Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Analysis of an irradiated uranium sample for source attribution without chemical separation using microplasma ionization and ultrahigh resolution mass spectrometry

The use of element isotope ratios has great potential in not only determining the reactor type used to produce plutonium (Pu) but also in determining the burnup and the time since irradiation. While a powerful nuclear forensic technique, determining element isotope ratios is complicated by severe isobaric interferences when performed on typical inductively coupled plasma mass spectrometers. Such analyses require extensive chemical separations prior to analysis to alleviate the inter-elemental isobars. Ultrahigh mass resolution spectrometry provides a potential alternative, greatly reducing the complexity of sample preparation and turnaround times for these critical measurements. To demonstrate the power of the approach, a sample of irradiated, depleted uranium was analyzed with the liquid sampling—atmospheric pressure glow discharge ion source coupled to an Orbitrap mass spectrometer. The Orbitrap is augmented with an external data acquisition system, Spectroswiss’s FTMS-Booster X2T, allowing collection of extended ion transients, providing higher mass resolution. In using this approach, the 150 Sm/ 149 Sm and 152 Sm/ 149 Sm isotope ratios were found to be within 20% of predicted values without any chemical separations and without mass bias corrections. In addition, the 240 Pu/ 239 Pu isotope ratio was determined, free from the 238 UH + interferences common to the ICP-MS platforms, while at the same time allowing for the determination of U isotopic signatures. While these demonstrative results are from a single sample, the advantages of the microplasma/ultrahigh mass resolution approach to intra-element isotope ratio determinations are clear.

Fuel burnup↗

Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling

Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.

Biogenic volatile organic compounds↗

Annotation of DOM metabolomes with an ultrahigh resolution mass spectrometry molecular formula library

Current approaches to analyzing metabolomic data often rely on matching MS/MS fragmentation data to sparse libraries or databases. This approach results in limited identification of features, often with less than 10% of the dataset being annotated. A complementary approach is to assign molecular formula to features based on accurate mass measurements, but the platforms commonly used for metabolomics do not have the needed accuracy or resolving power to do this robustly, particularly for larger molecules. Using our newly modified analysis tool, CoreMS, we generated a library of molecular formula from pooled samples analyzed with LC-21T FT-ICR MS. This library successfully annotated approximately 53.2% of features identified from the exometabolome of marine diatom Phaeodactylum tricornutum – a nearly ten-fold increase over the 5.9% annotation rate achieved using a conventional MS/MS library matching approach. Using this FT-ICR MS library approach, we were able to differentiate differences in the exometabolome of P. tricornutum in iron replete and iron limited conditions, with 668 metabolites being differentially expressed (p < 0.05, 2 x intensity difference) under these conditions. The traditional MS/MS fragmentation-based annotation approach only annotated 61 of these metabolites, while our novel pipeline annotated 450 metabolites and revealed 12 metabolites that were significantly more abundant under low iron conditions. Our results demonstrate the utility of ultrahigh resolution mass spectrometry for generating more comprehensive and confident molecular annotations.

21T-FTICR-MS, CoreMS↗

High mass resolution, high angular acceptance time-of-flight mass spectroscopy for planetary missions under the Planetary Instrument Definition and Development Program (PIDDP)

This final report covers three years and several phases of work in which instrumentation for the Planetary Instrument Definition and Development Program (PIDDP) were successfully developed. There were two main thrusts to this research: (1) to develop and test methods for electrostatically scanning detector field-of-views, and (2) to improve the mass resolution of plasma mass spectrometers to M/delta M approximately 25, their field-of-view (FOV) to 360 degrees, and their E-range to cover approximately 1 eV to 50 keV. Prototypes of two different approaches to electrostatic scanning were built and tested. The Isochronous time-of-flight (TOF) and the linear electric field 3D TOF devices were examined.

Young, David T.↗

Could Microplasma Ionization and Ultrahigh Mass Resolution Alleviate Chemical Separations for Elemental and Isotopic Analysis?

At the extremes, all analytical spectrometric measurements are limited by the resolution of the spectrometer system. Spectral overlaps, isobars in the case of mass spectrometry, can lead to the implementation of complex and time-consuming chemical separations to alleviate those interferences. In the area of elemental/isotopic mass spectrometry, use of sector-field instruments can provide a mass resolution of ~10,000, but still necessitate chemical separations. Described here is the coupling of the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to ultra-high resolution Orbitrap mass analyzer systems to yield mass resolution values ranging from 70k to 1M. Resolution of this order, with commensurate improvements in precision and accuracy, holds the promise to affect elemental/isotopic determinations without the need for chemical separations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The use of gas chromatography – high resolution mass spectrometry for suspect screening and non-targeted analysis of per- and polyfluoroalkyl substances

This study is a workflow development for the analysis, identification, and categorization of per- and polyfluoroalkyl substances (PFAS) using gas chromatography-high resolution mass spectrometry (GC-HRMS) with non-targeted analysis (NTA) and suspect screening techniques. The behavior of various PFAS in a GC-HRMS was studied with regards to retention indices, ionization susceptibility, fragmentation patterns, etc. A custom PFAS database was constructed from 141 diverse PFAS. The database contains mass spectra from electron ionization (EI) mode, as well as MS and MS/MS spectra from positive and negative chemical ionization (PCI and NCI, respectively) modes. Common fragments of PFAS were identified across a diverse set of 141 PFAS analyzed. A workflow for suspect screening of PFAS and partially fluorinated products of incomplete combustion/destruction (PICs/PIDs) was developed which utilized both the custom PFAS database and external databases. PFAS and other fluorinated compounds were identified in both a challenge sample (designed to test the identification workflow) and incineration samples suspected to contain PFAS and fluorinated PICs/PIDs. The challenge sample resulted in a 100% true positive rate (TPR) for PFAS which were present in the custom PFAS database. In conclusion, several fluorinated species were tentatively identified in the incineration samples using the developed workflow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