Engineering PapersSearch

SEARCH · Engineering Papers

Results for “JUSTIFI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

The infeasibility of quantifying the reliability of life-critical real-time software

This paper affirms that the quantification of life-critical software reliability is infeasible using statistical methods, whether these methods are applied to standard software or fault-tolerant software. The classical methods of estimating reliability are shown to lead to exorbitant amounts of testing when applied to life-critical software. Reliability growth models are examined and also shown to be incapable of overcoming the need for excessive amounts of testing. The key assumption of software fault tolerance - separately programmed versions fail independently - is shown to be problematic. This assumption cannot be justified by experimentation in the ultrareliability region, and subjective arguments in its favor are not sufficiently strong to justify it as an axiom. Also, the implications of the recent multiversion software experiments support this affirmation.

Butler, Ricky W.

Biological processes and optical measurements near the sea surface: Some issues relevant to remote sensing

The advent of remote sensing, the develpmemt of new optical instrumentation, and the associated advances in hydrological optics have transformed oceanography; it is now feasible to describe ocean-scale biogeochemical dynamcis from satellite observations, verified and complemented by measurements from optical sensors on profilers, moorings, and drifters. Only near-surface observations are common to both remote sensing and in situ observation, so it is critical to understand processes in the upper euphotic zone. Unfortunately, the biological principles that must be used to interpret optical variability near the sea surface are weaker than we would like, because relatively few experiments and analyses have examined bio-optical relationships under high irradiance characteristic of the upper optical depth. Special consideration of this stratum is justified, because there is good evidence that bio-optical relationships are altered near the surface; (1) the fluorescence yield from chlorophyll declines, leading to bias in the estimation of pigment from fluorometry; (2) the modeled relationship between solar-stimulated fluorecence and photosynthesis seems to deviate significantly from that presented for the lower euphotic zone; and (3) carbon-specific and cellular attenuation cross sections of phytoplankton change substantially during exposures to bright light. Even the measurement of primary productivity is problematic near the sea surface, because vertical mixing is not simulated and artifactual inhibition of photosynthesis can result. These problems can be addressed by focusing more sampling effort, experimental simulation, and analytical consideration on the upper optical depth, and by shortening timescales for the measurement of marine photosynthesis. Special efforts to study near-surface processes are justified, because new bio-optical algorithms will require quantitaitve descriptions of the responses of phytoplankton to bright light.

Cullen, John J.

Development of the Space Operations Incident Reporting Tool (SOIRT)

The space operations incident reporting tool (SOIRT) is an instrument used to record information about an anomaly occurring during flight which may have been due to insufficient and/or inappropriate application of human factors knowledge. We originally developed the SOIRT form after researching other incident reporting systems of this type. We modified the form after performing several in-house reviews and a pilot test to access usability. Finally, crew members from Space Shuttle flights participated in a usability test of the tool after their missions. Since the National Aeronautics and Space Administration (NASA) currently has no system for continuous collection of this type of information, the SOIRT was developed to report issues such as reach envelope constraints, control operation difficulties, and vision impairments. However, if the SOIRT were to become a formal NASA process, information from crew members could be collected in a database and made available to individuals responsible for improving in-flight safety and productivity. Potential benefits include documentation to justify the redesign or development of new equipment/systems, provide the mission planners with a method for identifying past incidents, justify the development of timelines and mission scenarios, and require the creation of more appropriate work/rest cycles.

