Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE GAUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Compression of single-crystal magnesium oxide to 118 GPa and a ruby pressure gauge for helium pressure media

The pressure-volume equation of state (EoS) of single-crystal MgO has been studied in diamond-anvil cells loaded with helium to 118 GPa and in a non-hydrostatic KCl pressure medium to 87 GPa using monochromatic synchrotron X-ray diffraction. A third-order Birch-Murnaghan fit to the non-hydrostatic P-V data (KCl medium) yields typical results for the initial volume, V{sub 0} = 74.698(7) {angstrom}{sup 3}, bulk modulus, K{sub T0} = 164(1) GPa, and pressure derivative, K' = 4.05(4), using the non-hydrostatic ruby pressure gauge of Mao et al. (1978). However, compression of MgO in helium yields V{sub 0} = 74.697(6) {angstrom}{sup 3}, K{sub T0} = 159.6(6) GPa, and K' = 3.74(3) using the quasi-hydrostatic ruby gauge of Mao et al. (1986). In helium, the fitted equation of state of MgO underdetermines the pressure by 8% at 100 GPa when compared with the primary MgO pressure scale of Zha et al. (2000), with K{sub T0} = 160.2 GPa and K' = 4.03. The results suggest that either the compression mechanism of MgO changes above 40 GPa (in helium), or the ruby pressure gauge requires adjsutment for the softer helium pressure medium. We propose a ruby pressure gauge for helium based on shift of the ruby-R{sub 1} fluorescence line ({Delta}{lambda}/{lambda}{sub 0}) and the primary MgO pressure scale, with P (GPa) = A/B{l_brace}[1 + ({Delta}{lambda}/{lambda}{sub 0})]B - 1{r_brace}, where A is fixed to 1904 GPa and B = 10.32(7).

36 MATERIALS SCIENCE↗

Wisconsin In Situ Penning (WISP) gauge: A versatile neutral pressure gauge to measure partial pressures in strong magnetic fields

A new type of in-vessel Penning gauge, the Wisconsin In Situ Penning (WISP) gauge, has been developed and successfully operated in the Wendelstein 7-X (W7-X) island divertor baffle and vacuum vessel. The capacity of the quantitative measurements of the neutral reservoir for light impurities, in particular, helium, is important for tokamaks as well as stellarator divertors in order to avoid fuel dilution and radiative energy loss. Penning gauges assisted by spectroscopy are a powerful tool to obtain the total neutral pressure as well as fractional neutral pressures of specific impurities. The WISP gauge is a miniaturized Penning gauge arrangement, which exploits the ambient magnetic field of magnetic confinement fusion experiments to establish the Penning discharge. Then, in situ spectroscopy is conducted to separate the fractional neutral pressures of hydrogen, helium, and possibly also other impurities. The WISP probe head was qualified using the magnetic field of the Magnetized Dusty Plasma Experiment at Auburn University between 0.25 T and 3.5 T [E. Thomas et al ., J. Plasma Phys. 81, 345810206 (2015)]. The in-depth quantitative evaluation for hydrogen and helium will be shown as well as an exploration of nitrogen, argon, and neon. A power law scaling between current I and pressure p, I = f (Gas,V) p n⁽Gas, B⁾ , was shown. The factor f is gas and anode potential dependent, while n is gas and magnetic field strength dependent. Pressure measurements from 0.1 mbar and down to 1 × 10 -5 mbar were achieved, demonstrating a reliable operating range for relevant pressure levels in the divertor and main vessel regions in current and future fusion devices, with a time resolution of up to 1 kHz. The lowest achievable pressure measurement increases with an increase in B and can be shifted with the anode potential V . At W7-X, the WISP probe head was mounted on an immersion tube setup that passes through the cryostat and places the probe head close to the plasma. Two probe heads were positioned in different divertor pump gaps, top and bottom, and one close to the plasma on the midplane in one module. The gauges were in situ calibrated together with the ASDEX pressure gauges [G. Haas and H.-S. Bosch, Vacuum 51, 39 (1998)]. Data were taken during the entire operation phase 1.2b, and measurements were coherent with other neutral gas pressure gauges. For the spectroscopic partial pressure measurements, channels of a spectroscopic detection system based on photo-multipliers, a so-called filterscope [R. J. Colchin et al ., Rev. Sci. Instrum. 74, 2068 (2003)], provided by the Oak Ridge National Lab were used.

