Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Pre-combustion CO2 capture”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

21 records · Page 2

Levelized Cost of CO 2 Captured Using Five Physical Solvents in Pre-combustion Applications

Aspen Plus v8.8 was used to perform techno-economic analysis (TEA) of a CO 2 capture process from a typical fuel gas stream in a 543-MW pre-combustion power plant using five different physical solvents (Selexol, PEGPDMS-1, NMP, [aPy][Tf 2 N] and [hmim][Tf 2 N]). The process included a countercurrent packed-bed absorber operating under high-pressure over a wide range of temperatures and three pressure-swing flash drums for solvent regeneration. Furthermore, two packings, Mellapak 250Y and IMTP50, were used and the Levelized costs of CO 2 captured (LCOC) were calculated. The simulation results indicated that using Mellapak 250Y exhibited lower LCOC values than those when using IMTP50 for the five solvents under all conditions used as it offered better mass transfer. The CO 2 capture process carried out at low temperatures showed lower LCOC values than those at higher temperatures due to the increased CO 2 solubility in the solvents at lower temperatures, requiring smaller absorber diameter and lower solvent circulation rates, which offset the cooling requirements. Comparing the lowest LCOC values for the five solvents, the hydrophobic PEGPDMS-1 solvent was the most promising one compared to the other four solvents, due to its lowest capital and operating costs and noncorrosive, which enabled using less expensive materials for the process equipment.

42 ENGINEERING↗

High-Temperature Ceramic-Carbonate Dual-Phase Membrane Reactor for Pre-combustion Carbon Dioxide Capture (Final Scientific/Technical Report)

Arizona State University, in collaboration with University of South Carolina, worked on a project aimed at development of a new high temperature, high pressure CO 2 perm-selective membrane reactor for water-gas-shift reaction (WGS) with simulated gasifier syngas to produce a high concentration H 2 stream with CO 2 capture. The membrane reactor is made of a CO 2 semi-permeable ceramic-carbonate dual-phase (CCDP) membrane with high CO 2 perm-selectivity/permeance and thermal/mechanical stability for application in WGS reaction. The objectives of this project were to (1) synthesize the chemically/thermally stable tubular CCDP membranes with CO 2 permeance and selectivity (with respect to H 2 , CO or H 2 O) larger than 6.5×10-7 mol/m2·s·Pa and 500, respectively; (2) establish CCDP membrane reactor setup and study high pressure CO 2 permeation and WGS reaction with CO 2 capture using the setup; and (3) identify conditions for WGS in the CCDP membrane reactor that produce CO 2 and H 2 streams with purity of >99% and >90% respectively at CO conversion >95% and overall carbon capture >90%. The work in this project included both membrane development and membrane reactor process study. The membrane development efforts were focused on investigating a H 2 S resistant and highly oxygen-ionic conducting metal oxide material and membrane for CO 2 separation, fabrication of tubular samaria-doped-ceria/molten-carbonate CCDP membrane with high mechanical strength, and experimental and modeling study of high-pressure CO 2 permeation of the CCDP membranes. Mathematical models were developed to describe WGS in the CCDP membrane reactor without a catalyst or packed with a commercial high temperature WGS catalyst. Experiments on WGS in the CCDP membrane reactor with the commercial WGS catalyst, guided by the model analysis, were performed to identify optimum conditions for achieving the CO conversion, carbon capture, and the purity of the H 2 and CO 2 streams mentioned above. At 30 atm feed pressure, 750°C operation temperature, space velocity of 250 h-1, and with steam sweep, a single-stage CCDP membrane reactor with average CO 2 permeation flux of 0.5 cm3(STP)/min.cm2 can achieve CO 2 conversion of 95% and overall carbon capture of 94%, and produce CO 2 and H 2 streams with dry-based purity of >99% and 92% respectively. The project also included process design and techno-economic analysis (TEA) for a CCDP membrane reactor process for WGS reaction with CO 2 capture for a 550 MW coal-fired IGCC power plant, and its comparison with the conventional fixed-bed reactor system for WGS with follow-up CO 2 capture by an amine absorption process. The target performance for the reactor for WGS with CO 2 capture includes CO conversion >95%, hydrogen stream purity >90%, CO 2 stream purity >95%, and total carbon capture >90%. The CCDP membrane developed in this project can achieve the performance target, without subsequent CO 2 capture process at the optimum conditions identified in this project. The outcome of the process design and TEA analysis shows that the membrane reactor for WGS with in-situ CO 2 capture has an operating cost about 40% lower than that for the conventional fixed-bed reactor with a separate amine absorption process for CO 2 capture. However, the capital cost of the membrane reactor process is about twice that of the conventional process because of the higher cost of the CCDP membrane. Modeling analysis shows that a membrane reactor using a CCDP membrane with higher CO 2 permeance (about three times the current value) can deliver the targeted performance for WGS reaction with CO 2 capture at a much higher space velocity and lower membrane surface area to catalyst volume ratio, leading to a smaller catalyst amount and/or membrane area and hence significantly reduced membrane reactor capital costs.