Minton, Jacquie

Case Study Analyses of the SUCCESS DC-8 Scanning Lidar Database

Under project SUCCESS (Subsonic Aircraft Contrail and Cloud Effects Special Study) funded by the Atmospheric Effects of Aviation Program, SRI International (SRI) developed an angular scanning backscatter lidar for operation on the NASA DC-8 research aircraft and deployed the scanning lidar during the SUCCESS field campaign. The primary purpose of the lidar was to generate real-time video displays of clouds and contrails above, ahead of, and below the DC-8 as a means to help position the aircraft for optimum cloud and contrail sampling by onboard in situ sensors, and to help extend the geometrical domain of the in situ sampling records. A large, relatively complex lidar database was collected and several data examples were processed to illustrate the value of the lidar data for interpreting the other data records collected during SUCCESS. These data examples were used to develop a journal publication for the special SUCCESS Geophysical Research Letters issue. The data examples justified data analyses of a larger part of the DC-8 lidar database and is the objective of the current study. Efficient processing of the SUCCESS DC-8 scanning lidar database required substantial effort to enhance hardware and software components of the data system that was used for the initial analyses. MATLAB instructions are used to generate altitude and distance color-coded lidar displays corrected for effects introduced by aircraft pitch and forward movement during an angular scan time interval. Onboard in situ sensor atmospheric measurements are propagated to distances ahead of the DC-8 using recorded aircraft velocity so that they can be plotted on the lidar displays for comparison with lidar remotely observed aerosol distributions. Resulting lidar and in situ sensor polar scan displays over extended sampling intervals are integrated into a time series movie format for 36 case studies. Contrails and clouds were detected to ranges of 15 km by the forward-viewing angular scanning lidar and were progressively mapped as the aircraft approached and penetrated them. Near aircraft lidar observations were much better correlated with in situ sensor observations than lidar observations at greater distances ahead of the aircraft. The major cause of this difference was thought to be the about 2 deg. offset of the lidar viewing direction from the flight direction. Contrail spatial distributions were not of the quality obtainable from ground-based lidar observations. This results because contrails tend to become horizontally stratified, vertical distance between angular lidar observations increases with increased distance from the aircraft, and erratic aircraft motions during an angular scan. The most useful lidar observations were made with lidar viewing directions of vertically upward or vertically downward. These provided real-time information on aircraft altitudes to achieve optimum in situ cloud and contrail sampling. At sampling altitudes, the forward viewing angular scanning observations were useful for fine-tuning the aircraft altitude for cloud and contrail penetration. Best information on cloud and contrail properties were obtained from vertically directed lidar observations as the aircraft performed a series of upward and downward penetrations of contrails. This operational mode was especially well suited for lidar and radiometric evaluation of cloud and contrail optical and radiative properties. The vertical viewing lidar detected ice crystals thought to be precipitating from an aircraft contrail and their scavenging by a cirrus cloud layer. The lidar display indicates that the crystals are effective for increasing cirrus cloud density. Vertical angular scanning observations can evaluate the sharp decrease in lidar backscatter for small off-vertical viewing directions that result from horizontally aligned ice crystals and perhaps can provide additional information on crystal shapes. The about 2 deg. offset of the lidar viewing direction from the flight direction is thought to have greatly degraded the forward-viewing angular scanning observations and this mode of operation was not fully evaluated. However, the reasoning for this capability remains valid and the angular scan presentations collected during this program justifies modification of the lidar pod for true forward direction lidar viewing during future cloud and contrail studies.

Uthe, Edward E.

The Langley Parameterized Shortwave Algorithm (LPSA) for Surface Radiation Budget Studies

An efficient algorithm was developed during the late 1980's and early 1990's by W. F. Staylor at NASA/LaRC for the purpose of deriving shortwave surface radiation budget parameters on a global scale. While the algorithm produced results in good agreement with observations, the lack of proper documentation resulted in a weak acceptance by the science community. The primary purpose of this report is to develop detailed documentation of the algorithm. In the process, the algorithm was modified whenever discrepancies were found between the algorithm and its referenced literature sources. In some instances, assumptions made in the algorithm could not be justified and were replaced with those that were justifiable. The algorithm uses satellite and operational meteorological data for inputs. Most of the original data sources have been replaced by more recent, higher quality data sources, and fluxes are now computed on a higher spatial resolution. Many more changes to the basic radiation scheme and meteorological inputs have been proposed to improve the algorithm and make the product more useful for new research projects. Because of the many changes already in place and more planned for the future, the algorithm has been renamed the Langley Parameterized Shortwave Algorithm (LPSA).

Gupta, Shashi K.

The Infeasibility of Experimental Quantification of Life-Critical Software Reliability

This paper affirms that quantification of life-critical software reliability is infeasible using statistical methods whether applied to standard software or fault-tolerant software. The key assumption of software fault tolerance|separately programmed versions fail independently|is shown to be problematic. This assumption cannot be justified by experimentation in the ultra-reliability region and subjective arguments in its favor are not sufficiently strong to justify it as an axiom. Also, the implications of the recent multi-version software experiments support this affirmation.

