Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MS software”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Preprocessing Tool for Enhanced Ion Mobility–Mass Spectrometry-Based Omics Workflows

The ability to improve the data quality of ion mobility–mass spectrometry (IM-MS) measurements is of great importance for enabling modular and efficient computational workflows and gaining better qualitative and quantitative insights from complex biological and environmental samples. We developed the PNNL PreProcessor, a standalone and user-friendly software housing various algorithmic implementations to generate new MS-files with enhanced signal quality and in the same instrument format. Different experimental approaches are supported for IM-MS based on Drift-Tube (DT) and Structures for Lossless Ion Manipulations (SLIM), including liquid chromatography (LC) and infusion analyses. The algorithms extend the dynamic range of the detection system, while reducing file sizes for faster and memory-efficient downstream processing. Specifically, multidimensional smoothing improves peak shapes of poorly defined low-abundance signals, and saturation repair reconstructs the intensity profile of high-abundance peaks from various analyte types. Further, other functionalities are data compression and interpolation, IM demultiplexing, noise filtering by low intensity threshold and spike removal, and exporting of acquisition metadata. Several advantages of the tool are illustrated, including an increase of 19.4% in lipid annotations and a two-times faster processing of LC-DT IM-MS data-independent acquisition spectra from a complex lipid extract of a standard human plasma sample. The software is freely available at https://omics.pnl.gov/software/pnnl-preprocessor.

59 BASIC BIOLOGICAL SCIENCES↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

Design and performance of AI agents interfacing with an atomic layer deposition tool

In this work, we introduce the design of an atomic layer deposition (ALD) reactor augmented with an AI interface for autonomous materials synthesis. Our modular design encapsulates the particularities of the hardware behind a Python interface that communicates with the ALD control software via transmission control protocol. This interface is compatible with model context protocol interfaces used in agentic frameworks. We have integrated our tool with a simple AI agent that leverages a large language model to transform user-supplied queries into ALD processes that are then run in our reactor. Our approach uses a JavaScript object notation schema to encode ALD processes. Our experimental results show that the AI interface does not impose a significant overhead to our control software, at least within our fastest 10 ms scale. We also carried out a detailed evaluation of the agent performance using leading models in two classes of tasks: basic instruction and process discovery tasks, where the agent is presented with a target material and needs to identify the correct ALD process compatible with the reactor configuration. Despite the simplicity of our agent design, we observed that most of the advanced models excelled at the instruction tasks. However, only recent models, such as o1, o3, GPT-5, and Claude Opus 4, performed well in process discovery tasks. We also observed significant variability in the response for the hardest challenges. While the results obtained are promising, we identify areas where AI research could improve the performance of agents for ALD.

47 OTHER INSTRUMENTATION↗

Workflow for High-throughput Screening of Enzyme Mutant Libraries Using Matrix-assisted Laser Desorption/Ionization Mass Spectrometry Analysis of Escherichia coli Colonies

High-throughput molecular screening of microbial colonies and DNA libraries are critical procedures that enable applications such as directed evolution, functional genomics, microbial identification, and creation of engineered microbial strains to produce high-value molecules. A promising chemical screening approach is the measurement of products directly from microbial colonies via optically guided matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Measuring the compounds from microbial colonies bypasses liquid culture with a screen that takes approximately 5 s per sample. We describe a protocol combining a dedicated informatics pipeline and sample preparation method that can prepare up to 3,000 colonies in under 3 h. The screening protocol starts from colonies grown on Petri dishes and then transferred onto MALDI plates via imprinting. The target plate with the colonies is imaged by a flatbed scanner and the colonies are located via custom software. The target plate is coated with MALDI matrix, MALDI-MS analyzes the colony locations, and data analysis enables the determination of colonies with the desired biochemical properties. This workflow screens thousands of colonies per day without requiring additional automation. The wide chemical coverage and the high sensitivity of MALDI-MS enable diverse screening projects such as modifying enzymes and functional genomics surveys of gene activation/inhibition libraries.

