Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Parametric optimization of the liquid sampling-atmospheric pressure glow discharge ionization source coupled to an Orbitrap mass spectrometer for neodymium isotope ratio determinations

Isotope ratio determinations are a valuable tool in several application areas. In nuclear forensics, the isotope ratios of uranium and plutonium are commonly used as a signature for the nuclear material's provenance and processing history. However, signatures from other coexisting elements, such as neodymium and samarium, can offer additional insights. Here, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source coupled to an Orbitrap mass spectrometer (MS) has demonstrated its utility for actinide measurements. This instrumental platform can leverage the high resolution offered by the Orbitrap MS to overcome potential isobaric interferences, such as 144 Nd- 144 Sm, 148 Nd- 148 Sm, and 150 Nd- 150 Sm pairs. The work presented herein demonstrates the rapid, accurate, and precise determination of the isotope ratios for neodymium using the LS-APGD/Orbitrap MS. Both the LS-APGD and Orbitrap MS parameters were optimized systematically, with NdO + found to be the most abundant, most reduced species after applying the optimal collision-induced dissociation modalities. A limit of detection of 3 pg of 142 Nd was achieved when data was acquired and processed using the FTMS Booster, an external data acquisition and processing system offered by Spectroswiss. Excellent accuracy of better than 99 % and precision of <1 % RSD were achieved when a solution of the well-characterized neodymium standard (JNdi-1 standard) was analyzed under the optimized condition, indicating the LS-APGD/Orbitrap's great potential for isotope ratio analysis of Nd and other REEs for diverse applications.

47 OTHER INSTRUMENTATION↗

Weathering Incongruence in Mountainous Mediterranean Climates Recorded by Stream Lithium Isotope Ratios

Lithium isotope ratios (δ 7 Li) of rivers are increasingly serving as a diagnostic of the balance between chemical and physical weathering contributions to overall landscape denudation rates. Here, we show that intermediate weathering intensities and highly enriched stream δ 7 Li values typically associated with lowland floodplains can also describe small upland watersheds subject to cool, wet climates. This behavior is revealed by stream δ 7 Li between +22.4 and +23.5‰ within a Critical Zone observatory located in the Cévennes region of southern France, where dilute stream solute concentrations and significant atmospheric deposition otherwise mask evidence of incongruence. The water-rock reaction pathways underlying this behavior are quantified through a multicomponent, isotope-enabled reactive transport model. Using geochemical characterization of soil profiles, bedrock, and long-term stream samples as constraints, we evolve the simulation from an initially unweathered granite to a steady state weathering profile which reflects the balance between (a) fluid infiltration and drainage and (b) bedrock uplift and soil erosion. Enriched stream δ 7 Li occurs because Li is strongly incorporated into actively precipitating secondary clay phases beyond what prior laboratory experiments have suggested. Chemical weathering incongruence is maintained despite relatively slow reaction rates and moderate clay accumulation due to a combination of two factors. First, reactive primary mineral phases persist across the weathering profile and effectively “shield” the secondary clays from resolubilization due to their greater solubility. Second, the clays accumulating in the near-surface profile are relatively mature weathering byproducts. These factors promote characteristically low total dissolved solute export from the catchment despite significant input of exogenous dust.

54 ENVIRONMENTAL SCIENCES↗

Source indicators of humic substances and proto-kerogen - Stable isotope ratios, elemental compositions and electron spin resonance spectra

Stable isotope ratios of C, N and H, elemental compositions, and electron spin resonance (ESR) data of humic acids and proto-kerogens from twelve widely varying sampling locations are presented. Humic acids and proto-kerogens from algal sources are more aliphatic and higher in N than those from higher plant sources. Oxygen content appears to represent a measure of maturation, even in Recent sediments, and S content may reflect redox conditions in the environment of deposition. The ESR data indicate that the transformation of humic substances to proto-kerogens in Recent sediments is accompanied by an increase in aromatic character. A combination of stable carbon isotope ratio and H/C ratio may be a simple but reliable source indicator which allows differentiation of marine-derived from terrestrially-derived organic matter. The stable nitrogen isotope ratios are useful indicators of nitrogen nutrient source. Deuterium/hydrogen isotope ratios appear to reflect variations in meteoric waters and are not reliable source indicators.

