Engineering PapersSearch

SEARCH · Engineering Papers

Results for “MASER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Radiative instabilities and 1000 second fluctuations in astrophysical masers

A stability analysis for small (linear) perturbations is presented for the radiation in astrophysical masers treated in the usual, linear maser approximation. Instabilities that oscillate with a period of about L/c, where L is the length of the maser are found. They occur (1) when the maser is partly but not heavily saturated, (2) when the decay rate Gamma for the molecular states is near c/L, and (3) when the product of the brightness temperature T sub 0 of the incident radiation and the angle for the beaming is less than a critical value that depends upon the particular masing transition. A fourth parameter, the fractional inversion in the pumping multiplied by (T sub 0/frequency), determines the importance of spontaneous emission which can eliminate the instabilities. These instabilities are a likely cause for the fluctuations in the radiation from the 18 cm OH masers that have been reported to occur on time scales as short as 1000 s. The calculations are applicable to other types of astrophysical masers as well, and suggest that spontaneous emission will prevent similar instabilities in the H2O and SiO masers.

Scappaticci, Gerardo A.

Relaxation of molecular velocities and spectral line profiles of astrophysical masers

The rates at which the velocities of water molecules relax to a Maxwellian distribution are calculated under conditions that are representative of those in astrophysical water masers. Populations are calculated as a function of velocity for the lowest 40 rotational energy levels of ortho-water in order to make a detailed determination of the velocity relaxation rate. Relaxation rates for the 22 GHz maser at H2 densities of 10 exp 9/cu cm are 2.0/s and 5.1/s for temperatures of 400 K and 1000 K, respectively. Under these and other conditions, as well as for other maser transitions, the relaxation rate far exceeds the loss rate - usually by more than a factor of 10. Thus maser lines can remain narrow up to intensities that are at least a factor of 10 greater than the saturation intensity, and to path lengths that are at least a factor of 10 greater than the path length at which saturation occurs. Relaxation is dominated by the effects of trapped infrared radiation, though elastic and inelastic collisions are also included in the calculations. These relaxation rates, together with the observed line breadths of the 22 GHz masers, provide limits on maser luminosities which indicate that the brightest 22 GHz masers are highly beamed, with solid angles smaller than 10 exp -5 to 10 exp -4 Sr.

Anderson, Nels

Intensity-dependent circular polarization and circumstellar magnetic fields from the observation of SiO masers

A new aspect of the propagation of astrophysical maser radiation in the presence of a magnetic field is described in which circular polarization is created. The resulting antisymmetric spectral line profile for this circular polarization resembles that produced by the ordinary Zeeman effect when the Zeeman splittings are much less than the spectral line breadth. It is caused by the change, with increasing maser intensity, in the axis of symmetry for the molecular quantum states from a direction that is parallel to the magnetic field to a direction that is parallel to the direction of propagation. When the maser is radiatively saturated, and the rate for stimulated emission is within an order of magnitude of the Zeeman splitting in frequency units, this 'intensity-dependent circular polarization' is greater than that due to the ordinary Zeeman effect by factors as large as 1000. The circular polarization that is observed in the spectra of circumstellar SiO (J = 1-0) masers associated with late-type giants and supergiants may then be caused by magnetic fields as weak as about 10 mG. With the standard Zeeman interpretation of the observations, magnetic fields of 10-100 G are indicated. The lower fields are similar to the limits obtained from the observation of the 22 GHz water masers which are typically somewhat further from the central star. The observed tendency for the fractional linear polarization of SiO masers to increase with increasing angular momentum of the molecular state is shown to be a likely result of anisotropic pumping. Errors are identified that invalidate a recent conflicting claim in the literature about the basic theory of maser polarization in the regime that is relevant here.

Nedoluha, Gerald E.

Shock-excited NH3 (3, 3) masers in the NGC 6334 star-forming region

We report the discovery of four NH3 (3, 3) masers in the NGC 6334 star formation region. The masers are found in two of the seven far-infrared continuum sources where high-mass star formation is taking place in this molecular cloud. These masers occur at the ends of high-velocity molecular outflows; no maser emission was found near regions without high-velocity outflows. The NH3 masers are not associated with any other type of maser. These results confirm that the NH3 (3, 3) masers are caused by shocks and probably mark the location where the molecular outflow jet impinges upon the ambient medium.

Kraemer, Kathleen E.