Choe, Kisurb↗

PSpecteR: A User-Friendly and Interactive Application for Visualizing Top-Down and Bottom-Up Proteomics Data in R

Visual examination of mass spectrometry data is necessary to assess data quality and to facilitate data exploration. Graphics provide the means to evaluate spectral properties, test alternative peptide/protein sequence matches, prepare annotated spectra for publication, and fine-tune parameters during wet lab procedures. Visual inspection of MS data is hindered by proprietary proteomics visualization software designed for particular workflows and academic software that lack visualization tools. We built PSpecteR, an open-source and interactive R Shiny web application to address these issues, with support for several steps of proteomics data processing, including: reading various mass spectrometry files, running open-source database search tools, labelling spectra with fragmentation patterns, testing post-translational modifications, plotting where identified fragments map to reference sequences, and visualizing algorithmic output and metadata. All figures, tables, and spectra are exportable within one easy-to-use graphical user interface. Our current software provides a flexible and modern R framework to support fast implementation of additional features. The open source code is readily available (https://github.com/EMSL-Computing/PSpecteR), and a PSpecteR Docker container (https://hub.docker.com/r/emslcomputing) is available for easy local installation.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

PeakQC: A Software Tool for Omics-Agnostic Automated Quality Control of Mass Spectrometry Data

Mass spectrometry is broadly employed to study complex molecular mechanisms in various biological and environmental fields, enabling 'omics' research such as proteomics, metabolomics, and lipidomics. As study cohorts grow larger and more complex with dozens to hundreds of samples, the need for robust quality control (QC) measures through automated software tools becomes paramount to ensure the integrity, high quality, and validity of scientific conclusions from downstream analyses and minimize the waste of resources. Since existing QC tools are mostly dedicated to proteomics, automated solutions supporting metabolomics are needed. To address this need, we developed the software PeakQC, a tool for automated QC of MS data that is independent of omics molecular types (i.e., omics-agnostic). It allows automated extraction and inspection of peak metrics of precursor ions (e.g., errors in mass, retention time, arrival time) and supports various instrumentations and acquisition types, from infusion experiments or using liquid chromatography and/or ion mobility spectrometry front-end separations and with/without fragmentation spectra from data-dependent or independent acquisition analyses. Diagnostic plots for fragmentation spectra are also generated. Here, in this paper, we describe and illustrate PeakQC’s functionalities using different representative data sets, demonstrating its utility as a valuable tool for enhancing the quality and reliability of omics mass spectrometry analyses.

47 OTHER INSTRUMENTATION↗

AutoCCS: automated collision cross-section calculation software for ion mobility spectrometry–mass spectrometry

Abstract Motivation Ion mobility spectrometry (IMS) separations are increasingly used in conjunction with mass spectrometry (MS) for separation and characterization of ionized molecular species. Information obtained from IMS measurements includes the ion’s collision cross section (CCS), which reflects its size and structure and constitutes a descriptor for distinguishing similar species in mixtures that cannot be separated using conventional approaches. Incorporating CCS into MS-based workflows can improve the specificity and confidence of molecular identification. At present, there is no automated, open-source pipeline for determining CCS of analyte ions in both targeted and untargeted fashion, and intensive user-assisted processing with vendor software and manual evaluation is often required. Results We present AutoCCS, an open-source software to rapidly determine CCS values from IMS-MS measurements. We conducted various IMS experiments in different formats to demonstrate the flexibility of AutoCCS for automated CCS calculation: (i) stepped-field methods for drift tube-based IMS (DTIMS), (ii) single-field methods for DTIMS (supporting two calibration methods: a standard and a new enhanced method) and (iii) linear calibration for Bruker timsTOF and non-linear calibration methods for traveling wave based-IMS in Waters Synapt and Structures for Lossless Ion Manipulations. We demonstrated that AutoCCS offers an accurate and reproducible determination of CCS for both standard and unknown analyte ions in various IMS-MS platforms, IMS-field methods, ionization modes and collision gases, without requiring manual processing. Availability and implementation https://github.com/PNNL-Comp-Mass-Spec/AutoCCS. Supplementary information Supplementary data are available at Bioinformatics online. Demo datasets are publicly available at MassIVE (Dataset ID: MSV000085979).

