CSTT Update: Fuel Quality Analyzer

Presentation summary: A Nafion® based, electrochemical hydrogen contaminant detector was tested at H2Frontier hydrogen filling station in Burbank CA during its refit and recommissioning.; A 100 sccm sample was taken from the H2F production skid and without requiring humidification; both real-time product gas and storage gas was sampled. The selfhumidifying approach using an internal reservoir worked with minimal baseline drift.; The LANL HCD easily detected CO byproduct during reformer restart (as high as 18ppm) and 11, 1ppm challenges were performed during an 850h experiment after initial installation and 10ppm testing/commissioning.; The 10ppm and 1ppm challenges produced ≈ 75% and ≈ 60% reductions in pumping current respectively. Twelve, 1ppm challenges decreased pumping current on average of 59.5% with an error of ±1.4% over 12 challenges during a 6 month time period.; Long term baseline data show a drift rate of 9x10- 7 A/h over a 600h period of testing. The addition of a 1.5V, 600s pulse approximately once a day eliminated any long term drift.; No false positives or false negatives were seen during the field tests to date.; Average water consumption rate is estimated to be ~250μl/day at 100sccm.; Project milestones successfully met.

08 HYDROGEN↗

Novel gas exposure system for the controlled exposure of plants to gaseous hydrogen fluoride

Abstract Plants can serve as sensitive bioindicators of the presence of contaminant vapors in the atmosphere. This work describes a novel laboratory-based gas exposure system capable of calibrating plants as bioindicators for the detection and delineation of the atmospheric contaminant hydrogen fluoride (HF) as a preparatory step for monitoring release emissions. To evaluate changes in plant phenotype and stress-induced physiological effects attributed to HF alone, the gas exposure chamber must have additional controls to simulate otherwise optimal plant growth conditions including variables such as light intensity, photoperiod, temperature, and irrigation. The exposure system was designed to maintain constant growth conditions during a series of independent experiments that varied between optimal (control) and stressful (HF exposure) conditions. The system was also designed to ensure the safe handling and application of HF. An initial system calibration introduced HF gas into the exposure chamber and monitored HF concentrations by cavity ring-down spectroscopy for a 48-h period. Stable concentrations inside the exposure chamber were observed after approximately 15 h, and losses of HF to the system ranged from 88 to 91%. A model plant species ( Festuca arundinacea ) was then exposed to HF for 48 h. Visual phenotype stress-induced responses aligned with symptoms reported in the literature for fluoride exposure (tip dieback and discoloration along the dieback transition margin). Fluoride concentrations in exposed tissues compared to control tissues confirmed enhanced fluoride uptake due to HF exposure. The system described herein can be applied to other reactive atmospheric pollutants of interest in support of bioindicator research.

54 ENVIRONMENTAL SCIENCES↗

Unexpected Hydride: Ce 4 B 2 C 2 H 2.42 , a Stuffed Variant of the Nd 2 BC Structure Type

Ce 4 B 2 C 2 H 2.42 was grown as large crystals from a cerium/copper eutectic flux. The structure was characterized by single-crystal X-ray and neutron diffraction and was found to be a stuffed variant of Nd 2 BC with the addition of two interstitial hydrogen positions. The tetrahedral hydrogen position is fully occupied, while the octahedral position has an occupancy of 42(3)%. Initial synthesis was due to hydrogen contamination of the cerium metal but has been successfully repeated using anthracene as a carbon and hydrogen source. Density of states calculations suggest that the incorporation of hydrogen stabilizes the compound with respect to the nonhydrided model. Magnetic susceptibility data show a complex magnetic ordering at 7.7 K that originates from the localized electron on the Ce 3+ in the structure. The trivalent state is also supported by X-ray photoelectron spectroscopy measurements. Heat capacity and electrical resistivity data show that the phase transition is broad in temperature, which may be due to structural disorder. Furthermore, the large low temperature value of C/T also indicates possible heavy fermion behavior.