20 FOSSIL-FUELED POWER PLANTS↗

Pilot Testing of a Highly Efficient Pre-combustion Sorbent-based Carbon Capture System

TDA developed and demonstrated a highly efficient pre-combustion carbon capture system. The overall objective of this work was to develop a new sorbent-based pre-combustion carbon capture technology for Integrated Gasification Combined Cycle (IGCC) power plants. In this project our goal was to demonstrate the techno-economic viability of the new technology by 1) demonstrating it in large-scale slipstream tests, and 2) carrying out a high fidelity engineering and cost analysis. TDA’s process used an advanced physical adsorbent that selectively removes CO 2 from coal-derived synthesis gas above the dew point of the gas at temperatures as high as 300°C. The sorbent consists of a mesoporous carbon whose surface was grafted with functional groups that remove CO 2 via a well-known acid-base interaction. As documented in bench-scale experiments and field tests with actual coal gas, the sorbent achieved a very high capacity for CO 2 at temperatures as high as 300°C. The sorbent bound CO 2 more strongly than common physical adsorbents, providing the chemical potential needed for the high temperature operation. However, because CO 2 does not form a true covalent bond with the surface sites (as is the case with chemical absorbents), the sorbent regeneration could be carried out with only a very small energy input. The heat input to regenerate our sorbent was only 4.9 kcal per mol of CO 2 , which is much lower than that for chemical absorbents (e.g., 29.9 kcal/mol CO 2 for sodium carbonate) and was similar to the requirements of physical solvents (e.g., 4 kcal/mol CO 2 for Selexol TM ). Because the sorbent operates above the dew point of the synthesis gas (unlike the Selexol TM process), a higher power cycle efficiency can be achieved. With previous DOE/NETL funding (Contract No. DE-FE-0000469), we demonstrated the techno-economic viability of the technology in bench-scale tests and slipstream demonstrations at the National Carbon Capture Center (NCCC), Wilsonville, Alabama and Wabash River IGCC plant in Terra Haute, Indiana. We demonstrated a stable working CO 2 capacity for over 11,650 cycles with simulated synthesis gas. We also evaluated its performance with actual synthesis gas in two test campaigns at the Wabash River IGCC Plant, Terre Haute, IN and the National Carbon Capture Center (NCCC), Wilsonville, AL. The slipstream tests clearly showed that the actual coal gas constituents and potential contaminants (e.g. trace metals, halides, tars) had no effect on the sorbent’s ability to remove CO 2 (the same sorbent beds were used in both field tests with no sign of deactivation for 2,000 cycles with over 26,750 SCF of gas treated). As expected, due to the high temperature CO 2 removal capability and low energy needed to regenerate the sorbent, the power cycle efficiency with our process was greater than 34% on a higher heating value (HHV) basis; in comparison, the same IGCC plant equipped with the Selexol TM solvent for carbon capture can only achieve 31.4% HHV efficiency. The capital cost for an IGCC system with TDA’s process is estimated as $2,417/kW e , which is 12% lower than that of the IGCC/ Selexol TM process. The levelized cost for electricity including the transport, storage and monitoring (TS&M) cost for CO 2 was calculated as $\$ $92.9/MWh (lowest reported to our knowledge), which is much better than the $105.2/MWh estimated for the IGCC/ Selexol TM process. In this project (DE-FE0013105), TDA Research, in collaboration with our partners Gas Technology Institute (GTI), Illinois Clean Coal Institute (ICCI), University of California, Irvine (UCI), University of Alberta (UOA), Siemens, NCCC and Sinopec advanced the technical maturity of the technology; scaling it up by a factor of 100. We optimized the reactor design using computational fluid dynamics (CFD); using adsorption modeling we improved the pressure swing adsorption (PSA) cycle sequence. We carried out two field test campaigns with a fully-equipped 0.1 MW e prototype unit (for a total of 844 hours) using actual synthesis gas to prove the viability of the new technology. A successful 30 day (707 hrs) evaluation was completed at NCCC under air blown gasification conditions. We demonstrated 97.3% carbon capture at 1,500 SLPM, 93% carbon capture at 1,800 SLPM, and 90% carbon capture at 2,100 SLPM in the NCCC tests. We also demonstrated the system for 137 hours at a Sinopec petrochemical plant under oxygen blown gasification, demonstrating 86% carbon capture at 2,660 SLPM. In collaboration with University of California, Irvine (UCI), we completed a techno-economic analysis (TEA) for TDA’s warm gas cleanup technology integrated to IGCC power plant. The net plant efficiencies (on a coal HHV basis) for the warm gas cleanup cases were estimated to be 34.0% for E-GasTM gasifier, 34.4% for GE gasifier, 33.4 for the Shell gasifier and 34.2 for the TRIG TM gasifier (Cases 2, 4, 6 and 8 in this study) with a catalytic combustor for CO 2 purification, which are significantly higher than those for the Cold Gas Case, or an increase of as much as 12% in the heat rate for Case 2, 6% for Case 4, 9% for Case 6, and 9% for Case 8. The 1st year cost of electricity with the transport, storage and monitoring (TS&M) costs for the CO 2 included was $\$ $129.2/MWh for the E-GasTM gasifier Warm Gas Cleanup Case, $\$ $131.9/MWh for the GE gasifier Warm Gas Cleanup Case, $\$ $146.8/MWh for the Shell Gasifier Warm Gas Cleanup Case, and $\$ $129.9/MWh for the TRIG TM gasifier Warm Gas Cleanup Case. For comparison, the costs for the baseline Cold Gas CO 2 removal with Selexol for the different gasifiers were: $\$ $146.6/MWh for the E-Gas TM gasifier, $\$ $142.2/MWh for the GE gasifier, $\$ $159.0/MWh for the Shell gasifier and $\$ $144.3/MWh for the TRIG TM gasifier. In summary, the costs for our system were 7 to 12% lower than the corresponding Cold Gas Cleanup cases. The results of this techno-economic analysis suggested that TDA’s high temperature PSA-based Warm Gas Clean-up Technology can make a substantial improvement in the IGCC plant thermal performance for achieving near zero CO 2 emissions for E-Gas TM , GE, Shell and TRIG TM gasifier based IGCC power plants. The capital expenses were estimated to be lower than that of Selexol’s™. Taken together, the higher net plant efficiency and lower capital and operating costs resulted in substantial reduction in the cost of carbon capture for the IGCC plant equipped with TDA’s high temperature PSA-based carbon capture system. Finally, in collaboration with Gas Technology Institute (GTI) we completed the environmental health and safety assessment for TDA’s warm gas carbon capture technology.

01 COAL, LIGNITE, AND PEAT↗