Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Nitrogen Isotopic Ratio in Jupiter's Atmosphere from Observations by Composite Infrared Spectrometer (CIRS) on the Cassini Spacecraft

The Composite Infrared Spectrometer (CIRS) on the Cassini spacecraft made infrared observations of Jupiter's atmosphere during the flyby in December 2000 to January 2001. The unique database in the 600-1400/cm region with 0.53 and 2.8/cm spectral resolutions obtained from the observations permits retrieval of global maps of the thermal structure and composition of Jupiter's atmosphere including the distributions of (14)NH3 and (15)NH3. Analysis of Jupiter's ammonia distributions from three isolated (15)NH3 spectral lines in eight latitudes is presented for evaluation of the nitrogen isotopic ratio. The nitrogen isotopic ratio (14)N/(15)N (or (15)N/(14)N) in Jupiter's atmosphere in this analysis is calculated to be: 448 +/- 62 ((2.23 +/- 0.31) x 10(exp -3)). This value of the ratio determined from CIRS data is found to be in very close agreement with the value previously obtained from the measurements by the Galileo Probe Mass Spectrometer. Some possible mechanisms to account for the variation of Jupiter's observed isotopic ratio relative to various astrophysical environments are discussed.

Abbas, M. M.↗

Application of ATONA Amplifiers to the Measurement of Uranium Isotopic Ratios by Thermal Ionization Mass Spectrometry

Uranium isotopic composition can provide valuable information about the history and provenance of a nuclear material; therefore, uranium isotopic analyses are frequently made in the nuclear forensics, safeguards, and environmental monitoring communities. These measurements have always presented challenges due to the extreme variability in the relative abundance between the major ( 235 U, 238 U) and minor ( 233 U, 234 U, 236 U) isotopes of uranium. Here, the recently developed ATONA (Atto- to Nano-Amp) amplification system paired with Faraday cup detectors has a large dynamic range and low noise floor making it ideal for measuring uranium isotopic ratios in materials of both natural and anthropogenic origin. A wide variety of certified reference materials were analyzed to investigate the utility of the ATONA amplification system for determining uranium isotopic composition in samples ranging from depleted to highly enriched. The ATONA amplifiers provide nearly an order of magnitude improvement in external reproducibility over 10 11 Ω amplifiers when measuring the minor 234 U/ 238 U ratio in isotopically natural and depleted samples and when paired with a secondary electron multiplier can measure very low relative abundance uranium isotopes (i.e., 236 U).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mars Atmospheric Escape Recorded by H, C and O Isotope Ratios in Carbon Dioxide and Water Measured by the Sam Tunable Laser Spectrometer on the Curiosity Rover

Stable isotope ratios in C, H, N, O and S are powerful indicators of a wide variety of planetary geophysical processes that can identify origin, transport, temperature history, radiation exposure, atmospheric escape, environmental habitability and biological activity [2]. For Mars, measurements to date have indicated enrichment in all the heavier isotopes consistent with atmospheric escape processes, but with uncertainty too high to tie the results with the more precise isotopic ratios achieved from SNC meteoritic analyses. We will present results to date of H, C and O isotope ratios in CO2 and H2O made to high precision (few per mil) using the Tunable Laser Spectrometer (TLS) that is part of the Sample Analysis at Mars (SAM) instrument suite on MSL s Curiosity Rover.

Webster, C. R.↗

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.↗

Compound-Specific Carbon, Nitrogen, and Hydrogen Isotopic Ratios for Amino Acids in CM and CR Chondrites and their use in Evaluating Potential Formation Pathways

