Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Relativistic Heavy Ion Collider”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Erratum: Centrality-Dependent Modification of Jet-Production Rates in Deuteron-Gold Collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV [Phys. Rev. Lett. 116, 122301 (2016)]

We previously reported jet-production rates in 𝑝 + 𝑝 and 𝑑 + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV recorded in 2008 with the PHENIX detector at the Relativistic Heavy Ion Collider. Subsequently, we found that electronic noise in the electromagnetic calorimeter was not completely removed by the tower-timing cuts used in the analysis. We have conducted an independent re-analysis of the data that eliminated noisy towers by removing them completely from the analysis. These cuts remove any contributions from instrumental noise, but reduce the overall acceptance for electromagnetic clusters by ≈16% and hence the overall statistical power of the data. Finally, this re-analysis found that instrumental noise in the electromagnetic calorimeter led to an artificial increase in the jet yield for both the 𝑝 + 𝑝 and 𝑑 + Au collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Low-mass vector-meson production at forward rapidity in 𝑝 + 𝑝 and Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV

The PHENIX experiment at the Relativistic Heavy Ion Collider has measured low-mass vector-meson (𝜔+𝜌 and 𝜙) production through the dimuon decay channel at forward rapidity (1.2 < |y| < 2.2) in 𝑝 + 𝑝 and Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV. The low-mass vector-meson yield and nuclear-modification factor were measured as a function of the average number of participating nucleons, ⟨𝑁 part ⟩, and the transverse momentum 𝑝 𝑇 . These results were compared with those obtained via the kaon decay channel in a similar 𝑝 𝑇 range at midrapidity. The nuclear-modification factors in both rapidity regions are consistent within the uncertainties. A comparison of the 𝜔 + 𝜌 and 𝐽/𝜓 mesons reveals that the light and heavy flavors are consistently suppressed across both 𝑝 𝑇 and ⟨𝑁 part ⟩. Finally, in contrast, the 𝜙 meson displays a nuclear-modification factor consistent with unity, suggesting strangeness enhancement in the medium formed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Small-x structure of oxygen and neon isotopes as seen by the Large Hadron Collider

Results on collisions of O-16 nuclei performed at the Relativistic Heavy Ion Collider (RHIC) have been presented for the first time at Quark Matter 2023 by the STAR collaboration. O-16+O-16 collisions are also expected to take place in the near future at the Large Hadron Collider (LHC) at much higher beam energies. We explore the potential of beam-energy-dependent studies for this system to probe small-x dynamics and QCD evolution. We perform 3+1D IP-Glasma simulations to predict the rapidity dependence of the initial geometry of light-ion collisions, focusing on O-16+O-16 and Ne-20+Ne-20 collisions at root s(NN) = 70 GeV and 7 TeV. The choice of Ne-20 is motivated by its strongly elongated geometry, which may respond differently to the effect of the high-energy evolution compared to the more spherical O-16. We find that smearing induced by soft gluon production at high energy causes mild variations in the initial-state eccentricities as a function of the collision energy. These effects could be resolved in future experiments and deserve further investigation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Large radial shift experiments in RHIC and their implications for EIC design

The Hadron Storage Ring (HSR) in the future Electron-Ion Collider (EIC) must operate over a broad range of design circumferences. In 2018 preliminary beam studies on the circumference adjustment capabilities of the Relativistic Heavy Ion Collider (RHIC) were performed by applying a small momentum offset to the circulating bunches without adjusting any bending magnets. The off-momentum linear optics were corrected back to on-momentum conditions. Applying a similarly small deviation to the dipole fields of a select set of bending magnets provides a large radial shift over much of the RHIC (or HSR) circumference while leaving the design trajectory unchanged in the insertion regions. Here, this paper presents the design of the different lattice configurations foreseen as the most viable options for the required HSR circumference changes, and highlights the modifications necessary for regular operations and to allow for testing these new settings in RHIC. Experimental results from 2021 and 2022 are reviewed and compared to model predictions obtained from both MAD-X and Bmad. The implications of these results for HSR design are discussed.

