Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microwave cavity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Investigation of coherence of niobium-based resonators enabled by a fast-sealing microwave cavity

Resonators and qubits with a niobium (Nb) base metal layer achieve some of the highest coherence times in superconducting quantum devices. The performance of such devices is often limited by loss associated with two-level systems, which are found primarily at material surfaces and interfaces. The metal-air (MA) interface is a major contributor to device loss. In this work, we develop a fast-sealing microwave cavity that enables devices to be placed under vacuum within five minutes of oxide removal, thereby significantly reducing the MA interface loss compared to common device processing and packaging approaches. Using coplanar stripline resonators, we demonstrate that devices sealed in such a cavity exhibit internal quality factors exceeding one million at single-photon power. After re-exposure to air, the devices show downward resonance frequency shifts and quality factor degradations, quantitatively consistent with a model of Nb oxide regrowth. The fast-sealing microwave cavity provides a practical and consistent method to mitigate MA interface loss and sustain high coherence in Nb devices, and establishes a controlled platform for studying metal oxide regrowth kinetics and dielectric properties, the understanding of which is critical to achieving high coherence in superconducting quantum devices.

Zhang, C. [Waterloo U., IQC; Waterloo U.]↗

Microwave Cavity Clocks On Space Station

We describe the status of a microwave cavity clock experiment to perform improved tests of Local Position Invariance and Lorentz Invariance on the International Space Station in conjunction with atomic clocks. Significant improvements over present bounds are expected in both cases. The oscillators can also be used to enhance the performance of atomic clocks at short time scales for other experiments.

Lipa, J. a.↗

Residual loss due to magnetic flux trapping in niobium superconducting microwave cavities

One of the significant source of radio frequency loss in superconducting microwave cavities is the trapped residual magnetic field during the cooldown due to the incomplete Messier effect. The sensitivity of flux trapping depends on the distribution of impurities, network of dislocations and defects which pin vortices. Recent advancement in cavity processing techniques resulted in very high quality factors with impurity doping, however the rf loss related to the flux trapping increases. High quality factor in SRF cavities is not only limited to particle accelerators but also emerging as an application to quantum computing and quantum information science. In this presentation, we present the results of measurements of flux trapping sensitivity on several 1.3 GHz elliptical accelerating cavities with different grain size, impurity content and surface preparations.

Dhakal, P.↗

Broad frequency tuning of a Nb$_{3}$Sn superconducting microwave cavity for dark matter searches

We demonstrate a novel broad-frequency tuning mechanism for superconducting microwave cavities designed for dark matter searches. Using a Nb$_3$Sn-coated cigar-shaped cavity operating at approximately 9 GHz, we achieve continuous frequency tuning exceeding 1 GHz by mechanically separating the two cavity halves: a "tuning-by-opening" technique. Finite-element method simulations predict that radiative losses do not degrade the quality factor even for large openings, as a closed cavity with an intrinsic quality factor of $10^7$ maintains this value for apertures up to 9 mm, corresponding to a tuning range from 9.0 to 7.5 GHz. Experimental validation using both copper ring spacers and a continuous sliding mechanism confirms $Q_0$ values exceeding the dark matter quality factor across the entire explored frequency range, despite mechanical imperfections and film non-uniformities. This tuning approach avoids inserting elements into the resonant volume, making it particularly suitable for high-Q superconducting cavities in axion haloscope experiments and readily applicable to REBCO-based implementations capable of operating in multi-tesla magnetic fields.

Maiello, D. [Padua U.; INFN, Padua] (ORCID:0009000↗

Probabilistic Analysis of Long-Term Degradation of Microwave Cavity Flow Sensor

We are investigating a microwave resonant cavity transducer for flow sensing in the vessel of a high temperature fluid advanced reactor (AR), such as a molten salt cooled reactor (MSCR) or a sodium fast reactor (SFR). This transducer is a hollow metallic cylindrical cavity, with the flat wall of the cylinder flexible enough to undergo microscopic deflection due to dynamic fluid pressure. Membrane deflection leads to a shift in the resonant frequency, which can be detected with a spectrum analyzer. We have performed a proof-of-concept experiment of flow sensing with the transducer in liquid sodium at 340°C in impinging liquid jet geometry. The transducer remained in liquid sodium for 70 days. After removal, no structural damage was observed, and the expected transducer response was verified in a water test. Because long-term (multi-year) experimental tests of transducer resilience to harsh environment are not practical, we have developed a probabilistic model of creep to estimate transducer resilience to the harsh environment. The probabilistic model considers diffusion creep under the condition of high temperature and low stress, where the stress and temperature are allowed to be random variables with Gaussian distributions. Using the probabilistic model, we estimate inelastic membrane deflections due to creep for several temperature ranges. We conclude that for temperatures less than 650°C, creep has negligible long-term effect on the transducer performance. Since a yellowish residue was observed on the transducer surface after 70 days of immersion in liquid sodium, we have investigated possible evidence of corrosion. Chromium depletion is a typical indicator of the corrosion process in stainless steel. Scraping off a residue from the transducer and performing scanning electron microscopy (SEM) with energy dispersive analysis (EDS) did not find any chromium in the residue. Approximately 60% of the residue consisted of copper, which can be attributed to contamination of sodium due to powder residue from machining of copper and brass components of the transducer.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spatial electron density and electric field strength measurements in microwave cavity experiments

Measurements of electron density and electric field strength have been made in an argon plasma contained in a resonant microwave cavity at 2.45 GHz. Spatial measurements of electron density, n sub e, are correlated with fluorescence observations of the discharge. Measurements of n sub e were made with Stark broadening and compared with n sub 3 calculated from measured plasma conductivity. Additional measurements of n sub 3 as a function of pressure and in mixtures of argon and oxygen are presented for pressures from 10 Torr to 1 atm. Measurements in flowing gases and in static systems are presented. In addition, limitations of these measurements are identified.

