At least 37 records · Page 2

Accelerated radiation tolerance testing of Ti-based MAX phases

MAX phases have recently attracted significant attention for potential nuclear applications due to their novel properties such as unique hexagonal-compact nanolayered crystal structure, high-machinability due to lower hardness levels compared to conventional ceramics, and high-chemical inertness. In order for MAX phases to be used in nuclear reactors, two aspects deserve detailed investigations: (i) their phase stability at high-temperatures and (ii) microstructural defect formation and recovery induced by energetic particle irradiation. To date, degradation mechanisms of MAX phases at high-temperatures and following irradiation are largely unexplored fields of research. This work focuses on the evaluation of two Ti-based MAX phases – Ti 2 AlC and Ti 3 SiC 2 – within the context of extreme environments. To accomplish this, a one-of-a-kind comparison between neutron irradiations, performed over a decade of research at the High Flux Isotope Reactor (HFIR), and heavy-ion irradiations, carried out in situ in a Transmission Electron Microscope (TEM) at the MIAMI-2 facility, has been conducted. The results show Ti-based MAX phases are prone to accelerated decomposition under the conditions investigated. This questions the hypothesis that MAX phases exhibit high phase stability, especially when used in future nuclear energy systems where energetic particle irradiation is a dominating degradation mechanism.

36 MATERIALS SCIENCE↗

Accelerated Nuclear Radiation Effects on the Raspberry Pi 3B+ and Pi 4

Raspberry Pi™ computers running Linux and embedded benchmarks are subjected to radiation testing in the neutron beam at LANSCE. The ARM® Cortex®-A53 in the Raspberry Pi 3B+ versus ARM® Cortex®-A72 in the Raspberry Pi 4, single-core versus multi-core, and small versus large array SBU cross sections are compared. Results for the A53 and the A72 are similar. The results of one process on one of four cores and four identical processes on four cores are presented. The results of the array size show that there is more going on than just an increase in size. Linux is helpful in relating some errors that would have been classified as SEFI to an upset in a single bit.

36 MATERIALS SCIENCE↗

Lifecycle Management of Nuclear Security Radiation Detection Systems: Testing and Evaluation

The lifecycle of radiation detection systems functioning within a State’s Nuclear Security Detection Architecture encompasses all activities associated with acquisition, deployment, and eventual disposal. Throughout a system’s lifecycle, testing and evaluation activities are needed to ensure requirements are continually met, as underscored by recent experiences.This paper provides:1.A discussion of reasons why testing should be part of the radiation detection equipment lifecycle before, during, and after acquisition.2.A general process for determining applicable evaluation methods.3.A discussion of issues related to integrating testing and evaluation into procurement and operational processes and mitigation strategies.

Harris, Tyrone↗

Self-powered Through-wall communication for dry cask storage monitoring

Many nuclear facilities, such as spent fuel storage dry casks and nuclear reactor pressure vessels, are entirely sealed by metal layers to prevent harmful radiation. For safety and security operations, the temperature, pressure, radiation, and humidity inside the vessel needs to be closely monitored. However, no practical technology is currently available to realize the through-wall data communication and monitoring for these vessels due to the inside harsh environment of high temperature and nuclear radiation. In this paper, an innovative self-powered wireless through-wall data communication system for the nuclear environment is presented, which demonstrates a successful solution to such challenges. The presented system is composed of four modules, i.e., energy harvester with power management circuits, ultrasound wireless communication using high-temperature piezoelectric transducers, electronic circuits for sensing and data transmission, and radiation shielding for electronics. Here, constitutive functions of each module were firstly designed and followed by the system integration. Experiments were conducted subsequently to validate the designed functions and evaluate the performance of the integrated system. Results showed that the average power of over 40 mW was harvested from the thermal flow inside the nuclear spent fuel canisters which could provide enough energy to operate the sensing and data communication systems. The gamma radiation test results showed that the thermoelectric energy harvester and ultrasound transceivers can withstand radiation dosing over 100 Mrad. Furthermore, temperature shock tests demonstrated that the entire system including the shielded electronics can survive and maintain their functionalities at temperatures as high as 195°C. Under the in-lab mocked-up high temperature conditions and radiation shielding, the proposed system is foreseen to survive and operate stably for fifty years inside a nuclear spent fuel canister, and send the frequency modulated data out of the canister for 3 s in every 10 min.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Error Study of FlecSim Using the Method of Manufactured Solutions [Slides]