43 PARTICLE ACCELERATORS

Hard jet substructure in a multistage approach

We present predictions and postdictions for a wide variety of hard jet-substructure observables using a multistage model within the framework. The details of the multistage model and the various parameter choices are described in []. A novel feature of this model is the presence of two stages of jet modification: a high-virtuality phase [modeled using the modular all twist transverse-scattering elastic-drag and radiation model ()], where modified coherence effects diminish medium-induced radiation, and a lower virtuality phase [modeled using the linear Boltzmann transport model ()], where parton splits are fully resolved by the medium as they endure multiple scattering induced energy loss. Energy-loss calculations are carried out on event-by-event viscous fluid dynamic backgrounds constrained by experimental data. The uniform and consistent descriptions of multiple experimental observables demonstrate the essential role of modified coherence effects and the multistage modeling of jet evolution. Using the best choice of parameters from [], and with no further tuning, we present calculations for the medium modified jet fragmentation function, the groomed jet momentum fraction z g and angular separation r g distributions, as well as the nuclear modification factor of groomed jets. These calculations provide accurate descriptions of published data from experiments at the Large Hadron Collider. Furthermore, we provide predictions from the multistage model for future measurements at the BNL Relativistic Heavy Ion Collider. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Progress on the normal conducting magnets for the Electron-Ion Collider

The electron-ion collider (EIC) at Brookhaven National Laboratory (BNL) is designed to deliver a peak luminosity of 1e+34 1/cm2 1/sec. The EIC will take advantage of the existing Relativistic Heavy Ion Collider (RHIC) facility. Two additional rings will be installed: an electron storage ring (ESR) and a rapid cycling electron synchrotron ring (RCS).This paper presents an update on the normal conducting magnet designs required for both the ESR and RCS rings. The ESR will store polarized electron beams up to 18 GeV and utilizes a triplet of dipole magnets to increase the emittance at 5 GeV and generate excess bending to create additional radiation damping to allow a larger beam-beam tune shift. The RCS will accelerate single bunches of spin-polarized electrons at various energies from 5 GeV to 18 GeV, with a ramp rate of 100 ms and 1 Hz repetition rate. Both rings require dipole, quadrupole and sextupole magnets with different specifications.

43 PARTICLE ACCELERATORS

Rotators for the Hadron Storage Ring

The Electron Ion Collider calls for collisions of polarized electrons on transversely and longitudinally polarized protons and helions. To facilitate longitudinal polar ization, helical dipole rotator magnets from the Relativistic Heavy Ion Collider will be reused. These rotators are placed asymmetrically at -35.28 and 61.35 mrad from the interaction point. Longitudinal polarization of polarized protons cannot be satisfied for all energies while remaining below the maximum current of 322 A. Care has been taken to ensure longitudinal polarization can be satisfied at the energies of interest. The rotators ramping result in a shift in νs which has been compensated for with a change in the snake precession axes. The rotators can satisfy longitudinal polarization at all energies of interest, and the νs compensation has also been established.

43 PARTICLE ACCELERATORS

Unveiling Baryon Charge Carriers through Charge Stopping in Isobar Collisions

Utilizing a comprehensive (3 + 1)⁢D relativistic hydrodynamic framework with multiple conserved charge currents and charge-dependent lattice-QCD-based equation of state, we study the baryon and electric charge number deposition at midrapidity in isobar Ru + Ru and Zr + Zr collisions at the center of mass energy $\sqrt{s}_{NN}$ = 200 GeV. Comparing our predictions with upcoming experimental data from the Relativistic Heavy Ion Collider will shed light on the existence of baryon junctions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

2 Kelvin helium distribution system for the Electron Ion Collider’s 10 o’clock satellite refrigerator

The Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) will involve superfluid helium cooling of superconducting magnets and Superconducting Radio Frequency (SRF) cavities at several sites around the existing Relativistic Heavy Ion Collider (RHIC) accelerator tunnel. While the majority of the cooling power for these loads is provided by BNL’s central cryogenic plant, Jefferson Lab is designing satellite equipment which augments the central plant and enables 2 Kelvin operation. The 2 K cryogenic distribution system for the collider’s 10 o’clock location (Interaction Region 10 or IR10) includes all necessary interfaces to the IR10 Satellite Refrigerator, to the overall EIC cryogenic distribution system, and to 12 SRF cryomodules for the electron and hadron storage rings. In addition to providing the required cooling capacities in all operating modes, the IR10 2 K cryogenic distribution system also stabilizes the supply temperature and enables safe connection and disconnection of individual IR10 cryomodules. Moreover, the layout of the IR10 2 K cryogenic distribution system copes with challenging spatial constraints and adapts to the process configuration and routing of existing RHIC cryogenic distribution components which will be re-used for EIC. This paper gives a full overview of the IR10 satellite cryogenic distribution system design, and highlights some of the challenges encountered.