47 OTHER INSTRUMENTATION↗

Thermistor Pressure Gauge Design

Thermistor pressure gauges are characterized by large pressure range, good accuracy and stability, fast measurement, insensitivity to over-pressure, negligible out-gassing, ease in cleaning, and physical and electrical simplicity and ruggedness. A number of excellent papers have been published describing these gauges. However, a detailed account of design procedure and characteristics for a specific gauge would eliminate much of the trial and error encountered in designing a gauge having prescribed range, sensitivity, and stability.

Flanick, A. P.↗

Behaviour of the ASDEX pressure gauge at high neutral gas pressure and applications for ITER

The ASDEX Pressure Gauge is, at present, the main candidate for in-vessel neutral pressure measurement in ITER. Although the APG output is found to saturate at around 15 Pa, below the ITER requirement of 20 Pa. We show, here, that with small modifications of the gauge geometry and potentials settings we can achieve satisfactory behaviour up to 30 Pa at 6 T.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas ion laser construction for electrically isolating the pressure gauge thereof

The valve and the pressure gauge of a gas ion laser were electrically insulated from the laser discharge path by connecting them in series with the cathode of the laser. The laser cathode can be grounded and preferably is a cold cathode although a hot cathode may be used instead. The cold cathode was provided with a central aperture to which was connected both the pressure gauge and the gas pressure reservoir through the valve. This will effectively prevent electric discharges from passing either to the pressure gauge or the valve which would otherwise destroy the pressure gauge.

Wood, C. E.↗

Selection and static calibration of the Marsh J1678 pressure gauge

During the experimental testing of the ultralight, it was determined that a pressure gauge would be required to monitor the simulated flight loads. After analyzing several factors, which are indicated in the discussion section of this report, the Marsh J1678 pressure gauge appeared to be the prominent candidate for the task. However, prior to the final selection, the Marsh pressure gauge was calibrated twice by two different techniques. As a result of the calibration, the Marsh gauge was selected as the appropriate measuring device during the structural testing of the ultralight. Although, there are commerical pressure gauges available on the market that would have proven to be more efficient and accurate. However, in order to obtain these characteristics in a gauge, one has to pay the price on the price tag, and this value is an exponential function of the degree of accuracy efficiency, precision, and many other features that may be designed into the gauge. After analyzing the extent of precision and accuracy that would be required, a more expensive gauge wouldn't have proven to be a financial benefit towards the outcome of the experiment.

Oxendine, Charles R.↗

Diamond as a high pressure gauge up to 2.7 Mbar

A pressure gauge is a key issue of any high pressure experiment in a diamond anvil cell (DAC). Here we present a method of in situ synthesis of microcrystals of diamond that can be further used as a pressure standard in the course of the same DAC experiment. Calibration curve of the Raman shift versus pressure is extended up to 270 GPa and experimental results are compared with those of ab initio calculations.

36 MATERIALS SCIENCE↗

Alpha-particle Gas Pressure Gauge

Described are preliminary results obtained on a novel gas pressure gauge that operates between 0.1 and 1000 mb. This gauge uses a 1- micron Ci alpha particle source to ionize the gas in a small chamber with an electric field imposed between anode and cathode electrodes that drives positive ions to the cathode where they are collected electronically. This gauge could make Martian pressure measurements.

gas pressure sensor micro-pressure gauge alpha-par↗

Improved fast response pressure gauge for shock reflection studies in ionized gases.

An improved design is presented for a fast response pressure gauge (0.1 microsec risetime) suitable for short duration measurements on the end wall of a shock tube. The design includes standard components to facilitate gauge construction, and it utilizes dual capacitive sensing elements together with a signal differencing scheme to permit use of the gauge in ionized gases. Pressure-time records obtained with the gauge are presented showing details of pressure profiles on the shock tube end wall for reflecting shock waves in ionized gases.

Hanson, R. K.↗

Ruby and Sm:YAG fluorescence pressure gauges up to 120 GPa and 700 K

Diamond anvil cell (DAC) technique relies on pressure determination based on use of pressure gauges. Fluorescence-based gauges, such as ruby and Sm doped yttrium aluminum garnet (Sm:YAG), are frequently used in the high pressure research. Here we present the results of DAC experiments which allowed extending calibration curves of the fluorescence frequency versus pressure up to 120 GPa at high temperatures up to 700 K for both for ruby and Sm:YAG. Cubic boron nitride was used as the reference gauge.

36 MATERIALS SCIENCE↗

Safety of hydrogen pressure gauges.

Study of the relative safety afforded an operator by various hydrogen-pressure gauge case designs. It is shown that assurance of personnel safety, should a failure occur, requires careful selection of available gauge designs, together with proper mounting. Specific gauge case features and mounting requirements are recommended.

Voth, R. O.↗