Engineering PapersSearch

SEARCH · Engineering Papers

Results for “PULSE RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Impact of Gaps in the NASA-ISRO SAR Mission Swath

The NASA-ISRO Synthetic Aperture Radar (NISAR) mission will carry L-band and S-band SAR instruments, each with a 240 km swath width. The L-band instrument has the capability to map the entire Earth’s land and ice covered surfaces from both ascending and descending orbit positions, continuously in an exact 12 day repeating cycle, given temporally dense (better than 6-day on average) sampling of Earth over the life of the mission. To achieve this swath coverage without loss of resolution or polarimetric capability, NISAR uses a reflector-feed based antenna system with scan-on-receive (“SweepSAR”) capability. One of the characteristics of SweepSAR is that the pulse repetition interval of the radar is shorter than the echo receive window for the 240 km swath. Therefore, transmit events occur during the receive window and the receivers must be blanked periodically, creating gaps in the coverage. For fixed pulse rate operations, these gaps are persistent strips of blanked ranges. NISAR is being designed to allow variation of the pulse rate in order to spread out these gaps throughout the synthetic aperture, but processing these variably-acquired data is more challenging and can lead to compromises in image quality. At the highest level NISAR places requirements on science measurements rather than image quality, so there is often a debate among science and engineering team members as to whether to operate with fixed pulse rates – leading to range strips consistently blank from cycle to cycle but with optimal image quality – or to vary the pulse rate, fill in the gaps, and live with degraded image quality. NISAR’s performance team has shown that science requirements can be met with the gaps. However, scientists are eager for maximum and coverage within a swath. A companion paper (Villano et al.) describes image quality for NISAR using a variable PRF approach, but does not go further to science requirements. This paper explores the issues when gaps are present in the swath due to fixed PRF operations.

Veeramachaneni, Chandini

Pulse transducer with artifact signal attenuator

An artifact signal attenuator for a pulse rate sensor is described. The circuit for attenuating background noise signals is connected with a pulse rate transducer which has a light source and a detector for light reflected from blood vessels of a living body. The heart signal provided consists of a modulated dc signal voltage indicative of pulse rate. The artifact signal resulting from light reflected from the skin of the body comprises both a constant dc signal voltage and a modulated dc signal voltage. The amplitude of the artifact signal is greater and the frequency less than that of the heart signal. The signal attenuator circuit includes an operational amplifier for canceling the artifact signal from the output signal of the transducer and has the capability of meeting packaging requirements for wrist-watch-size packages.

Cash, W. H., Jr.

Low and High-Power Inductive Pulsed Plasma Thruster Development Testing at NASA-MSFC

