Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PULSE RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

MICROCALORIMETER SPECTROSCOPY AT HIGH PULSE RATES: A MULTI-PULSE FITTING TECHNIQUE

Transition Edge Sensor microcalorimeters can measure X-ray and gamma-ray energies with very high energy resolution and high photon-collection efficiency. For this technology to reach its full potential in future X-ray observatories, each sensor must be able to measure hundreds or even thousands of photon energies per second. Current “optimal filtering” approaches to achieve the best possible energy resolution work only for photons that are well isolated in time, a requirement which is in direct conflict with the need for high-rate measurements. We describe a new analysis procedure to allow fitting for the pulse height of all photons even in the presence of heavy pulse pile-up. In the limit of isolated pulses, the technique reduces to standard optimal filtering with long records. We employ reasonable approximations to the noise covariance function in order to render this procedure computationally viable even for very long data records. The technique is employed to analyze X-ray emission spectra at 600 eV and 6 keV at rates up to 250 counts s{sup −1} in microcalorimeters having exponential signal decay times of approximately 1.2 ms.

79 ASTRONOMY AND ASTROPHYSICS↗

Cellular response to high pulse repetition rate nanosecond pulses varies with fluorescent marker identity

Nanosecond electric pulses (nsEP's) are a well-studied phenomena in biophysics that cause substantial alterations to cellular membrane dynamics, internal biochemistry, and cytoskeletal structure, and induce apoptotic and necrotic cell death. While several studies have attempted to measure the effects of multiple nanosecond pulses, the effect of pulse repetition rate (PRR) has received little attention, especially at frequencies greater than 100 Hz. In this study, uptake of Propidium Iodide, FM 1–43, and YO-PRO-1 fluorescent dyes in CHO-K1 cells was monitored across a wide range of PRRs (5 Hz–500 KHz) using a laser-scanning confocal microscope in order to better understand how high frequency repetition rates impact induced biophysical changes. We show that frequency trends depend on the identity of the dye under study, which could implicate transmembrane protein channels in the uptake response due to their chemical selectivity. Finally, YO-PRO-1 fluorescence was monitored in the presence of Gadolinium (Gd{sup 3+}), Ruthenium Red, and in calcium-free solution to elucidate a mechanism for its unique frequency trend. - Highlights: • Pulse repetition rate (PRR) is understudied in nanosecond electric pulsing. • 200 V pulses were applied to CHO-K1 cells from 5 Hz to 500 KHz. • Pulsing was repeated using a variety of fluorophores and imaging conditions. • The response is highly dependent on the fluorophore and the imaging conditions. • This may implicate protein channels in the nanoporation response.

60 APPLIED LIFE SCIENCES↗

Pulse rates recorded by digital film positioner

System converts detector pulse rates to photographs of binary scale indicator lights on continuously moving film. The system then scans the film and transfers the data to computer-compatible magnetic tape.

Glass, I. S.↗

Monitoring of ultraviolet pulse rate dependent photomechanical actuation in carbon nanotubes using fiber Bragg gratings

In this Letter, we present a non-contact method of controlling and monitoring photomechanical actuation in carbon nanotubes (CNT) by exposing it to ultra-violet radiation at different pulse rates (10 to 200 Hz). This is accomplished by imparting a reversible photo induced strain (5–330 με) on CNT coated fibre Bragg gratings; CNT undergoes an internal reversible structural change due to cyclic photon absorption that leads to the development of mechanical strain, which in turn allows reversible switching of the Bragg wavelength. The results also reveal an interesting pulse rate dependent rise and fall times of photomechanical actuation in CNT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Pulse-rate averaging circuit

Averaging circuit provides a secondary control signal during inoperative periods of an intermittent primary control system. It can also provide an average pulse rate over a fixed time interval, such as in a digital frequency meter.

Jessee, R. D.↗

The effects of pulse rate, power, width and coding on signal detectability

The effects on the signal detectability of varying the pulse repetition rate (PRF), peak pulse power (p(pk)) and pulse width (tau(p)) (tp) are examined. Both coded and uncoded pulses are considered. The following quantities are assumed to be constant; (1) antenna area, (z)echo reflectivity, (3) Doppler shift, (4) spectral width, (5) spectral resolution, (6) effective sampling rate, and (7) total incoherent spectral averagaing time. The detectability is computed for two types of targets.

