Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scanning Electron Microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Atmospheric pressure scanning transmission electron microscopy

Scanning transmission electron microscope (STEM) images of gold nanoparticles (2.1 nm average diameter) at atmospheric pressure have been recorded through a 0.36 mm thick mixture of CO, O2 and He. This was accomplished using a reaction cell consisting of two electron-transparent silicon nitride membranes mounted on a specially designed specimen rod. Gas flow occurred through plastic tubing from the outside of the microscope to the specimen region and back. Gold nanoparticles of a full width half maximum diameter of 1.0 nm were visible above the background noise and the achieved resolution was 0.5 nm in accordance with calculations of the beam broadening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Microscopy Transfer System to Protect Atmosphere‐Sensitive Materials for Scanning Electron Microscopy Characterization

Atmosphere- and/or moisture-sensitive materials can be challenging to characterize using electron microscopy techniques due to sample preparation workflows that generally require exposure to ambient conditions. Here, we describe a novel preparation method that uses aluminum foil in combination with a commercial cryo-EM transfer system to circumvent undesired exposure to the atmosphere. First, hygroscopic MgCl 2 was used as a model material, and prepared samples (both protected and unprotected) were placed in a controlled-humidity environment (> 80% relative humidity) for various exposure lengths (circa seconds to hours). Following this, the effectiveness of the sample preparation method was determined by comparing qualitative photos and quantitative X-ray diffraction patterns between the two sample subsets. The combined results of these experiments suggest that the outlined preparation method effectively protects MgCl 2 from atmospheric contamination compared to MgCl 2 samples that had no protective measures taken. Finally, the preparation method was utilized to protect a highly hygroscopic crystalline BaO thin film for characterization via scanning electron microscopy, thereby demonstrating a functional application of the outlined preparation technique and an additional use for the commercial cryo-EM transfer system beyond its intended application.

atmosphere-sensitive materials↗

Noise characteristics of the gas ionization cascade used in low vacuum scanning electron microscopy

The noise characteristics of gas cascade amplified electron signals in low vacuum scanning electron microscopy (LVSEM) are described and analyzed. We derive expressions for each component contributing to the total noise culminating in a predictive, quantitative model that can be used for optimization of LVSEM operating parameters. Signal and noise behavior is characterized experimentally and used to validate the model. Under most operating conditions, the noise is dominated by the excess noise generated in the gas amplification cascade. At high gains, the excess noise increases proportionally with gain such that the signal-to-noise ratio is constant. The effects of several instrument operating parameters, including working distance, gas pressure, beam current, and detector bias, are condensed and presented in the form of a master curve.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Systematic features of defocused images in scanning electron microscopy and nanoscale size measurements

The problems of nanoscale size measurements were considered. The results of full-scale and model experiments with images of backscattered electron-scanning electron microscopy show that all intensity profiles appearing during defocusings intersect at points corresponding to object edges. A physical explanation to the observed effect was proposed. The model validity was confirmed for a rectangular bump. Presumably, the effect makes it possible to avoid the electron micrograph's simulation when comparing images of a measured object with a measure image.

36 MATERIALS SCIENCE↗

Nanodot formation induced by femtosecond laser irradiation

The femtosecond laser generation of ZnSe nanoscale features on ZnSe surfaces was studied. Irradiation with multiple exposures produces 10–100 nm agglomerations of nanocrystalline ZnSe while retaining the original single crystal structure of the underlying material. The structure of these nanodots was verified using a combination of scanning transmission electron microscopy, scanning electron microscopy, and atomic force microscopy. The nanodots continue to grow hours after irradiation through a combination of bulk and surface diffusion. We suggest that in nanodot formation the result of ultrafast laser induced point defect formation is more than an order of magnitude below the ZnSe ultrafast melt threshold fluence. This unique mechanism of point defect injection will be discussed.

