At least 37 records · Page 2

Nuclear Targets for a Precision Measurement of the Neutral Pion Radiative Width

A technique is presented for precision measurements of the area densities, density * T, of approximately 5% radiation length carbon and 208Pb targets used in an experiment at Jefferson Laboratory to measure the neutral pion radiative width. The precision obtained in the area density for the carbon target is +/- 0.050%, and that obtained for the lead target through an x-ray attenuation technique is +/- 0.43%.

43 PARTICLE ACCELERATORS↗

T-1075: Large Area Fast Timing Beam Time of Flight (LAFTBToF) for ProtoDUNE

Large-area Picosecond Photodetectors (LAPPDs), developed at Argonne National Laboratory (ANL), present an opportunity to provide identification of charged particles in the 2-10 GeV/c range. Traditional methods using ionization or Cherenkov detectors require large amounts of material or pathlength for the particle to traverse in order to get a clean measurement, and are ill suited for particle beam identification in fixed-target experiments. The 6x6 cm 2 LAPPD uses mm-thick borosilicate glass micro-channel plates with a resistive surface coating added via atomic layer deposition. An electrical connection schematic of the LAPPD is shown in Figure 1. Electrons emitted by the photocathode are accelerated through the MCPs, which have µm-sized capillaries, and an avalanche of electrons is created as the electrons collide against the walls of the capillaries of the MCPs. The resulting electron avalanche is collected on anode strip lines and the signal may be read out on both ends of the stipline. The resistive coating of the thin MCPs and the short path length of the electrons to the readout results in fast rise times, gains of greater than 10 6 and typical timing resolutions of 50 ps. Differential timing on the ends of the strip lines can provide mm-level position measurements. The material of the bare LAPPD presents less than 0.05 of an interaction length and approximately 0.12 of a radiation length for a charged particle of I GeV/c. In our application, two large-area photodetectors separated by 5-10 meters can be used in a time-of-flight (ToF) measurement for 3σ separation of2-7 GeV/c charged pions, kaons and protons with minimal impact on the particle's trajectory and momentum.

43 PARTICLE ACCELERATORS↗

Measurement of the Iron Spectrum in Cosmic Rays from 10 GeV/n to 2.0 TeV/n with the Calorimetric Electron Telescope on the International Space Station

The Calorimetric Electron Telescope (CALET), in operation on the International Space Station since 2015, collected a large sample of cosmic-ray iron over a wide energy interval. In this paper a measurement of the iron spectrum is presented in the range of kinetic energy per nucleon from 10GeV/n to 2.0 TeV/n allowing the inclusion of iron in the list of elements studied with unprecedented precision by space-borne instruments. The measurement is based on observations carried out from January 2016 to May 2020. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z = 40). The energy is measured by a homogeneous calorimeter with a total equivalent thickness of 1.2 proton interaction lengths preceded by a thin (3 radiation lengths) imaging section providing tracking and energy sampling. The analysis of the data and the detailed assessment of systematic uncertainties are described and results are compared with the findings of previous experiments. The observed differential spectrum is consistent within the errors with previous experiments. In the region from 50 GeV/n to 2 TeV/ n our present data are compatible with a single power law with spectral index−2.60±0.03.

O Adriani↗

Observation of a THz-sub-THz spontaneous coherent undulator radiation driven by a low energy electron beam from a thermionic RF electron gun

In this work, we report observations of an intense, multi-band, sub-THz and THz radiation extracted from a similar to 2-3 MeV electron beam with a flat transverse profile propagating in an oversized rectangular waveguide placed into a 3.25 mm gap of a planar undulator having 1.3 cm period and similar to 20 cm length. Radiation outcoupling is accomplished using a horn antenna and a miniature permanent in-vacuum magnet separating the mm-sub-mm-waves and electron beam. A table-top experiment utilizes a radio frequency thermionic electron gun delivering a thousand momentum-chirped microbunches per macropulse and an alpha-magnet producing microbunches of a sub-mm length. Total radiated energy of a sub-millijoule per a microsecond radio frequency macropulse is demonstrated with flux more than ten micro-Joules per centimeter squared. With 1 THz filter the energy measured is about 1 microjoule and flux of a few micro-Joules per centimeter squared.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Vertex Detector Cable Considerations