36 MATERIALS SCIENCE↗

Oil-free centrifugal hydrogen compression technology demonstration

One of the key elements in realizing a mature market for hydrogen vehicles is the deployment of a safe and efficient hydrogen production and delivery infrastructure on a scale that can compete economically with current fuels. The challenge, however, is that hydrogen, being the lightest and smallest of gases with a lower viscosity and density than natural gas, readily migrates through small spaces and is difficult to compresses efficiently. While efficient and cost effective compression technology is crucial to effective pipeline delivery of hydrogen, the compression methods used currently rely on oil lubricated positive displacement (PD) machines. PD compression technology is very costly, has poor reliability and durability, especially for components subjected to wear (e.g., valves, rider bands and piston rings) and contaminates hydrogen with lubricating fluid. Even so called “oil-free” machines use oil lubricants that migrate into and contaminate the gas path. Due to the poor reliability of PD compressors, current hydrogen producers often install duplicate units in order to maintain on-line times of 98-99%. Such machine redundancy adds substantially to system capital costs. As such, DOE deemed that low capital cost, reliable, efficient and oil-free advanced compressor technologies are needed. MiTi’s solution is a completely oil-free, multi-stage, high-speed, centrifugal compressor designed for flow capacity of 500,000 kg/day with a discharge pressure of 1200 psig. The design employs oil-free compliant foil bearings and seals to allow for very high operating speeds, totally contamination free operation, long life and reliability. This design meets the DOE’s performance targets and achieves an extremely aggressive, specific power metric of 0.48 kW-hr/kg and provides significant improvements in reliability/durability, energy efficiency, sealing and freedom from contamination. The multi-stage compressor system concept has been validated through full scale performance testing of a single stage with helium similitude gas at full speed in accordance with ASME PTC-10. The experimental results indicated that aerodynamic performance, with respect to compressor discharge pressure, flow, power and efficiency exceeded theoretical prediction. Dynamic testing of a simulated multistage centrifugal compressor was also completed under a parallel program to validate the integrity and viability of the system concept. The results give strong confidence in the feasibility of the multi-stage design for use in hydrogen gas transportation and delivery from production locations to point of use.

08 HYDROGEN↗

Development of a Microwave Regenerative Sorbent-Based Hydrogen Purifier

This paper describes the design and fabrication of a Microwave Regenerative Sorbent-based Hydrogen Purifier (MRSHP). This unique microwave powered technology was developed for the purification of a hydrogen stream produced by the Plasma Pyrolysis Assembly (PPA). The PPA is a hydrogen recovery (from methane) post processor for NASA's Sabatier-based carbon dioxide reduction process. Embodied in the Carbon dioxide Reduction Assembly (CRA), currently aboard the International Space Station (ISS), the Sabatier reaction employs hydrogen to catalytically recover oxygen, in the form of water, from respiratory carbon dioxide produced by the crew. This same approach is base-lined for future service in the Air Revitalization system on extended missions into deep space where resupply is not practical. Accordingly, manned exploration to Mars may only become feasible with further closure of the air loop as afforded by the greater hydrogen recovery permitted by the PPA with subsequent hydrogen purification. By utilizing the well-known high sorbate loading capacity of molecular sieve 13x, coupled with microwave dielectric heating phenomenon, MRSHP technology is employed as a regenerative filter for a contaminated hydrogen gas stream. By design, freshly regenerated molecular sieve 13x contained in the MRSHP will remove contaminants from the effluent of a 1-CM scale PPA for several hours prior to breakthrough. By reversing flow and pulling a relative vacuum the MRSHP prototype then uses 2.45 GHz microwave power, applied through a novel coaxial antenna array, to rapidly heat the sorbent bed and drive off the contaminants in a short duration vacuum/thermal contaminant desorption step. Finally, following rapid cooling via room temperature cold plates, the MRSHP is again ready to serve as a hydrogen filter.

