte Carlo calculations were used to model the gamma ray interactions in the silicon, in order to enable testing of a wide array of different algorithms on the event N-vectors for a large-N stack.

McMurray, Robert E. Jr.

The response of covered silicon detectors to monoenergetic gamma rays

Measurements were made of the efficiency in detecting gamma rays of a 0.3-mm, a 3-mm, and a 5-mm silicon detector covered with different absorbers. Calibrated sources covering the range from 279 KeV to 2.75 MeV were used. The need for the absorbers in order to obtain meaningful results, and their contribution to detector response at electron biases from 50 to 200 KeV, are discussed in detail. It is shown that the results are independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias setting is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.

The response of covered silicon detectors to monoenergetic gamma rays.

Measurements have been made of the efficiency in detecting gamma rays of a 0.3-mm-, 3-mm-, and 5-mm-thick silicon detector covered with different absorbers. Calibrated sources over the range from 279 keV to 2.75 MeV were used. The need for the absorbers to obtain meaningful results and their contribution to the response of the detectors at electron biases from 50 to 200 keV are discussed in detail. It is shown that the results are virtually independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias settings is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.

Pion studies with silicon detectors.

Most probable energy loss in silicon for pions with energies from 365 to 50 mev, examining pion beam behavior through different absorption material thicknesses

MUON

Characterization of Low-energy Ionization Signals in Silicon Detectors for the Nab Experiment

The Nab (Neutron a b) experiment is designed to measure the beta-antineutrino angular correlation in free neutron 𝛽 decay with an ultimate precision goal of 0.1%, providing input for tests of Cabibbo-Kobayashi-Maskawa matrix unitarity. This measurement is performed via detection of electrons and protons in delayed coincidence using custom large-area segmented silicon detectors. We present the characterization of one such detector system to establish the proton energy and timing response, using a dedicated proton accelerator. The detected proton peak was studied for 25, 30, and 35 keV incident protons on a set of detector segments and multiple cooling cycles over a one-year period. Ionization losses were consistent with models of the detector dead layer with thicknesses less than 100 nm. The detected proton peak was stable within the uncertainty from energy calibration (0.25 keV). The rise times of detector pulses from 109Cd and 113Sn conversion electron sources were used to extract the impurity density profile and establish a precise model for the detector timing response. The observed impurity density profile varied from (2±2)×109/cm3 at the center to (26±2)×109/cm3 at the edge. This impurity density profile was then used to characterize systematic effects in proton time-of-flight measurements due to detector pulse-shape effects; the resultant proton timing systematic uncertainties were below 0.3 ns, which is sufficient for the Nab experiment.

Taylor, RJ [North Carolina State University]

Thickness and uniformity mapping of thin foils using resistive silicon detectors

Alpha energy loss is a common tool used for measuring target thicknesses. However, these measurements are often made without position information, which either forfeits knowledge of material uniformity and local thickness or requires a prohibitive number of measurements per target to partially recover this information. In consideration of this, a method for measuring position-dependent thicknesses is described in this work; by using the position-sensitivity of the dual-axis duo-lateral (DADL) silicon detector, thicknesses across the entire face of the material can be measured to sub-mm precision with a single measurement. Several examples are presented using a number of targets with varying characteristics, which altogether demonstrate the precision, accuracy, and versatility of this technique.

Foil uniformity

Comparisons of LET distributions measured in low-earth orbit using tissue-equivalent proportional counters and the position-sensitive silicon-detector telescope (RRMD-III)

Determinations of the LET distribution, phi(L), of charged particles within a spacecraft in low-Earth orbit have been made. One method used a cylindrical tissue-equivalent proportional counter (TEPC), with the assumption that for each measured event, lineal energy, y, is equal to LET and thus phi(L) = phi(y). The other was based on the direct measurement of LETs for individual particles using a charged-particle telescope consisting of position-sensitive silicon detectors called RRMD-III. There were differences of up to a factor of 10 between estimates of phi(L) using the two methods on the same mission. This caused estimates of quality factor to vary by a factor of two between the two methods.

Flight Experiment

A 16 x 16 element extrinsic silicon detector array

Two bismuth-doped silicon accumulation-mode charge-injection device (AMCID) infrared detector arrays are studied. The geometry and composition of the arrays, and a description of the cold and warm electronics components of the system are described. Instructions for setting up and operating the array system, plus results of a functional test, are included.