Laverdure, Nathaniel [Thomas Jefferson National Ac

Selection-bias effects on high-𝑝 𝑇 yield and correlation measurements in oxygen + oxygen collisions

Oxygen + oxygen (O+O) collisions at the BNL Relativistic Heavy Ion Collider (RHIC) and the CERN Large Hadron Collider (LHC) offer a unique experimental opportunity to observe the onset of jet quenching in intermediate relativistic collision systems. As with the smaller proton-nucleus or larger nucleus-nucleus systems, measurements of centrality-selected high-𝑝 T processes in O+O collisions are expected to be sensitive to selection bias effects, which will be necessary to quantify or mitigate before a definitive conclusion on the presence of jet quenching. Using two Monte Carlo heavy-ion event generators, we provide a survey of centrality bias effects on high-𝑝 T yield and correlation measurements. Some highlights of our findings include that (1) bias factors for the accessible kinematic range at RHIC show a nontrivial 𝑝 T dependence, compared to a negligible one at the LHC given the smaller accessible Bjorken-𝑥 range, (2) centrality definitions based on multiplicity are less sensitive to bias effects than those based on the transverse energy, (3) the Angantyr generator gives qualitatively similar but larger-magnitude bias factors than Hijing, and (4) correlation measurements have a much smaller sensitivity to bias effects than do yield measurements. Furthermore, the findings here are intended to guide the experimental design and interpretation of O+O jet quenching and other hard-process measurements.

Hard scattering

An Induction-Type Septum Magnet for the Hadron and Electron Injection of the EIC Complex

The design of the electron Ion Collider (EIC) project is under way to be built at the Brookhaven National Laboratory (BNL) with the collaboration of the Thomas Jefferson National Accelerator Facility (TJNAF). The Rapid Cycling Synchrotron (RCS) which is part of the EIC accelerator complex will accelerate the electron beam up to 18 GeV, and the beam will be injected into the Electron Storage Ring (ESR) to collide with the hadron beam circulating in the Hadron Storage Ring (HSR) which is a modified version of the Relativistic Heavy Ion Collider (RHIC). All three synchrotrons will be located in the same tunnel. This technical note provides information on the latest electromagnetic design of the induction-type septum magnet which will be employed by EIC to Inject the beam into the HSR and RCS and also extract the beam from the RCS.

43 PARTICLE ACCELERATORS

Engineering Design of D1/D3 Dipole Magnets for the Electron-Ion Collider (EIC)

Here, the Electron-Ion Collider (EIC) at Brookhaven National Laboratory (BNL) is designed to deliver a peak luminosity of 10 34 cm −2 s −1 . An electron storage ring (ESR) will be installed in the existing Relativistic Heavy Ion Collider (RHIC) tunnel and will store polarized electron beams from 5 to 18 GeV. The ESR will have 750 dipole magnets with varying field requirements, including 576 super-bend triplets consisting of two magnets D1/D3 and D2. This paper presents on the engineering design of the D1/D3 dipole magnets within the arcs, with special focus on the coil design that allows the magnet to be configured for variable ampere-turns per energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Design of the EIC hadron storage ring stripline injection kicker with a novel impedance tuning capability

The Electron-Ion Collider (EIC), to be built at Brookhaven National Laboratory, will be a high luminosity (~10 34 cm –2 s –1 ) nuclear science facility. To facilitate EIC experiments, the existing yellow ring of the Relativistic Heavy Ion Collider (RHIC) will be reconfigured to serve as the Hadron Storage Ring (HSR). Designing a stripline injection kicker for the HSR beams, with high magnetic rigidity (~ 82 Tm), poses some technical challenges due to the required large pulsed voltage with long flattop duration, very fast rise time, expected shorter bunch spacing, and potential heating due to higher peak current. In addition, minimizing impedance mismatch in the transition region between the feedthrough and the stripline electrode is challenging. This paper focuses on the mechanical design and optimization of the HSR injection kicker, highlighting a novel impedance tuning capability achieved through an innovative kicker aperture adjustment mechanism. We comprehensively cover the design, including impedance optimization (both beam coupling and characteristic), beam-induced heating, and thermal analysis, and investigation of the maximum electric field due to high voltage signal excitation to ensure safe and reliable operation.