36 MATERIALS SCIENCE↗

Testing fast reactor fuels in a thermal reactor: Comparison of transmutation metallic fuel alloys behavior by scanning electron microscopy

To optimize nuclear waste repository performance, the destruction of minor actinide elements, particularly Np and Am, in a neutron fast spectrum reactor is possible by incorporating these elements into nuclear fuel. Evaluating the performance of minor actinide containing fuel is of paramount importance to enabling this technology. However, such a task is challenging without an available domestic fast spectrum test reactor. A comparison of fuel performance tested in an available domestic thermal reactor at the Idaho National Laboratory, the Advanced Test Reactor, and in a fast spectrum reactor in France (Phénix) is presented here in this study. This study evaluates the capability of using a cadmium shrouded test position to mimic the power profile along the fuel radius present in fast spectrum reactors so that thermally driven phenomenon (e.g., constituent redistribution) can be evaluated in a thermal reactor and determined to be prototypical of a fast reactor. Thus, optical microscopy and scanning electron microscopy has been performed on irradiated 35U-29Pu-4Am-2Np-30Zr fuel samples (where the number preceding the element is the weight percent concentration) from the two mentioned reactors that present similar irradiation temperatures and power conditions. The results indicate that fuel performance phenomena are reproducible in the two irradiation conditions. The redistribution of Zr occurred in the same manner for the two samples. Similar partitioning of U-Pu-Zr phases was observed, and the behavior of Am was similar in the analyzed specimens. Finally, the overall microstructure evolution seems not to be affected by minor actinides addition compared to expected behavior of conventional U-19Pu-10Zr ternary metal fuels for both specimens. Slight differences in fuel cladding chemical interaction were, however, observed. This difference is likely driven by difference in cladding composition rather than irradiation conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A high contrast method of unstained biological samples under a thin carbon film by scanning electron microscopy

The contrast of biological samples in scanning electron microscopy (SEM) is very weak. To examine a biological specimen by SEM, many steps and/or special equipment are required to prepare the sample. Here, we describe a method using an unstained biological sample under a 40 nm carbon film to give a high contrast image, where the image is detected by the secondary electron (SE) signal at a low accelerating voltage of 1.5 kV. Under these conditions, it is hard to detect a direct signal from a biological specimen. The high contrast image is created by the SEs from the lower surface of the thin carbon film. Therefore, the damage to the sample from the electron beam is very low. Our method can be utilized to observe various biological samples of bacteria, viruses, and protein complexes.

60 APPLIED LIFE SCIENCES↗

Variable Pressure - Scanning Electron Microscopy (VP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Miniature Variable Pressure - Scanning Electron Microscopy (MVP-SEM)

Variable Pressure (or Environmental) Scanning Electron Microscopy (VP-SEM) combined with Energy Dispersive X-ray Spectroscopy (EDS) is one of the most powerful methods for characterizing the sub-micron topography and chemical composition of uncoated samples. Terrestrially, VP-SEM is extensively used to non-destructively study geologic and manufactured materials with high spatial resolution (tens of nanometers) and large depth-of-field. An SEM offers a geologist a first survey of microscopic mineral phases via secondary electron imaging (SEI), which provides a topographic look at a sample, as well as backscattered electron (BEI) imaging, which contrasts the phases present based on their geochemistry (atomic number). A VP-SEM utilizes a gas in the sample chamber as a charge dissipation and signal amplification method, allowing analysis of a sample without preparation in the form of a conductive coating. A miniaturized VP-SEM operating in-situ on a lander or rover would be able to use the CO2-rich Martian atmosphere (e.g., Nier et al., 1976; Williams 2016) as an imaging medium for this purpose. Adaptation of a VP-SEM for in-situ Mars surface studies will provide a new imaging capability (via SEI) that is at least an order of magnitude higher resolution than the Mars Hand Lens Imager (MAHLI) on the Mars Science Laboratory (Williams et al., 2015), and equal to or better than the achieved resolution of the Atomic Force Microscope on the Phoenix Mars lander (Pike et al., 2011). In addition, the MVP-SEM is capable of BSI and simultaneous chemical analysis of the imaged region. In this sense, the MVP-SEM can be regarded as an instrument suite that will provide a new set of information not achievable by any other instrument. The Miniaturized Variable Pressure Scanning Electron Microscope (MVP-SEM) was designed, built, and benchtop tested by a team at NASA’s Marshall Space Flight Center and Jet Propulsion Laboratory (JPL), Jacobs Space Exploration Group, Applied Physics Technologies, Inc. (AP-Tech), and Creare LLC, working with a team of technical and science collaborators. Benchtop testing was successful, proving concept feasibility. To date, the MVP-SEM has achieved an imaging resolution of <100 nm in the lab, and with continued optimization, even better performance (~50 nm resolution) is possible. Use in-situ on the lunar or other planetary surfaces would require some redesign to optimize instrument performance, but such an instrument would be equally useful.