Stuermer, D. H.↗

Measuring Isotope Ratios Across the Solar System

Stable isotope ratios in C, H, N, O and S are powerful indicators of a wide variety of planetary geophysical processes that can identify origin, transport, temperature history, radiation exposure, atmospheric escape, environmental habitability and biology [1]. For the Allan Hills 84001 meteorite, for example, the (sup 1)(sup 3)C/(sup 1)(sup 2)C ratio identifies it as a Mars (SNC) meteorite; the ??K/??Ar ratio tells us the last time the rock cooled to solid, namely 4 Gya; isotope ratios in (sup 3)He, (sup 2)(sup 1)Ne and (sup 3)?Ar show it was in space (cosmic ray exposure) for 10-20 million years; (sup 1)?C dating that it sat in Antarctica for 13,000 years before discovery; and clumped isotope analysis of (sup 1)?O(sup 1)(sup 3)C(sup 1)?O in its carbonate that it was formed at 18+/-4 ?C in a near-surface aqueous environment [2]. Solar System Formation

planetary geophysical process↗

Using Separation-Enhanced Isotope Ratio Mass Spectrometry

Stable isotope ratio measurements using IRMS have been shown by LANL to be effective for tracking co-processed biogenic carbon, with results approaching that of AMS. The lower cost of an IRMS may enable deployment to refineries improving access and analysis turnaround times (≤ 2-hours), and by extension data that can allow process optimization to maximize renewable carbon in desired refinery products. This work will apply chemical separation approaches as part of the IRMS analyses, enabling biogenic carbon tracking in fuel product streams by boiling point range, by chemical class, or even by compound. This work will show IRMS to be at a minimum as reliable and comparable to AMS, by using separations to improve sensitivity at low blend ratios and enable refinery process optimization through onsite analysis.

36 MATERIALS SCIENCE↗

Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

Particle analysis has benefitted from the advent of single particle inductively coupled plasma-mass spectrometry (spICP-MS) due to its robustness, sensitivity, and high-throughput nature. Previous methods of spICP-MS have typically utilized quadrupole or time-of-flight mass analyzers and therefore employ electron multiplier-based detectors (such as secondary electron multipliers or microchannel plates). However, to obtain precise measurements on elemental or isotopic ratios within individual particles, multi-collector ICP-MS (MC-ICP-MS) can be used. Here, we investigate Ce isotope ratios, specifically 142 Ce/ 140 Ce, by spMC-ICP-MS using an all-Faraday cup collector array. Using 1 μm (diameter) cerium dioxide particles, integration times of the Faraday cup detectors were varied from 50–500 ms. The signal from the cerium isotopes in the particles was used to determine isotope ratios, which closely matched the expected natural isotopic abundances. Due to the signal decay response from the Faraday cups, the signal from particles lasts much longer than the expected 1–2 ms (up to 100 s of ms). To explore this effect on isotope ratio analysis, multiple ratio analysis methods were used to determine how to obtain optimal precision and accuracy. Relative differences were around 2% for methods that calculated isotope ratios from summing the total signal of an individual particle before calculating the ratio (rather than using every data point individually). It was found that summing all data points per particle, or integrating under the signal peak, yielded both accurate and precise isotope ratios within the particle population. Particles were also sampled off a solid substrate via microextraction, and isotope ratios were determined with relative differences of 0.13% to 9%. This demonstrates the ability to use spMC-ICP-MS to obtain isotope ratios on particles, with little to no relative difference in comparison to the expected ratio, even when operating Faraday detectors at fast 50 ms integration times.

Szakas, Sarah E. [Oak Ridge National Laboratory (O↗

A model composition for Mars derived from the oxygen isotopic ratios of martian/SNC meteorites