Stable hydrogen, carbon, and nitrogen isotopic ratios (oD, 013C, and olSN) of organic compounds can revcal information about their origin and formation pathways. Several formation mechanisms and environments have been postulated for the amino acids detected in carbonaceous chondrites. As each proposed mechanism utilizes different precursor molecules, the isotopic signatures of the resulting amino acids may indicate the most likely of these pathways. We have applied gas chromatography with mass spectrometry and combustion isotope ratio mass spectrometry to measure the compound-specific C, N, and H stable isotopic ratios of amino acids from seven CM and CR carbonaceous chondrites: CM1I2 Allan Hills (ALH) 83100, CM2 Murchison, CM2 Lewis Cliff (LEW) 90500, CM2 Lonewolf Nunataks (LON) 94101, CRZ Graves Nunataks (GRA) 95229, CRZ Elephant Moraine (EET) 92042, and CR3 Queen Alexandra Range (QUE) 99177. We compare the isotopic compositions of amino acids in these meteorites with predictions of expected isotopic enrichments from potential formation pathways. We observe trends of decreasing ODC and increasing oD with increasing carbon number in the aH, (l-NH2 amino acids that correspond to predictions made for formation via Streckercyanohydrin synthesis. We also observe light ODC signatures for ~-alanine, which may indicate either formation via Michael addition or via a pathway that forms primarily small, straight-chain, amine-terminal amino acids (n-ro-amino acids). Higher deuterium enrichments are observed in amethyl amino acids, indicating formation of these amino acids or their precursors in cold interstellar or nebular environments. Finally, individual amino acids are more enriched in deuterium in CR chondrites than CM chondrites, reflecting different parent-body chemistry.

Elsila, Jamie E.↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry to Enable Increased Renewable Carbon Content in Transportation Fuels (CRADA 525)

Stable isotope ratio measurements of carbon atoms using isotope ratio mass spectrometry (IRMS) can be an effective tool for quantifying biogenic carbon in co-processed fuels, with results approaching the precision and accuracy of accelerator mass spectrometry (AMS). The lower cost of an IRMS may enable deployment to refineries, improving access and analysis turnaround times (≤2 hours), and, by extension, provide data that can allow process optimization to maximize renewable carbon in desired refinery products. This project explored the integration of chemical separation with IRMS analyses to enable highly detailed tracking of biogenic carbon into fuel product streams separated by boiling point range, chemical class, or specific compound. Forty-nine fuels and fuel components of fossil and biogenic origin, spanning gasoline and diesel boiling point ranges, were received from three refiners and were analyzed for their δ 13 C values via IRMS. Results spanned a 13 C range from ca. 10‰ to 44‰ and reflect materials derived from sustainable sources (e.g., C4 or C3 plants, animal-based pathways, syngas) or from fossil-derived fuels. Common ranges are approximately 18‰ to 9‰ and approximately 30‰ to 20‰ for C4 and C3 plants, respectively, and approximately 34‰ to 24‰ and approximately 70‰ to 33‰ for petroleum-derived fuels and methane, respectively. Fuel-like standards were developed and tested using direct-injection elemental analyzer (EA) IRMS for liquid fuels. This method was compared with the published methods, yielding statistically similar results. Four blend curve sets were produced ranging from 0% to 100% of a fuel containing biogenic carbon, focusing on 0% to 10% biogenic carbon. Linear fits were the most applicable for two of the four blend curve sets; however, two sets were found to exhibit slightly quadratic behavior, which was more pronounced in low biogenic blend samples, necessitating second-order fits. The origin of the slight quadratic behavior remains unclear; however, the discussion points to possible interpretations. CanmetENERGY thoroughly characterized a majority of the samples using one- and two-dimensional gas chromatography (GC and GC×GC, respectively) and other analyses. Selected samples were subjected to solid phase extraction (SPE) for saturate, olefin, aromatic, and polar (SOAP) analysis, and the resulting solvent-diluted fractions containing saturates and aromatics were returned to Pacific Northwest National Laboratory (PNNL), where the solvent was removed via evaporation or physical separation using GC techniques. Characterization and separations provided an understanding of saturate and aromatic content, as well as boiling point ranges for each sample and sample fraction. Samples resulting from SPE were examined using EA-IRMS and gas chromatography combustion IRMS (GC-C-IRMS) analyses. Both approaches suggest that the range in values between end-members can be increased by selecting the paraffinic or aromatic fraction of the end-member or by selecting among individual compounds resulting from GC separation of the paraffinic fractions. Considerable work remains to put these approaches into practice and statistically validate the benefit for using a fraction or individual compound over bulk analysis of a sample. However, initial results suggest that separations provide advantages for samples having blend ratios of less than 10% biogenic blendstocks. 13 C results showed statistically similar biofuel blend results to those obtained at PNNL, although additional work is needed to obtain better reproducibility. Select samples were sent to Los Alamos National Laboratory (LANL) for IRMS measurements and Beta Analytics for AMS measurements. This work suggests that IRMS and AMS yield closely comparable results and in some circumstances, IRMS could serve as a surrogate for AMS. While additional work is needed to better resolve statistical advantages for separations and better show the comparable nature of IRMS and AMS in both the biogenic carbon analysis of bulk chemical classes, initial results from this study suggest that these should be pursued in order to proliferate this approach for quantifying biogenic carbon in transportation fuels to the refinery level, thereby potentially enabling process optimization in co-processing scenarios.