Instabilities and the transport of polarized astrophysical maser radiation

Time-dependent, radiative instabilities in the creation and transport of polarized astrophysical maser radiation in the presence of a magnetic field are calculated. The instabilities are similar to and occur under the same conditions as those found previously by Scappaticci & Watson for unpolarized maser radiation. The common limits in which the Zeeman splitting is much greater than, and much less than, the spectral line breadths are both considered in the current investigation. The resulting fluctuations in the emergent radiation are potentially relevant for the OH 1665 MHz masers which have been reported to fluctuate on timescales of 1000 s and which tend to be polarized. Instabilities occur and alter the transport of maser radiation only under a quite limited range of conditions. In particular, we find here that the instabilities do not occur for conditions that are appropriate for astrophysical masers with small Zeeman splittings such as the SiO and H2O masers. The time-independent, numerical solutions to the GKK equations of radiative transfer that have been obtained in previous investigations are thus essentially always valid except within a narrow range of conditions relevant for the OH masers.

Wallin, Bradley K.

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The cryogenic hydrogen maser (CHM) developed at the Smithsonian Astrophysical Observatory (SAO) was designed to be functionally similar to SAO room temperature hydrogen masers with appropriate modifications made for operation at cryogenic temperatures. A schematic of the SAO CHM is shown in Figure 1, and a description of this device and its operation follows. A beam of molecular hydrogen is dissociated into atoms at room temperature. The resultant beam of atomic hydrogen is then cooled, magnetically state selected, and focused into a quartz storage bulb centered inside of a microwave cavity resonant with the hydrogen hyperfine transition at 1420 MHz. The quartz storage bulb is coated with a superfluid He-4 film, and both the bulb and cavity are maintained near 0.5 K. The maser signal is coupled out inductively and carried to room temperature via semi-rigid coaxial cable. After passing through a room temperature isolator and preamp, the maser signal is detected with a low-noise heterodyne receiver as used in the room temperature SAO hydrogen masers. The maser temperature is lowered to 0.5 K using a recirculating He-3 refrigerator. This refrigerator consists of several cooling stages: a liquid nitrogen stage at 77 K, a liquid 4He bath at 4.2 K, a pumped He-4 pot at approximately 1.7 K, and the pumped, recirculating He-3 stage at 0.5 K. The atomic hydrogen beam, state selector, storage bulb and cavity are all connected inside a single, maser vacuum chamber (MVC). This space is pumped out from below by a turbo pump. Above the MVC, an inlet to the space allows for the input of flowing superfluid 4He film. External to the MVC is a second, outer vacuum chamber (OVC), maintained for operation of the cryostat and also pumped by a turbo pump. Inside the OVC, there is radiation shielding at 77 K and 1.7 K.

Walsworth, Ronald L.

Hydrogen maser frequency standard

The fundamental theoretical limitations of the maser, systematic processes that cause instability, and some aspects of recently designed masers are described. A design for field use that has evolved from the development of the space borne maser is presented. The performance of this type of maser is close to theoretical limits imposed by thermal noise. Further developments of smaller masers for space and terrestrial use and recent work on masers operating at low temperatures is also discussed.

Vessot, R. F. C.

Saturation and beaming in astrophysical masers

A 'four-stream' model system of equations that are closely analogous to the equations of radiative transfer in a maser spectral line and are amenable to numerical solution are constructed. This model is used to investigate radiative transfer in asymmetric maser clouds. Competition between different beams of radiation for available pump photons is important in both unsaturated and saturated masers. Consequently, the radiation from a typical cloud will be highly beamed, even if the maser is saturated, because the shape of a typical cloud is not symmetric. In addition, it is shown that analysis of maser emission lines formed in expanding envelopes does not reveal the degree of saturation of the maser.

Alcock, C.

A cloud collision model for water maser excitation

High-velocity collisions between small, dense, neutral clouds or between a dense cloud and a dense shell can provide the energy source required to excite H2O maser emission. The radiative precursor from the surface of the collisional shock front rapidly diffuses through the cloud, heating the dust grains but leaving the H2 molecules cool. Transient maser emission occurs as the conditions for the Goldreich and Kwan (1974) 'hot-dust cold-gas' maser pump scheme are realized locally within the cloud. In time, the local maser action quenches due to the heating of the H2 molecules by collisions against the grains. Although this model cannot explain the very long-lived steady maser features, it is quite successful in explaining a number of the observed properties of the high-velocity features in such sources as Orion, W51, and W49. In particular, it provides a natural explanation for the rapid time variations, the narrow line widths, juxtaposition of high- and low-velocity features, and the short lifetimes which are frequently observed for the so-called high-velocity maser 'bullets' thought to be accelerated by strong stellar winds.

Tarter, T. C.