Carter, D. A.↗

Dependence of diode sensitivity on the pulse rate of delivered radiation

Purpose: It has been reported that diode sensitivity decreases by as much as 2% when the average dose rate set at the accelerator console was decreased from 600 to 40 MU/min. No explanation was given for this effect in earlier publications. This work is a detailed investigation of this phenomenon: the change of diode sensitivity versus the rate of delivery of dose pulses in the milliseconds and seconds range. Methods: X-ray beams used in this work had nominal energies of 6 and 15 MV and were generated by linear accelerators. The average dose rate was varied from 25 to 600 MU/min, which corresponded to time between microsecond-long dose pulses of 60-2.7 ms, respectively. The dose-per-pulse, dpp, was changed by positioning the detector at different source-to-detector distance. A variety of diodes fabricated by a number of manufacturers were tested in this work. Also, diodes in three different MapCHECKs (Sun Nuclear, Melbourne, FL) were tested. Results: For all diodes tested, the diode sensitivity decreases as the average dose rate is decreased, which corresponds to an increase in the pulse period, the time between radiation pulses. A sensitivity decrease as large as 5% is observed for a 60-ms pulse period. The diode sensitivity versus the pulse period is modeled by an empirical exponential function. This function has a fitting parameter, t{sub eff}, defined as the effective lifetime. The values of t{sub eff} were found to be 1.0-14 s, among the various diodes. For all diodes tested, t{sub eff} decreases as the dpp decreases and is greater for 15 MV than for 6 MV x rays. The decrease in diode sensitivity after 20 s without radiation can be reversed by as few as 60 radiation pulses. Conclusions: A decrease in diode sensitivity occurs with a decrease in the average dose rate, which corresponds to an increase in the pulse period of radiation. The sensitivity decrease is modeled by an empirical exponential function that decreases with an effective lifetime, t{sub eff}, of 1.0-14 s. t{sub eff} varies widely for different diodes, dpp, and x-ray energy. It is hypothesized that the capture of excess minority carriers by charge traps, cause the observed decrease in diode sensitivity. Also, it is hypothesized that the slow reopening of these traps occurs in the hundreds of milliseconds to seconds range at ambient temperature and this underlies the slow decrease in the diode sensitivity. Calibration of a diode is best done at the average dose rate with which it will be used. This is easily accomplished for radiation deliveries in which the average dose rate is a constant. However, for a VMAT delivery the average dose rate is a variable. For measurements made under these conditions diodes can be calibrated with a median or average dose rate which splits the difference in diode sensitivity that is known to occur with changes in average dose rate.

60 APPLIED LIFE SCIENCES↗

Minimizing pattern effects in semiconductor lasers at high rate pulse modulation

This paper deals with analytical and experimental work related to modulation of a semiconductor laser used in high bit rate communication. The approach is based upon minimizing the charge storage effect by a proper choice of the area of the modulating pulses and the bias current. The concept of using additional current pulses to probe for variations in electron density between pulses is investigated. The primary limitation on bit rate is found to be the ability to generate laser drive pulses free of ringing or similar transients. This and the 300 ps pulsewidth, an experimental constraint, limit the bit rate to about 1 Gbit/s. However, by using this approach it appears that bit rates considerably higher than 2 Gbits/s could be reached with sufficiently accurate control of drive pulse shape. It is found that the laser bias and the current pulse area had to be controlled within 1 percent and 10 percent, respectively.

Torphammar, P.↗

High Repetition Rate Pulsed 2-Micron Laser Transmitter for Coherent CO2 DIAL Measurement

A high repetition rate, highly efficient, Q-switched 2-micron laser system as the transmitter of a coherent differential absorption lidar for CO2 measurement has been developed at NASA Langley Research Center. Such a laser transmitter is a master-slave laser system. The master laser operates in a single frequency, either on-line or off-line of a selected CO2 absorption line. The slave laser is a Q-switched ring-cavity Ho:YLF laser which is pumped by a Tm:fiber laser. The repetition rate can be adjusted from a few hundred Hz to 10 kHz. The injection seeding success rate is from 99.4% to 99.95%. For 1 kHz operation, the output pulse energy is 5.5mJ with the pulse length of approximately 50 ns. The optical-to-optical efficiency is 39% when the pump power is 14.5W. The measured standard deviation of the laser frequency jitter is about 3 MHz.

