Automating a residual gas analyzer

A residual gas analyzer (RGA), a device for measuring the amounts and species of various gases present in a vacuum system is discussed. In a recent update of the RGA, it was shown that the use of microprocessors could revolutionize data acquisition and data reduction. This revolution is exemplified by the Inficon 1Q200 RGA which was selected to meet the needs of this update. The Inficon RGA and the Zilog microcomputer were interfaced in order the receive and format the digital data from the RGA. This automated approach is discussed in detail.

Petrie, W. F.

Characteristics and performance of several mass spectrometer residual gas analyzers

The operation and properties of various mass-spectrometer residual gas analyzers for use in vacuum measurements were analyzed in terms of efficiencies of ion extraction, ion separation and transmission, and ion collection. Types of instruments studied were magnetic sector, omegatron, quadrupole, and monopole. Experimental results presented include absolute sensitivity to argon, relative sensitivity to 10 gases, and cracking patterns for these gases. It is shown that the properties are strongly dependent on instrument range, resolution, and the particular voltages, currents, or field intensities used to control the instrument.

Hultzman, W. W.

Design, fabrication, assembly and delivery of a laboratory prototype of a residual gas analyzer

The design, development, and testing of a wide mass range residual gas analyzer which will be one component of an integrated real time contamination monitor system are described. The instrument has been developed and tested to the laboratory prototype phase, demonstrating the performance that can be expected from a flight instrument of similar design. The instrument's analyzer is of the quadrupole type and a cold cathode ion source is employed as the ionizer. The associated electronics supply all necessary operating and mass sweep voltages for the ionizer, analyzer and electron multiplier ion detector. The instrument features a very fast linear electrometer with automatic range changing. The full mass range of 2 to 300 amu is automatically and repetitively scanned every sixty seconds and suitable telemetry outputs are provided for intensity and mass identification as well as a digital identification of the electrometer range.

Kreisman, W. S.

Program for computing partial pressures from residual gas analyzer data

A computer program for determining the partial pressures of various gases from residual-gas-analyzer data is given. The analysis of the ion currents of 18 m/e spectrometer peaks allows the determination of 12 gases simultaneously. Comparison is made to ion-gage readings along with certain other control information. The output data are presented in both tabular and graphical form.

Easton, D. S.

An investigation of accelerating mode and decelerating mode constant-momentum mass spectrometry and their application to a residual gas analyzer

A theoretical analysis of constant momentum mass spectrometry was made. A maximum resolving power for the decelerating mode constant momentum mass spectrometer was shown theoretically to exist for a beam of ions of known energy. A vacuum system and an electron beam ionization source was constructed. Supporting electronics for a residual gas analyzer were built. Experimental investigations of various types of accelerating and decelerating impulsive modes of a constant momentum mass spectrometer as applied to a residual gas analyzer were made. The data indicate that the resolving power for the decelerating mode is comparable to that of the accelerating mode.

Ng, Y. S.

Residual Gas Analyzer Calibration

A technique which employs known gas mixtures to calibrate the residual gas analyzer (RGA) is described. The mass spectra from the RGA are recorded for each gas mixture. This mass spectra data and the mixture composition data each form a matrix. From the two matrices the calibration matrix may be computed. The matrix mathematics requires the number of calibration gas mixtures be equal to or greater than the number of gases included in the calibration. This technique was evaluated using a mathematical model of an RGA to generate the mass spectra. This model included shot noise errors in the mass spectra. Errors in the gas concentrations were also included in the valuation. The effects of these errors was studied by varying their magnitudes and comparing the resulting calibrations. Several methods of evaluating an actual calibration are presented. The effects of the number of gases in then, the composition of the calibration mixture, and the number of mixtures used are discussed.

R H Lilienkamp

Characteristics and performance study of mass spectrometer residual gas analyzers

Types of instruments studied were magnetic sector, omegatron, quadrupole, and monopole. Experimental results obtained included absolute sensitivity to argon, relative sensitivity to ten gases (hydrogen, helium, neon, nitrogen, carbon monoxide, oxygen, argon, carbon dioxide, krypton, and xenon), and cracking patterns for these gases.

Hultzman, W. W.