Vertex detector cable requirements are considered within the context of the SiD concept. Cable material should be limited so that the number of radiation lengths represented is consistent with the material budget. In order to take advantage of the proposed accelerator beam structure and allow cooling by flow of dry gas, 'pulsed power' is assumed. Potential approaches to power distribution, cable paths, and cable design for operation in a 5 T magnetic field are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

APEX: An electron fixed-target experiment to search for a new vector boson A′ Decaying to e{sup +}e{sup −}

The A' EXperiment (APEX) is designed to search for new vector bosons that have small couplings to charged particles. Such vectors can arise naturally from a small kinetic mixing of a new 'dark photon' (A') with the photon - one of the very few ways in which new forces can couple to the Standard Model - and have received considerable attention as an explanation of various dark matter related anomalies. A' bosons are produced by radiation off an electron beam, and could appear as narrow resonances with small production cross-section in the QED e{sup +}e{sup −} spectrum. We plan to search for an A' using the CEBAF electron beam at energies of 1-4 GeV incident on 0.5-10% radiation length multi-foil tungsten targets, and measure the resulting e{sup +}e{sup −} pairs using the High Resolution Spectrometers and a septum magnet in Hall A at Jefferson Lab. With a 33-day run, APEX will explore the region 50 MeV < m{sub A′} < 550 MeV with couplings alpha'/alpha down to 10{sup −7}. This proceeding summarizes the experiment, test run results, and comments on future plans.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Techniques for detecting the Cherenkov light from cascade showers in water

The NEVOD Cherenkov water detector (CWD) features a denser lattice of sensitive elements than the existing large-scale CWDs, whereby the spatial distribution of Cherenkov light from cascade showers is sampled with a superior resolution of ~0.5 m, which is close to one radiation length for water (36 cm). The experimental techniques for investigating the Cherenkov light generated by particle cascades in water is proposed. The dependence of light intensity on the depth of shower development is for the first time measured at different distances from the shower axis. The results are compared with the Cherenkov light distributions predicted by various model descriptions for the scattering of cascade particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Cylindrical GEM Detector with Analog Readout for the BESIII Experiment

Inner Trackers (IT) are key detectors in Particle Physics experiments; excellent spatial resolution, radiation transparency and hardness, and operability under high occupancies are main requirements. We aim to design, build and commission by 2017 a Cylindrical GEM (CGEM) detector candidate to be the new IT of the BESIII spectrometer, hosted on BEPC2 in IHEP, Beijing; BESIII data taking will last until at least 2020. The IT itself will represent an evolution w.r.t. the state of the art of GEM detectors, since the use of new kind of mechanical supports for the GEM foils will reduce the total radiation length of the detector and improve its tracking performance; an innovative design of the CGEM anode will allow for smaller capacitance and hence for bigger signals. The relatively strong BESIII magnetic field requires a new analogue readout; full custom front-end electronics, including a dedicated ASIC, will be designed and produced for optimal data collection. Prototype Beam Test results showing the measurement of the spatial resolution in a 1 Tesla magnetic field will be presented among with the mechanical design and simulations. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ATIC Experiment: Elemental Spectra from the Flight in 2000

The Advanced Thin Ionization Calorimeter (ATIC) had successful Long Duration Balloon flights from McMurdo, Antarctica in both 2000 and 2002. The instrument consists of a silicon matrix charge detector, a 0.75 nuclear interaction length graphite target, 3 scintillator strip hodoscopes, and an 18 radiation length thick BGO calorimeter to measure the cosmic ray composition and energy spectra from approximately 30 GeV to near 100 TeV. In this paper, we present preliminary results from the first flight, which was a test flight that lasted for 16 days, starting on 12/28/00.