47 OTHER INSTRUMENTATION↗

Digitizing Curves from LA-10860 to be Used in CritView

This report documents the digitization of figures from LA-10860-MS in order to import the data into the CritView software application. The original figures were created by Los Alamos National Laboratory and the latest revision was released in 1986. All figures were digitized using Engauge Digitizer (ver. 12.1) .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating Software Tools for Lipid Identification from Ion Mobility Spectrometry–Mass Spectrometry Lipidomics Data

The unambiguous identification of lipids is a critical component of lipidomics studies and greatly impacts the interpretation and significance of analyses as well as the ultimate biological understandings derived from measurements. The level of structural detail that is available for lipid identifications is largely determined by the analytical platform being used. Mass spectrometry (MS) coupled with liquid chromatography (LC) is the predominant combination of analytical techniques used for lipidomics studies, and these methods can provide fairly detailed lipid identification. More recently, ion mobility spectrometry (IMS) has begun to see greater adoption in lipidomics studies thanks to the additional dimension of separation that it provides and the added structural information that can support lipid identification. At present, relatively few software tools are available for IMS-MS lipidomics data analysis, which reflects the still limited adoption of IMS as well as the limited software support. This fact is even more pronounced for isomer identifications, such as the determination of double bond positions or integration with MS-based imaging. In this review, we survey the landscape of software tools that are available for the analysis of IMS-MS-based lipidomics data and we evaluate lipid identifications produced by these tools using open-access data sourced from the peer-reviewed lipidomics literature.

59 BASIC BIOLOGICAL SCIENCES↗

Computational tools and algorithms for ion mobility spectrometry-mass spectrometry

Ion mobility spectrometry-mass spectrometry (IMS-MS or IM-MS) is a powerful analytical technique that combines the gas-phase separation capabilities of IM with the identification and quantification capabilities of MS. IM-MS can differentiate molecules with indistinguishable masses but different structures (e.g., isomers, isobars, molecular classes, and contaminant ions). The importance of this analytical technique is reflected by a staged increase in the number of applications for molecular characterization across a variety of fields, from different MS-based omics (proteomics, metabolomics, lipidomics, etc.) to the structural characterization of glycans, organic matter, proteins, and macromolecular complexes. With the increasing application of IM-MS there is a pressing need for effective and accessible computational tools. This article presents an overview of the most recent free and open-source software tools specifically tailored for the analysis and interpretation of data derived from IM-MS instrumentation. This review enumerates these tools and outlines their main algorithmic approaches, while highlighting representative applications across different fields. Finally, a discussion of current limitations and expectable improvements is presented.

