Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Mobile Air Sampler

Vehicle-mounted sampler gathers specimens along highways and in tunnels. In contrast to fixed air-collection installations, mobile sampler requires no official approval for use on highways.

Tucker, C. E.↗

Solid-Sorbent Air Sampler

Portable unit takes eight 24-hour samples. Volatile organic compounds in air collected for analysis by portable, self-contained sampling apparatus. Sampled air drawn through sorbent material, commercial porous polymer of 2, 3-diphenyl-p-phenylene oxide. High-boiling-point organic compounds adsorbed onto polymer, while low-boiling-point organics pass through and returned to atmosphere. Sampler includes eight sample tubes filled with polymeric sorbent. Organic compounds in atmosphere absorbed when air pumped through sorbent. Designed for checking air in spacecraft, sampler adaptable to other applications as leak detection, gas-mixture analysis, and ambient-air monitoring.

Galen, T. J.↗

Timing Sampler For Delay Measurements

Integrated circuit called timing sampler used to measure delays in complementary metal oxide/silicon logic gates. Circuit chip contains chains of inverters and metal traces having minimum parasitic delays (delay chains), circuits to compare pulse timings, and output multiplexer. Timing sampler enables delay measurements for both positive and negative logic-level transitions by use of variety of circuit geometries representing tentative practical designs.

Blaes, Brent R.↗

Evaluation of a pneumatic Martian soil sampler concept

The pneumatic soil sampler concept was successfully demonstrated by penetrating a Martian simulant soil to a depth of 2 meters. Working gas pressure, composition, and pulsing were evaluated with the objective of minimizing gas usage. Also, the probe penetration force was investigated with the objective of minimizing probe weight. Gas and probe penetration force, while not yet optimized, are within the range which make the soil sampler concept feasible. While the tests described in this report did not answer all the questions and address all the variables associated with pneumatic soil sampling, valuable data experience and knowledge were gained which can be used to further develop the concept.

Schaefer, John L.↗

A High Volume Stack Sampler

The stack sampler described in this paper has been developed to overcome the difficulties of particulate sampling with presently available equipment. Its use on emissions from hog fuel fired boilers, back-fired incinerators, wigwam burners, asphalt plants, and seed cleaning cyclones is reported. The results indicate that the sampler is rapid and reliable in its use. It is relatively simple and inexpensive to operate. For most sources it should be considered over the more complicated and expensive sampling trains being used and specified.

Boubel, Richard W.↗

Touch and Go Surface Sampler (TGSS)

The Touch and Go Surface Sampler (TGSS) is a new class of planetary and small body sample acquisition tool that can be used for the surface exploration of Europa, Titan and comets. TGSS in its basic configuration consists of a high speed sampling head attached to the end of a flexible shaft. The sampling head consists of counter rotating cutters that rotates at speeds of 3000 to 15000 RPM. The attractive feature of this if touch and go type sampler is that there are no requirements for a lander type spacecraft. Additional information is contained in the original extended abstract.

Gorevan, S. P.↗

Deep-Sea Hydrothermal-Vent Sampler

An apparatus is being developed for sampling water for signs of microbial life in an ocean hydrothermal vent at a depth of as much as 6.5 km. Heretofore, evidence of microbial life in deep-sea hydrothermal vents has been elusive and difficult to validate. Because of the extreme conditions in these environments (high pressures and temperatures often in excess of 300 C), deep-sea hydrothermal- vent samplers must be robust. Because of the presumed low density of biomass of these environments, samplers must be capable of collecting water samples of significant volume. It is also essential to prevent contamination of samples by microbes entrained from surrounding waters. Prior to the development of the present apparatus, no sampling device was capable of satisfying these requirements. The apparatus (see figure) includes an intake equipped with a temperature probe, plus several other temperature probes located away from the intake. The readings from the temperature probes are utilized in conjunction with readings from flowmeters to determine the position of the intake relative to the hydrothermal plume and, thereby, to position the intake to sample directly from the plume. Because it is necessary to collect large samples of water in order to obtain sufficient microbial biomass but it is not practical to retain all the water from the samples, four filter arrays are used to concentrate the microbial biomass (which is assumed to consist of particles larger than 0.2 m) into smaller volumes. The apparatus can collect multiple samples per dive and is designed to process a total volume of 10 L of vent fluid, of which most passes through the filters, leaving a total possibly-microbe-containing sample volume of 200 mL remaining in filters. A rigid titanium nose at the intake is used for cooling the sample water before it enters a flexible inlet hose connected to a pump. As the water passes through the titanium nose, it must be cooled to a temperature that is above a mineral-precipitation temperature of 100 C but below the upper working temperature (230 C) of switching valves and tubes in the apparatus. The sample water then passes into a manifold tube, from whence the switching valves can direct the water through either a bypass tube or any one of the filter arrays, without contamination from a previous sample. Each filter array consists of series of filters having pore sizes decreasing in the direction of flow: 90-, 60-, 15-, and 7-micron prefilters and a large-surface-area 0.2-micron collection filter. All the filter taps are located between the intake and the bypass tube so that each time the bypass tube is used, the entire manifold tube is flushed as well.

Behar, Alberto E.↗

Three-Wheel Brush-Wheel Sampler

A new sampler is similar to a common snow blower, but is robust and effective in sample collection. The brush wheels are arranged in a triangle shape, each driven by a brushless DC motor and planetary gearhead embedded in the wheel shaft. Its speed can be varied from 800 - 2,000 rpm, depending on the surface regolith resistance. The sample-collecting flow path, and internal features, are designed based on flow dynamics, and the sample-collecting rates have consistently exceeded the requirement under various conditions that span the range of expected surface properties. The brush-wheel sampler (BWS) is designed so that the flow channel is the main body of the apparatus, and links the brush-wheel assembly to the sample canister. The combination of the three brush wheels, the sample flow path, and the canister location make sample collection, storage, and transfer an easier task.

Duckworth, Geoffrey A.↗

Biblade Sampler

A BiBlade sampler may include a first blade and a second blade in a retracted position. The BiBlade sampler may also include a gripper, which is driven by an actuator. The gripper may include a plurality of fingers to force the first blade and the second blade to remain in a retracted position. When the fingers are unhooked, the first blade and the second blade penetrate a surface of an object.

Backes, Paul G.↗

Microbial Air Sampler Payload - Astrobee

The following package 2020-09-28 Microbial Air Sampler folders consist of a prototype design of a microbial air sample payload to fit in the bays of Astrobee free-flyer. There are several CAD designs prototypes and documentation about the concept and the current air sampler device.

Jose Cortez↗

Air sampler collects and protects minute particles

Air ejector impactor sampler collects and protects samples of particles greater than 0.1 micron in diameter. In operation, it causes impaction of particle-laden air onto several collection surfaces within a collection cylinder. When not operating, the collector cylinder is maintained in a retracted state within a protective envelope.

Wood, R. C.↗

Soil mechanics surface sampler - Lunar surface test and results

After the success of Surveyor I in meeting the objectives of the engineering flight series, selection from among candidate experiments led to the inclusion of the Soil Mechanics Surface Sampler (SMSS) on the payload. Though originally planned for later Surveyors, the SMSS design was modified to fit the reduced telemetry and commanding capability of the earlier spacecraft. These modifications included removal of the strain-, acceleration-, and position-measuring systems originally planned, and incorporation of a means for measuring current drawn by the motors during operation. A description of the modified device, its performance on Surveyor III, and some conclusions regarding the lunar surface material drawn from the experiment are presented.

Ground test↗