43 PARTICLE ACCELERATORS

Centrality dependence of Lévy-stable two-pion Bose-Einstein correlations in $\sqrt{𝑠{𝑁⁢𝑁}}$ = 200 GeV Au + Au collisions

The PHENIX experiment measured the centrality dependence of two-pion Bose-Einstein correlation functions in $\sqrt{𝑠{𝑁⁢𝑁}}$ = 200 GeV Au + Au collisions at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory. The data are well represented by Lévy-stable source distributions. The extracted source parameters are the correlation-strength parameter 𝜆, the Lévy index of stability 𝛼, and the Lévy-scale parameter 𝑅 as a function of transverse mass 𝑚 𝑇 and centrality. The 𝜆⁡(𝑚 𝑇 ) parameter is constant at larger values of 𝑚 𝑇 , but decreases as 𝑚 𝑇 decreases. The Lévy-scale parameter 𝑅⁡(𝑚 𝑇 ) decreases with 𝑚 𝑇 and exhibits proportionality to the length scale of the nuclear overlap region. The Lévy exponent 𝛼⁡(𝑚 𝑇 ) is independent of 𝑚 𝑇 within uncertainties in each investigated centrality bin, but shows a clear centrality dependence. At all centralities, the Lévy exponent 𝛼 is significantly different from that of Gaussian (𝛼 = 2) or Cauchy (𝛼 = 1) source distributions. Comparisons to the predictions of Monte-Carlo simulations of resonance-decay chains show that, in all but the most peripheral centrality class (50%–60%), the obtained results are inconsistent with the measurements, unless a significant reduction of the in-medium mass of the 𝜂′ meson is included. Finally, in each centrality class, the best value of the in-medium 𝜂′ mass is compared to the mass of the 𝜂 meson, as well as to several theoretical predictions that consider restoration of U 𝐴⁢ (1) symmetry in hot hadronic matter.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

First-ever deployment of a SiPM-on-tile calorimeter in a collider: a parasitic test with 200 GeV p p collisions at RHIC.

We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV p p run in 2024. The prototype, measuring 20 × 20 cm 2 and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about 3.1 < η < 3.4. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about 10 10 1-MeV n eq /cm 2 . Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. AGeant4 detector simulation, with inputs from thePythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Variable rate neural compression for sparse detector data

Particle colliders produce data at extraordinary rates, posing major challenges for transmission and storage. High-throughput compression algorithms are therefore essential. In the sPHENIX experiment taking data at the Relativistic Heavy Ion Collider, a time projection chamber records three-dimensional (3D) particle trajectories that are highly sparse, making conventional learning-free lossy compression ineffective. Convolutional neural networks have surpassed traditional methods in compression ratio and accuracy. However, they fail to exploit sparsity for efficiency. To address these gaps, we present BCAE-VS, a bicephalous convolutional autoencoder with variable compression ratio for sparse data, which adapts compression to input complexity through key-point identification and sparse convolution. BCAE-VS achieves higher accuracy and compression ratios than prior neural approaches while being orders of magnitude smaller. Moreover, its throughput increases with sparsity—a property not observed in other methods. Although it was developed for collider experiments, BCAE-VS readily extends to other sparse data domains, such as light detection and ranging (LiDAR) sensing and 3D microscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Data-driven method to estimate contamination from light ion beam transmutation at colliders

Collisions of relativistic light ions, such as oxygen, neon, and magnesium, have been proposed as a way to examine the system-size dependence of dynamics typically associated with the quark-gluon plasma produced in collisions of heavier ions such as xenon, gold, or lead. Recent efforts at both the Relativistic Heavy Ion Collider (RHIC) and Large Hadron Collider (LHC) have produced large datasets of proton-oxygen, oxygen-oxygen, and neon-neon collisions, catalyzing intense interest in experimental backgrounds associated with light-ion collisions. In particular, electromagnetic dissociation of light ions while they are circulating in a collider can result in beam contamination that is difficult to simulate precisely. Here we propose a data-driven method for evaluating the potential impact of beam contaminants on physics analyses. The method exploits the time dependence and smaller size of contaminant ion species to define control regions that can be used to quantify potential contamination effects. A simple model is used to illustrate the method and to study its robustness. Furthermore, this method can inform studies of recent LHC and RHIC data and could also be useful for future light-ion programs at the LHC and beyond.

Beam loss

Optimal observables for the chiral magnetic effect from machine learning

The detection of the chiral magnetic effect (CME) in relativistic heavy-ion collisions remains challenging due to substantial background contributions that obscure the expected signal. In this Letter, we present a novel machine learning approach for constructing optimized observables that significantly enhance CME detection capabilities. By parametrizing generic observables constructed from flow harmonics and optimizing them to maximize the signal-to-background ratio, we systematically develop CME-sensitive measures that outperform conventional methods. Using simulated data from the anomalous viscous fluid dynamics framework, our machine learning observables demonstrate up to 90% higher sensitivity to CME signals compared to traditional 𝛾 and 𝛿 correlators, while maintaining minimal background contamination. The constructed observables provide physical insight into optimal CME detection strategies and offer a promising path forward for experimental searches of the CME at the BNL Relativistic Heavy Ion Collider and the CERN Large Hadron Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS