Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION LENGTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Standard value for the radiation length in air

The radiation length in air, was studied. Calculations were finished and give new values for t sub o in atomic oxygen and nitrogen which are entirely free of dependence on the Thomas-Fermi approximate model. With the usual small corrections for atmospheric A and CO2, these give t sub o air = 37.15 g cm/2, in close agreement with a value recommended, but in contrast to t sub o air = 36.66 g cm/2 obtained using the Thomas-Fermi approximation.

Linsley, J.↗

Measurement of the fractional radiation length of a pixel module for the CMS Phase-2 upgrade via the multiple scattering of positrons

High-luminosity particle collider experiments such as theones planned at the High-Luminosity Large Hadron Collider requireever-greater vertexing precision of the tracking detectors,necessitating reductions in the material budget of the detectors.Traditionally, the fractional radiation length (x/X$_{0}$) ofdetectors is either estimated using known properties of theconstituent materials, or measured in dedicated runs of the finaldetector. In this paper, we present a method of direct measurementof the material budget of a CMS prototype module designed for thePhase-2 upgrade of the CMS detector using a 40–65 MeV positronbeam. A total of 630 million events were collected at the PaulScherrer Institut PiE1 experimental area using a three-planetelescope consisting of the prototype module as the central plane,surrounded by two MALTA monolithic pixel detectors. Fractionalradiation lengths were extracted from scattering angle distributionsusing the Highland approximation for multiple scattering. Astatistical technique recovered runs suffering from triggerdesynchronisation, and several corrections were introduced tocompensate for local inefficiencies related to geometric and beamshape constraints. Two regions of the module were surveyed andyielded average x/X$_{0}$ values of (0.72 ± 0.05)% and(0.95 ± 0.09)%, which are compatible with empirical estimatesfor these regions computed from known material properties of 0.753%and 0.892%, respectively. Two types of higher-granularity maps ofthe fractional radiation length were produced, subdivided eitherinto rectangular regions of uniform size, or polygonal-shapedregions of uniform material composition. The results bode well forthe CMS Phase-2 upgrade modules, which will play a key role in theminimisation of the material of the upgraded detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The radiation length

Total screening, bremsstrahlung, and pair production in atomic electron field

PAIR PRODUCTION↗

Direct Measurement of the Nickel Spectrum in Cosmic Rays in the Energy Range from 8.8 GeV/$\mathcal{n}$ to 240 GeV/$\mathcal{n}$ with CALET on the International Space Station

The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other transiron elements; therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than ~ 3 GeV/n are available at present in the literature, and they are affected by strong limitations in both energy reach and statistics. In this Letter, we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n , carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z = 40 ). The particle’s energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This Letter follows our previous measurement of the iron spectrum [O. Adriani et al. (CALET Collaboration), Phys. Rev. Lett. 126, 241101 (2021).], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV/n our present data are compatible within the errors with a single power law with spectral index -2.51 ± 0.07 .

79 ASTRONOMY AND ASTROPHYSICS↗

Precision Measurement of the Nickel Spectrum in Cosmic Rays from 8.8 GeV/n to 240 GeV/n with CALET on the International Space Station

The relative abundance of nickel with respect to iron is by far larger than all other trans-iron elements, therefore it provides a favourable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the source and to model the propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than∼3 GeV/n are available at present in the literature and they are affected by strong limitations in both energy reach and statistics. In this paper we present a measurement of the differential energy spectrum of nickel from 8.8 GeV/nto 240 GeV/n, carried out with unprecedented precision by the Calorimetric Electron1 Telescope(CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z = 40). The particle’s energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This paper follows our previous measurement of the iron spectrum [1] and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 GeV/nto 240 GeV/n our present data are compatible within the errors with a single power law with spectral index−2.51±0.07.

O Adriani↗

Measurement of the nuclear electromagnetic cascade development in glass at energies above 200 GeV

The longitudinal development of nuclear-electromagnetic cascades with energies greater than 200 GeV was measured in a low-Z (glass) absorber. This was done in the course of operating an ionization spectrometer at mountain altitude in an experiment to study the properties of gamma rays emitted from individual interactions at energies around 10,000 GeV. The ionization produced by a cascade is sampled by 20 sheets of plastic scintillator spaced uniformly in depth every 2.2 radiation lengths. Adjacent pairs of scintillators are viewed by photomultipliers which measure the mean ionization produced by an individual cascade in 10 layers each 1.1 interaction length (4.4 radiation lengths) thick. The longitudinal development of the cascades was measured for about 250 cascades having energies ranging from 200 GeV to 2500 GeV. The observations are compared with the predictions of calculations made for this specific spectrometer using a three-dimensional Monte Carlo model of the nuclear-electromagnetic cascade.

Gillespie, C. R.↗

The primary cosmic ray electron spectrum from 10 GeV to about 200 GeV

An ionization spectrometer consisting of 10.8 radiation lengths of tungsten and 35 radiation lengths of iron has been used to determine the energy spectrum of cosmic ray electrons above 10 GeV. The spectrometer was calibrated with electrons from 5.4 to 18 GeV and then flown at an altitude of 6 gm-cm/2 for 16 hours. Separation of electron initiated events from proton events was achieved by utilizing starting point distributions, the shower development in tungsten, and the energy deposited in the large thickness of iron absorber. The exponent of the differential energy spectrum of the electrons is -3.1 + or - 0.2 while the exponent of the background is consistent with the proton exponent of -2.7 + or -0.2.

Silverberg, R. F.↗

Analysis of Potential Target Materials for the Mu2e Production Target

The need for high intensity secondary beams in particular muon beams is becoming increasingly evident, necessitating innovation in target design. Ideal muon production targets are temperature stable while producing high muon yields. We have identified radiation length and nuclear interaction length as proxies for these parameters, with longer radiation length decreasing energy deposition in the target and shorter nuclear interaction length increasing muon yield. In this poster, we summarize some of our analysis of potential target materials in relation to these factors.

43 PARTICLE ACCELERATORS↗

A range muon tomography performance study for the detection of explosives

Soft cosmic ray tomography has been shown to successfully discriminate materials with various density levels due to their ability to deeply penetrate matter, allowing sensitivity to atomic number, radiation length and density. Because the multiple muon scattering signal from high Z-materials is very strong, the technology is well suited to the detection of the illicit transportation of special and radiological nuclear materials. In addition, a recent detection technique based on measuring the lower energy particles that do not traverse the material (range radiography), allows to discriminate low and medium Z-materials. This is shown in [4] using Monte Carlo simulations. More recently, using a mini muon tracker developed at Los Alamos National Laboratory, we performed various experiments to try out the radiation length technology. This paper presents the results from real experiments and evaluates the likelihood that soft cosmic ray tomography may be applied to detect high-explosives.

36 MATERIALS SCIENCE↗

On the scattering power of radiotherapy protons

Purpose: First, to show that accurate formulas for scattering power T must take into account the competition between the Gaussian core and the single scattering tail of the angular distribution, which affects the rate of change in the Gaussian width and leads to the single scattering correction (SSC). Second, to show that the SSC requires that T(x) be nonlocal: Besides material properties and energy at the point of interest, it must depend in some fashion on how much multiple scattering has already taken place. Third, after reviewing five previous formulas (three local and two nonlocal), to derive an improved ''differential Moliere'' formula T{sub dM}. Last, to investigate, by studying some practical cases, when an accurate formula for T is actually needed. Methods: We first take the numerical derivative of the Moliere/Fano/Hanson <{theta}{sup 2}> in order to find the true SSC. We simplify the formula for T{sub IC} (ICRU Report 35) for protons, introducing a new material dependent property, the ''scattering length''X{sub S}, analogous to radiation length X{sub 0}. We then use T{sub IC} as a basis for T{sub dM} by including a nonlocal correction factor f{sub dM} which, by virtue of the Oeveraas approximation, parametrizes the single scattering correction. Results: The improved scattering power is T{sub dM}{identical_to}f{sub dM}(pv,p{sub 1}v{sub 1})x(E{sub s}/pv){sup 2}1/X{sub S} where f{sub dM}{identical_to}0.5244+0.1975 lg(1-(pv/p{sub 1}v{sub 1}){sup 2})+0.2320 lg(pv)-0.0098 lg(pv)lg(1-(pv/p{sub 1}v{sub 1}){sup 2}), p{sub 1}v{sub 1} (MeV) is the initial product of proton momentum and speed, pv is the same at the point of interest, and E{sub s}=15.0 MeV. T{sub dM} is easily computed and generalizes readily to mixed slabs because f{sub dM} is not material dependent. Conclusions: Whether an accurate formula for T is required depends very much on the problem at hand. For beam spreading in water, five of the six formulas for T give almost identical results, suggesting that patient dose calculations are insensitive to T. That is not true, however, of beam spreading in Pb. At the opposite extreme, the projected rms beam width at the end of a Pb/Lexan/air stack, analogous to the upstream modulator in a passive beam spreading system, is sensitive to T. In this case a simple experiment would discriminate between all but two of the six formulas discussed. Scattering power applies as much to Monte Carlo as to deterministic transport calculations. Using T in any of its forms will avoid step size dependence. Using the best available T could be important in general purpose Monte Carlo codes, which are expected to give the correct answer to many different problems.

61 RADIATION PROTECTION AND DOSIMETRY↗

The shape of the primary cosmic ray electron spectrum above 10 GeV

A balloon borne measurement of the cosmic ray electron spectrum above 10 GeV is reported in which two new techniques have been used to remove proton background contamination. First, the depth of the spectrometer on one of the flights was more than 40 radiation lengths, enabling hadronically and electromagnetically induced cascades to be differentiated for a subset of the data. Second, electromagnetic cascade starting points were determined to within about 0.1 radiation lengths based upon a calibration with electrons from 5.4 to 18 GeV at the Stanford Linear Accelerator. The resulting spectrum, when fitted with a power law, is steep, but the fit is marginal. A significantly better fit is achieved by assuming a model in which the spectrum is steepening in the measured region.

Silverberg, R. F.↗

Primary cosmic ray electrons above 10 GeV: Evidence for a spectral break

A balloon borne measurement of the cosmic ray electron spectrum from 10 to 200 GeV is reported in which two new techniques have been used to remove proton background contamination. First, the depth of the spectrometer was more than 25 radiation lengths, the equivalent of more than 2 mean free paths of material, enabling hadronically and electromagnetically induced cascades to be differentiated for a subset of the data. Second, electromagnetic cascade starting points were determined to within + or - 0.1 radiation lengths based upon a calibration with electrons from 5.4 to 18 GeV at the Stanford Linear Accelerator, greatly reducing the chances for a proton to simulate an electron. The resulting spectrum, when fitted with a power law, is quite steep, -3.2 + or - 0.1, but the chi-square fit is marginal. A significantly better fit is achieved assuming a transition region model in which the source spectral index is 2.7 with a break occurring at about 50 GeV.

Silverberg, R. F.↗

Primary cosmic ray electrons above 10 GeV - Measurements using a thick detector

A balloon-borne measurement of the cosmic ray electron spectrum from 10 to 200 GeV is reported in which two new techniques have been used to remove proton background contamination. First, the depth of the spectrometer was more than 40 radiation lengths, the equivalent of more than 3 mean free paths of material, enabling hadronically and electromagnetically induced cascades to be differentiated for a subset of the data. Second, electromagnetic cascade starting points were determined to within plus or minus 0.1 radiation lengths on the basis of a calibration with electrons from 5.4 to 18 GeV at the Stanford Linear Accelerator, greatly reducing the chances for a proton to simulate an electron. The resulting spectrum, when fitted with a power law, is quite steep, -3.2 plus or minus 0.1, but the fit to a power law is marginal.

Silverberg, R. F.↗

Distorted Coulomb field of the scattered electron

Experimental results for the radiation emission from ultrarelativistic electrons in targets of 0.03%-5% radiation length is presented. For the thinnest targets, the radiation emission is in accordance with the Bethe-Heitler formulation of bremsstrahlung, the target acting as a single scatterer. In this regime, the radiation intensity is proportional to the thickness. As the thickness increases, the distorted Coulomb field of the electron that is the result of the first scattering events, leads to a suppressed radiation emission per interaction, upon subsequent scattering events. In that case, the radiation intensity becomes proportional to a logarithmic function of the thickness, due to the suppression. Eventually, once the target becomes sufficiently thick, the entire radiation process becomes influenced by multiple scattering and the radiation intensity is again proportional to the thickness, but with a different constant of proportionality. The observed logarithmic thickness dependence of radiation intensity at intermediate values of the thickness can be directly interpreted as a manifestation of the distortion of the electron Coulomb field resulting from a scattering event. The Landau-Pomeranchuk-Migdal effect is explored with high primary energy using materials with low nuclear charge (Z). Also, targets that should give rise to the claimed interference effect in high-energy radiation emission from a structured target of thin foils are investigated.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An electron fixed target experiment to search for a new vector boson A' decaying to e + e -

We describe an experiment to search for a new vector boson A' with weak coupling alpha' > 6 x 10 –8 α to electrons (α' = e 2 /4π) in the mass range 65 MeV < m A' < 550 MeV. New vector bosons with such small couplings arise naturally from a small kinetic mixing of the "dark photon" A' with the photon -- one of the very few ways in which new forces can couple to the Standard Model -- and have received considerable attention as an explanation of various dark matter related anomalies. A' bosons are produced by radiation off an electron beam, and could appear as narrow resonances with small production cross-section in the trident e + e - spectrum. We summarize the experimental approach described in a proposal submitted to Jefferson Laboratory's PAC35, PR-10-009. This experiment, the A' Experiment (APEX), uses the electron beam of the Continuous Electron Beam Accelerator Facility at Jefferson Laboratory (CEBAF) at energies of ~1-4 GeV incident on 0.5-10% radiation length Tungsten wire mesh targets, and measures the resulting e+e- pairs to search for the A' using the High Resolution Spectrometer and the septum magnet in Hall A. With a ~1 month run, APEX will achieve very good sensitivity because the statistics of e+e- pairs will be ~10,000 times larger in the explored mass range than any previous search for the A' boson. These statistics and the excellent mass resolution of the spectrometers allow sensitivity to α'/α one to three orders of magnitude below current limits, in a region of parameter space of great theoretical and phenomenological interest. Similar experiments could also be performed at other facilities, such as the Mainz Microtron.

43 PARTICLE ACCELERATORS↗

An Electron Fixed Target Experiment to Search for a New Vector Boson A' Decaying to e+e-

We describe an experiment to search for a new vector boson A' with weak coupling {alpha}' {approx}> 6 x 10{sup -8} {alpha} to electrons ({alpha} = e{sup 2}/4{pi}) in the mass range 65 MeV < m{sub A'} < 550 MeV. New vector bosons with such small couplings arise naturally from a small kinetic mixing of the 'dark photon' A' with the photon - one of the very few ways in which new forces can couple to the Standard Model - and have received considerable attention as an explanation of various dark matter related anomalies. A' bosons are produced by radiation off an electron beam, and could appear as narrow resonances with small production cross-section in the trident e{sup +}e{sup -} spectrum. We summarize the experimental approach described in a proposal submitted to Jefferson Laboratory's PAC35, PR-10-009. This experiment, the A' Experiment (APEX), uses the electron beam of the Continuous Electron Beam Accelerator Facility at Jefferson Laboratory (CEBAF) at energies of {approx} 1-4 GeV incident on 0.5-10% radiation length Tungsten wire mesh targets, and measures the resulting e{sup +}e{sup -} pairs to search for the A' using the High Resolution Spectrometer and the septum magnet in Hall A. With a {approx} 1 month run, APEX will achieve very good sensitivity because the statistics of e{sup +}e{sup -} pairs will be {approx} 10,000 times larger in the explored mass range than any previous search for the A' boson. These statistics and the excellent mass resolution of the spectrometers allow sensitivity to {alpha}'/{alpha} one to three orders of magnitude below current limits, in a region of parameter space of great theoretical and phenomenological interest. Similar experiments could also be performed at other facilities, such as the Mainz Microtron.

43 PARTICLE ACCELERATORS↗