Engineering PapersSearch

SEARCH · Engineering Papers

Results for “MASER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Interacting masers and the extreme brightness of astrophysical water masers

Extreme surface brightnesses have long been reported for water masers which are well beyond what is found in self-consistent, theoretical investigations of these masers. The transport of maser radiation is calculated when two masers, having the properties inferred for the numerous weaker masers and separated by distances characteristic of the molecular cloud, are aligned to within the angular spread of the beam of maser radiation. The beam size is reduced and brightness temperatures similar to the highest observed values are readily produced. This enhanced beaming reduces the number of photons required from each maser feature to a level that can be understood within available pumping scenarios. The large number of weaker masers that have been identified in the most luminous galactic cloud of water masers (the W49 region) makes it especially plausible that alignments occur and produce the very bright masers in this region.

Deguchi, Shuji

Detection of a weak maser emission pedestal associated with the SiO maser

Results are reported for high-spectral-resolution observations of the v = 1, J = 1-0 SiO maser sources at 43,122.027 MHz (6.95 mm wavelength) associated with the variable stars Omega Cet, NML Tau, VY CMa, R Leo, W Hya, VX Sgr, NML Cyg, and R Cas. A weak underlying maser emission pedestal is clearly observed in the spectra of all but NML Cyg and R Cas. The data indicate that the underlying pedestal of SiO emission appears to originate in a shell-like region around the star, has a thermal appearance even though it must be due to weak maser emission, and appears to be part of the spectral signature of SiO maser emission from late-type stars. It is found that the center velocities of the pedestals may be used to determine stellar radial velocities. Observations of large-scale time variations in the intensity of the Ori A SiO maser and the detection of weak maser pedestals associated with each of the two strong emission-feature groups in Orion are also discussed. It is suggested that the Orion molecular cloud might contain two late-type long-period variable stars that may be semiregular variables.

Snyder, L. E.

Saturation and beaming in astrophysical masers. III - Asymmetrically pumped masers

There is reason to believe that the physical conditions in many astrophysical masers are far from homogeneous. In particular, if the maser pump involves the absorption of infrared photons, the pump rate may vary rapidly (perhaps exponentially) across the cloud. The consequences of such variation of the pump rate for the maser radiation are calculated, and it is shown that there are substantial asymmetries in the output of the maser. A general result is that the maser radiation is preferentially emitted back toward the source of pump radiation. The implication of this result for the interpretation of the circumstellar 1612 MHz OH masers is briefly discussed.

Alcock, C.

Theoretical comparison of maser materials for a 32-GHz maser amplifier

The computational results of a comparison of maser materials for a 32 GHz maser amplifier are presented. The search for a better maser material is prompted by the relatively large amount of pump power required to sustain a population inversion in ruby at frequencies on the order of 30 GHz and above. The general requirements of a maser material and the specific problems with ruby are outlined. The spin Hamiltonian is used to calculate energy levels and transition probabilities for ruby and twelve other materials. A table is compiled of several attractive operating points for each of the materials analyzed. All the materials analyzed possess operating points that could be superior to ruby. To complete the evaluation of the materials, measurements of inversion ratio and pump power requirements must be made in the future.

Lyons, James R.

Radiative transfer in astronomical masers. III - Filamentary masers

The complete solution of a filamentary maser is presented. An integral equation and an iterative procedure are developed to calculate and solve the contribution of rays emanating from the filament sidewall. The solution provides complete expressions for the distributions of intensity and flux across the source as functions of position and direction with regard to the axis. The results are used to find the number distribution of brightness temperature in a large sample of randomly oriented filaments with an arbitrary distribution of lengths. The effects of external radiation on the maser structure and intensity are studied. It is proposed that the two giant bursts of H2O maser emission observed in W49 and Orion resulted from the interaction or two interacting filaments and a foreground slab amplifying a background filament.