The inductive pulsed plasma thruster (IPPT) is an electromagnetic plasma accelerator that has been identified in NASA roadmaps as an enabling propulsion technology for some niche low-power missions and for high-power in-space propulsion needs. The IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged producing a high current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. Thrusters of this type possess many demonstrated and potential benefits that make them worthy of continued investigation. The electrodeless nature of these thrusters eliminates the lifetime and contamination issues associated with electrode erosion in conventional electric thrusters. Also, a wider variety of propellants are accessible when compatibility with metallic electrodes in no longer an issue. IPPTs have been successfully operated using propellants like ammonia, hydrazine, and CO2, and there is no fundamental reason why they would not operate on other in situ propellants like H2O. It is well-known that pulsed accelerators can maintain constant specific impulse (I(sub sp)) and thrust efficiency (eta(sub t)) over a wide range of input power levels by adjusting the pulse rate to hold the discharge energy per pulse constant. It has also been demonstrated that an inductive pulsed plasma thruster can operate in a regime where eta(sub t) is relatively constant over a wide range of I(sub sp) values (3000-8000 s). Finally, thrusters in this class have operated in single-pulse mode at high energy per pulse, and by increasing the pulse rate they offer the potential to process very high levels of power using a single thruster. There has been significant previous research on IPPTs designed around a planar-coil (flat-plate) geometry. The most notable of these was the Pulsed Inductive Thruster (PIT), with the PIT MkV presently representing the state-of- the-art in pulsed high-power IPPT technological development. In this paper, we focus on two planar-geometry devices that operate at significantly different power levels. Most work performed at NASA-Marshall Space Flight Center (MSFC) has, to date, focused on lower power thruster operation (approx. = 10s to 100s of J/pulse, up to 2-2.5 kW average power throughput) and previously described. The most recent work aimed to assemble a device that could be tested in cyclic mode on a thrust-stand, and which could augment the existing data set for IPPTs. In addition, the thruster was designed to serve as a test-bed for solid state switching circuitry and pulsed gas valves, with the modular design of the device allowing for variation in or upgrades to test configuration. Recently, MSFC obtained on loan from the Georgia Institute of Technology (Atlanta, GA) the PIT MkVI, successor to the PIT MkV. The MkV and MkVI are similar in design with much of the hardware from the former, specifically the capacitors and spark-gap switches, being reused in the latter. The coil is similar in geometry but has bent copper rods used in the latest iteration in place of the Litz wire windings found in the MkV. The MkVI master switch for the spark gaps is located in the vacuum chamber contained within a sealed, pressurized vessel fastened to the back of the thruster. This is different from the MkV where many capacitor charging lines and spark gap-triggering delay lines ran to the thruster from a master trigger located outside the vacuum chamber. The MkVI was damaged during testing soon after its fabrication was completed. The thruster arrived at MSFC still-damaged and mostly disassembled into many individual pieces. The device has been repaired, with a few additional design changes implemented after discussions with the late Prof. Lovberg regarding the initial testing results and issues encountered. In the present work, we present results from testing of both the small IPPT and the larger MkVI thruster. The smaller device (Fig. 1) is tested on a thrust stand on multiple gases to demonstrate its capability to operate in a repetition-rate mode and serve as a IPPT technology-development testbed. The larger MkVI (Fig. 2) is operated for the first time in its newly reconstituted state, demonstrating full-power pulsed operation and, for the first time, repetition-rate operation of a high-power IPPT. The additional upgrades required for synchronous operation of all the pulsed systems in single-pulse and repetition-rate mode are described in detail.

Polzin, Kurt A.

Inductive Pulsed Plasma Thruster Development Testing at NASA-MSFC

The inductive pulsed plasma thruster (IPPT) is an electromagnetic plasma accelerator that has been identified in NASA roadmaps as an enabling propulsion technology for some niche low-power missions and for high-power in-space propulsion needs. The IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged producing a high current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. Thrusters of this type possess many demonstrated and potential benefits that make them worthy of continued investigation. The electrodeless nature of these thrusters eliminates the lifetime and contamination issues associated with electrode erosion in conventional electric thrusters. Also, a wider variety of propellants are accessible when compatibility with metallic electrodes in no longer an issue. IPPTs have been successfully operated using propellants like ammonia, hydrazine, and CO2, and there is no fundamental reason why they would not operate on other in situ propellants like H2O. It is well-known that pulsed accelerators can maintain constant specific impulse (I(sub sp)) and thrust efficiency (η(sub t)) over a wide range of input power levels by adjusting the pulse rate to hold the discharge energy per pulse constant. It has also been demonstrated that an inductive pulsed plasma thruster can operate in a regime where η(sub t) is relatively constant over a wide range of I(sub sp) values (3000-8000 s). Finally, thrusters in this class have operated in single-pulse mode at high energy per pulse, and by increasing the pulse rate they offer the potential to process very high levels of power using a single thruster. There has been significant previous research on IPPTs designed around a planar-coil (flat-plate) geometry. The most notable of these was the Pulsed Inductive Thruster (PIT), with the PIT MkV presently representing the state of- the-art in pulsed high-power IPPT technological development. In this paper, we focus on two planar-geometry devices that operate at significantly different power levels. Most work performed at NASA-Marshall Space Flight Center (MSFC) has, to date, focused on lower power thruster operation (≈ 10s to 100s of J/pulse, up to 2-2.5 kW average power throughput) and previously described in Refs. [5,6]. The most recent work aimed to assemble a device that could be tested in cyclic mode on a thrust-stand, and which could augment the existing data set for IPPTs. In addition, the thruster was designed to serve as a test-bed for solid state switching circuitry and pulsed gas valves, with the modular design of the device allowing for variation in or upgrades to test configuration. Recently, MSFC obtained on loan from the Georgia Institute of Technology (Atlanta, GA) the PIT MkVI, successor to the PIT MkV. The MkV and MkVI are similar in design with much of the hardware from the former, specifically the capacitors and spark-gap switches, being reused in the latter. The coil is simliar in geometry but has bent copper rods used in the latest iteration in place of the Litz wire windings found in the MkV. The MkVI master switch for the spark gaps is located in the vacuum chamber contained within a sealed, pressurized vessel fastened to the back of the thruster. This is different from the MkV where many capacitor charging lines and spark gap-triggering delay lines ran to the thruster from a master trigger located outside the vacuum chamber. The MkVI was damaged during testing soon after its fabrication was completed. The thruster arrived at MSFC still-damaged and mostly disassembled into many individual pieces. The device has been repaired, with a few additional design changes implemented after discussions with the late Prof. Lovberg regarding the initial testing results and issues encountered.