59 BASIC BIOLOGICAL SCIENCES↗

EI_MS_ML

The unambiguous identification of compounds from their electron ionization mass (EI-MS) spectra remains a significant unsolved problem in the field of metabolomics and analytical chemistry as a whole. Typically EI-MS spectra are compared using various mathematical operations that convert the spectral similarity or differences into a distance-like metric that roughly approximates the similarity of any two spectra. A commonly used metric for this is the cosine similarity metric which has values close to one for very similar spectra and a value of zero for very dissimilar spectra; however, no metric is perfect. Due to the prevalence of structurally-similar compounds such as isomers and the prevalence of certain fragmentation patterns across structurally-dissimilar compounds, the unambiguous assignment of EI-MS spectra compounds remains difficult. Frequently, querying an observed EI-MS spectrum against a large database such as the NIST17 library yields multiple possible assignments requiring the end user to distinguish between multiple high scoring hits, or multiple low scoring hits while keeping in mind that the correct hit may not be in the database at all. Although techniques such as orthogonal information from techniques such as chromatography can greatly aid in unambiguous assignment, this also requires more complicated experimental designs and access to more complicated analytical instrumentation. Substructures can be trivially detected and represented as strings using a previously published technique called node coloring from a known chemical structure. However, for experimentally-derived EI-MS spectra this information must be derived from the spectra itself (i.e., because we do not know what compound it represents). To achieve this, the software uses techniques from the field of machine learning and a large training dataset of EI-MS spectra corresponding to known structures annotated with substructure strings, to build models that can predict the presence of a given chemical substructure from an EI-MS spectrum directly.If these predictions are of high-quality (i.e., are unlikely to be false positives), the presence of one or more predicted substructures can be used to constrain the number of possible hits for a query spectrum. Mathematically, this restriction could be expressed in many forms, but the most straight-forward implementation is to weight the cosine similarity of a query spectrum and a plausible database match with a Tanimoto-like coefficient based on the ratio of the number of substructures predicted to the number of substructures present in the potential database hit. Determining which combination of models best reduces assignment ambiguity will be achieved using a combination of manual curation and optimization techniques such as genetic algorithms. This software will perform all the steps necessary to construct said models from a training dataset and evaluate them using a holdout dataset. Various statistical analyses can be performed to determine if this approach does decrease assignment ambiguity. For example, if this approach works, on average, the rank-order of the correct assignment for the holdout set of EI-MS spectra should decrease and the weighted cosine similarities for most of the possible matches in the database should be better than the unweighted cosine similarities. Furthermore, this same pipeline can be used on real experimental data to generate less ambiguous assignments.

Mitchell, Joshua↗

Analysis of solid uranium particulates on cotton swipes with an automated microextraction-ICP-MS system

Here, an automated microextraction method coupled to an inductively coupled plasma – mass spectrometer (ICP-MS) was developed for the direct analysis of solid uranium particulates on the surface of cotton swipes. The microextraction probe extracts particulates from the sample surface, in a flowing solvent, and directs the removed analyte to an ICP-MS for isotopic determination. The automated system utilizes a mechanical XY stage that is software controlled with the capability of saving and returning to specific locations and a camera focused to the swipe surface for optimal viewing of the extracted locations (i.e., material present). Here, particulates (n = 135) were extracted and measured by ICP-MS, including 35 depleted uranyl nitrate hexahydrate (UN) (used for mass bias corrections), 50 uranyl fluoride (UO 2 F 2 ), and 50 uranyl acetate (UAc) particulates. Blank extractions were performed on the cotton swipes between triplicate sample analyses. Between each swipe extraction, the probe was sent between two wells containing 10% and 5% HNO 3 to clean the probe head and to eliminate any analyte carryover between particulates. The measured 235 U/ 238 U and 234 U/ 238 U isotope ratios for the UO 2 F 2 particulates were 0.00725(8) and 0.000054(4), a percent relative difference (% RD) of –0.041% and –1.7% from the reference isotope ratios determined in-lab through multi-collector ICP-MS analysis of dissolved aliquots of the U material. The UAc samples had a measured 235 U/ 238 U isotope ratio of 0.00206(7), a –0.96% relative difference from the reference value of 0.00208(1). The 234 U/ 238 U and 236 U/ 238 U isotope ratios were 0.000008(1) and 0.000031(4), –5.1% RD and –4.3% RD, respectively. The automated sample stage enabled seamless and rapid particle analysis, leading to a significant increase in throughput versus what was previously possible. Additionally, the saved location capability reduced user sampling error as sampling locations were easily stored and recalled. Analysis of U particles on the swipe surface – including blanks, mass bias, and triplicate extractions – was completed in less than an hour without any sample preparation necessary.