Butler, Ricky W.

The Infeasibility of Quantifying the Reliability of Life-Critical Real-Time Software

This paper affirms that the quantification of life-critical software reliability is infeasible using statistical methods whether applied to standard software or fault-tolerant software. The classical methods of estimating reliability are shown to lead to exhorbitant amounts of testing when applied to life-critical software. Reliability growth models are examined and also shown to be incapable of overcoming the need for excessive amounts of testing. The key assumption of software fault tolerance separately programmed versions fail independently is shown to be problematic. This assumption cannot be justified by experimentation in the ultrareliability region and subjective arguments in its favor are not sufficiently strong to justify it as an axiom. Also, the implications of the recent multiversion software experiments support this affirmation.

Butler, Ricky W.

Let's Orbit Mars: A Proposal to Explore Mars Now

Mars is an exciting target for the human exploration; the next destination toward the ultimate human colonization of the solar system. But the price of proposed missions to Mars is a daunting barrier. Expensive missions make it a slow and difficult process to achieve the political consensus to make a commitment to exploration. In today's deficit-conscious era (and what era is not?), it is as difficult-- perhaps impossible-- task to justify to a skeptical and cost-conscious public the need to invest in exploration. It seems far too easy to postpone exploration into a future that never seems to arrive. It would be terrific to explore Mars in small steps, where each step makes progress toward human exploration and settlement, and each step also is not only exciting to the public, but also justifiable on its own scientific merits.

Landis, Geoffrey A.

Mars Sample Return - studies for a fresh look

Included in the paper are both the themes resulting from the industry studies and the general scope of the focused concepts used to assess the current planning for the Mars Sample Return (MSR) mission and precursor missions. Included in this conference are papers by the four industrial teams, as well as a fifth study by JPL's Team-X to provide further corroboration of study results. The results suggest that a scientifically justifiable mission is possible, and that technology and precursor mission demonstration plans currently in the Mars Program are justified (with some modifications).

Mars Sample Return MSR

Heliocentric Distance of Coronal Mass Ejections at the Time of Energetic Particle Release: Revisiting the Ground Level Enhancement Events of Solar Cycle 23

Using the kinematics of coronal mass ejections (CMEs), onset time of soft X-ray flares, and the finite size of the pre-eruption CME structure, we derive the heliocentric distan~e at which the energetic particles during the ground level enhancement (GLE) events of Solar Cycle 23. We find that the GLE particles are released when the CMEs reach an average heliocentric distance of approx.3.25 solar radii (Rs). From this we infer that the shocks accelerating the particles are located at similar heights. Type II radio burst observations indicate that the CMEs are at much lower distances (average approx.1.4 Rs) when the CME-driven shock first forms. The shock seems to travel approx.1.8 Rs over a period of approox.30 min on the average before releasing the GLE particles. In deriving these results, we made three assumptions that have observational support: (i) the CME lift off occurs from an initial distance of about 1.25 Rs; (ii) the flare onset and CME onset are one and the same because these are two different manifestations of the same eruption; and (iii) the CME has positive acceleration from the onset to the first appearance in the coronagraphic field of view (2.5 to 6 Rs). Observations of coronal cavities in eclipse pictures and in coronagraphic images justify the assumption (i). The close relationship between the flare reconnection magnetic flux and the azimuthal flux of interplanetary magnetic clouds justify assumption (ii) consistent with the standard model (CSHKP) of solar eruption. Coronagraphic observations made close to the solar surface indicate a large positive acceleration of CMEs to a heliocentric distance of approx.3 Rs before they start slowing down due to the drag force. The inferred acceleration (approx.1.5 km/s/s) is consistent with reported values in the literature.