Polzin, Kurt A.

A Flight Evaluation of an Airborne Physiological Instrumentation System, Including Preliminary Results Under Conditions of Varying Accelerations

A physiological instrumentation system capable of recording the electrocardiogram, pulse rate, respiration rate, and systolic and diastolic blood pressures during flight has been developed. This instrumentation system was designed for use during control studies at varied levels of acceleration in order to monitor the well-being of the pilot and at the same time to obtain data for study of the relationships between his various physiological functions and his performance capability. Flights, made in a T-33 aircraft, demonstrated the ability of the system to obtain the desired physiological data in flight. The data obtained in these flights, although limited in nature, indicate a slowing of the pulse rate under the subgravity conditions of brief duration. There appeared to be a proportional nearly in-phase relationship between pulse rate and acceleration. A decrease in diastolic blood pressure together with an increase in pulse pressure was noted during subgravity conditions and an elevation of the diastolic pressure together with a decrease in pulse pressure du-ring increased accelerations. No change worthy of note was seen in the records of the systolic blood pressure, the respiration rate, or the electrocardiogram over the range of acceleration studied (0 to 3 g).

Smedal, Harald A.

Airborne Laser Polar Nephelometer

A polar nephelometer has been developed at NCAR to measure the angular variation of the intensity of light scattered by air molecules and particles. The system has been designed for airborne measurements using outside air ducted through a 5-cm diameter airflow tube; the sample volume is that which is common to the intersection of a collimated source beam and the detector field of view within the airflow tube. The source is a linearly polarized helium-neon laser beam. The optical system defines a collimated field-of-view (0.5deg half-angle) through a series of diaphragms located behind a I72-mm focal length objective lens. A photomultiplier tube is located immediately behind an aperture in the focal plane of the objective lens. The laser beam is mechanically chopped (on-off) at a rate of 5 Hz; a two-channel pulse counter, synchronized to the laser output, measures the photomultiplier pulse rate with the light beam both on and off. The difference in these measured pulse rates is directly proportional to the intensity of the scattered light from the volume common to the intersection of the laser beam and the detector field-of-view. Measurements can be made at scattering angles from 15deg to 165deg with reference to the direction of propagation of the light beam. Intermediate angles are obtained by selecting the angular increments desired between these extreme angles (any multiple of 0.1deg can be selected for the angular increment; 5deg is used in normal operation). Pulses provided by digital circuits control a stepping motor which sequentially rotates the detector by pre-selected angular increments. The synchronous photon-counting system automatically begins measurement of the scattered-light intensity immediately after the rotation to a new angle has been completed. The instrument has been flown on the NASA Convair 990 airborne laboratory to obtain data on the complex index of refraction of atmospheric aerosols. A particle impaction device is operated simultaneously to collect particles from the same airflow tube used to make the scattered-light measurements. A size distribution function is obtained by analysis of the particles collected by the impaction device. Calculated values of the angular variation of the scattered-light intensity are obtained by applying Mie scattering theory to the observed size distribution function and assuming different values of the complex index of refraction of the particles. The calculated values are then compared with data on the actual variation of the scattered-light intensity obtained with the polar nephelometer. The most probable value of the complex refractive index is that which provides the best fit between the experimental light scattering data and the parameters calculated from the observed size distribution function.