Monitoring observations of selected SiO maser sources at 7 mm wavelength - 1977-1979

High-spectral-resolution SiO maser observations at 7 mm wavelength were made for 13 circumstellar objects and Ori A over a 34 month interval from January 1977 to November 1979. These data precede and adjoin the SiO monitoring data taken at 3 and 7 mm wavelengths by Lane (1982) and at 3 mm wavelengths by Nyman and Olofsson (1985) and thus provide an important link in the record of the temporal behavior of SiO masers over a period of several years. The time-averaged center of the weak SiO maser emission pedestal gives the stellar radial velocity. This reinforces the idea that the SiO maser emission pedestal is representative of the true structure of a stellar SiO maser, while the more visible and stronger, narrow SiO emission spikes represent chance coherences along the velocity range of the pedestal. Similarities between the SiO maser velocity patterns of VY CMa and Ori A may suggest similarities in their evolutionary stages.

Snyder, L. E.

Cavity-Modulation Autotuner For Hydrogen Maser

Cavity-modulation tuning system maintains resonance of hydrogen-maser cavity automatically, stabilizing maser frequency, without introducing undesirable frequency modulation. System tunes maser cavity rapidly by modulating one of physical characteristics of cavity affecting resonant frequency. Frequency-controlling components of tuning system placed at maser cavity, within maser vacuum. Thermal environment well controlled, and device insensitive to driving signal. Features contribute to stability of maser frequency.

Dick, G. J.

A 43GHz VLBI mapping of SiO maser emission associated with Orion-KL IRC-2

A milliarcsecond resolution spot map of the SiO maser emission associated with IRC-2 in Orion-KL is presented. The two dominant groups of spectral features, near V(LRS) = -6 and 16 km/s, were observed in the 43 GHz, v = 1 to 0 transition of SiO, using a Mark III VLBI system. The 74 km baseline ran from Haystack Observatory in Westford, Massachusetts to Five College Radio Astronomy Observatory (FCRAO) in New Salem, Massachusetts. Five distinct maser features were observed: -8.5 to -6.5 km/s; -5 to -1.5 km/s; 12 to 13.5 km/s; 16.5 to 19 km/s; and 20 to 21 km/s (stellar velocity = 5 km/s). The relative positions were established, from an analysis of fringe phases, to an accuracy of about 5 milliarcseconds. All the features lay within an area of radius 0.08 arcseconds or 6x10(14) cm, at a distance of 500 pc. Previous interferometric studies were only able to measure the gross separation between the red and the blue shifted groups. Our measurement of the separation between these two gropus is consistent with those of the previous studies, indicating the persistence of these two centers of activity. The absolute positions of the masers with respect to IRC-2 are only known to an accuracy of about 1 arcsecond. It is assumed that IRC-2 is centered between the red shifted and the blue shifted maser features. The relative placement of these two groups of maser features agrees with observations of thermal emission from SO, which traces the outflow on a much larger scale. The SiO masers trace the neutral outflow from IRC-2 on the smallest scale yet observed.

Greenhill, L. J.

Performance of Soviet and US hydrogen masers

The frequencies of Soviet- and U.S.-built hydrogen masers located at the Smithsonian Astrophysical Observatory and at the United States Naval Observatory (USNO) were compared with each other and, via Global Positioning System (GPS) common-view measurements, with three primary frequency-reference scales. The best masers were found to have fractional frequency stabilities as low as 6 times 10(exp -16) for averaging times of approximately 10(exp 4) s. Members of the USNO maser ensemble provided frequency prediction better than 1 times 10(exp 14) for periods up to a few weeks. The frequency residuals of these masers, after removal of frequency drift and rate of change of drift, had stabilities of a few parts in 10(exp -15), with serveral masers achieving residual stabilities well below 1 times 10(exp -15) for intervals from 10(exp 5)s to 2 times 10(exp 6)s. The fractional frequency drifts of the 13 masers studied, relative to the primary reference standards, ranged from -0.2 times 10(exp -15)/day to +9.6 times 10(exp -15)/day.

Uljanov, Adolph A.

First images of water vapor masers in the galaxy M33

The first successful VLBI observations of 10 extragalactic H2O masers in the M33 galaxy are reported. A spectral-line VLBI synthesis map is constructed, the first of any extragalactic H2O maser sources. The map has the lowest noise of any K-band spectral line VLBI map yet produced. The maser emission extends over about 300 milliarcseconds and is divided into 14 distinct spatial components, the strongest of which has a correlated flux density of about 0.7 Jy. The relative positions of some of these components are determined accurately enough to provide first-epoch measurements for proper motion studies. The characteristics of the maser are similar to those of the most powerful maser in the Galaxy, W49N. A compact H II region is found close to the maser which is 1 pc in diameter and whose emission measure is about 6 x 10 to the 7th pc/cm exp 6. This region is the compact component of a more extended H II complex that extends over about 100 pc.

