Differential pressure gauge has fast response

Differential pressure gage with semiconductor type strain gage elements measures rapidly changing pressure. Output of the strain gage elements is a dc voltage that is directly proportional to the pressure difference being measured.

Weber, H. S.↗

Critical Assessment of Pressure Gauges for ITER

The density and flux of molecular species in ITER, largely dominated by the molecular form of the main plasma components and the He ash, is a valuable parameter of relevance not only for operation purposes but also for validating existing neutral particle models of direct implications in divertor performance. An accurate and spatially resolved monitoring of this parameter implies the proper selection of pressure gauges able to cope with the very unique and aggressive environment to be expected in a fusion reactor. To date, there is no standard gauge fulfilling all the requirements, which encompass high neutron and gamma fluxes, together with strong magnetic field and temperature excursions and dusty environment. In the present work, a review of the challenges to face in the measurement of neutral pressure in ITER, together with existing technologies and developments to be made in some of them for their application to the task is presented. Particular attention is paid to R and D needs of existing concepts with potential use in future designs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas Pressure Gauge Based on Alpha-Particle Induced Ion Currents

The use of ionization currents for measuring pressure was first demonstrated in the late 1940's. The early gauges operated at high voltages and used rather large ion sources. The ionization gauge is actually a densitometer that is sensitive to the temperature and pressure of the gas in the chamber. This report describes the use of low voltages and small ion sources in the development of a prototype.

transducers gas pressure gauge alpha particles ion↗

A pressure gauge based on gas density measurement from analysis of the thermal noise of an atomic force microscope cantilever

We describe a gas-density gauge based on the analysis of the thermally-driven fluctuations of an atomic force microscope (AFM) cantilever. The fluctuations are modeled as a ring-down of a simple harmonic oscillator, which allows fitting of the resonance frequency and damping of the cantilever, which in turn yields the gas density. The pressure is obtained from the density using the known equation of state. In the range 10-220 kPa, the pressure readings from the cantilever gauge deviate by an average of only about 5% from pressure readings on a commercial gauge. The theoretical description we use to determine the pressure from the cantilever motion is based upon the continuum hypothesis, which sets a minimum pressure for our analysis. It is anticipated that the cantilever gauge could be extended to measure lower pressures given a molecular theoretical description. Alternatively, the gauge could be calibrated for use in the non-continuum range. Our measurement technique is similar to previous AFM cantilever measurements, but the analysis produces improved accuracy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of radiation damage on ruby as a pressure gauge

This study tackles the question if ruby crystals, irradiated with energetic heavy ions, can still be used as reliable pressure sensors. The problem is linked to novel irradiation experiments, exposing pressurized samples to swift heavy-ion beams. In order to test and quantify a possible influence of radiation damage on the laser-induced fluorescence lines of ruby (Al{sub 2}O{sub 3}:Cr{sup 3+}), small crystals were exposed to different heavy ions (Xe, Au, and U) with kinetic energies of several giga-electron volt at ambient as well as high-pressure conditions. With increasing fluence (ions/cm{sup 2}), the R{sub 1} and R{sub 2} lines shift both to lower wavelengths which leads to an underestimation of the pressure. An empirical correction term {epsilon} is proposed to include the irradiation damage effect into the commonly employed ruby calibration scale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

The sodium chloride primary pressure gauge

The failure of a central force model for sodium chloride is discussed. It is noted that it does not closely satisfy the Cauchy conditions at low temperatures, and that it fails the central force requirement of the Love condition. The available shock data for sodium chloride and its analysis is examined, and two reasons why the Hugoniot transformation pressure is likely to be less than 231 kbar are discussed. The important (but unjustified) theoretical assumptions made in converting Hugoniot to isothermal data is discussed; it is noted that serious error can enter for very large pressures for a given material and that at such high pressures the isothermal data should thus be considered only semiquantitative even if the Hugoniot data itself is accurate. An alternate method of estimating the isothermal transformation pressure from the Hugoniot transformation pressure is used. This method is based on the temperature derivative of the transformation pressure. On this basis it is concluded that an upper bound for the isothermal transformation of NaCl (to a CsCl-type structure) at room temperature is 257 kbar; it is noted that the actual value may be considerably less than this.

