Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Conversational high resolution mass spectrographic data reduction

A FORTRAN 4 program is described which reduces the data obtained from a high resolution mass spectrograph. The program (1) calculates an accurate mass for each line on the photoplate, and (2) assigns elemental compositions to each accurate mass. The program is intended for use in a time-shared computing environment and makes use of the conversational aspects of time-sharing operating systems.

Romiez, M. P.↗

An international laboratory comparison of dissolved organic matter composition by high resolution mass spectrometry: Are we getting the same answer?

Since the first detailed compositional analysis of dissolved organic matter (DOM) in 1995, high resolution mass spectrometry (HRMS) has become a vital tool for DOM characterization. While the upward trend in HRMS for molecular level analysis of DOM continues, so do the challenges of data comparison and interpretation between laboratories operating instruments of differing performance and user operating conditions. It is therefore essential that the community establishes whether data and trends can be compared robustly between research groups. To this end, 4 identically prepared DOM samples were each studied by 16 laboratories, representing 17 commercially-purchased instruments located across 8 countries, using positive- and negative-mode electrospray ionization (ESI) HRMS analysis. Despite the widely reported sensitivity of ESI experiments to sample matrix, preparation, ion source operation and instrument tuning parameters, the instruments used in this study showed relatively low variability between results for the same samples, particularly H/C and AI metrics. The variation in O/C and m/z metrics was relatively higher, although z-score graphs and %BCD demonstrated that the relative difference in general chemical composition between samples was the same for each instrument included in the study. As such, these metrics can be used for fingerprinting of DOM samples and as a benchmark for quality control in participating laboratories, with future strides in environmental science building upon these efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data Set Analysis to Reduce Uncertainty in Formula Assignments of Ultrahigh Resolution Mass Spectra

Environmental samples contain a vast array of organic compounds with diverse elemental compositions and heteroatom content. Molecular formula assignments of ultrahigh resolution mass spectra (HRMS) hold promise for elucidating the molecular composition of these compounds. However, the need to account for an assortment of heteroatoms increases the uncertainty associated with individual assignments – and ultimately the ecological, biological, and biogeochemical insights gleaned from the assignments. To address this challenge, we introduce a formula assignment strategy that leverages HRMS data sets to improve assignment confidence, filter false assignments, and mitigate bias in assignment routines. The strategy, implemented using CoreMS, first identifies the highest confidence assignment for a recurring ion in a data set by assessing the mass accuracy and isotopologue similarity of all assignments to the ion across the data set. The second component of the strategy examines the consistency of mass errors for an assigned ion throughout a data set and flags formulas with statistically unlikely deviations in mass error. Here, we illustrate the application and utility of the strategy by comparing its results against documented misassignment patterns within a set of oceanographic samples that were measured with 21 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Because the efficacy of our strategy improves with data set size, it is particularly useful for enhancing assignment confidence in large HRMS data sets common in studies of environmental systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computer programs for the interpretation of low resolution mass spectra: Program for calculation of molecular isotopic distribution and program for assignment of molecular formulas

Two FORTRAN computer programs for the interpretation of low resolution mass spectra were prepared and tested. One is for the calculation of the molecular isotopic distribution of any species from stored elemental distributions. The program requires only the input of the molecular formula and was designed for compatability with any computer system. The other program is for the determination of all possible combinations of atoms (and radicals) which may form an ion having a particular integer mass. It also uses a simplified input scheme and was designed for compatability with any system.

Miller, R. A.↗

Data and Scripts associated with “Lambda-PFLOTRAN: Workflow for Incorporating Organic Matter Chemistry Informed by Ultra High Resolution Mass Spectrometry into Biogeochemical Modeling.”