Elitzur, Moshe

Atomic hydrogen for low temperature atomic hydrogen masers and in-vacuum dissociators for VLG-11 series masers

The operation of a cryogenically-cooled hydrogen maser using an RF plasma dissociator operating at liquid nitrogen temperature (77K) in confunction with a state selector magnet whose dimensions are suitable for slow atoms is studied. The focusing characteristics for a hexapole state selector magnet with maximum fields at the pole tips, provide a maximum acceptance angle for atoms at the most probable velocity in the beam. By thermally isolating the RF circuitry from the dissociator glassware, only dielectric losses in the glass and the energy coupled to the plasma will result in the boil-off of liquid nitrogen. It is estimated that this is about one watt and thus a loss rate of approximately .022 liters pr hour is anticipated.

Vessot, R. F. C.

Astrophysical masers; Proceedings of the Conference, Arlington, VA, Mar. 9-11, 1992

Various papers on astrophysical masers are presented. The general topics addressed include: theory, maser surveys, extragalactic masers, masers in star-forming regions (general), OH masers in star-forming regions, water masers in star-forming regions, methanol masers in star-forming regions, proper motions, scattering, variability, circumstellar masers (general), circumstellar OH masers, circumstellar water masers, circumstellar SiO masers, and solar system masers.

Clegg, Andrew W.

Complete the development and construction of a spaceborne hydrogen maser clock

The objective, to complete the development of an engineering model of a spaceborne hydrogen maser, was successfully achieved. A layout of the maser and detail drawings of the physics package was completed during the first 7 months of the contract. A computer model was made for the maser's thermal design. Using numerical computations, heater resistances were established for 7 temperature controlled zones. The physics package includes: a vacuum manifold that houses four sorption pumps capable of scavenging hydrogen for 4 years, a titanium vacuum tank housing the cavity, metallic seals for all vacuum joints, an RF dissociator within the vacuum envelope, a two-layer printed circuit solenoid and four layers of moly-permalloy magnetic shields. Problems were encountered and overcome in the procurements of the PC solenoid and the magnetic shields. After completion of the fabrication of the maser's components, the maser was assembled using these parts and other components made available by SAO, NRL, and NASA from earlier development work. In March, 1990, the vacuum system was assembled, and by May the maser assembly was completed. The magnetic shielding was poor and the shields were removed, reannealed by a local vendor, and the maser was reassembled. The maser began tests in early June and has been oscillating since that time. The test results of the maser are very good and a life test of the maser is being conducted. It is anticipated that the development and construction of a maser to be tested in space under a new contract from NASA's Marshall Space Flight Center will continue.

Vessot, Robert F. C.

A receiver design for the superconducting cavity-maser oscillator

A new frequency standard was demonstrated with the aid of a double phase locked loop (PLL) receiver. A superconducting cavity maser oscillator (SCMO) and a hydrogen maser are combined to show the medium term performance of the hydrogen maser together with improved short term performance made possible by the SCMO. The receiver, which generates a 100 MHz signal with reduced noise, is phase locked to (and may be used in place of) the 100 MHz hydrogen maser output. The maser signal, 2.69xxx-GHz SCMO output, and a 100 MHz quartz crystal oscillator are optimally combined by the receiver. A measured two source fractional frequency stability of 2 x 10(exp -14) was obtained for a measuring time of r = 1 sec, and 1 x 10(exp -15) at r = 1,000 sec. The 1 sec value is approx. 10 times lower than that for hydrogen masers, while the 1,000 sec value is identical to hydrogen maser performance. The design is based on phase noise models for the hydrogen maser, the SCMO, and quartz crystal oscillators for offset frequencies down to 1 x 10(exp -6) Hz.

Wang, R. T.

A correlational analysis of the effects of changing environmental conditions on the NR atomic hydrogen maser