47 OTHER INSTRUMENTATION↗

Yeast Transformation on Hamilton Vantage (YT Vantage) v1

Our software program is designed for the Hamilton Vantage liquid handling robot, automating the Build step in the Design-Build-Test-Learn (DBTL) cycle for Saccharomyces cerevisiae. This program minimizes human intervention, enabling rapid identification of pathway bottlenecks and genes that enhance verazine production. The program takes competent yeast and plasmid DNA as input and generates an output library of engineered strains compatible with automated colony picking, high-throughput culturing, and chemical extraction for downstream LC-MS analysis. A user-friendly interface, developed using the Hamilton Method Editor software, allows for on-demand parameter customization. By automating this process, our program streamlines the construction of Saccharomyces cerevisiae, reducing manual labor and increasing efficiency. While the manual process is well-documented, integration with robotic automation is less common, making our program a valuable tool for researchers. With this software, we achieved 2-5 fold increases in verazine production, demonstrating its potential to accelerate research in this field.

Louie, Randy [Lawrence Berkeley National Laborator↗

Molecular Dynamics Simulation of Complex Reactivity with the Rapid Approach for Proton Transport and Other Reactions (RAPTOR) Software Package

Simulating chemically reactive phenomena such as proton transport on nanosecond to microsecond and beyond time scales is a challenging task. Ab initio methods are unable to currently access these time scales routinely, and traditional molecular dynamics methods feature fixed bonding arrangements that cannot account for changes in the system’s bonding topology. The Multiscale Reactive Molecular Dynamics (MS-RMD) method, as implemented in the Rapid Approach for Proton Transport and Other Reactions (RAPTOR) software package for the LAMMPS molecular dynamics code, offers a method to routinely sample longer time scale reactive simulation data with statistical precision. RAPTOR may also be interfaced with enhanced sampling methods to drive simulations toward the analysis of reactive rare events, and a number of collective variables (CVs) have been developed to facilitate this. Key advances to this methodology, including GPU acceleration efforts and novel CVs to model water wire formation are reviewed, along with recent applications of the method which demonstrate its versatility and robustness.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

metabCombiner 2.0: Disparate Multi-Dataset Feature Alignment for LC-MS Metabolomics

Liquid chromatography–high-resolution mass spectrometry (LC-HRMS), as applied to untargeted metabolomics, enables the simultaneous detection of thousands of small molecules, generating complex datasets. Alignment is a crucial step in data processing pipelines, whereby LC-MS features derived from common ions are assembled into a unified matrix amenable to further analysis. Variability in the analytical factors that influence liquid chromatography separations complicates data alignment. This is prominent when aligning data acquired in different laboratories, generated using non-identical instruments, or between batches from large-scale studies. Previously, we developed metabCombiner for aligning disparately acquired LC-MS metabolomics datasets. Here, we report significant upgrades to metabCombiner that enable the stepwise alignment of multiple untargeted LC-MS metabolomics datasets, facilitating inter-laboratory reproducibility studies. To accomplish this, a “primary” feature list is used as a template for matching compounds in “target” feature lists. We demonstrate this workflow by aligning four lipidomics datasets from core laboratories generated using each institution’s in-house LC-MS instrumentation and methods. We also introduce batchCombine, an application of the metabCombiner framework for aligning experiments composed of multiple batches. metabCombiner is available as an R package on Github and Bioconductor, along with a new online version implemented as an R Shiny App.

97 MATHEMATICS AND COMPUTING↗

MZA: A Data Conversion Tool to Facilitate Software Development and Artificial Intelligence Research in Multidimensional Mass Spectrometry

Modern mass spectrometry-based workflows employing hybrid instrumentation and orthogonal separations collect multidimensional data, potentially allowing deeper understanding in omics studies through adoption of artificial intelligence methods. However, the large volume of these rich data challenges existing data storage and access technologies, therefore precluding informatics advancements. Here we present MZA™ (pronounced m-za), the mass-to-charge (m/z) generic data storage and access tool designed to facilitate software development and artificial intelligence research in multidimensional mass spectrometry measurements. Composed by a data conversion tool and a simple file structure based on the HDF5 format, MZA provides easy, cross-platform and efficient programmatic access to raw MS-data, enabling fast development of new tools in data science programming languages such as Python and R. The software executable and example Python and R scripts are freely available at https://github.com/PNNL-m-q/mza.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