Gopalswamy, Natchimuthuk

An Intelligent Strain Gauge with Debond Detection and Temperature Compensation

The harsh rocket propulsion test environment will expose any inadequacies associated with preexisting instrumentation technologies, and the criticality for collecting reliable test data justifies investigating any encountered data anomalies. Novel concepts for improved systems are often conceived during the high scrutiny investigations by individuals with an in-depth knowledge from maintaining critical test operations. The Intelligent Strain Gauge concept was conceived while performing these kinds of activities. However, the novel concepts are often unexplored even if it has the potential for advancing the current state of the art. Maturing these kinds of concepts is often considered to be a tangential development or a research project which are both normally abandoned within the propulsion-oriented environment. It is also difficult to justify these kinds of projects as a facility enhancement because facility developments are only accepted for mature and proven technologies. Fortunately, the CIF program has provided an avenue for bringing the Intelligent Strain Gauge to fruition. Two types of fully functional smart strain gauges capable of performing reliable and sensitive debond detection have been successfully produced. Ordinary gauges are designed to provide test article data and they lack the ability to supply information concerning the gauge itself. A gauge is considered to be a smart gauge when it provides supplementary data relating other relevant attributes for performing diagnostic function or producing enhanced data. The developed strain gauges provide supplementary signals by measuring strain and temperature through embedded Karma and nickel chromium (NiCr) alloy elements. Intelligently interpreting the supplementary data into valuable information can be performed manually, however, integrating this functionality into an automatic system is considered to be an intelligent gauge. This was achieved while maintaining a very low mass. The low mass enables debond detection and temperature compensation to be performed when the gauge is utilized on small test articles. It was also found that the element's mass must be relatively small to avoid overbearing the desired thermal dissipation characteristics. Detecting the degradation of a gauge s bond was reliably achieved by correlating thermal dissipation with the bond s integrity. This was accomplished by precisely coupling a NiCr element with a Karma element for accurately interjecting and quantifying thermal energy. A finite amount of thermal energy is consistently placed in the gauge by electrically powering the NiCr element. The energy will only be temporarily stored before it begins to dissipate into the surrounding structure through the gauge bond. The ability to transmit the energy into the structure becomes greatly inhibited by any discontinuity in the bond s substrate. Therefore, the way the thermal dissipation occurs will reveal even the slightest change in the integrity of the bond.

Jensen, Scott L.

Behavior of Triple Langmuir Probes in Non-Equilibrium Plasmas

The triple Langmuir probe is an electrostatic probe in which three probe tips collect current when inserted into a plasma. The triple probe differs from a simple single Langmuir probe in the nature of the voltage applied to the probe tips. In the single probe, a swept voltage is applied to the probe tip to acquire a waveform showing the collected current as a function of applied voltage (I-V curve). In a triple probe three probe tips are electrically coupled to each other with constant voltages applied between each of the tips. The voltages are selected such that they would represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Under the assumption of a Maxwellian plasma, one can determine the time-varying plasma temperature T(sub e)(t) and number density n(sub e)(t) from the applied voltage levels and the time-histories of the collected currents. In the present paper we examine the theory of triple probe operation, specifically focusing on the assumption of a Maxwellian plasma. Triple probe measurements have been widely employed for a number of pulsed and timevarying plasmas, including pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. While the equilibrium assumption may be justified for some applications, it is unlikely that it is fully justifiable for all pulsed and time-varying plasmas or for all times during the pulse of a plasma device. To examine a simple non-equilibrium plasma case, we return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. We compare the distribution function that was assumed a priori with the distribution function one would infer when applying standard triple probe theory to analyze the collected currents. For the assumed class of non-Maxwellian distribution functions this serves to illustrate the effect a non-Maxwellian plasma would have on results interpreted using the equilibrium triple probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.

Polzin, Kurt A.