Wheeler, Richard R., Jr.↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

Investigation of the effect of structural defects from hydride precipitation on superconducting properties of high purity SRF cavity Nb using magneto-optical and electron imaging methods

Abstract Nb is an elemental superconductor with a critical temperature of 9.3 K and is widely used to fabricate superconducting radiofrequency (SRF) cavities for particle accelerators. However, microstructural defects in Nb, such as grain boundaries (GBs) and dislocations, can act as pinning centers for magnetic flux that can degrade SRF cavity performance. Hydrogen contamination is also detrimental to SRF cavity performance due to the formation of normal conducting hydrides during cool down. In this study, disc shaped Nb bi-crystals extracted from high-purity large-grain Nb slices were investigated to study the effects of GBs, hydrogen, and dislocations on superconducting properties. Grain orientation and GB misorientation were measured using Laue x-ray diffraction and electron backscattered diffraction (EBSD) analyses. Cryogenic magneto-optical imaging was used to directly observe magnetic flux penetration below T c = 9.3 K. Damage caused by low temperature precipitation of hydrides and their dissolution upon reheating after cryogenic cycles was examined using electron channeling contrast imaging, and EBSD. The relationships between hydride formation, dislocation content, GBs, cryo-cooling, heat treatment (HT), and flux penetration indicate that both GB character and hydrogen content affect magnetic flux penetration. Such flux penetration could be facilitated by dislocation structures and low angle GBs resulting from hydride precipitation and HT.

36 MATERIALS SCIENCE↗

In-situ Radiography of Hydrogen Porosity Growth and Development in Aluminum Welds

In aluminum welding, hydrogen contamination is the main cause of the welding defect, porosity. Porosity in welds can adversely affect the mechanical properties such as tensile strength, fatigue life and ductility. There have been a variety of solutions to help reduce porosity in aluminum welds including finding the source of hydrogen. However, in some cases the amount of hydrogen may be drastically reduced but impossible to completely eliminate. Another approach to this issue is to understand where a pore originates and how it moves and grows within the weld pool. This information may lead to a more innovative method for pore elimination during gas tungsten arc (GTA) welding of aluminum.

42 ENGINEERING↗

Understanding how molecular hydrogen impacts the total dose and dose rate response of linear bipolar circuits

Recent Enhanced Low Dose Rate Sensitivity (ELDRS) investigations carried out by RLP Research, Arizona State University (ASU) and Jet Propulsion Laboratory (JPL) have shown significant differences in the degradation of bipolar micro-circuits with total dose in the presence of molecular hydrogen (H2) in packages. This has a significant impact on radiation hardness assurance and opens up opportunities to improve device performance. The general objectives of this program are to: 1. Determine the extent to which hydrogen contamination affects the total dose and dose rate response of linear bipolar circuits; 2. Develop a model that will enable the prediction of high dose rate (HDR) and low dose rate (LDR) response asymptotes and transition dose rates as a function of total dose, temperature, pressurized hydrogen, defect precursors, and other process dependent variables; 3. Explore the possibility of an accelerated hardness assurance method and possible hardening approaches; and 4. Extend the work to other technologies that have total dose response affected by hydrogen contamination.In this document, we xperimentally demonstrate with test transistors and circuits that hydrogen is correlated with ELDRS in bipolar linear circuits. We show that the amount of hydrogen determines: 1) the total dose response versus dose rate and 2) the transition dose rates between the high and low dose rate responses. The experimental results are supported with a steady state drift/diffusion analytical model as well as modeling calculations using COMSOL Multiphysics.