09 BIOMASS FUELS↗

Preliminary investigation of an uncertainty budget for uranium isotope ratio analysis using a liquid sampling—atmospheric pressure glow discharge—orbitrap mass spectrometer system

The liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source has proven to be an effective analysis tool for making uranium isotope ratio measurements when coupled to high-resolution mass spectrometers, such as the Orbitrap. While previous studies have shown the capabilities of the LS-APGD for isotope ratio determination, a systematic evaluation of the measurement uncertainty of the technique has not been conducted. To this end, the International Standards Organizations (ISO) guidelines to the expression of uncertainty in measurement (GUM analysis) have been applied to generate an uncertainty budget. For this work, a preliminary assessment derived from the GUM analysis was performed. The uncertainty in the instrument blank determination has been identified as a primary factor contributing to measurement uncertainty for the LS-APGD-Orbitrap method. These findings for the specific test case of uranium isotopic analysis will be invaluable in applications across the breadth of isotope ratio mass spectrometry performed on this unique instrumental platform.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Faraday detector uranium isotope ratio measurement: Insights from solution- and laser ablation-based sampling methodologies on the Neoma MC-ICP-MS

In this study we utilize an all-faraday cup detector configuration on the Neoma MC-ICP-MS to perform uranium isotope ratio determinations from certified reference materials and a nuclear fuel precursor material via solution and laser ablation based sampling methodologies. The goal in performing these measurements is primarily to demonstrate that the all-faraday cup method can produce highly precise and accurate isotope ratios even at relatively low signal intensity levels while also developing a preliminary understanding of how the complex interplay between different amplifier resistor levels (e.g. 10 11 vs 10 13 Ω) and integration times impacts the precision and accuracy of different types of measurements. Our results show that the faraday cups with 1013 Ω resistors in their amplifier feedback loops can be used to produce accurate and relatively precise isotope ratios for ion beams down to ~5 K cps. However, at the lower end of the signal intensities observed in this study, longer integration times are necessary to mitigate the impact of ion beam instability that can occur during laser ablation based sampling. Despite this potential limitation, the all-faraday cup method is highly versatile as exemplified by the analysis of a collection of uranium reference materials with highly variable uranium isotopic compositions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The interstellar Li-7/Li-6 isotope ratio toward Zeta Ophiuchi and Zeta Persei

High S/N, high-resolution observations of the interstellar Li absorption lines toward the stars Zeta Ophiuchi and Zeta Persei are reported. Li I line profiles indicate the presence of both the Li-7 and Li-6 doublets in these two sightlines. Best-fit values for the interstellar Li-7/Li-6 isotope ratio are 6.8 (+1.4/-1.7) towards Zeta Ophiuchi and 5.5 (+ 1.3/-1.1) toward Zeta Persei. Measurement of 6.8 (+1.4/-1.7) for the interstellar Li-7/Li-6 isotope ratio towards Zeta Ophiuchi does not support the lower limit of 25 determined by Ferlet and Dennefeld (1984). The current value of the interstellar Li-7/Li-6 isotope ratio is the result of various lithium production and destruction processes involving stars, cosmic rays, and the big bang.