This data package is associated with the publication “Lambda-PFLOTRAN: Workflow for Incorporating Organic Matter Chemistry Informed by Ultra High Resolution Mass Spectrometry into Biogeochemical Modeling” submitted to Geoscientific Model Development (Muller et al., 2024). In this manuscript, organic matter chemistry and thermodynamics are directly connected to reactive transport simulators through the newly developed Lambda-PFLOTRAN (Parallel Reactive Flow and Transport model) workflow tool that succinctly incorporates organic matter chemistry data generated from Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) into reaction networks to simulate aerobic respiration of the organic matter and the resulting biogeochemistry. Lambda-PFLOTRAN is a python-based workflow, executed through a Jupyter Notebook interface, that digests raw FTICR-MS data, develops a representative reaction network based on substrate-explicit thermodynamic modeling (also termed lambda modeling due to its key thermodynamic parameter λ used therein), and completes a biogeochemical simulation with the open source, reactive flow, and transport code PFLOTRAN. This data package contains Jupyter Notebook based workflows for two test cases for running biogeochemical simulations of organic matter oxidation identified by FTICR-MS. It contains four primary folders (workflow, data, src, and analysis), a file-level metadata file (Muller_2024_Lambda_PFLOTRAN_Manuscript_Data_Package_flmd.csv) that lists all the files contained in this data package with a short description of each, and a data dictionary (Muller_2024_Lambda_PFLOTRAN_Manuscript_Data_Package_dd.csv) file that describes the tabular column headers. The ‘workflow’ folder contains the Jupyter Notebook based workflows for running the lambda analysis, PFLOTRAN simulation, sensitivity analysis and parameter estimation. The ‘data’ folder contains the FTICR-MS data, initial conditions, and incubation data for test cases 1 and 2 in folders titled ‘WHONDRS’ and ‘Colloids’, respectively. The data folder also has a ‘Database’ folder containing a reaction network for bulk organic matter (assumed to be CH2O) and a general database for PFLOTRAN (hanford_rxn_network). The CH2O reaction network defines bulk organic matter oxidation. Biogeochemical simulations are completed for both the lambda binned organic matter and bulk organic matter reaction networks. The ‘hanford_rxn_network’ database includes information required for PFLTORAN simulations including ion size, molar mass, and charge of the aqueous species, gases, and minerals phases. The ‘src’ folder contains python source codes for performing lambda analysis, PFLOTRAN simulation, sensitivity analysis and parameter estimation. The ‘analysis’ folder contains outputs from the test cases 1 and 2 including lambda analysis, PFLOTRAN runs and the calibration results.

54 ENVIRONMENTAL SCIENCES↗

Quantifying Phospholipids in Organic Samples Using a Hydrophilic Interaction Liquid Chromatography–Inductively Coupled Plasma High-Resolution Mass Spectrometry (HILIC-ICP-HRMS) Method

Here, in this study, a novel method using hydrophilic interaction liquid chromatography (HILIC) coupled with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was introduced for the quantification of phospholipids in oil samples. The method employed a bridged ethyl hybrid (BEH) stationary phase HILIC column with a tetrahydrofuran (THF)/water mobile phase, enhancing the solubility and detection of phospholipids. During the study, a gradient/matrix effect on ICP-HRMS sensitivity was observed and successfully compensated for experimentally, ensuring reliable quantification results. This approach has proven effective for a wide range of different oil samples including vegetable oils, animal fats, and phospholipid supplements. Notably, this method allowed the direct quantification of phospholipids in oil samples, bypassing the need for prior sample preparation methods, such as solid phase extraction (SPE), thereby streamlining the analytical process. The precision, accuracy, and reduced need for extensive sample preparation offered by this method mark a significant advancement in lipids analysis. Its robustness and broad applicability have substantial implications for industries such as food and renewable energy production, where both efficient and accurate lipid identification and quantification are crucial.

09 BIOMASS FUELS↗

Molecular Characterization of Organosulfate-Dominated Aerosols over Agricultural Fields from the Southern Great Plains by High-Resolution Mass Spectrometry

The molecular composition of organic aerosols, especially for day/nighttime variations of organosulfates above agricultural fields, is not well understood despite profound impacts on regional climate, crop production, air quality, and human health. Here, nanospray desorption electrospray ionization with high-resolution mass spectrometry (nano-DESI-HRMS) is used to interrogate the molecular composition of organic aerosols collected at the Southern Great Plains, located in an agricultural region of Oklahoma. Identified molecular formulae featured carbon, hydrogen, oxygen (CHO), nitrogen (CHNO), and/or sulfur (CHOS, CHNOS), with higher organosulfate proportions during daytime (41%) compared to nighttime (30%). In this work, nighttime aerosols featured increases in CHO, CHNO, and extremely low volatility organic carbon (ELVOC) species. However, due to high relative humidity, the nighttime aerosols phase state was found to be more liquid-like than daytime aerosols using parametrized glass transition temperatures. Aerosol molecular composition from an anthropogenically influenced plume (southerly winds) showed significant increases in CHOS and ELVOC species. By comparison with chamber studies, CHOS species are suspected to be of mixed biogenic and anthropogenic origin, whereas CHNOS species (not identified in the southerly winds) are suggested to predominately be of biogenic origin. Overall, this study provides key insight into organosulfates above agricultural fields, demonstrating dependence upon day/night cycles and episodic anthropogenic emissions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Use of Fisher's Ratio assisted multivariate curve resolution- alternating least squares for discovery-based analysis using ultrahigh pressure liquid chromatography-high resolution mass spectrometry