Behavior of Langmuir Probes in Non-Equilibrium Plasmas

Langmuir probes are diagnostic tools used to determine electron temperature, number density, and plasma potential. Irving Langmuir first used an electrostatic probe in the 1920s to find these characteristics in ionized gases. Single, double, and triple Langmuir probes are commonly used in plasma diagnostics because of their relative simplicity. In the single probe, a swept voltage is applied between the probe tip and circuit common to acquire a waveform showing the collected current as a function of applied voltage. A double Langmuir probe consists of two tips, both inserted into the plasma, with a voltage applied between them. As this voltage is swept, a current-voltage characteristic is measured. In a triple probe three probe tips are electrically coupled to each other with constant non-swept voltages applied between each of the tips. The voltages are selected to represent three points on the single Langmuir probe I-V curve. Elimination of the voltage sweep makes it possible to measure time-varying plasma properties in transient plasmas. Triple Langmuir probe measurements have been widely employed for various types of plasmas, including pulsed and time-varying plasmas such as those seen in pulsed plasma thrusters (PPTs), dense plasma focus devices, plasma flows, and fusion experiments. The typical Langmuir probe analysis for determining electron temperature and number density of the plasma (for a single, double, or triple Langmuir probe) includes an assumption that the plasma is in thermal equilibrium. While the this assumption may be justified for some applications, it is unlikely that it is fully justifiable for pulsed and time-varying plasmas or for the entire time a plasma device is in use. In the present work, we model the responses of Langmuir probes as they are inserted into a range of simple equilibrium and non-equilibrium plasmas. We return to basic governing equations of probe current collection and compute the current to the probes for a distribution function consisting of two Maxwellian distributions with different temperatures (the two-temperature Maxwellian). A variation of this method is also employed, where one of the Maxwellians is offset from zero (in velocity space) to add a suprathermal beam of electrons to the tail of the main Maxwellian distribution (the bump-on-the-tail distribution function). For a range of parameters in these non-Maxwellian distributions, we compute the current collection to the probes. Comparing the distribution function that was assumed a priori with the plasma density and temperature one would infer when applying standard probe theory to analyze the collected currents serves to illustrate the effect a non- Maxwellian plasma would have on results interpreted using the equilibrium probe current collection theory, allowing us to state the magnitudes of these deviations as a function of the assumed distribution function properties.

Polzin, Kurt A.

Using GPS Receiver 1PPS Output to Verify Time Stamp Accuracy and Measure Propagation Delay

A simple pulse overlay circuit using a logic OR gate was developed to overlay a precise leading edge 1 pulse per second time reference marker from a global positioning system receiver onto a non-return -to- zero-level pulse code modulation telemetry data stream to validate time stamp accuracy and measure propagation delay in telemetry equipment. A pulse overlay (PO) circuit was designed to produce a time reference marker within a pulse code modulation (PCM) telemetry data stream that was recorded and analyzed to validate an IRIG Standard 106-17 Chapter 10 recorder’s time stamp accuracy [1]. A manufacturer of a newly purchased Chapter 10 recorder claimed the time stamp accuracy to be better than 10 microseconds (μs) with only IRIG-B120 (IRIG-B) input and better than 1 μs with IRIG-B and one pulse per second (1PPS) inputs. The PO circuit and a Chapter 10 recorder test setup were used to verify the vendor’s data-time synchronization claims and to justify infrastructure upgrade costs to connect additional cables to each purchased recorder. The circuit was also used to measure the propagation delay (PD) of a long distance Telemetry multiplexer/demultiplexer telecommunication system which the manufacturer did not provide a PD specification. Using the one pulse per second time reference marker of the global positioning system receiver and the pulse overlay circuit to overlay the one pulse per second variable pulse width signal into a pulse code modulation telemetry stream provided an excellent means to validate time stamp accuracy within a Chapter 10 recorder and to measure propagation delays within a normal telemetry operating environment. The positive results from the Chapter 10 recorder tests validated the vendor’s claims and justified the implementation to add the one pulse per second signal to the range Chapter 10 recorders. The pulse overlay circuit and test setups defined in this paper can easily be used to measure other telemetry equipment.