Ruoff, A. L.↗

Development and evaluation of vacuum pressure gauge components from carbon and graphite

A prototype all carbon triode ultrahigh vacuum gage was fabricated and tested. The gage exhibited a sensitivity of 3.7 per torr for nitrogen and an X-ray background approximately 0.1 as large as would be expected of a metal gage of the same design. The gage made from these materials, showed good sensitivity and durability. A practical technique was developed for bonding carbon components together without metal fasteners. The bond is made with a cross-linked phenolic resin which is converted to vitreous carbon by a careful pyrolysis procedure. The resulting bonds are strong, electrically conductive, and can withstand repeated excursions to 2500 K in vacuum. Measurements of adsorption and outgassing characteristics of four refractory carbons have confirmed that such materials are suitable for use in ultrahigh vacuum and that some are superior refractory metals in man respects.

Benson, D. K.↗

Pressure Gauges Monitor Leakage Past Seals

Method devised to measure leakage of gas past each of two sets of primary and secondary seals into common volume from which aggregate flow measured. Although method applicable only to specific combination of flow configuration and thermal conditions, it serves as example of more general approach involving use of statistical analysis to extract additional information from measurements.

Smith, Steven A.↗

An Observational Test of Transition Region Lines as a Pressure Gauge

The objective of this research project was to use high resolution spectroscopic observations from the SUMER (Solar Ultraviolet Measurements of Emitted Radiation) instrument on SOHO (Solar and Heliospheric Observatory) to study the structure of the solar transition region. Our main focus in this grant was to study the variation in density and emission across the quiet Sun transition region.

Siegmund, Oswald H. W.↗

A Numerical Simulation of Transport Phenomena During the Horizontal Single Belt Casting Process Using an Inclined Feeding System

Horizontal single belt casting (HSBC) has great potential to replace current conventional continuous casting (CCC) processes for sheet metal production, by directly casting 3 to 1 mm sheet for the automobile industry. In the present paper, two-dimensional mathematical models were developed to study transport phenomena, for the case of an inclined wall feeding system for a liquid aluminum wrought alloy (AA6111). Based on the commercial software ANSYS FLUENT 14.5 and user-defined functions, a two-layer turbulence model was used to examine the fluid flow emanating from a slot nozzle set above a water-cooled, high-speed, steel belt. The Volume of Fluid (VOF) method was used to predict the shape of the melt-air interface. A transformed coordinate system (x′, y′) was established in order to analyze the fluid flow on the inclined wall of the feeding system. The total pressure gauge gradient (∂p{sub total}/∂x) was used to describe the behavior of the melt film inside the slot nozzle of the head box. The modeling results show that during the melt film falling process, the total gauge pressure varies within the slot nozzle, which can decrease the stability of the falling film. The first impingement between the falling film and the inclined refractory wall of the feeding system gives rise to a local oscillation, and this influences the stability of the melt film moving downwards. At the rear meniscus position between the inclined wall and the moving belt, there is a clear vibration of the air-melt interface, together with a recirculation zone. The weak vibration of the air-melt interface could be induced by the periodic variation of the melt-air interface. Moreover, the formation of tiny air pockets is predicted. Finally, on the inclined wall of the feeding system, a suitable length of the transition area is needed to avoid over-acceleration of the melt film due to the force of gravity.

36 MATERIALS SCIENCE↗

Evaluation of Select Heat and Pressure Measurement Gauges for Potential Use in the NRC/OECD High Energy Arc Fault (HEAF) Test Program

In an effort to improve the current state of the art in fire probabilistic risk assessment methodology, the U.S. Nuclear Regulatory Commission, Office of Regulatory Research, contracted Sandia National Laboratories (SNL) to conduct a series of scoping tests to identify thermal and mechanical probes that could be used to characterize the zone of influence (ZOI) during high energy arc fault (HEAF) testing. For the thermal evaluation, passive and active probes were exposed to HEAF-like heat fluxes for a period of 2 seconds at the SNL's National Solar Thermal Test Facility to determine their ability to survive and measure such an extreme environment. Thermal probes tested included temperature lacquers (passive), NANMAC thermocouples, directional flame thermometers, modified plate thermometers, infrared temperature sensors, and a Gardon heat flux gauge. Similarly, passive and active pressure probes were evaluated by exposing them to pressures resulting from various high-explosive detonations at the Sandia Terminal Ballistic Facility. Pressure probes included bikini pressure gauges (passive) and pressure transducers. Results from these tests provided good insight to determine which probes should be considered for use during future HEAF testing.