Ahn, H. S.↗

Lead tungstate calorimeters at Jefferson Lab and perspectives for the Electron–Ion Collider

Electromagnetic calorimeters based on PbWO4 scintillating crystals have a widespread applica- tion in experiments at different accelerator facilities such as CERN, FNAL, GSI, and Jefferson Lab. The unique properties of PbWO4 crystals, including a small radiation length and Molire radius, make them ideal for building high-granularity, radiation-hard detectors. This enables excellent spa- tial separation and energy resolution of reconstructed electromagnetic showers, making PbWO4 crystals the material of choice for numerous experiments. Lead tungstate calorimeters have been successfully used in several experiments at Jefferson Lab. Two large-scale detectors have been re- cently fabricated for future experiments : the Neutral Particle Spectrometer and the lead tungstate calorimeter of the GlueX detector. The future application of PbWO4 crystals in the ElectronIon Collider further highlights their ongoing importance in advancing experimental capabilities. In planning new experiments, the development of calorimeter instrumentation technologies becomes paramount. The integration of modern photodetectors, such as Silicon photomultipliers that are capable of operating in strong magnetic fields, and the implementation of streaming readout data acquisition systems, sophisticated shower reconstruction algorithms, and real-time data analysis are some examples of the continuously growing requirements of experimental setups. I will give an overview of the lead tungstate scintillating calorimeters and discuss some recent advancement in the calorimeter instrumentation.

Somov, Alexander↗

The Jefferson Lab Eta Factory Experiment and Applications of PbWO4 Calorimeters in Future Experimental Facilities

The goal of the new JLab Eta Factory (JEF) experiment, conducted with the GlueX detector in Hall D at Jefferson Lab, is to perform measurements of various ¿(') decays with a primary focus on rare neutral modes. The experiment’s physics program ranges from precision tests of low-energy QCD to searches for gauge bosons with masses below 1 GeV that could couple the Standard Model (SM) sector to the dark sector. The experiment will collect a high-statistics data sample of ¿(') mesons produced via a beam of tagged photons. The GlueX detector features a large, nearly uniform acceptance for both neutral and charged particles, enabling efficient identification of complex multi-particle final states. To meet the requirements of the JEF experiment, the inner section of the forward lead-glass calorimeter in the GlueX detector has been upgraded with lead tungstate (PbWO4) scintillating crystals. PbWO4 offers exceptional characteristics, such as a small radiation length and Molire radius, and large light yield, that make it ideal for constructing high- granularity, high-resolution, radiation-hard detectors. These properties enable excellent spatial separation and energy resolution of reconstructed electromagnetic showers, establishing PbWO4 as the material of choice for many high-precision experiments. The JEF experiment began data collection in April 2025 and will operate concurrently with the GlueX experiment, whose primary objective is the search for gluonic excitations in the meson spectrum. I will give an overview of the JEF experiment, the GlueX detector, and the feasibility of further upgrades to support future ¿ physics studies. Special attention will be given to the newly constructed PbWO4 scintillating calorimeter and recent advancements in calorimeter instrumentation.

Somov, Alexander↗

The Energy Spectra of Proton and Helium Measured from the ATIC Experiment

The Advanced Thin Ionization Calorimeter (ATIC) balloon experiment is designed to investigate the composition and energy spectra of cosmic rays at the highest energies currently accessible from direct measurements, the region up to 100 TeV. The instrument consists of a silicon matrix for charge measurement, a graphite target (0.75 nuclear interaction length) to induce hadronic fragmentation, 3 scintillator strip hodoscopes for triggering and helping reconstruct trajectory, and a BGO calorimeter (18 radiation lengths) to measure the energy of incident particles. ATIC had two successful Long Duration Balloon (LDB) flights from McMurdo, Antarctica: from 12/28/00 to 01/13/01 and from 12/29/02 to 01/18/03. We present the energy spectra of proton and helium extracted from the ATIC flights, over the energy range from 100 GeV to 100 TeV, and compare them with the results from other experiments at both the lower and higher energy ends.