Knudtson, Kevin

A Combined Al-Mg/Pb-Pb Age of the Solar System

Astrophysical models of planet formation and protoplanetary disk evolution demand precise and accurate timing of the sequence of events in the solar nebula, relative to a time t=0, usually taken to be during the short epoch of CAI (Ca-rich, Al-rich inclusion) formation. Most CAIs formed withlive26Al (mean-life τ26= 1.034 Myr [1]), with an abundance 26Al/27Al ≈ (26Al/27Al)SS= 5.23 × 10-5[2]. We adopt this as the widespread level of 26Al in the solar nebula at t=0. Assuming spatial homogeneity of 26Al, an inclusion that had less 26Al, (26Al/27Al)0, formed a time Δt26= τ26ln[(26Al/27Al)SS/ (26Al/27Al)0] after t=0.These ages are typical precise to within ±0.1 Myr. Igneous bulk meteorites and inclusions can be relatively dated by the Al-Mg chronometer, but only ifΔt26<6 Myr. The Pb-Pb system is useful as a longer relative chronometer. It yields absolute ages tPb using 207Pb/206Pb, 206Pb/204Pb, and 238U/235U ratios measured indifferent portions of a sample, assuming certain half-lives [4]. These absolute ages are uncertain to within ±9 Myr due to uncertainties in the 235U half-life[3], but times of formation ΔtPb= tCAI–tPb relative to t=0, are more precise(±0.5Myr),iftCAI can be found. Here, tCAI means the Pb-Pb age that would be measured in CAIs using the half-lives the community typically uses, if they achieved isotopic closure at t=0. Unfortunately, direct Pb-Pb dating of CAIs has not definitively determined tCAI. Based on four CAIs with canonical (26Al/27Al)0,[5,6] found tPb= 4567.30 ± 0.16 Myr. No other CAI ages with measured 238U/235U have been reported in the refereed literature, but there are hints of other CAIs with ages tPb= 4568.0 ± 0.2 Myr [7] and tPb= 4568.3 ± 0.2 Myr [8].It is unclear whether anyof these igneous type B CAIs isotopically closed at t=0 or represents tCAI. Instead of measurements, we advocate finding tCAI by minimizing the discrepancies between the Al-Mg and Pb-Pb chronometers. Assuming Δt26=ΔtPb, we find the implied t’CAI= tPb+Δt26, then define t*CAIas the weighted mean of the t’CAI. t*CAIis the best guess for the Pb-Pb age of t=0; the assumption of homogeneity is justified if the t’CAI cluster within errors around t*CAI. This statistical approach is similar to, but improves on, that of[9]. We find t*CAI= 4568.73 ± 0.16 Myr. Below we discuss our methodology and the implications of this age for CAIs, 1.4 Myr older than the reported and typically used age 4567.30±0.16 Myr. Methods: We base our estimate of t*CAIon five achondrites for which published (26Al/27Al)0and Pb-Pb ages exist: the quenched angrites D’Orbigny, Sahara 99555 (SAH 99555), and Northwest Africa (NWA) 1670; the pseudo-eucrite Asuka 881394; and the inner disk achondrite. All are “NC” (non-carbonaceous) achondrites that likely cooled quickly enough that the Al-Mg and Pb-Pb systems achieved isotopic closure simultaneously. We also considered the “CC” (carbonaceous chondrite-like) achondrites NWA 2796 and NWA 6704, butdo not include them in our fit. Al-Mg and Pb-Pb seem not to have closed simultaneously, possibly because formation in the outer disk from volatile-rich composition led to slower cooling. Of the 8 chondrules from NWA 5697 measured by [20,21], we also consider the 4 for which 238U/235U was measured: 2-C1, 5-C2, 3-C5, 11-C1.Depending on their post-formation thermal histories, the Al-Mg and Pb-Pb systems in chondrules may or may not have closed simultaneously. Table 1: (26Al/27Al)0, Pb-Pb ages of selected samplesSample(26Al/27Al)0/ 10-6RefPb-PbRefD’Orbigny3.98±0.15104563.43±0.19♮10-12SAH 995553.64±0.18104563.88±0.2712NWA16705.92±0.59104564.39±0.24*10Asuka 88139413.1±0.5613-154564.98±0.1715NWA 73253.03±0.14164563.4±2.616NWA 27963.94±0.16174562.89±0.5917NWA 67043.03±0.14184562.76±0.26192-C17.56±1.53204567.57±0.56*215-C27.04±1.51204567.54±0.52*213-C58.85±1.83204566.20±0.63*2111-C15.55±1.84204565.84±0.72*21*regression based on one subset of data points ♮weighted mean of two datasets Pb-Pb ages are proportional to the intercept of the line formed by linear regression