An extensive statistical analysis has been undertaken to determine if a correlation exists between changes in an NR atomic hydrogen muser's frequency offset and changes in environmental conditions. Data have been acquired over the past 20 months by recording the frequency offset of three NR atomic hydrogen masers along with the relative and absolute humidity, barometric pressure, and ambient temperature of the laboratory in which the masers are maintained. Correlational analyses have been performed comparing barometric pressure, humidity, and temperature with maser frequency offset as functions of time for periods ranging from 5.5 to 17 days. Semi partial correlation coefficients as large as -0.9 have been fond between barometric pressure and maser frequency offset for data covering periods as long as a week. Maser frequency offset and barometric pressure were consistently found to change simultaneously. The correlation between humidity and frequency offset is less predictable, and the resulting semi partial correlation coefficients were usually small when compared with those derived from the relationship between pressure and frequency offset. The time delay between changes in humidity and correlated changes in maser frequency offset was found to vary extensively with no predictable pattern. Analysis of temperature data indicates that, in the most current design, temperature does not significant(y affect maser frequency offset in the laboratory environment. Thus, the results of the analyses disclose a significant statistical correlation between changes in maser frequency offset and changes in barometric pressure. The statistics also reveal some correlation between humidity and frequency offset, bat for reasons to be discussed, the effects of humidity should be considered secondary to the effects of changing barometric pressure.

R. A. Dragonette

Characteristics of advanced hydrogen maser frequency standards

In house research and development at Goddard Space Flight Center to provide advanced frequency and time standards for the most demanding applications is concentrated primarily in field operable atomic hydrogen masers. Some of the most important goals for the new maser designs have been improved long and short term stability, elimination of the need for auto tuning, increased maser oscillation level, improved hydrogen economy, increased operational life, minimization of operator control or monitoring, improvement in magnetic isolation or sensitivity, and reduction in size and weight. New design concepts which have been incorporated in these masers to achieve these goals are described. The basic maser assemblies and control systems have recently been completed; the masers are oscillating; and operational testing has begun. Data illustrating the improvements in maser performance was available and presented.

Peters, H. E.

X- and K-band maser development: Effects of interfering signals

Signals at levels exceeding - 90 dbmW at the input connection of a traveling-wave maser can affect maser performance in a variety of ways. Both S band and X band masers are considered where interfering signals are: (1) within the maser bandpass, (2) near the maser bandpass, and (3) far from the maser bandpass, where mixing with the maser pump can occur.

Clauss, R. C.

Dielectric-loaded waveguide circulator for cryogenically cooled and cascaded maser waveguide structures

A dielectrically loaded four port waveguide circulator is used with a reflected wave maser connected to a second port between first and third ports to form one of a plurality of cascaded maser waveguide structures. The fourth port is connected to a waveguide loaded with microwave energy absorbing material. The third (output signal) port of one maser waveguide structure is connected by a waveguide loaded with dielectric material to the first (input) port of an adjacent maser waveguide structure, and the second port is connected to a reflected wave maser by a matching transformer which passes the signal to be amplified into and out of the reflected wavemaser and blocks pumping energy in the reflected wave maser from entering the circulator. A number of cascaded maser waveguide structures are thus housed in a relatively small volume of conductive material placed within a cryogenically cooled magnet assembly.

Clauss, R. C.

A kind of small hydrogen maser for time-keeping

A kind of small hydrogen maser standard for timekeeping is being developed at Shanghai Observatory. The maser employs a cylindrical capacitively loaded cavity construction, resulting in significant size and weight reduction compared to a traditional hydrogen maser. The Q of the compact cavity is electronically enhanced by a suitable positive feedback into the cavity to enable sustained maser oscillation. The long-term stability of the maser is improved by a cavity frequency stabilization servo-system. The design and development of the maser, as well as photographs of the new maser system during the construction phase.

Z. C. Zhai

S Persei: Optical and water maser variability - 1984 to 1990

The M supergiant S Persei was monitored since 1984 optically and since 1987 for water maser emission at 22 GHz. The dozen H2O maser features show complex variations in intensity with many of the features varying independently of one another. Some of the water maser features brightened dramatically at the time of the bright optical maximum observed in 1988 August and again 10 weeks later. It is possible the increase in water maser intensity is related to the ejection of a dust shell near the time of the preceding optical minimum. The intensity variations of the maser spectrum as being produced by an asymmetric distribution of maser spots are interpreted. A double shell of maser spots may be present on the near side of the shell, but appears to be lacking or be occulted on the far side. No chromospheric activity was detected about 10 weeks after optical maximum. A well developed shock is seen in a near-infrared spectrum obtained in 1988 October.

Little-Marenin, I. R.