Error was calculated using exact solution chosen with the method of manufactured solutions. Hydrodynamics match expected order of accuracy for spatial error within 1.5% for all variables tested. Radiation transport matches expected order of temporal accuracy within 0.5% for all variables tested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Directed Flow and the Chiral Magnetic Effect in Ultrarelativistic Collisions at the LHC with CMS at the LHC (Final Technical Report)

This Technical Report focuses on two aspects of this project. First, the results from the calibration of the Spectator Reaction Plane Detector (SRPD) addition to the Zero Degree Calorimeter (ZDC) in the CMS experiment are presented, followed by the pre-liminary results from radiation studies of quartz being performed using the electron linac here at the University of Maryland. The data taken in the November 2018 run are being analyzed with the ultimate goal of producing a reaction plane measurement using spectator neutrons detected in the ZDC. Funds provided by this grant partially supported the graduate student who is performing these calibrations. They were also used to support radiation tests of quartz rod material being performed at the University of Maryland Radiation Facilities Electron Linear Accelerator.

43 PARTICLE ACCELERATORS↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

Special Issue of Nuclear Science and Engineering celebrates the Tenth Anniversary of Operations at NCERC

The National Criticality Experiments Research Center (NCERC) is a general-purpose critical experiment facility, the only one in the US and one a few that remain operational throughout the world. NCERC is located at the Nevada National Security Site (NNSS), formerly known as the Nevada Test Site, and is operated by Los Alamos National Laboratory (LANL). This year, NCERC celebrated its 10th year of operation. To commemorate the first ten years of operations and experiments, a special issue of Nuclear Science and Engineering was prepared with papers focusing on each of the four critical assemblies and one on Radiation Test Object (RTO) measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

RD53 pixel readout integrated circuits for ATLAS and CMS HL-LHC upgrades

The RD53 collaboration has since 2013 developed new hybrid pixel detector chips with 50 × 50 μm2 pixels for the HL-LHC upgrades of the ATLAS and CMS experiments at CERN. A common architecture, design and verification framework has been developed to enable final pixel chips of different sizes to be designed, verified and tested to handle extreme hit rates of 3 GHz/cm2 (up to 12 GHz per chip) together with an increased trigger rate of 1 MHz and efficient readout of up to 5.12 Gbits/s per pixel chip. Tolerance to an extremely hostile radiation environment with 1 Grad over 10 years and induced SEU (Single Event Upset) rates of up to 100 upsets per second per chip have been major challenges to make reliable pixel chips. Three generations of pixel chips, and many specific mixed signal building blocks and radiation test chips, have been submitted and extensively tested to get to final production chips. The large, complex and high rate pixel chips have been developed with a strong emphasis on low power consumption together with a concurrent development and qualification of novel serial powering at chip, module and system level, to minimize detector material budget.

Alimonti, G↗

Development of an Enhanced Radiation Physics Toolset for Modeling Spectral and Imaging Signatures in the Warm Dense Matter Experiments