Variable Pressure Scanning Electron Microscopy↗

Magnetic nanofilms of nickel prepared at the liquid-liquid interface

Highlights: {yields} Formation of nickel thinfims at the organic-aqueous interface at room temperature. {yields} Thickness of nanofilm is {approx}20 nm. {yields} Ni nanofilms exhibit superparamagnetic behavior. {yields} Thicker Ni films are obtained at a higher temperature (60 {sup o}C). -- Abstract: Thin films of metallic nickel with a thickness of the order of 20 nm have been prepared at the organic-aqueous interface at room temperature by the reaction of nickel cupferronate [Ni(C{sub 6}H{sub 5}N{sub 2}O{sub 2}){sub 2}] in toluene medium and sodium borohydride (NaBH{sub 4}) in aqueous medium. The films were characterized with transmission electron microscopy, scanning electron microscopy and atomic force microscopy. Thicker Ni films could be prepared by carrying out the reaction at the interface at 60 {sup o}C. The Ni nanofilms exhibit superparamagnetic behavior.

36 MATERIALS SCIENCE↗

Highly ordered Ti-SBA-15: Efficient H{sub 2} adsorbent and photocatalyst for eco-toxic dye degradation

Highly ordered 2D-hexagonal mesoporous titanium silicate Ti-SBA-15 materials (space group p6mm) have been synthesized hydrothermally in acidic medium employing amphiphilic tri-block copolymer, Pluronic F127 as structure directing agent. Samples are characterized by powder X-ray diffraction, transmission electron microscopy, scanning electron microscopy, FT IR spectroscopy, UV-visible diffuse reflectance measurements, N{sub 2} adsorption/desorption and TG-DTA analysis. XRD and TEM results suggested the presence of highly ordered mesophase with hexagonal pore arrangements. BET surface area for Ti-SBA-15 (924 m{sup 2} g{sup -1}) is considerably higher than the pure silica SBA-15 (611 m{sup 2} g{sup -1}) prepared following the same synthetic route. UV-visible and FT-IR studies suggested the incorporation of mostly tetrahedral titanium (IV) species, along with some six-coordinated sites in the silicate network. This material shows very good H{sub 2} adsorption capacity at higher pressure and excellent catalytic activity in the photocatalytic degradation of ecologically abundant dye methylene blue. - Graphical abstract: Highly ordered 2D-hexagonal mesoporous Ti-SBA-15 materials are synthesized hydrothermally, which show high H{sub 2} adsorption capacity and excellent activity in the photocatalytic degradation of ecologically abundant dye methylene blue.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Microstructural evolution of P92 ferritic/martensitic steel under Ar{sup +} ion irradiation at elevated temperature

Irradiation damage in P92 ferritic/martensitic steel irradiated by Ar{sup +} ion beams to 7 and 12 dpa at elevated temperatures of 290 Degree-Sign C, 390 Degree-Sign C and 550 Degree-Sign C has been investigated by transmission electron microscopy, scanning electron microscopy and atomic force microscopy. The precipitate periphery (the matrix/carbide interface) was amorphized only at 290 Degree-Sign C, while higher irradiation temperature could prevent the amorphization. The formation of the small re-precipitates occurred at 290 Degree-Sign C after irradiation to 12 dpa. With the increase of irradiation temperature and dose, the phenomenon of re-precipitation became more severe. The voids induced by irradiation were observed after irradiation to 7 dpa at 550 Degree-Sign C, showing that high irradiation temperature ({>=} 550 Degree-Sign C) was a crucial factor which promoted the irradiation swelling. Energy dispersive X-ray analysis revealed that segregation of Cr and W in the voids occurred under irradiation, which may influence mechanical properties of P92 F/M steel. - Graphical Abstract: High density of small voids, about 2.5 nm in diameter, was observed after irradiation to 12 dpa at 550 Degree-Sign C, which was shown in panel a (TEM micrograph). As shown in panel b (SEM image), a large number of nanometer-sized hillocks were formed in the surface irradiated at 550 Degree-Sign C, and the mean size was {approx} 30 nm. The formation of the nanometer-sized hillocks might be due to the voids that appeared as shown in TEM images (panel a). High irradiation temperature ({>=} 550 Degree-Sign C) was a crucial factor for the formation of void swelling. Highlights: Black-Right-Pointing-Pointer Small carbides re-precipitated in P92 matrix irradiated to 12 dpa at 290 Degree-Sign C. Black-Right-Pointing-Pointer High density of voids was observed at 550 Degree-Sign C. Black-Right-Pointing-Pointer Segregation of Cr and W in voids occurred under irradiation.