Peters, M.↗

Spatial electron density and electric field strength measurements in microwave cavity experiments

Measurements of electron density and electric field strength have been made in an argon plasma contained in a resonant microwave cavity at 2.45 GHz. Spatial measurements of electron density, n sub e, are correlated with fluorescence observations of the discharge. Measurements of n sub e were made with Stark broadening and compared with n sub e calculated from measured plasma conductivity. Additional measurements of n sub e as a function of pressure and in mixtures of argon and oxygen are presented for pressures from 10 Torr to 1 atm. Measurements in flowing gases and in static systems are presented. In addition, limitations of these measurements are identified.

Peters, M.↗

Hydrogen density measurements using an open-ended microwave cavity.

The density measurement of liquid hydrogen and two-phase mixtures of liquid and gaseous hydrogen is considered. This paper describes a complete prototype system that uses an open-ended microwave cavity for making dynamic density measurements of flowing hydrogen in a transfer line. The theory of operation along with test results for both the single- and two-phase cases are presented and discussed.

Wenger, N. C.↗

Heating And Positioning In A Microwave Cavity

Two reports describe theoretical and experimental studies of microwave dielectrophoretic positioning of spherical sample of lossy dielectric material in microwave resonant cavity and heating of positioned sphere by electro-magnetic field. Studies part of continuing effort to develop techniques for containerless processing of materials in microgravity. Previous studies in this series described in "Microwave Dielectrophoretic Levitation in Microgravity" (NPO-18824).

Jackson, Henry W.↗

High frequency gravitational wave sensing with superconducting microwave cavities

A promising way to probe physics beyond the Standard Model is to search for gravitational wave (GW) signals at high frequencies where known astrophysical sources can not obscure the signal. Similar to the search for dark matter, microwave cavity resonators can be used to detect faint effects from GWs. We will report on the progress of our project to operate such a detector and highlight improvements we are planning in the future. This includes quantum enhancement techniques like vacuum squeezing which will allow future detectors to operate beyond the standard quantum limit.

Marconato, Giovanni [Hamburg U.]↗

Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

There has been a concerted effort to improve the microwave heating technique for processing materials at high temperature. Improved optimization of the energy transfer from a microwave source to the material being processed is required. A vibration technique is pre- sented to continuously maintain a mode resonance and impedance match between a constant frequency magnetron source and a resonant cavity.

microwave↗

Experimental performance of a microwave cavity plasma disk ion source

The detailed description and performance characteristics of a microwave ion source are presented. This ion source utilizes an internally tuned, single-mode (or selective multimode) cylindrical cavity applicator to focus and match microwave energy into a disk-shaped discharge zone. The combination of mode focus control and variable, internal cavity matching allows the efficient operation and beam extraction over a wide range of pressures, powers and gaseous inputs. Experimental measurements of ion beam current versus accelerating voltage and input microwave power in xenon and oxygen gas are presented. Ion source specific energy and mass utilization versus experimental variables are also determined. The experimental performance demonstrates the ability of this ion source to extract an ion beam with a well matched, stable, and continuous operation over a wide range of input gases, low pressures, and over input gas flow rates in excess of 100 to a few sccm. Double Langmuir probe measurements in xenon gas indicate high degrees of ionization, and electron and ion concentrations in excess of 100 critical densities in the microwave discharge zone. This ion source has many potential uses such as spacecraft electric propulsion, material ion beam processing, and neutral beam ion sources.

Root, J.↗

(abstract) Vibration Method for Tracking the Resonant Mode and Impedance of a Microwave Cavity

We have developed a vibration technique to continuously maintain mode resonance and impedance match between a constant frequency magnetron source and resonant cavity. This method uses a vibrating metal rod to modulate the volume of the cavity that is equivalent to modulating an adjustable plunger. A similar vibrating metal rod attached to a stub tuner modulates the waveguide volume between the source and cavity. A phase sensitive detection scheme determines the optimum position of the adjustable plunger and stub tuner. The improved power transfer during the heating of a 99.8% pure alumina rod was demonstrated using this new technique. Temperature-time and reflected power-time plotswill be presented for the cases of no tracking, impedance tracker only, mode tracker only, and simultaneous impedance and mode tracking. Internal melting of the alumina rod near 2000°C with both trackers on will also be discussed.

microwave↗

Uniform field in microwave cavities through the use of effective magnetic walls

Wire medium (WM) resonators have emerged as a promising realization for plasma haloscopes—devices designed to detect axions, a potential component of dark matter. Key factors influencing the detection probability include cavity volume, resonance quality factor, and form factor. While the form factor has been explored for resonant frequency tuning, its optimization for axion detection remains unexplored. Here, in this work, we present an approach to significantly enhancing the form factor of WM plasma haloscopes. By shifting the metal walls of the resonator by a quarter wavelength, we effectively convert an electric wall boundary condition into a magnetic wall one, allowing for an almost uniform mode. Theoretical analysis and numerical simulations confirm that this modification improves the electric field profile and boosts the form factor, while also slightly enhancing the quality factor. We validate these findings through experimental results from two prototype resonators: one with a standard geometry and another with a quarter-wave air gap between the WM and the walls. Additionally, our method provides a simple way to control the field profile within WM cavities, which can be explored for further applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