of 207Pb/206Pb vs. 206Pb/204Pb data from various washes, leachates and residues of acid dissolution of a sample. Because contamination by terrestrial or primordial Pb is pervasive, some fractions must be excluded from regressions to ensure a fit with acceptable mean squares weighted deviation (MSWD). Usually points are excluded based on low [Pb], or low 206Pb/204Pb ratio(low radiogenic component), with single outliers identified [11,12,15,16,17]. In the starred examples (Table 1)and the case of 3 CAI Pb-Pb ages [5], up to half the points were excluded solely because did not fit a pre-determined line. This approach is vulnerable to confirmation bias and produces fits with low MSWD and too-low Pb-Pb age uncertainty. Regressing the same data points as [10], were produce the Pb-Pb age of NWA 1670 of 4564.39±0.24 Myr. But selecting other combinations of data points, other, equally valid, isochrons yield ages from 4563.77±0.21 Myr to 4564.64±0.23 Myr. Similar arguments apply to the Pb-Pb isochrons built by [21] for chondrules 2-C1 (we find 4567.33±0.44 to 4567.85±0.46 Myr), 5-C2 (4566.84±0.53 to 4567.70±0.44 Myr), 3-C5 (4565.84±0.54to 4567.04±0.54)and 11-C1 (4565.36±0.51 to 4565.74±0.45 Myr). Our adopted ages for these and NWA 1670 are listed in Table 2.Table 2. tCAI estimated from various components, using our regressions for the chondrules & NWA 1670.SampleΔt26(Myr)tPb(Myr)t’CAI(Myr)D’Orbigny5.05±0.044563.43±0.194568.48±0.19SAH 995555.14±0.054563.88±0.274569.02±0.27NWA16704.64±0.104564.21±0.634568.85±0.67Asuka 8813943.81±0.044564.98±0.174568.79±0.17NWA 73255.33±0.054563.4±2.64568.7±2.6NWA 27965.06±0.044562.89±0.594567.95±0.59NWA 67045.29±0.134562.76±0.264568.05±0.292-C12.00±0.214567.59±0.704569.59±0.725-C22.07±0.224567.23±0.914569.30±0.933-C51.84±0.214566.44±1.124568.28±1.1411-C12.32±0.344565.52±0.664567.84±0.73achondrite4568.72±0.16chondrules4568.76±0.58combined4568.73±0.16A weighted average of the five NC achondrites(or just D’Orbigny, SAH 99555 and Asuka 881394)yields t*CAI= 4568.72 ± 0.16Myr. All are consistent with this value to within 1.8σ, and MSWD=1.5. Including the 4 U-corrected chondrules, t*CAI= 4568.73± 0.16Myrwith MSWD=1.66, which is statistically significant. All chondrules and NC achondrites are consistent with this to within 1.8σ, (Figure 1).Figure 1. Al-Mg formation times after t=0 vs. Pb-Pb ages. The five NC achondrites and four chondrules are consistent with a Pb-Pb age of t=0 of 4568.7 Myr. Discussion: The data from achondrites and chondrules are consistent with a single Pb-Pb age at t=0, justifying the assumption of 26Al homogeneity. The age, 4568.7 Myr, is ≈1.4 Myr older than the commonly accepted Pb-Pb age of CAIs that formed with canonical 26Al/27Al at t=0 [3]. Others have interpreted the discrepancy to signify 26Al heterogeneity in the CAI-forming region[5,21]. We suggest instead that CAIs were exposed to transient heating events that reset the Pb-Pb system without disturbing the Al-Mg system. Notably, chondrules typically experienced transient heating at these times in the nebula [22]. If so, direct measurements of CAIs will not yield as reliable a Pb-Pb age of t=0 as statistical approaches like this and that of [9].References:[1] Auer et al. 2009. [2] Jacobsen, B et al. 2008, EPSL 272, 353-364. [3] Tissot, Fet al. 2017, GCA 213, 593-617.[4] Villa, I et al. 2016, GCA 172, 387-392.[5] Amelin, Y et al. 2010, EPSL 300, 343-350.[6] Connelly, Jet al. 2012, Science 338, 651.[7] Bouvier, Aet al. 2011, LPICo 1639, 9054. [8] Bouvier, Aand Wadhwa, M2010, Nat Geosci 3, 637-641.[9] Nyquist, Let al. 2009, GCA 73, 5115-5136.[10] Schiller et al. 2015. [11] Wadhwa & Brennecka 2012. [12] Tissot et al. 2017. [13] Nyquist et al. 2003. [14] Wadhwa et al. 2009. [15] Wimpenny et al. 2019, GCA 244, 478-501.[16] Koefoed et al. 2016, GCA 183, 31-45. [17] Bouvier, A et al. 2011, GCA 75, 5310-5323. [18] Sanborn, Met al. 2019, GCA 245, 577-596. [19] Amelin, Yet al. 2019, GCA 245, 628-642.[20] Bollard, Jet al. 2017, Sci Adv 3 ,e1700407. [21] Bollard, Jet al. 2019, GCA 260, 62-83.[22] Villeneuve, J et al. 2009, Science 325, 985

