Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Residual Gas Analyzer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER

Understanding the Quadrupole Mass Filter and Testing a High-Resolution QMS RGA for ITER

A common type of residual gas analyzer is the quadrupole mass spectrometer. One of the main components within this instrument is a mass filter known as the quadrupole. It is responsible for the selective throughput of the ionized gas particles - by ascending mass number - prior to ion impacts on the analyzer (or detector) surface from which the ion current signal is generated for processing. However, the quadrupole is not fully described in relation to the electric field characteristics and the function as an ion mass separator. This paper describes the basic origins of the electrical design, the intricate assembly criteria, and performance of the quadrupole within the spectrometer. A specialized quadrupole mass spectrometer is part of a configuration for a diagnostic gas analyzer system planned for ITER, a fusion research machine. It has a verified capability, essential as a diagnostic criterion for this reactor project, to successfully deconvolute the mass signals of Helium-4 and deuterium (reactor fuel exhaust gases, separated by only 0.026 atomic mass units), down to a relative three-percent concentration of the former gas. The associated preliminary testing, performed at the Oak Ridge National Laboratory, is also addressed. Finally, one of the key parameters used to express gas concentration, the relative sensitivity factor, will be explained, including an evaluation of dependency on other variables.

Marcus, Chris [ORNL] (ORCID:0000000190139636)

Analysis of Off-Gas Streams from Small- and Large-Scale Sparging Salt Vessels using Laser-Induced Breakdown Spectroscopy

Laser-induced breakdown spectroscopy (LIBS) is being developed as an analytical monitoring tool for molten salt reactor (MSR) systems. A mobile LIBS platform was configured on a small-scale salt vessel (~100 g of salt) and then transported 0.6 km to successfully monitor an engineering-scale pumped salt loop (~100 kg of salt). Several studies on monitoring salt aerosols, hydrogen isotopes, and noble gases were performed on the small-scale system. All these studies were then implemented for monitoring various tests on the engineering-scale loop. Aerosolized salts from both the storage tank and pump bowl were monitored using LIBS to assess bulk salt analyte ratios (Mg, Na, K) and evaluate impurities (H, O, Ca). In addition to monitoring salt aerosols, LIBS was used in tandem with a residual gas analyzer (RGA) and a Raman spectroscopy system to detect hydrogen isotopes as they were sparged through and subsequently depleted from the loop storage tank. Lastly, a similar test with noble gases (100 ppm Kr, 1000 ppm Xe) was performed, in which LIBS demonstrated a faster response than the RGA used in-line. The tests and results are summarized in this report with detailed publications to follow. Key takeaways are listed in the conclusion of the report.

22 GENERAL STUDIES OF NUCLEAR REACTORS

A Comparison of Quartz Crystal Microbalance Measurements with Mass Spectrometer Determinations

An experimental program was undertaken in which mass accretion rates, as determined by a liquid nitrogen cooled quartz crystal microbalance, were compared with the mass flux rates, as determined by both a cycloidal type and a quadrupole type residual gas analyzer for five simple materials. The data indicate a high degree of correlation between these instruments insofar as the shape of the curves. There are large variations however among the absolute values.

Kruger, R.

A modified quadrupole mass spectrometer with custom RF link rods driver for remote operation

A commercial quadrupole residual gas analyzer system has been upgraded for operation at extended cable lengths. Operation inside a vacuum chamber for the standard quadrupole nude head is limited to approximately 2 m from its externally located rf/dc generator because of the detuning of the rf oscillator circuits by the coaxial cable reactance. The advance of long distance remote operation inside a vacuum chamber for distances of 45 and 60 m was made possible without altering the quadrupole's rf/dc generator circuit by employing an rf link to drive the quadrupole rods. Applications of the system have been accomplished for in situ space simulation thermal/vacuum testing of sophisticated payloads.

Tashbar, P. W.

A remote operation quadrupole mass spectrometer using a custom radio-frequency link approach

A commercial quadrupole mass spectrometer (residual gas analyzer, RGA) system has been modified to operate at large separations of its electronics console and sensing head. The methods implemented have made practical applications, as well as operation, of such a system possible for the first time. This advance was stimulated by a need for placing sensors at remote (45 or 60 m) chamber locations for space simulation testing of orbital flight spacecraft. Emphasis is placed on instrument functional requirements and describing the hardware changes and adjustment techniques necessary to assure operation at the extended cable lengths.

Tashbar, P. W.