Meyer, David M.↗

Probing the Atmospheric Cl Isotopic Ratio on Mars: Implications for Planetary Evolution and Atmospheric Chemistry

Following the recent detection of HCl in the atmosphere of Mars by ExoMars/Trace Gas Orbiter, we present here the first measurement of the 37Cl/35Cl isotopic ratio in the Martian atmosphere using a set of NOMAD observations. We determine an isotopic anomaly of -6 ±78‰ compared to Earth standard, consistent with the -51‰ to -1‰ measured on Mars’ surface by Curiosity. The measured isotopic ratio is also consistent with surface measurements, and suggests that Cl reservoirs may have undergone limited processing since formation in the Solar Nebula. The examination of possible sources and sinks of HCl shows only limited pathways to short-term efficient Cl fractionation and many plausible reservoirs of “light” Cl.

Exomars NOMAD↗

Along-strike magma mixing beneath mid-ocean ridges - Effects on isotopic ratios

The effects of mixing processes on the isotopic variability of midocean ridge basalts are studied. The processes considered are porous flow dispersion and convective mixing in magma chambers. Porous flow dispersion is capable of mixing magmas over distances of only a few tens of meters. Convective mixing, on the other hand, is found to produce continuous magma chambers, where mixing is limited by convective processes, and for discontinuous chambers, where mixing is limited by chamber size. Preliminary comparison of the calculations with observations along the midocean ridges shows that the calculations are consistent with the existence of a correlation between bathymetry and isotopic ratio at long, but not at short, wavelengths. They are also capable of explaining a decrease in isotopic variability with increasing spreading rate.

Kenyon, P. M.↗

A Unified Interpretation of Variability in Precipitation Isotope Ratios

Abstract Several mechanisms have been proposed to explain why the isotope ratios of precipitation vary in space and time and why they correlate with other climate variables like temperature and precipitation. Here, we argue that this behavior is best understood through the lens of radiative transfer, which treats the depletion of atmospheric vapor transport by precipitation as analogous to the attenuation of light by absorption or scattering. Building on earlier work by Siler et al., we introduce a simple model that uses the equations of radiative transfer to approximate the two-dimensional pattern of the oxygen isotope composition of precipitation ( δ p ) from monthly mean hydrologic variables. The model accurately simulates the spatial and seasonal variability in δ p within a state-of-the-art climate model and permits a simple decomposition of δ p variability into contributions from gradients in evaporation and the length scale of vapor transport. Outside the tropics, δ p is mostly controlled by gradients in evaporation, whose dependence on temperature explains the positive correlation between δ p and temperature (i.e., the temperature effect). At low latitudes, δ p is mostly controlled by gradients in the transport length scale, whose inverse relationship with precipitation explains the negative correlation between δ p and precipitation (i.e., the amount effect). This suggests that the temperature and amount effects are both mostly explained by the variability in upstream rainout, but they reflect distinct mechanisms governing rainout at different latitudes. Significance Statement The isotopic composition of precipitation has long been used to make inferences about past climates based on its observed relationship with precipitation in the tropics and with temperature at higher latitudes. These relationships—known as the “amount effect” and “temperature effect,” respectively—have been attributed to many different mechanisms, most of which are thought to operate at either high or low latitudes but not both. Here, we present a unified framework for interpreting the isotope variability that can explain the latitude dependence of the temperature and amount effects despite making no distinction between high and low latitudes. Although our results are generally consistent with certain interpretations of the amount effect, they suggest that the temperature effect is widely misunderstood.

54 ENVIRONMENTAL SCIENCES↗

13CO2/12CO2 isotopic ratio measurements using a difference frequency-based sensor operating at 4.35 micrometers

A portable modular gas sensor for measuring the 13C/12C isotopic ratio in CO2 with a precision of 0.8%(+/-1 sigma) was developed for volcanic gas emission studies. This sensor employed a difference frequency generation (DFG)-based spectroscopic source operating at 4.35 micrometers (approximately 2300 cm-1) in combination with a dual-chamber gas absorption cell. Direct absorption spectroscopy using this specially designed cell permitted rapid comparisons of isotopic ratios of a gas sample and a reference standard for appropriately selected CO2 absorption lines. Special attention was given to minimizing undesirable precision degrading effects, in particular temperature and pressure fluctuations.

NASA Discipline Life Sciences Technologies↗

High-precision measurement of U-Pu-Np-Am concentrations and isotope ratios in environmental reference materials by mass spectrometry

Herein, we report results of precise and sensitive mass spectrometric measurements of uranium, plutonium, neptunium, and americium concentrations and isotope ratios in a variety of environmental reference materials. Most of our work has been done on NIST SRM 4350b, River Sediment, but we also present results for NIST SRM 4354, Lake Sediment; NIST SRMs 4355 and 4355a, Peruvian Soil; NIST SRM 4357, Ocean Sediment; NIST SRM 1648a, Urban Particulate Material; NIST SRM 1649b, Urban Dust; IAEA CRM 385, Ocean Sediment; USGS BCR-2, Columbia River Basalt; and USGS BHVO-2, Hawaiian Volcanic Observatory Basalt. These materials reflect a wide range in long-lived actinide concentrations (e.g. 1E4 to 1E10 atoms 239 Pu/g) and isotope ratios. Measurements were performed in a clean laboratory by isotope dilution, multi-collector thermal ionization and multi-collector inductively coupled plasma mass spectrometry. In general, our results are in agreement with, but lower the uncertainty of, literature or certificate values for these reference materials. Our uranium results for the basalts also confirm previously reported high-precision mass spectrometric results from our laboratory. In many cases our measurements of U-Pu-Np-Am nuclides appear to be novel.

58 GEOSCIENCES↗

Isotope Ratio Monitoring Gas Chromatography Mass Spectrometry (IRM-GCMS)

On Earth, the C-13 content of organic compounds is depleted by roughly 13 to 23 permil from atmospheric carbon dioxide. This difference is largely due to isotope effects associated with the fixation of inorganic carbon by photosynthetic organisms. If life once existed on Mars, then it is reasonable to expect to observe a similar fractionation. Although the strongly oxidizing conditions on the surface of Mars make preservation of ancient organic material unlikely, carbon-isotope evidence for the existence of life on Mars may still be preserved. Carbon depleted in C-13 could be preserved either in organic compounds within buried sediments, or in carbonate minerals produced by the oxidation of organic material. A technique is introduced for rapid and precise measurement of the C-13 contents of individual organic compounds. A gas chromatograph is coupled to an isotope-ratio mass spectrometer through a combustion interface, enabling on-line isotopic analysis of isolated compounds. The isotope ratios are determined by integration of ion currents over the course of each chromatographic peak. Software incorporates automatic peak determination, corrections for background, and deconvolution of overlapped peaks. Overall performance of the instrument was evaluated by the analysis of a mixture of high purity n-alkanes of know isotopic composition. Isotopic values measured via IRM-GCMS averaged withing 0.55 permil of their conventionally measured values.