Singh, Uprendra N.↗

Investigations of DNA damage induction and repair resulting from cellular exposure to high dose-rate pulsed proton beams

Studies regarding the radiobiological effects of low dose radiation, microbeam irradiation services have been developed in the world and today laser acceleration of protons and heavy ions may be used in radiation therapy. The application of different facilities is essential for studying bystander effects and relating signalling phenomena in different cells or tissues. In particular the use of ion beams results advantageous in cancer radiotherapy compared to more commonly used X-rays, since the ability of ions in delivering lethal amount of doses into the target tumour avoiding or limiting damage to the contiguous healthy tissues. At the INFN-LNS in Catania, a multidisciplinary radiobiology group is strategically structured aimed to develop radiobiological research, finalised to therapeutic applications, compatible with the use of high dose laser-driven ion beams. The characteristic non-continuous dose rates with several orders of magnitude of laser-driven ion beams makes this facility very interesting in the cellular systems' response to ultra-high dose rates with non-conventional pulse time intervals cellular studies. Our group have projected to examine the effect of high dose laser-driven ion beams on two cellular types: foetal fibroblasts (normal control cells) and DU145 (prostate cancer cells), studying the modulation of some different bio-molecular parameters, in particular cell proliferation and viability, DNA damage, redox cellular status, morphological alterations of both the cytoskeleton components and some cell organelles and the possible presence of apoptotic or necrotic cell death. Our group performed preliminary experiments with high energy (60 MeV), dose rate of 10 Gy/min, doses of 1, 2, 3 Gy and LET 1 keV/μm on human foetal fibroblasts (control cells). We observed that cell viability was not influenced by the characteristics of the beam, the irradiation conditions or the analysis time. Conversely, DNA damage was present at time 0, immediately following irradiation in a dose-dependent manner. The analysis of repair capability showed that the cells irradiated with 1 and 2 Gy almost completely recovered from the damage, but not, however, 3 Gy treated cells in which DNA damage was not recovered. In addition, the results indicate the importance of the use of an appropriate control in radiobiological in vitro analysis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High pulse rate high resolution optical radar system

The system is composed of an optical cavity with a laser and a mode locking means to build up an optical pulse. An optical switch is also provided within the cavity to convert the polarization of the optical pulse generated within the cavity. The optical switch comprises an electro-optical crystal driven by a time delayed driver circuit which is triggered by a coincident signal made from an optical pulse signal and a gating pulse signal. The converted optical pulse strikes a polarization sensitive prism and is deflected out of the cavity toward the pending target in the form of a pulse containing most of the optical energy generated by the laser in the pulse build-up period. After striking the target, the reflected energy is picked up by a transceiver with the total travel time of the pulse being recorded.

Goss, W. C.↗

Cost‐Effective Layered Oxide – Olivine Blend Cathodes for High‐Rate Pulse Power Lithium‐Ion Batteries

Abstract Sustainability and supply‐chain concerns require lithium‐ion batteries (LIBs) free from critical minerals, such as nickel and cobalt. While recent advances provide encouraging signs that cobalt can be removed, the question remains how much Ni can be removed from Co‐free layered oxide cathodes before sacrificing critical performance metrics. This study highlights the effect of reducing Ni by benchmarking several Co‐free cathodes with decreasing Ni content. Keeping the energy density the same by increasing the charge voltage, cathodes below 80% Ni content exhibit worsened capacity fade due to increasing oxygen release and electrolyte decomposition. Charge transfer and diffusion kinetics are also hindered with increasing Mn content and exacerbated by resistive surface phases formed at high voltages, rendering lower‐Ni, Co‐free cathodes less competitive than high‐Ni cathodes for high energy and power applications. It is demonstrated blending layered oxide with olivine as an effective alternative to deliver energy density and cycling stability comparable to lower‐Ni cathodes with moderate charging voltages. Blending with 30 wt% olivine LiMn 0.5 Fe 0.5 PO 4 (LMFP) virtually eliminates the diffusion limitation of layered oxides at low state‐of‐charge, with enhanced pulse power characteristics rivaling the high‐Ni counterparts. Cathode blending can further reduce the overall Ni content and cost without the performance limitations of lower‐Ni, Co‐free cathodes.

Lee, Steven↗

High repetition-rate pulse shaping of a spectrally broadened Yb femtosecond laser

We demonstrate compression and shaping of few cycle pulses from a high average power ytterbium laser system. The pulses from a commercial 20 W, 100 kHz Yb laser system are spectrally broadened in two-stages using cascaded, gas-filled, stretched hollow-core fibers and then compressed and shaped in an acousto-optic modulator-based pulse-shaper. The pulse-shaper allows for compression, characterization, and shaping all in one system, producing ∼10 fs pulses with 30 μ J of energy.

Codere, Julia↗