Radiative and atomic processes in plasmas play a critical role in a wide variety of high energy density laboratory plasma (HEDLP) experiments. The emission, absorption, and transport of radiation can strongly affect the overall energetics and evolution of such plasmas. In addition, radiation-based diagnostics – including imaging, spectroscopy, and absolute flux measurements – are widely used to determine key features of HEDLPs. To advance our understanding of HEDLP science, it is vital to have high-fidelity computational physics tools that have well-tested radiation physics modeling, and that are readily accessible to researchers in the HEDLP community. Simulations play an extremely important role for planning and designing the experiments, as well as for post-experiment data analysis. Prism Computational Sciences develops software that is used by National Laboratories and universities (including five members of LaserNetUS network). Prominent examples of such research efforts include z-pinch and short-pulse laser experiments designed to study the basic physics of photoionized plasmas and photoionization fronts, as well as their application to astrophysical plasmas. The main effort was dedicated to the development of non-equilibrium equation-of-state (EOS) models within the HELIOS-CR code, a hydrodynamics code with inline collisional-radiative atomic kinetics. Gas cell experiments on Z and Omega demonstrated the importance of non-equilibrium effects on atomic kinetics in photoionized plasmas. Recent proof-of-principle experiments on Omega EP confirmed the advantages of using a short-pulse laser to create an intense radiation drive, leading to additional experiments being proposed. Photoionization front experiments at LLE also emphasizes the importance of radiation and atomic physics. In both studies, HELIOS-CR simulations played a crucial role in computing non-equilibrium opacities and ionization distributions. A newly developed non-LTE EOS model will help addressing possible non-equilibrium effects, on for example specific heat, and their influence in plasma evolution. Prism also implemented support for open-source atomic data generated by the Flexible Atomic Code. This allows researchers to generate custom atomic tables and use them within the complex framework of simulation tools developed by Prism. The ability to use open-source atomic data would be extremely valuable for hydrodynamics and spectroscopic simulations that include high-Z materials, e.g., picosecond x-ray pulse generation experiments. Support for new atomic structures was fully implemented, and the data can be used by all simulation tools developed at Prism: radiation-hydrodynamics, imaging and spectroscopy, EOS and opacity. The development resulted in a significant fidelity enhancement to the simulations tools developed by Prism that are currently used in other cutting-edge experiments including: opacity measurement experiments performed to both understand the basic radiative and atomic properties of plasmas as well as provide data for more accurately modeling the internal structure of the Sun and other stars, high-intensity short-pulse laser experiments performed to develop short-wavelength light sources for use as backlighters and to investigate fast ignition concepts for inertial fusion energy; capsule implosion experiments designed to develop inertial fusion as an energy source, etc.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Testing of the Endcap Concentrator ASICs for the CMS High-Granularity Calorimeter Upgrade

A major upgrade of the High-Granularity Calorimeter (HGCAL) in the CMS detector is planned for Long-Shutdown 3 (LS3), currently expected to start in 2026. This upgrade will contain over 6 million channels and the electronics will be required to be low power and to withstand a radiation environment with a High-Energy Hadron flux of 3x10**6 particles per square centimeter per second. The solution to this significant challenge is the two Endcap Concentrator (ECON) ASICs, ECON-T and ECON-D, working in tandem with the HGCROC front-end ASIC. The two ECON ASICs provide critical on-detector data reduction for both the 40 MHz trigger path (ECON-T) and 750 kHz data acquisition path (ECON-D) of the HGCAL. The ASICs are fabricated in 65nm CMOS. They are rad-tolerant to 600 Mrad with low power consumption (<2.5 mW/channel). This presentation will be a comprehensive description of each ECON design, including the infrastructure that they share as well as the elements that make each unique. The presentation will also include functionality and radiation tests for both ASICs, and the first high statistics characterization results from the full production of 75k ECON-D and ECON-T ASICs.

Hoff, James R. [Fermilab] (ORCID:0000000163514592)↗

First test results of the HGCAL concentrator ASICs: ECON-T and ECON-D

With over 6 million channels, the High Granularity Calorimeter for the CMS HL-LHC upgrade presents a unique data transmission challenge. The ECON ASICs provide a critical stage of on-detector data compression and selection for the trigger path (ECON-T) and data acquisition path (ECON-D) of the HGCAL. The ASICs, fabricated in 65 nm CMOS, are radiation tolerant up to 200 Mrad and require low power consumption: < 2.5 mW/sensor-channel per chip. Here, we report on the first functionality and radiation tests for the ECON-D-P1 full-functionality prototype. We present a comparison of single event effect (SEE) cross sections measured for different methods of triple modular redundancy using test results from the ECON-T-P1 full-functionality prototype.