Ahn, H. S.↗

A Concept for a High-Energy Gamma-ray Polarimeter

We present a concept for an imaging gamma-ray polarimeter operating from approx. 50 MeV to approx. 1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The concept makes use of pixelized gas micro-well detectors, under development at Goddard Space Flight Center, to record the electron-positron tracks from pair-production events in a large gas volume. Pixelized micro-well detectors have the potential to form large-volume 3-D track imagers with approx. 100 micron (rms) position resolution at moderate cost. The combination of high spatial resolution and a continuous low-density gas medium permits many thousands of measurements per radiation length, allowing the particle tracks to be imaged accurately before multiple scattering masks their original directions. The polarization of the incoming radiation may then be determined from the azimuthal distribution of the electron-positron pairs. We have performed Geant4 simulations of these processes to estimate the polarization sensitivity as a function of instrument parameters and event selection criteria.

Bloser, P. F.↗

Performance of a Quintuple-GEM Based RICHDetector Prototype

Cerenkov technology is often the optimal choice for particle identification in high energy particle collision applications. Typically, the most challenging regime is at high pseudorapidity (forward) where particle identification must perform well at high laboratory momenta. For the upcoming electron ion collider (EIC), the physics goals require hadron (π, K, p) identification up to ~50 GeV/c. In this region Cerenkov ring-imaging (RICH) is the most viable solution. The speed of light in a radiator medium is inversely proportional to the refractive index. Hence, for particle identification (PID) reaching out to high momenta a small index of refraction is required. Unfortunately, the lowest indices of refraction also result in the lowest light yield ([(dNγ)/dx] ∝ sin2(θC)) driving up the radiator length and thereby the overall detector cost. In this paper we report on a successful test of a compact RICH detector (1 meter radiator) capable of delivering in excess of 10 photoelectrons per ring with a low index radiator gas (CF4). The detector concept is a natural extension of the PHENIX hadron-blind detector (HBD) achieved by adding focusing capability at low wavelength and adequate gain for high efficiency detection of single-electron induced avalanches. Our results indicate that this technology is indeed a viable choice in the forward direction of the EIC. The setup and results are described within.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

E166: Polarized Positrons and Polarimetry

A proof-of-principle experiment has been carried out in the Final Focus Test Beam (FFTB) at Stanford Linear Accelerator Center (SLAC) to demonstrate production of polarized positrons in a manner suitable for implementation at the International Linear Collider (ILC). A helical undulator of 2.54 mm period and 1 -m length produced circularly polarized photons with a first harmonic endpoint energy of 8 MeV when traversed by a 46.6 GeV electron beam. The polarized photons were converted to polarized positrons in a 0.2-radiation-length tungsten target. The polarization of these positrons was measured using a Compton transmission polarimeter to have peak value in excess of 80%.

43 PARTICLE ACCELERATORS↗

E166: Polarized Positrons & Polarimetry

A proof-of-principle experiment has been carried out in the Final Focus Test Beam (FFTB) at Stanford Linear Accelerator Center (SLAC) to demonstrate production of polarized positrons in a manner suitable for implementation at the International Linear Collider (ILC). A helical undulator of 2.54 mm period and 1 -m length produced circularly polarized photons with a first harmonic endpoint energy of 8 MeV when traversed by a 46.6 GeV electron beam. The polarized photons were converted to polarized positrons in a 0.2-radiation-length tungsten target. The polarization of these positrons was measured using a Compton transmission polarimeter to have peak value in excess of 80%.

43 PARTICLE ACCELERATORS↗

First-ever deployment of a SiPM-on-tile calorimeter in a collider: a parasitic test with 200 GeV p p collisions at RHIC.

We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV p p run in 2024. The prototype, measuring 20 × 20 cm 2 and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about 3.1 < η < 3.4. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about 10 10 1-MeV n eq /cm 2 . Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. AGeant4 detector simulation, with inputs from thePythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