Pease, Ron↗

Assessment of Electrode Contamination Mitigation at 0.5 MA Scale

The Z Machine at Sandia National Laboratories uses current pulses with peaks up to 27 MA to drive target implosions and generate high energy density conditions of interest for stockpile stewardship programs pertinent to the NNSA program portfolio . Physical processes in the region near the Z Machine target create electrode plasmas which seed parasitic current loss that reduce the performance and output of a Z experiment. Electrode surface contaminants (hydrogen, water, hydrocarbons) are thought to be the primary constituent of electrode plasmas which contribute to loss mechanisms. The Sandia team explore d in situ heating and plasma discharge techniques by integrating requisite infrastructure into Sandia's Mykonos LTD accelerator, addressing potential impacts to accelerator operation, and reporting on the impact of these techniques on electrode plasma formation and shot performance. The in situ discharge cleaning utilizes the electrodes of the accelerator to excite an argon-oxygen plasma to sputter and chemically react contaminants from electrode surfaces. Insulating breaks are required to isolate the plasma in electrode regions where loss processes are most likely to occur. The shots on Mykonos validate that these breaks do not perturb experiment performance, reducing the uncertainty on the largest unknown about the in situ cleaning system. Preliminary observations with electrical and optical diagnostics suggest that electrode plasma formation is delayed, and overall inventory has been substantively reduced. In situ heating embeds cartridge heaters into accelerator electrodes and employs a thermal bakeout to rapidly desorb contaminants from electrode surfaces. For the first time, additively manufactured (AM) electrode assemblies were used on a low impedance accelerator to integrate cooling channels and manage thermal gradients. Challenges with poor supplier fabrication to specifications, load alignment, thermal expansion and hardware movement and warpage appears to have introduced large variability in observed loss, though, preventing strong assertions of loss reduction via in situ heating. At this time, an in situ discharge cleaning process offers the lowest risk path to reduce electrode contaminant inventories on Z, though we recommend continuing to develop both approaches. Additional engineering and testing are required to improve the implementation of both systems. .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Real-Time Detection of Hydrogen and Ammonia Isotopologues for Impurity Removal and Recovery of Tritium

To accommodate gas measurements for impurity removal and recovery of tritium, a silver-coated optical or waveguide is employed for collecting Raman scattered signals to determine relative hydrogen and ammonia isotopologue populations in real time. The data and results presented here demonstrate an analytical methodology for the analysis of four ammonia and three hydrogen isotopologues in a hydrogen–deuterium exchange reaction by gas phase Raman spectroscopy. Standard chemometric modeling techniques effectively unravel the signatures of the isotopologues involved observed here; however, a sophisticated quantum chemical approach supports the spectral assignments. An interpretation of the data presented here can emphasize the practicality and reliability of the gaseous monitoring system in complex chemical environments for the hydrogen fuel economy as well as the more distant energy source from a facility that handles tritium. There are still considerable concerns about the measurement of tritium in isotope separation and radiological impurities from gas processing. A common impurity in gas processing is ammonia, which can form readily in the presence of nitrogen and tritium. Substituted ammonia (NQ 3 ), where Q = H, D, or T, is traditionally removed through getters or diffusers along with other non-hydrogen contaminants. A preferable analytical approach is noninvasive and can be deployed for real-time process evaluation in radiological environments.

Ammonia↗

Heavy Duty Hydrogen: Reference Station, Fueling Performance Test Device Concepts, and Station Capacity Model (CRADA Final Report)

This project will provide valuable information on (1) reference station design, (2) exploration of design concepts for a fueling performance test device, and (3) modeling of station capacity. The work applies to heavy-duty (HD) hydrogen fueling stations with large dispensing capacity and high flowrates servicing HD hydrogen trucks such as class 8 trucks in long haul applications. Additionally, a 4th area will provide near-real-time verification of fuel quality with on-site hydrogen contaminant detectors (HCDs) for use at both light-duty (LD) and HD stations. The work leverages national lab capabilities including staff and equipment at SNL, NLR, and ANL with collaboration and funding cost share from California agencies (CEC, SCAQMD, and GO-Biz). This project will provide tools and information that lead to more efficient design, acceptance, and commissioning of these larger capacity, higher flowrate stations serving HD applications. The HCD work will benefit both LD and HD stations. Note: The 4th area (HCD) mentioned above continued outside of this CRADA and will not be included in this report. There are no tasks included in this CRADA for HCD and the summary text for it should have been removed prior to this CRADA contract execution but remained in error and is included here for completeness.