Oxygen is the most abundant element in most meteorites, yet the ratios of its isotopes are seldom used to constrain the compositional history of achondrites. The two major achondrite groups have O isotope signatures that differ from any plausible chondritic precursors and lie between the ordinary and carbonaceous chondrite domains. If the assumption is made that the present global sampling of chondritic meteorites reflects the variability of O reservoirs at the time of planetessimal/planet aggregation in the early nebula, then the O in these groups must reflect mixing between known chondritic reservoirs. This approach, in combination with constraints based on Fe-Mn-Mg systematics, has been used previously to model the composition of the basaltic achondrite parent body (BAP) and provides a model precursor composition that is generally consistent with previous eucrite parent body (EPB) estimates. The same approach is applied to Mars exploiting the assumption that the SNC and related meteorites sample the martian lithosphere. Model planet and planetesimal compositions can be derived by mixing of known chondritic components using O isotope ratios as the fundamental compositional constraint. The major- and minor-element composition for Mars derived here and that derived previously for the basaltic achondrite parent body are, in many respects, compatible with model compositions generated using completely independent constraints. The role of volatile elements and alkalis in particular remains a major difficulty in applying such models.

Delaney, J. S.↗

Radioactive halos and ion microprobe measurement of Pb isotope ratios

This investigation was to obtain, if possible, the Pb isotope ratios of both lunar and meteoritic troilite grains by utilizing ion microprobe techniques. Such direct in situ measurement of Pb isotope ratios would eliminate contamination problems inherent in wet chemistry separation procedures, and conceivably determine whether lunar troilite grains were of meteoritic origin. For comparison purposes two samples of meteoritic troilite were selected (one from Canyon Diablo) for analysis along with two very small lunar troilite grains (approximately 50-100 microns). It was concluded that the ion microprobe as presently operating, does not permit the in situ measurement of Pb isotope ratios in lunar or meteoritic troilite. On the basis of these experiments no conclusions could be drawn as to the origin of the lunar troilite grains.

Gentry, R. V.↗

Refining a Novel Process Monitoring Method to Safeguard Continuously Cycling Designs Using Isotopic Ratios

In advanced reactor (AR) designs, a common feature is continuous chemical processing and circulation of the nuclear material. This work bridges a significant measurement gap in safeguarding reactors with circulating fuel or continuous refueling by leveraging and building on the isotope ratio method first developed by our team under an FY21 Advanced Reactors International Safeguards Engagement (ARISE) project (Uribe et al. 2021). In circulating fuel designs, the radioisotope inventory changes from traditional effects (e.g., radioactive decay, fission) but also includes material transport due to pressure and temperature gradients. Such designs may also require regular or continuous additions or removals during operation, which significantly increases the rate of inventory change compared to traditional pressurized water reactor (PWR)s. Thus, directly tracking the nuclear inventory is ineffective since the isotopes are continuously added and removed. The isotope ratio method instead focuses on detecting changes to the input and output flows of radioisotopes. Previous work showed that for well-chosen pairs of isotopes, the isotopic ratio provides a sensitive and lasting indicator of deviation from normal conditions (e.g., startup, shutdown, diversion). The isotope ratio method is a process monitoring method with potential for application in for forward-looking approaches to International Atomic Energy Agency (IAEA) safeguards. The original process monitoring method was developed for a specific case—the decay tank of a thorium-fueled molten salt breeder reactor. In this expanded work, we explored other types of reactors and processes with nonstationary (e.g., flowing) nuclear material, which are difficult to safeguard with traditional methods because of the transient nature of the systems. The goal of the present work is to generalize the isotope ratio method for use in processes with continuously flowing nuclear material. All continuous processes have an average time for isotopes to be replaced in the system. The isotope ratio method works by choosing radioisotopes with half-lives both above and below the processing time. The present work seeks to explore which isotopes are suitable for the method by simulating the nuclear inventory, radioisotope emissions, and detector responses for several classes of advanced reactors. While the method can in principle be applied to other processes (e.g., enrichment or reprocessing facilities), the present work limits scope to ARs with continuously flowing fuel. Section 2 details the mathematics supporting the isotope ratio method, and Section 3 introduces the representative ARs selected for this work. Section 4 discusses how each reactor was analyzed, and Section 5 showcases the results for each representative reactor. Finally, Section 6 provides concluding remarks and suggests pathways for further analysis.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Novel Framework for Quantifying past Methane Recycling by Sphagnum-Methanotroph Symbiosis Using Carbon and Hydrogen Isotope Ratios of Leaf Wax Biomarkers