Integrated material-surface analyzer

These 10 surface-analysis tests can be run without breaking vacuum: secondary-ion mass spectroscopy, ion-scattering spectroscopy, electron-stimulated desorption, residual-gas analysis, auger electron spectroscopy, x-ray photoelectron spectroscopy, ultraviolet photoelectron spectroscopy, characteristic-electron energy-loss spectroscopy, scanning electron microscope, scanning low-energy electron probe. Quadruple mass spectrometer, used in first 4 tests, serves as electron transfer lens in last 6 tests.

Grunthaner, F. J.

Leak rate measurements for satellite subsystems and residual gas analysis during space environment tests

The measuring and evaluation procedure for the determination of leak rates of satellite subsystems with a quadrupole mass spectrometer, and the results of the residual gas analysis are described. The method selected for leak rate determination was placing the system into a vacuum chamber and furnishing the chamber with a mass spectrometer and calibrated leaks. The residual gas of a thermal vacuum test facility, in which the thermal balance test radiation input was simulated by a heated canister, was analyzed with the mass spectrometer in the atomic mass unit range up to 300 amu. In addition to the measurements during the space environment tests, mass spectrometric studies were performed with samples of spacecraft materials. The studies were carried out during tests for the projects HELIOS, AEROS B and SYMPHONIE.

Nuss, H. E.

Isotopic anomalies of noble gases in meteorites and their origins. VI Presolar components in the Murchison C2 chondrite

Rare gases were analyzed by stepped heating in five fractions of a chemically resistant residue from Murchison that had been separated according to grain size and resistance to HClO4. Nine gas components were recognized, of which three appear to be presolar: (1) Ne-E(H) released at 1000-1600 C and located in spinel; (2) Ne-E(L) released at less than 800 C and apparently located in a carbonaceous phase of grain size up to 10 microns; and (3) s-process Xe and Kr released at 1200-1600 C and located in a poorly characterized, possibly carbonaceous phase, distinct from the host phase of Ne-E(L).

Alaerts, L.

Liquid rocket performance computer model with distributed energy release

Development of a computer program for analyzing the effects of bipropellant spray combustion processes on liquid rocket performance is described and discussed. The distributed energy release (DER) computer program was designed to become part of the JANNAF liquid rocket performance evaluation methodology and to account for performance losses associated with the propellant combustion processes, e.g., incomplete spray gasification, imperfect mixing between sprays and their reacting vapors, residual mixture ratio striations in the flow, and two-phase flow effects. The DER computer program begins by initializing the combustion field at the injection end of a conventional liquid rocket engine, based on injector and chamber design detail, and on propellant and combustion gas properties. It analyzes bipropellant combustion, proceeding stepwise down the chamber from those initial conditions through the nozzle throat.

Combs, L. P.

A neon-E rich phase in Orgueil - Results of stepwise heating experiments

A Ne-E rich phase was separated from the Orgeuil carbonaceous chondrite. He and Ne were analyzed in this phase and in an Orgueil residual bulk silicate sample using the stepwise heating technique. Ne-E was found to be released from the Ne-E rich phase at temperatures as low as 500 C; however, gas richest in Ne-E is observed at the highest temperatures (1230 C). The following limits for the isotopic composition of Ne-E were obtained: Ne-20/Ne-22 less than 1.52; Ne-21/Ne-22 less than 0.0244.

Eberhardt, P.

Determination of the gram-positive bacterial content of soils and sediments by analysis of teichoic acid components

Many gram-positive bacteria form substituted polymers of glycerol and ribitol phosphate esters known as teichoic acids. Utilizing the relative specificity of cold concentrated hydrofluoric acid in the hydrolysis of polyphosphate esters it proved possible to quantitatively assay the teichoic acid-derived glycerol and ribitol from gram-positive bacteria added to various soils and sediments. The lipids are first removed from the soils or sediments with a one phase chloroform-methanol extraction and the lipid extracted residue is hydrolyzed with cold concentrated hydrofluoric acid. To achieve maximum recovery of the teichoic acid ribitol, a second acid hydrolysis of the aqueous extract is required. The glycerol and ribitol are then acetylated after neutralization and analyzed by capillary gas-liquid chromatography. This technique together with measures of the total phospholipid, the phospholipid fatty acid, the muramic acid and the hydroxy fatty acids of the lipopolysaccharide lipid A of the gram-negative bacteria makes it possible to describe the community structure environmental samples. The proportion of gram-positive bacteria measured as the teichoic acid glycerol and ribitol is higher in soils than in sediments and increases with depth in both.

Ribitol/analogs & derivatives