Source record

Silicon Detector System for Cross Section Measurements

In order to estimate the radiation shielding effectiveness of materials it is necessary to know cosmic ray particles are broken up as they pass though these materials. The breakup of cosmic ray particles is characterized by the nuclear fragmentation cross sections, i.e. an effective geometrical cross section assigned to each target nucleus that represents its apparent size for fragmenting the incident particle. The values of these cross sections depend on the details of nuclear physics and cannot be calculated from first principles owing to the many-body nature of the interactions. The only way to determine them is to measure them. Once a sufficient number of cross sections have been measured, the systematic nature of the interactions allows other cross-sections to be estimated. The number of cross sections that contribute to the estimation of shielding effectiveness is very large 10,000. Fortunately most make minor contributions. These can be estimated from nuclear systematics. Only those who's uncertainties make significant contributions to the error in the shielding effectiveness estimations need to be measured. In the past it has proven difficult to measure light fragment production cross sections from the interactions of heavy cosmic rays owing to the size of the detectors used. We have developed a highly pixilated silicon (Si) detector system that can individually identify these light fragments while making efficient use of costly accelerator time. This system is an outgrowth of detector technology developed under a CDDF and a Code S sponsored cosmic ray experiment.

Source record

The FABLE silicon detector array for comprehensive studies of fusion and breakup dynamics

The Fusion and Breakup of Light Elements (FABLE) array, comprised of ΔE-E telescopes of neutron-transmutation doped (NTD) Double-Sided Silicon Strip Detectors (DSSDs), has been developed and commissioned for future experiments at the Facility for Rare Isotope Beams (FRIB). FABLE was designed to perform measurements of complete and incomplete fusion cross sections, to help address the interplay between breakup and clustering in outcomes of reactions with exotic nuclides. Here, the FABLE array has been commissioned in a comprehensive study at the ReAccelerator facility ReA6 of the Facility for Rare Isotope Beams (FRIB), investigating the dynamics in the weakly-bound proton rich 7 Be reaction on 208 Pb targets.

Breakup

Field Funneling and Range Straggling in Silicon Detectors

Magnitudes of field funneling and range straggling determined in silicon-surface-barrier (Schottky-barrier) charged-particle detectors (SSBD's) through meaurement of charges collected from alpha-particle tracks. Method used extended to straightforward measurement of charge collection from heavy-ion tracks in these and other semiconductor devices. Such measurements used to assess single-event upsets in integratedcircuit chips, with view toward making them resistant to radiation. Field funneling and range straggling measured with electronic system in which charge collected from individual ions measured and recorded by multichannel analyzer.

Zoutendyk, J. A.

Silicon Detectors For Helium Liquid And Vapor

Simple electrical-resistance devices made of silicon indicate whether helium liquid or helium vapor present. Devices designed primarily for use in outer space, were tested and found to operate in normal Earth gravity. Silicon cubes supported by stainless-steel wires and strips. Voltage across each cube at fixed current indicates whether immersed in helium liquid or vapor. Liquid cools more than vapor does, resulting in greater electrical resistance. Such helium-liquid/vapor detectors incorporated into ducts or containers of laboratory equipment, and used to infer locations of liquid/vapor interfaces in order to measure quantities of liquid and vapor or to control refill operations.

Di Pirro, M. J.

Collective excitations and low-energy ionization signatures of relativistic particles in silicon detectors

Abstract Solid-state detectors with a low energy threshold have several applications, including searches of non-relativistic halo dark-matter particles with sub-GeV masses. When searching for relativistic, beyond-the-Standard-Model particles with enhanced cross sections for small energy transfers, a small detector with a low energy threshold may have better sensitivity than a larger detector with a higher energy threshold. In this paper, we calculate the low-energy ionization spectrum from high-velocity particles scattering in a dielectric material. We consider the full material response including the excitation of bulk plasmons. We generalize the energy-loss function to relativistic kinematics, and benchmark existing tools used for halo dark-matter scattering against electron energy-loss spectroscopy data. Compared to calculations commonly used in the literature, such as the Photo-Absorption-Ionization model or the free-electron model, including collective effects shifts the recoil ionization spectrum towards higher energies, typically peaking around 4–6 electron-hole pairs. We apply our results to the three benchmark examples: millicharged particles produced in a beam, neutrinos with a magnetic dipole moment produced in a reactor, and upscattered dark-matter particles. Our results show that the proper inclusion of collective effects typically enhances a detector’s sensitivity to these particles, since detector backgrounds, such as dark counts, peak at lower energies.

Physics