Non-targeted analysis of complex chemical mixtures can be difficult considering the convoluted nature of the matrix and the potential unknown chemical differences between samples or classes of samples. Ultrahigh pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) is an ideal technique to probe chemical differences for a wide variety of samples. While UHPLC-QTOF can discover minute chemical differences down to low part per billion (ppb) concentrations with a high degree of confidence, the application of high-resolution mass spectrometry can yield massive amounts of information (∼ 10 gb per sample) that cannot be analyzed manually. Therefore, the application of chemometric techniques is mandatory for the interrogation of complex samples. Fisher's ratio (FR) assisted multivariate curve resolution-alternating least squares (MCR-ALS) was used to the discover and identify the chemical differences between two classes of materials: 1) a pond water matrix and 2) the matrix spiked with a pharmaceutical standard mix containing 17 compounds. Thirteen of the seventeen spiked compounds were discovered using FR analysis, and then five were successfully deconvoluted using MCR-ALS wherein the number of curves chosen were automatically determined using singular value decomposition (SVD). In conclusion, the use of an automated FR assisted MCR-ALS will aid in discovering trace levels of chemical components without the need for the researcher to provide potentially biased input which will aid in non-targeted workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volatility Basis Set Distributions and Viscosity of Organic Aerosol Mixtures: Insights from Chemical Characterization Using Temperature-Programmed Desorption–Direct Analysis in Real-Time High-Resolution Mass Spectrometry

Quantitative assessment of gas-particle partitioning of individual components within complex atmospheric organic aerosols (OA) mixtures is critical for predicting and comprehending the formation and evolution of OA particles in the atmosphere. This investigation leverages previously documented data obtained through a temperature programmed desorption - direct analysis in real time – high resolution mass spectrometry (TPD-DART-HRMS) platform. This methodology facilitates the bottom-up construction of volatility basis set (VBS) distributions for constituents found in three biogenic secondary organic aerosol (SOA) mixtures produced through the ozonolysis of a-pinene, limonene, and ocimene. The apparent enthalpies (ΔH*, kJ mol -1 ) and saturated vapor mass concentrations (C T *, µg∙m -3 ) of individual SOA components, determined as a function of temperature (T, K), facilitated an assessment of changes in VBS distributions and gas-particle partitioning with respect to T and atmospheric total organic mass loadings (tOM, µg∙m -3 ). Further, the VBS distributions reveal distinct differences in volatilities among monomers, dimers, and trimers, enabling their categorization into separate volatility bins. At the ambient temperature of T = 298 K, only monomers efficiently partition between gas and particle phases across a broad range of atmospherically relevant total organic mass loadings (tOM) values of 1–100 µg∙m -3 . Partitioning of dimers and trimers becomes notable only at T > 360 K and T > 420 K, respectively. The viscosity of SOA mixtures is assessed using a bottom-up calculation approach, incorporating the input of elemental formulas, ΔH*, C T *, and particle-phase mass fractions of the SOA components. Through this approach, we are able to accurately estimate the variations in SOA viscosity that result from the evaporation of its components. These variations are, in turn, influenced by atmospherically relevant changes in tOM and T. Comparison of the calculated SOA viscosity and diffusivity values with literature reported experimental results shows close agreement, thereby validating the employed calculation approach. These findings underscore the significant potential for TPD-DART-HRMS measurements in enabling the untargeted analysis of organic molecules within OA mixtures. This approach facilitates quantitative assessment of their gas-particle partitioning and allows for the estimation of their viscosity and condensed-phase diffusion, thereby contributing valuable insights to atmospheric models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iterative and function-continuation Fourier deconvolution methods for enhancing mass spectrometer resolution

Mass spectrometer data in the form of ion current versus mass-to-charge ratio often include overlapping mass peaks, especially in low- and medium-resolution instruments. Numerical deconvolution of such data effectively enhances the resolution by decreasing the overlap of mass peaks. In this paper two approaches to deconvolution are presented: a function-domain iterative technique and a Fourier transform method which uses transform-domain function-continuation. Both techniques include data smoothing to reduce the sensitivity of the deconvolution to noise. The efficacy of these methods is demonstrated through application to representative mass spectrometer data and the deconvolved results are discussed and compared to data obtained from a spectrometer with sufficient resolution to achieve separation of the mass peaks studied. A case for which the deconvolution is seriously affected by Gibbs oscillations is analyzed.