Grams, Gerald W.

Physiologic reactions during five weeks of continuous residence in an artificial humid and hot climate

During 5 weeks in a climatic room, total sweat during work almost doubled. Initial hour differences increasingly equalized. There was a displacement of sweat secretion from trunk to extremities till the end of week 3, occurring earlier and more clearly for the arm than for the leg. Work temperatures dropped rapidly and evenly to a constant level by day 11. Circulation behavior matched that of temperature. Pulse rate during work dropped like rectal temperature and pulse rate during rest was phasically like the pattern of corresponding temperatures. Except for the first days urine output was adequate and even, Na decreasing in the urine until week 3, then returning to initial values. Na and K in sweat declined but with opposite patterns for hours 1-4. Total salt elimination decreased. The conclusive phenomena of redistribution occurred within the first 3 weeks. A few functions changed later also. Relatively trivial changes in an otherwise uniform reaction pattern indicated that after 3 or even 5 weeks of acclimatization the process is not over or at least not completely so. The tempo of the process appears to be a function of the degree of loading.

Laaser, U.

Impact of ultrafast laser pulse repetition rate on filament acoustic and emission signatures

Femtosecond filaments formed at standoff distances can be used for interrogating various types of matter, making them of potential interest for remote sensing. However, the physical aspects of the filaments generated at standoff distances are influenced by various environmental and laser properties, including the repetition rate of the laser. In this study, we evaluate the role of the predecessor pulse on the properties of filaments by varying the repetition rate of the laser in the range of 10–1000 Hz and using acoustic and emission signatures to diagnose filament properties. Our results show that filaments are brighter at high repetition rates while they are elongated at low repetition rates. The repetition rate has minimal influence on the downstream edge of the filament generation, while the upstream edge becomes elongated. The shadowgram images showed that the turbulence generated by the predecessor pulse may influence the next pulse when the laser is operating at high repetition rates.

47 OTHER INSTRUMENTATION

Speech analyzer

A speech signal is analyzed by applying the signal to formant filters which derive first, second and third signals respectively representing the frequency of the speech waveform in the first, second and third formants. A first pulse train having approximately a pulse rate representing the average frequency of the first formant is derived; second and third pulse trains having pulse rates respectively representing zero crossings of the second and third formants are derived. The first formant pulse train is derived by establishing N signal level bands, where N is an integer at least equal to two. Adjacent ones of the signal bands have common boundaries, each of which is a predetermined percentage of the peak level of a complete cycle of the speech waveform.

Lokerson, D. C.

Surface Height and Sea Ice Freeboard of the Arctic Ocean from ICESat-2: Characteristics and Early Results

We present the first winter season of surface height and sea ice freeboards of the Arctic Ocean from the new ICESat-2 (IS-2) mission. The Advanced Topographic Laser Altimeter System (ATLAS) onboard has six photon-counting beams for surface profiling with a 10-kHz pulse-rate (inter-pulse distance ~0.7m) and footprints of ~17m. Geolocated heights assigned to individual photons scattered from the surface allow significant flexibility in the construction of height distributions used in surface finding. For IS-2 sea ice products, a fixed 150-photon aggregate is used to control height precision and obtain better along-track resolution over high reflectance surfaces. Quasi-specular returns in openings as narrow as ~27m, crucial for freeboard calculations, are resolved. The fixed photon aggregate results in unique variable along-track resolutions and non-uniform sampling (17m x 27m to 17m x 200m for the strong beams) of the surface. The six profiling beams – three pairs separated by 3.3 km with a strong and weak beam in each pair – provide correlated statistics at regional length scales for assessment of beam-to-beam retrieval consistency and accuracy. Analysis shows along-track height precisions of ~2cm, and agreement in the monthly freeboard distributions across the strong beams to 1-2cm. In this paper, we describe briefly the approaches used in surface height and freeboard retrievals from ATLAS photon clouds, and detail the key features of these along-track sea ice products, focusing on the first release of data collected over the Arctic Ocean, which spans the period between October 14, 2018 – the start of data collection – and the end of March 2019.