Greenhill, L. J.

Mid-infrared imaging of Orion BN/KL - Astrometry of IRc2 and the SiO maser

Array images of Orion BN/KL at nine midinfrared (5-20 microns) wavelengths have revealed a subarcsecond structure near IRc2 which provides new constraints on the relationship between IRc2 and the Orion SiO maser. The infrared source positions have been improved, and IRc2 is found to be displaced 0.8 +/- 0.2 arcsec (at least 400 AU) from the SiO maser, an order of magnitude greater than the separation assumed in the current maser model. The SiO maser and the IRc2 midinfrared source may be physically independent objects. There are indications that IRc2 is eroded on the south side adjacent to the SiO/H2O maser cluster, suggesting that another luminous object near IRc2, most likely a stellar object associated with radio continuum point source 'I', is the host for the Orion SiO maser.

Gezari, Daniel Y.

Molecular catastrophes and circumstellar SiO masers

Understanding the complex SiO maser regions of highly evolved stars can be improved through multiwavelength studies of 'premaser' stars, such as M0-M4 giants and semiregular variables, which can be placed on normal H-R diagrams unlike most of the OH-IR stars. I argue that SiO masers are a key part of the transformation of hot stellar plasma into cold circumstellar silicate dust, in the outflows from evolved, oxygen rich stars. Evidence for this statement rests on the following: (1) red giant mass loss originates in a stochastic, amsotropic manner; (2) SiO maser maps of Miras and red supergiants show numerous maser spots within a few stellar radii; (3) molecules and dust naturally form in a cooling outflow; (4) the IRAS Low Resolution Spectrometer provided evidence for diverse and variable 10 micron silicate features in Miras, and these shapes correlate well with the proposed maser chronology, suggesting a formation and annealing sequence. The theory for the occurrence of SiO masers involving thermal instability, related 'new' physics, recent calculations and a prediction are discussed.

Stencel, Robert E.

Hydrogen masers and cesium fountains at NRC

The NRC masers H-3 and H-4 have been operating since June 1993 with cavity servo control. These low-flux active H masers are showing stabilities of about 10(exp -15) from 1 hour to several days. Stability results are presented, and the current and planned uses of the masers are discussed. A cesium fountain primary frequency standard project has been started at NRC. Trapping and launching experiments with the goal of 7 m/s launches are beginning. We discuss our plans for a local oscillator and servo that exploit the pulsed aspect of cesium fountain standards, and meet the challenge of 10(exp -14) tau(exp -1/2) stability without requiring masers. At best, we expect to run this frequency standard initially for periods of hours each working day rather than continuously for years, and so frequency transfer to outside laboratories has been carefully considered. We conclude that masers (or other even better secondary clocks) are required to exploit this potential accuracy of the cesium fountain. We present and discuss our conclusion that it is feasible to transfer frequency in this way with a transfer-induced uncertainty of less than 10(exp -15), even in the presence of maser frequency drift and random walk noise.

Boulanger, J.-S.

Hydrogen maser clocks in space for solid-Earth research and time-transfer applications: Experiment overview and evaluation of Russian miniature sapphire loaded cavity

The Observatoire Cantonal de Neuchatel (ON) is developing for ESTEC a compact H-maser for space use based upon a miniature sapphire loaded microwave cavity, a technique pioneered at VNIIFTRI. Various contacts between West-European parties, headed by ESA, and the Russian parties, headed by ESA, led to the proposal for flying two H-masers on Meteor 3M, a Russian meteorology satellite in low polar orbit. The experiment will include two masers, one provided by ON and the other by VNIIFTRI. T/F transfer and precise positioning will be performed by both a microwave link, using PRARE equipment, and an optical link, using LASSO-like equipment. The main objectives of the experiment are precise orbit determination and point positioning for geodetic/geophysical research, ultra-accurate time comparison and dissemination as well as in-orbit demonstration of operation and performance of H-masers. Within the scope of a preliminary space H-maser development phase performed for ESTEC at ON in preparation to the joint experiment, a Russian miniature sapphire loaded microwave cavity, on loan from VNIIFTRI, was evaluated in a full-size EFOS hydrogen maser built by ON. The experimental evaluation confirmed the theoretical expectation that with a hydrogen storage volume of only 0.65 liter an atomic quality factor of 1.5 x 10(exp 9) can be obtained for a -105 dBm output power. This represents a theoretical Allan deviation of 1.7 x 10(exp -15) averaged on a 1000 s time interval. From a full-size design to a compact one, therefore, the sacrifice in performance due to the reduction of the storage volume is very small.

Busca, G.