36 MATERIALS SCIENCE↗

A novel synthesis of micrometer silica hollow sphere

Silica microcapsules (hollow spheres) were synthesized successfully by a novel CTAB-stabilized water/oil emulsion system mediated hydrothermal method. The addition of urea to a solution of aqueous phase was an essential step of the simple synthetic procedure of silica hollow spheres, which leads to the formation of silica hollow spheres with smooth shell during hydrothermal process. The intact hollow spheres were obtained by washing the as-synthesized solid products with distilled water to remove the organic components. A large amount of silanol groups were retained in the hollow spheres by this facile route without calcination. The morphologies and optical properties of the product were characterized by transmission electron microscopy, scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy. Furthermore, on the basis of a series of SEM observations, phenomenological elucidation of a mechanism for the growth of the silica hollow spheres has been presented.

36 MATERIALS SCIENCE↗

Synthesis of oxidation resistant lead nanoparticle films by modified pulsed laser ablation

Thin layers of lead nanoparticles have been produced by a modified pulsed laser ablation (PLA) process in which smaller nanoparticles were swept out of the ablation chamber by a stream of flowing Ar. Large ({mu}m-sized) particles, which are usually deposited during the standard PLA process, were successfully eliminated from the deposit. The nanoparticles deposited on room temperature substrates were well distributed, and the most probable particle diameter was in the order of 30 nm. Since lead is highly reactive, the nanoparticles formed in Ar were quickly oxidized upon exposure to air. A small partial pressure of H{sub 2}S gas was subsequently added to the effluent, downstream from the ablation chamber, and this resulted in the formation of nanoparticle deposits that were surprisingly oxidation resistant. The properties of the nanoparticle films (as determined by transmission electron microscopy, scanning electron microscopy, x-ray diffraction, x-ray photoelectron spectroscopy, and conductivity measurements) are reported, and the mechanism of the oxidation retardation process is discussed.

36 MATERIALS SCIENCE↗

Structural properties and growth mechanism of Cd{sub 3}As{sub 2} nanowires

Cadmium arsenide (Cd{sub 3}As{sub 2}) is a material well-known for its very high room-temperature carrier mobility. Recently, it has also been shown to be a three-dimensional Dirac semimetal—the three-dimensional analogue of graphene. Here, we present a detailed structural study of the self-catalyzed growth of Cd{sub 3}As{sub 2} nanowires. The crystal structure is confirmed using X-ray diffraction and transmission electron microscopy. Scanning electron microscopy and energy-dispersive X-ray spectroscopy are used to gain insight into the vapor-solid growth mechanism. The role of group II and V elements is reversed in contrast to III-V and other II-V systems, and the tips are found to be As-rich.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Combined electron microscopy and spectroscopy characterization of as-received, acid purified, and oxidized HiPCO single-wall carbon nanotubes

Single-wall carbon nanotubes (SWCNTs) are very important materials due to their combination of unique structure, dimension, strength, chemical stability, and electronic properties. Nevertheless, SWCNTs from commercial sources usually contain several impurities, which are usually removed by a purification process that includes reflux in acids and strong oxidation. This strong chemical procedure may alter the nanotube properties and it is thus important to control the extent of functionalization and oxidation during the purification procedure. In this report, we provide a comprehensive study of the structure and physical composition of SWCNTs during each step of the purification process. Techniques such as Raman spectroscopy, transmission electron microscopy, scanning electron microscopy, thermogravimetric analysis, X-ray photoelectron spectroscopy and Infrared spectroscopy were used to track the SWCNTs structure, in terms of length and diameter distribution, and surface chemical modifications during each purification stage.

36 MATERIALS SCIENCE↗