R Kwok

High Pulse Repetition Rate, Eye Safe, Visible Wavelength Lidar Systems: Design, Results and Potential

In 1993 the first of the eye safe visible wavelength lidar systems known now as Micro Pulse Lidar (MPL) became operational. Since that time there have been several dozen of these systems produced and applied for full time profiling of atmospheric cloud and aerosol structure. There is currently an observational network of MPL sites to support global climate research. In the course of application of these instruments there have been significant improvements in understanding, design and performance of the systems. There are addition potential and applications beyond current practice for the high repetition rate, eye safe designs. The MPL network and the current capability, design and future potential of MPL systems are described.

Spinhirne, James

Grain refinement control in gas-shielded arc welding of aluminum tubing

When sections are being welded, operator varies pulse rate of power supply and simultaneously monitors signal on oscilloscope until rate is found which produces maximum arc gas voltage. Remainder of welding is performed with power supply set at this pulse rate, producing desired maximum weld puddle agitation and fine uniform weld of grain structure.

Iceland, W. F.

Blood circulation under weightless conditions

Biomedical data obtained on men and animals during weightlessness conditions establish instabilities in pulse rate and blood circulation that smooth out in proportion to adaptation to the weightless condition. The unusual slowness of recovery of pulse rate to initial values after space flight stress is attributed to biological simulation of hormonal shifts and discharge of humoral substances into the blood that prevent a rapid recovery of some biological indicators to initial values.

Kasyan, I. I.

Cardiorespiratory responses to exercise in air and underwater.

Respiratory gas exchange, end-tidal gas tensions, alveolar ventilation, respiratory frequency, cardiac output, and pulse rate were measured in four healthy adult males at rest and during mild and moderate exercise in air at 18-22 C and underwater at 35.0-35.5 C. Immersion was associated with a 10% increase in pulse rate and cardiac output at all levels of exercise. There were no changes in end-tidal CO2 tension or alveolar ventilation. It is concluded that horizontal subjects breathing at eupneic pressures and working against mild and moderate loads in warm water show the same responses to exercise as in air.-

Denison, D. M.

Modeling Electro-Optic Frequency Comb Generation as a Pump Source for Quantum Communications

The Quantum Communications group at NASA GRC is focused on developing technologies and system architectures to enable future space-based quantum networks. High-repetition rate pulsed pump lasers are needed because the signal on the quantum channel cannot be amplified, hence entanglement generation rates can only be increased through high-rate pumping. Additionally, tunability in center frequency, pulse width, and repetition rate allows for a wider parameter space over which to optimize quantum channel frequency conversion efficiency, joint spectral engineering, and channel synchronization for high-fidelity entanglement swapping –a necessary stepping-stone towards quantum repeater development. One of the most flexible methods for high-repetition rate pulse generation is through spectral shaping–generating a frequency comb from a continuous-wave(CW)laser using electro-optic modulators (EOMs). As a result, this project focuses on analytically modeling and simulating the effects various EOMs such as phase and intensity modulators have on a CW source. Generating a tunable frequency comb as the pump source allows us to conveniently fine-tune the central frequency, repetition rate, and the spectral shape of our source to match the strict optimal parameters for any given entanglement source considered in the future. These models and simulations are to be used for comparison purposes for future experiments as well as for providing the Quantum Communications group a convenient tool to understand the effects of manipulating various parameters have on the outgoing frequency comb.

Electro-optic modulator

Effect of antigravity suit inflation on cardiovascular, PRA, and PVP responses in humans

The effects of lower body and abdominal pressure, produced by antigravity suit inflation, on blood pressure, pulse rate, fluid and electrolyte shift, plasma vasopressin and plasma renin activity in humans in upright postures were studied. Five men and two women stood upright for 3 hr with the suit being either inflated or uninflated. In the control tests, the suit was inflated only during the latter part of the trials. Monitoring was carried out with a sphygnomanometer, with sensors for pulse rates, and using a photometer and osmometer to measure blood serum characteristics. The tests confirmed earlier findings that the anti-g suit eliminates increases in plasma renin activity. Also, the headward redistribution of blood obtained in the tests commends the anti-g suit as an alternative to water immersion or bed rest for initial weightlessness studies.

Kravik, S. E.