47 OTHER INSTRUMENTATION↗

Spatially and temporally resolved plasma parameter estimations of laser heated MagLIF relevant gas pipes at NIF

The ability to control laser pre-heat is an integral part of the inertial confinement fusion concept known as Magnetized Liner Inertial Fusion. This process is studied at the National Ignition Facility (NIF) where 4 of the 192 laser beams are propagated through a 1-cm long gas cell where they deposit >20 kJ of energy into the gaseous fuel via inverse bremsstrahlung absorption. This process ionizes the gas, producing a plasma that follows behind the laser front and expands over the radius of the cell. Emission from this plasma, as viewed by a gated x-ray detector, can be used to build spatially and temporally resolved estimations of the pre-heat plasma's density and temperature profiles. This can then be used to estimate the plasma pressure, internal energy, and radiation losses. Estimations show the evolution of the plasma in magnetized and unmagnetized gas cells filled with ambient temperature neopentane (C5H12) +1% Ar, as well as unmagnetized cryogenically cooled (32 K) deuterium +1% Ne filled targets. This analysis shows the effects of initial gas-fill density, composition, and axial magnetization on the time-dependent plasma parameters. Previously, these parameters at the NIF had not been experimentally characterized, and these estimations provided a potential new means of testing radiation magneto-hydrodynamic predictive capability models. Results in unmagnetized targets have strong agreement with simulations. However, in targets with a 19 T applied axial magnetic field, this method yields electron temperatures up to 100% hotter than those predicted by HYDRA codes.

Bremsstrahlung↗

CMS HGCAL ECON-D ASIC : Impact of CMOS fabrication process tuning on performance and radiation tolerance

The CMS experiment’s High Granularity Calorimeter (HGCAL) upgrade will replace CMS’s existing endcap calorimeters in preparation for the High Luminosity LHC. To effectively use over 6 million channels of this “imaging”calorimeter, CMS has developed two novel Endcap Concentrator (ECON) ASICs to perform data compression/selection on detector. The ECON-D ASIC operates on the 750kHz data path, and the ECON-T ASIC on the 40MHz trigger path. These 65 nm CMOS ASICs are radiation tolerant to 200 Mrad and low power, operating at less than 2.5 mW/channel. The first full-functionality prototype ECONs were produced and characterized in 2021-23, and an initial engineering run was performed in 2024. ECON-D radiation testing for the engineering run revealed that the chip’s internal SRAMs produce intermittent read errors for a non-negligible fraction of chips. Further investigation indicated that the SRAM performance is highly sensitive to the exact parameters of the CMOS fabrication process. To both study this process sensitivity and mitigate SRAM performance issues, twenty ECON wafers were produced in 2025 with a range of doping concentrations designed to tune the underlying transistor threshold voltage by 0%, 5%, 10%, and 15% from nominal. This talk will present first measurements of ECON-D performance, power consumption, and radiation tolerance for these four variations of CMOS process.

Syal, Chinar [Fermilab]↗

The MUSE beamline calorimeter

The MUon Scattering Experiment (MUSE) was motivated by the proton radius puzzle arising from the discrepancy between muonic hydrogen spectroscopy and electron–proton measurements. The MUSE physics goals also include testing lepton universality, precisely measuring two-photon exchange contribution, and testing radiative corrections. MUSE addresses these physics goals through simultaneous measurement of high precision cross sections for electron–proton and muon–proton scattering using a mixed-species beam. The experiment will run at both positive and negative beam polarities. Measuring precise cross sections requires understanding both the incident beam energy and the radiative corrections. For this purpose, a lead-glass calorimeter was installed at the end of the beam line in the MUSE detector system. Here, in this article, we discuss the detector specifications, calibration and performance. We demonstrate that the detector performance is well reproduced by simulation, and meets experimental requirements.

Calorimeter↗

Impacts of Substrate Thinning on FPGA Performance and Reliability [Slides]

Substrate thinning is necessary in devices with flip-chip BGA packages to enable both radiation testing and component qualification and high-spatial resolution beam-based failure analysis methods. We investigated three factors affecting device performance: subsurface damage from the thinning process, reduced heat spreading in thin substrates, and changes in device switching speed. We conclude subsurface damage to crystalline Si caused by the thinning process is removable with sufficient SiO 2 slurry polishing. Local temperature differences increase minimally in devices thinned to 3 μm. Compressive stress in the Si increases globally after device thinning and leads to slowing of ring oscillator frequency by about 0.5% compared to full-thickness devices. Future work will include extending the results to submicron Si thickness values, which also has important benefits for failure analysis, debug, and security assessments. We also plan to extend this type of work to other FPGAs and other devices like memory and processors.

36 MATERIALS SCIENCE↗