S. J. Desch

Feasibility of Nitrogen as a Carrier Gas for Inconel Cold Spray in Hydropower Application

Cold spray deposition of Inconel nickel alloys has emerged as a promising strategy for mitigating cavitation erosion in hydropower facilities. Most prior developments employ helium (He) as the carrier gas because it enables high particle velocities and the formation of dense coatings. However, He is nearly two orders of magnitude more expensive than nitrogen (N2), which limits its widespread adoption in the hydropower sector. Although He-based cold spray can be justified for high value repairs, the lower cost and broad availability of N2 make it an attractive alternative. This study assesses the feasibility of N2-based cold spray of Inconel 625 powders for hydropower applications. Cavitation erosion testing shows that He-based coating exhibits cavitation resistance of ~398% relative to the 304L stainless steel (SS304L) substrate. In contrast, N2-based coating shows substantially lower cavitation resistance, reaching only ~69% of the SS304L substrate, even when higher carrier gas temperature and pressure are applied. When the Inconel 625 powder size is reduced from 44 to 22 µm under N2-based cold spray conditions, cavitation resistance increases significantly to ~148% of the SS304L substrate. Additional improvement can be obtained by incorporating fine chromium carbide powders into the feedstock, resulting in cavitation resistance of ~172% of the SS304L substrate. Overall, with optimized feedstock design, N2-based cold spray offers a practical and cost-effective approach for producing cavitation resistant coatings on hydropower components, although He-based cold spray continues to deliver higher cavitation resistance.

Wang, Tianhao

Fluorinated Rocksalt‐Polyanion Cathode for Lithium‐Ion Batteries

Integrated rocksalt‐polyanion cathodes (DRXPS) are promising candidates for next‐generation lithium‐ion battery cathode materials that combine high energy density, stable cycling performance, and reduced reliance on Co and Ni. In this work, we investigated Li 3 Mn 1.6 P 0.4 O 5.4 F 0.6 , a new DRXPS cathode with fluoride incorporation. A pure spinel phase was formed and a discharge capacity retention of 84% was achieved after 200 cycles between 1.5 and 4.8 V versus Li/Li + . In comparison, the similarly synthesized Li 3 Mn 1.6 Nb 0.4 O 5.4 F 0.6 , in which all P 5+ was substituted by Nb 5+ while maintaining the same stoichiometry for all other elements, crystallized in a disordered rocksalt structure, and exhibited inferior capacity retention and rate capability than the P 5+ counterpart. Our findings expand the compositional space of DRXPS to include F − , justify the viability of integrating polyanion groups in rocksalt‐type cathodes, and highlight the superiority of P 5+ as a cation charge compensator compared to the commonly used Nb 5+ . This work thereby advances the design of robust, high‐performance cathode materials for sustainable batteries.

36 MATERIALS SCIENCE

Importance of Sample Handling and Preparation for Surface Analysis: A Summary of ISO Standard 20579 Part 1, Documenting and Reporting the Handling of Specimens Prior to Analysis

Reliable and reproducible analysis of surfaces is critically dependent on how samples have been collected, handled, and prepared before analysis. Although there are important, well-established general guidelines to minimize unintended alteration of the surfaces to be analyzed, specific handling steps depend on the nature of the samples and information desired. Assessments of the validity and reliability of the results require adequate information about sampling, handling, and processing. ISO standard 20579 part 1 describes the information to be recorded and reported for samples that are prepared or submitted for surface analysis. This paper summarizes elements of the standard, which includes annexes that justify and inform the sample handling processes. Also included is a checklist of information that needs to be recorded and reported and an appendix containing an example of a form that might be used to report the information.

AES