Freeman, K. H.↗

Factors controlling precision and accuracy in isotope-ratio-monitoring mass spectrometry

The performance of systems in which picomole quantities of sample are mixed with a carrier gas and passed through an isotope-ratio mass spectrometer system was examined experimentally and theoretically. Two different mass spectrometers were used, both having electron-impact ion sources and Faraday cup collector systems. One had an accelerating potential of 10kV and accepted 0.2 mL of He/min, producing, under those conditions, a maximum efficiency of 1 CO2 molecular ion collected per 700 molecules introduced. Comparable figures for the second instrument were 3 kV, 0.5 mL of He/min, and 14000 molecules/ion. Signal pathways were adjusted so that response times were <200 ms. Sample-related ion currents appeared as peaks with widths of 3-30 s. Isotope ratios were determined by comparison to signals produced by standard gases. In spite of rapid variations in signals, observed levels of performance were within a factor of 2 of shot-noise limits. For the 10-kV instrument, sample requirements for standard deviations of 0.1 and 0.5% were 45 and 1.7 pmol, respectively. Comparable requirements for the 3-kV instrument were 900 and 36 pmol. Drifts in instrumental characteristics were adequately neutralized when standards were observed at 20-min intervals. For the 10-kV instrument, computed isotopic compositions were independent of sample size and signal strength over the ranges examined. Nonlinearities of <0.04%/V were observed for the 3-kV system. Procedures for observation and subtraction of background ion currents were examined experimentally and theoretically. For sample/ background ratios varying from >10 to 0.3, precision is expected and observed to decrease approximately 2-fold and to depend only weakly on the precision with which background ion currents have been measured.

NASA Discipline Exobiology↗

Carbon isotopic ratios in some low-delta N-15 lunar breccias

Lunar soil breccias 10018, 79035 and 79135 were analyzed for carbon and nitrogen contents and isotopic compositions by vacuum pyrolysis, with a 500 C pre-combustion step in some cases. The combustion was used to remove carbon of terrestrial origin. Nitrogen isotopic ratios for the breccias are very low and are in agreement with results in the literature. Nitrogen yields in two cases were lower than literature values, a result attributable to heterogeneous mixing of implanted and implantation-free components in the breccias. Carbon isotopic ratios were found to be low in these breccias, even when reasonable account is taken of terrestrial carbon contamination. The results are consistent with the idea that low-delta N-15 values in lunar soils and breccias are accompanied by low-delta C-13 values, and imply that any secular variation which occurred in the delta N-15 of nitrogen implanted in lunar soils was accompanied by a similar but smaller variation in the delta C-13 of implanted carbon.

Becker, R. H.↗

Atmospheric Trace Gas Abundances and Stable Isotope Ratios via IR-LIF

We propose to develop new technologies with support provided by PIDDP that will enable the in situ measurements of abundances and stable isotope ratios in important radiatively and biogenically active gases such as carbon dioxide, carbon monoxide, water, methane, nitrous oxide, and hydrogen sulfide to very high precision (0.1 per mil or better for the isotopic ratios, for example). Such measurements, impossible at present, could provide pivotal new constraints on the global (bio)geochemical budgets of these critical species, and could also be used to examine the dynamics of atmospheric transport on Mars, Titan, and other solar system bodies. We believe the combination of solid state light sources with imaging of the IR laser induced fluorescence (IR-LIF) via newly available detector arrays will make such in situ measurements possible for the first time. Even under ambient terrestrial conditions, the LIF yield from vibrational excitation of species such as water and carbon dioxide should produce emission measures well in excess of ten billion photons/sec from samples volumes of order 1 c.c. These count rates can, in principle, yield detection limits into the sub-ppt range that are required for the in situ isotopic study of atmospheric trace gases. While promising, such technologies are relatively immature, but developing rapidly, and there are a great many uncertainties regarding their applicability to in situ IR-LIF planetary studies. We therefore feel PIDDP support will be critical to developing these new tools, and propose a three-year program to combine microchip near-IR lasers with low background detection axes and state-of-the-art HgCdTe detectors developed for astronomical spectroscopy to investigate the sensitivity of IR-LIF under realistic planetary conditions, to optimize the optical pumping and filtering schemes for important species, and to apply the spectrometer to the non-destructive measurement of stable isotopes in a variety of test samples. These studies form the necessary precursors to the development of compact, lightweight stable isotope/trace gas sensors for future planetary missions.

Blake, Geoffrey A.↗