The concentration of atmospheric methane is strongly linked to variations in Earth's climate. Currently, we can directly reconstruct the total atmospheric concentration of methane, but not individual terms of the methane cycle. Northern wetlands, dominated by Sphagnum, are an important contributor of atmospheric methane, and we seek to understand the methane cycle in these systems. We present a novel method for quantifying the proportion of carbon Sphagnum assimilates from its methanotrophic symbionts using stable isotope ratios of leaf-wax biomarkers. Carbon isotope ratios of Sphagnum compounds are determined by two competing influences, water content and the isotope ratio of source carbon. We disentangled these effects using a combined hydrogen and carbon isotope approach. We constrained Sphagnum water content using the contrast between the hydrogen isotope ratios of Sphagnum and vascular plant biomarkers. We then used Sphagnum water content to calculate the carbon isotope ratio of Sphagnum's carbon pool. Using a mass balance equation, we calculated the proportion of recycled methane contributed to the Sphagnum carbon pool, 'PRM.' We quantified PRM in peat monoliths from three microhabitats in the Mer Bleue peatland complex. Modern studies have shown that water table depth and vegetation have strong influences on the peatland methane cycle on instrumental time scales. With this new approach, delta C-13 of Sphagnum compounds are now a useful tool for investigating the relationships among hydrology, vegetation, and methanotrophy in Sphagnum peatlands over the time scales of entire peatland sediment records, vital to our understanding of the global carbon cycle through the Late Glacial and Holocene.

air pollution↗

Natural Abundance Isotope Ratio Measurements of Organic Molecules Using 21 T FTICR MS

Subtle variations in stable isotope ratios at natural abundance are challenging to measure but can yield critical insights into biological, physical, and geochemical processes. Well established methods, particularly multi-collector, gas-source or plasma isotope ratio mass spectrometry (IRMS) are the gold standard for stable isotope measurement but inherent limitations in these approaches make them ill-suited to determining site-specific and multiply substituted isotopic abundances of all but a few compounds, or to characterizing mixtures or larger intact molecules. Additionally, Fourier transform mass spectrometry (FTMS), namely Orbitrap mass spectrometry, has recently demonstrated the ability to measure natural abundance isotope ratios with chemically informative accuracy and precision. Here, we report the first use of Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) for the accurate (<1‰) and precise (<1‰ standard error) simultaneous determination of $δ$ 13 C and $δ$ 15 N in caffeine isotopologues and provide a discussion of the critical instrumental parameters necessary to make such measurements. Finally, we report the ability to make these measurements with online liquid chromatography, expanding the ability of this technique to explore mixtures in the future.

07 ISOTOPE AND RADIATION SOURCES↗

Investigation of potential polyatomic interferences on uranium isotope ratio measurements for the LS-APGD-Orbitrap MS system

The determination of actinide (e.g., U and Pu) content and isotopics is of importance to the nuclear forensics and safeguards communities. However, in the analysis of environmental samples, such as those collected by the International Atomic Energy Agency, uranium measurements can be complicated by isobaric interferences from polyatomic variants of heavy elements (e.g., Pb). This leads to complex, time-consuming sample manipulations (i.e., separations) before determining isotope ratios. An alternative strategy to sample pretreatment is to use high-resolution mass spectrometric platforms during the analysis to fully resolve the uranium isotopes from potential polyatomic interferences, negating the need for prior chemical separation. The liquid sampling - atmospheric pressure glow discharge (LS-APGD) coupled with an Orbitrap mass spectrometer provides a high-resolution (>70,000 m/Δm at m/z 200) inorganic mass spectrometry platform. Further, as a demonstration of the power of this instrumental platform, and indeed, the high-resolution approach in general, uranium isotope ratios were determined in the presence of elemental impurities (e.g., Pb, Pt, Ta, W) commonly encountered with environmental sample swipe analysis, without any prior treatment. Even at elemental impurity concentrations of 1000–5000× relative to uranium, no interference was observed with the 235 U or 238 U signal. In addition, the 235 U/ 238 U isotope ratio for the samples with the concomitants present are within 2 standard deviations of the values obtained without their addition, indicating that these impurities do not impact the determined uranium isotope ratio. These findings represent a significant first step in leveraging the high resolution of the LS-APGD-Orbitrap-MS to overcome isobaric and molecular interferences instead of relying on chemical separations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Are sulfur isotope ratios sufficient to determine the antiquity of sulfate reduction

Possible limitations on the use of sulfur isotope ratios in sedimentary sulfides to infer the evolution of microbial sulfate reduction are discussed. Current knowledge of the ways in which stable sulfur isotope ratios are altered by chemical and biological processes is examined, with attention given to the marine sulfur cycle involving various microbial populations, and sulfur reduction processes, and it is noted that satisfactory explanations of sulfur isotope ratios observed in live organisms and in sediments are not yet available. It is furthermore pointed out that all members of the same genus of sulfate reducing bacteria do not always fractionate sulfur to the same extent, that the extent of sulfur fractionation by many sulfate-reducing organisms has not yet been determined, and that inorganic processes can also affect sulfur isotope fractionation values. The information currently available is thus concluded to be insufficient to determine the time of initial appearance of biological sulfate reduction.

Ashendorf, D.↗

Hollow fiber mid-ID spectrometer with UV laser ablation sampling for fine spatial reoslution of isotope ratios in solids

We describe a system that combines isotope ratio analysis via mid-infrared (Mid-IR) laser absorption spectroscopy with fine spatial resolution sampling using a UV pulsed laser. The UV laser ablates a pit in a solid on the order of 10 microns in diameter. The sample-derived particulates resulting from laser ablation pass through a micro-combustor, and the resulting gas is analyzed using Mid-IR laser absorption spectroscopy in a capillary absorption spectrometer (CAS). The CAS uses a hollow fiber optic waveguide with a reflective inner coating and a small internal volume on the order of 1ml. The hollow fiber both guides the laser light from source to detector and contains the gas sample at reduced pressure. Near unity overlap between the laser beam and sample enables sensitive analysis with ultra-small sample size. A prototype system has been demonstrated to enable stable carbon isotopic analysis (d13C) with 1 per mil precision using <1 picomole of carbon and is currently being used to study nutrient exchange in soil/root/microbial rhizosphere studies. The smaller sample size of this system is enabling fine spatial resolution analysis (on the order of 10 microns), which is roughly an order of magnitude smaller than was possible with an isotope ratio mass spectrometer (IRMS). In addition to rhizosphere studies, the system can provide a useful tool for fine scale isotope analysis with applications in biological, forensic, and environmental science.

capillary absorption spectroscopy, laser ablation,↗

Development and Airborne Operation of a Compact Water Isotope Ratio Infrared Spectrometer

A sensitive laser spectrometer, named IRIS (water isotope ratio infrared spectrometer), was developed for the in situ detection of the isotopic composition of water vapour in the upper troposphere and the lower stratosphere. Isotope ratio measurements can be used to quantify troposphere stratosphere exchange, and to study the water chemistry in the stratosphere. IRIS is based on the technique of optical feedback cavity-enhanced absorption spectroscopy. It uses a room temperature near-infrared laser, and does not require cryogenic cooling of laser or detectors. The instrument weighs 51 kg including its support structure. Airborne operation was demonstrated during three flights aboard the European M55-Geophysica stratospheric research aircraft, as part of the AMMA/SCOUT-03 (African Monsoon Multidisciplinary Analysis/Stratospheric Climate links with emphasis on the Upper Troposphere and lower stratosphere) campaign in Burkina Faso in August 2006. The data are discussed with reference to a Rayleigh distillation model. As expected, there is no indication of non-mass-dependent fractionation (also known as mass-independent fractionation) in the troposphere. Furthermore, improvements to the thermal management system and a move to a (cryogen-free) longer-wavelength laser source are discussed, which together should result in approximately two orders of magnitude improvement of the sensitivity

Iannone, Rosario Q.↗

How numerical tracers and water isotope ratios help us better understand the hydrological cycle and its representation in Earth system models [Slides]

Outline: Water isotope ratios and fractionation; Isotope tracers in Earth system models; Generalized "process-oriented" water tracers in Earth system models; Opportunities in E3SM. Water isotope ratio data are rapidly becoming more available, providing a critical link between models and observations, as well as providing new opportunities to improve process representations (e.g., T/ET partitioning, cloud processes, partitioning of streamflow, coastal or urban impacts on hydrology, etc.)

54 ENVIRONMENTAL SCIENCES↗