Ioup, J. W.↗

Tethered balloon system and High-Resolution Mass Spectrometry Reveal Increased Organonitrates Aloft Compared to the Ground Level

Atmospheric particles play critical roles in climate. However, significant knowledge gaps remain regarding the vertically resolved organic molecular-level composition of atmospheric particles due to aloft sampling challenges. To address this, we use a tethered balloon system at the Southern Great Plains Observatory and high-resolution mass spectrometry to, respectively, collect and characterize organic molecular formulas (MF) in the ground level and aloft (up to 750 m) samples. We show that organic MF uniquely detected aloft were dominated by organonitrates (139 MF; 54% of all uniquely detected aloft MF). Organonitrates that were uniquely detected aloft featured elevated O/C ratios (0.73 ± 0.23) compared to aloft organonitrates that were commonly observed at the ground level (0.63 ± 0.22). Unique aloft organic molecular composition was positively associated with increased cloud coverage, increased aloft relative humidity (~40% increase compared to ground level), and decreased vertical wind variance. Furthermore, 29% of extremely low volatility organic compounds in the aloft sample were truly unique to the aloft sample compared to the ground level, emphasizing potential oligomer formation at higher altitudes. Overall, this study highlights the importance of considering vertically resolved organic molecular composition (particularly for organonitrates) and hypothesizes that aqueous phase transformations and vertical wind variance may be key variables affecting the molecular composition of aloft organic aerosol.

54 ENVIRONMENTAL SCIENCES↗

Background contamination by coplanar polychlorinated biphenyls (PCBs) in trace level high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) analytical procedures

The addition of the "dioxin-like" polychlorinated biphenyl (PCB) congeners to the assessment of risk associated with the 2,3,7,8-chlorine substituted dioxins and furans has dramatically increased the number of laboratories worldwide that are developing analytical procedures for their detection and quantitation. Most of these procedures are based on established sample preparation and analytical techniques employing high resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS), which are used for the analyses of dioxin/furans at low parts-per-trillion (ppt) levels. A significant and widespread problem that arises when using these sample preparation procedures for the analysis of coplanar PCBs is the presence of background levels of these congeners. Industrial processes, urban incineration, leaking electrical transformers, hazardous waste accidents, and improper waste disposal practices have released appreciable quantities of PCBs into the environment. This contamination has resulted in the global distribution of these compounds via the atmosphere and their ubiquitous presence in ambient air. The background presence of these compounds in method blanks must be addressed when determining the exact concentrations of these and other congeners in environmental samples. In this study reliable procedures were developed to accurately define these background levels and assess their variability over the course of the study. The background subtraction procedures developed and employed increase the probability that the values reported accurately represent the concentrations found in the samples and were not biased due to this background contamination.

Polychlorinated Biphenyls/analysis/metabolism↗

Phosphorus speciation analysis of fatty-acid-based feedstocks and fast pyrolysis biocrudes via gel permeation chromatography inductively coupled plasma high-resolution mass spectrometry

Renewable feedstocks, such as lignocelulosic fast pyrolysis oils and both vegetable oil and animal fats, are becoming a viable alternative to petroleum for producing high-quality renewable transportation fuels. However, the presence of phosphorus-containing compounds, mainly from phospholipids, in these renewable feedstocks is known to poison and deactivate hydrotreating catalysts during fuel production. In this work, gel permeation chromatography (GPC) combined with inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) was used to analyze feedstocks including unprocessed soybean oil, animal fat, and pyrolysis oils from red oak and milorganite to identify phosphorus species. The results have shown the presence of a wide range of different phosphorous compounds among all the samples analysed in this work. The GPC-ICP-HRMS analyses of a vegetable oil and two animal fats have shown different fingerprints based on the molecular weight of each of the samples, highlighting the structural differences among their corresponding phosphorus-containing compounds. While the presence of low-molecular-weight species, such as phospholipids, was expected, several high-molecular-weight species (MW > 10 000 Da) have been found, suggesting that high-molecular-weight micelles or liposomes might have been formed due to the high concentration of phospholipids in these samples. Results obtained through the hydroxylation of a mix of phospholipids (asolectin) and its posterior GPC-ICP-HRMS agree with this hypothesis. With respect to the lignocellulosic catalytic fast pyrolysis oil samples, the GPC-ICP-HRMS results obtained suggest that either aggregation or polymerization reactions might have occurred during the pyrolysis process, yielding phosphorus-containing compounds with an approximate molecular weight above 91 000 kDa. In addition, an aggregation phenomenom has been observed for those phosphorus species present within the fast pyrolysis oils after being stored for 3 months, especially for those pyrolysis oils contaning pre-processed feedstocks, such as milorganite.

09 BIOMASS FUELS↗