08 HYDROGEN↗

The equations of state of statically compressed palladium and rhodium

Here, the pressure–volume equations of state of palladium and rhodium statically compressed in neon are presented. Vinet fits give parameters for palladium: V0=58.678(73) Å 3 , B 0 =189.3(30) GPa, B' 0 =5.473(63), and rhodium: V 0 =55.062(63) Å3, B 0 =241.3(65) GPa, B' 0 =5.34(24). Both metals are observed to react with hydrocarbons under pressure to form hydrides. Existing equations of state are discussed with regard to potential inadvertent hydrogen contamination as a source for discrepancies and anomalous fitted parameters.

36 MATERIALS SCIENCE↗

Tensile properties from room temperature to 1315 C of tungsten-lined tantalum-alloy (T-111) tubing fabricated by hot isostatic pressing

The effects were studied of a thin tungsten liner on the tensile properties of T-111 tubing considered for fuel cladding in a space power nuclear reactor concept. The results indicate that the metallurgically bonded liner had no appreciable effects on the properties of the T-111 tubing. A hot isostatic pressing method used to apply the liners is described along with a means for overcoming the possible embrittling effects of hydrogen contamination.

Buzzard, R. J.↗

Chemisorption kinetics of hydrogen on evaporated iron films

An investigation is conducted of the kinetics of isothermal adsorption-desorption processes involving molecular hydrogen which is chemisorbed onto thin (20 to 50 A) polycrystalline Fe films at temperatures near 300 K. The results of the investigation indicate that chemisorption in the H2-Fe system occurs via a precursor state of molecularly adsorbed hydrogen. Contamination of the surface from unknown impurities in the gas phase is found to affect the number of available adsorption sites and to modify the prefactor for the absolute desorption rate constant for the precursor state.

Shanabarger, M. R.↗

Opposed jet burner studies of effects of CO, CO2, and N2 air-contaminants on hydrogen-air diffusion flames

The blowoff/restore characteristics for jets of various H2/N2 mixtures opposed to jets of air contaminated by N2, CO, and CO2 have been determined using a counterflow diffusion flame formed by a tubular opposed jet burner. Both blowoff and restore limits are found to be sensitive to fuel and air composition. Empirically derived variations in the limits of the average mass flux of incoming H2 with percent contaminant, at fixed incoming fuel and H2/O2 inputs, are used to quantify the effects of oxygen dilution, flame augmentation, and flame retardation by N2, CO, and CO2 contaminants. The implications of the results are discussed.

Guerra, Rosemary↗

Mechanical alloying of a hydrogenation catalyst used for the remediation of contaminated compounds

A hydrogenation catalyst including a base material coated with a catalytic metal is made using mechanical milling techniques. The hydrogenation catalysts are used as an excellent catalyst for the dehalogenation of contaminated compounds and the remediation of other industrial compounds. Preferably, the hydrogenation catalyst is a bimetallic particle including zero-valent metal particles coated with a catalytic material. The mechanical milling technique is simpler and cheaper than previously used methods for producing hydrogenation catalysts.

Quinn, Jacqueline W.↗

Mechanical alloying of a hydrogenation catalyst used for the remediation of contaminated compounds

A hydrogenation catalyst including a base material coated with a catalytic metal is made using mechanical milling techniques. The hydrogenation catalysts are used as an excellent catalyst for the dehalogenation of contaminated compounds and the remediation of other industrial compounds. Preferably, the hydrogenation catalyst is a bimetallic particle including zero-valent metal particles coated with a catalytic material. The mechanical milling technique is simpler and cheaper than previously used methods for producing hydrogenation catalysts.