Analysis of low resolution mass spectra

Computer program determines gas constituents from measurements of mass/peak-height spectrum from residual gas analyzer. Applications of program include residual gas analysis for work in space environmental simulators, space environment contamination, and air pollution monitoring.

Babst, R. W.

INL Intern Poster Session

Characterization of off-gas constituents from nuclear fuel reprocessing can be measured using a residual gas analyzer. Characterization of this off-gas is important in a closed fuel cycle, where gasses such as Nox, Kr, I, and C-14 need to be removed from reprocessing plants to meet regulatory requirements. Both Kr and Xe have low chemical reactivity, making capture and separation difficult. Solid sorbents can be used to capture these gases as an alternative to cryogenic distillation, which is energy intensive and hazardous. AgZ-PAN and HZ-PAN are two solid sorbents that have demonstrated selective capture of Xe and Kr. A residual gas analyzer can be used to obtain breakthrough curves that demonstrate how well this adsorption and separation occur. The breakthrough curve is dependent on packing density, column size, and flow rate. Data obtained from the RGA was verified with a gas chromatographer.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS

Feasibility of fusion plasma burn control via real-time, sub-divertor neutral gas isotopic and compositional analysis

The ability to provide fusion burn control without requiring physical access through the first wall and fuel breeding blankets, would be vital for any future, magnetically confined fusion power reactor. A multi-sensor, fusion fuel cycle exhaust, neutral gas analysis system on JET, capable of delivering real time data, and accessing only the sub-divertor region, provides an excellent example of such capability. Optimized for and operated during the deuterium–tritium experimental campaigns 2 and 3 (DTE2, DTE3), it is proving valuable for planning to explore fusion reactor burn control in ITER with a comparable diagnostic system called the Diagnostic Residual Gas Analyzer (DRGA). This paper aims to show feasibility of developing model-based controllers for ITER and next generation, reactor-relevant devices, by building both on the empirical experience in JET-DTE2, and on the already emerging experience on developing such models specifically for ITER. The paper begins with a specific use-case from JET-DTE2, pertaining to the observed sensitivity of the fusion neutron yield on the concentration of isotopic helium-3 ( 3 He), with data from one of the high-performance DT shots exhibited with emphasis on the 3 He measurement via the sub-divertor. Then, a first model is developed and then explored with simulations that aim to discover how well the controllers in the model react to either insufficient levels of 3 He or excessive levels of 3 He. The simulations then explore potential impact from a delay in the measurement (or the response) that would be comparable to the ∼1 s, conductance limited response for the ITER DRGA system, currently in its final design. The simulations show that control is feasible, and that its effectiveness is not significantly impacted by such delay.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Polycrystalline silicon on tungsten substrates

Thin films of electron-beam-vaporized silicon were deposited on fine-grained tungsten substrates under a pressure of about 1 x 10 to the -10th torr. Mass spectra from a quadrupole residual-gas analyzer were used to determine the partial pressure of 13 residual gases during each processing step. During separate silicon depositions, the atomically clean substrates were maintained at various temperatures between 400 and 780 C, and deposition rates were between 20 and 630 A min. Surface contamination and interdiffusion were monitored by in situ Auger electron spectrometry before and after cleaning, deposition, and annealing. Auger depth profiling, X-ray analysis, and SEM in the topographic and channeling modes were utilized to characterize the samples with respect to silicon-metal interface, interdiffusion, silicide formation, and grain size of silicon. The onset of silicide formation was found to occur at approximately 625 C. Above this temperature tungsten silicides were formed at a rate faster than the silicon deposition. Fine-grain silicon films were obtained at lower temperatures.

Bevolo, A. J.

Efficient solar cells by space processing

Thin films of electron beam evaporated silicon were deposited on molybdenum, tantalum, tungsten and molybdenum disilicide under ultrahigh vacuum conditions. Mass spectra from a quadrapole residual gas analyzer were used to determine the partial pressure of 13 residual gases during each processing step. Surface contamination and interdiffusion were monitored by in situ Auger electron spectrometry. The presence of phosphorus in the silicon was responsible for attaining elevated temperatures with silicide formations. Heteroepitaxial silicon growth was sensitive to the presence of oxygen during deposition, the rate and length of deposition as well as the substrate orientation.

Schmidt, F. A.

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER