Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Helium cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Experimental and Numerical Evaluation of the Thermal-Fluid Characteristics of the Helium-Cooled Modular Divertor with Multiple Jets Using a Reversed Heat Flux Approach

A single-finger unit of the Helium-Cooled Modular Divertor with Multiple Jets (HEMJ) with a plasma-facing surface (PFS) area of about 2 cm 2 has been studied in a helium (He) loop at He mass flow rates m˙ H ≤ 8 g/s and nearly prototypical conditions. Based on previous studies of the single finger of the HEMJ, our Georgia Institute of Technology group is planning to experimentally study larger divertors. Given that the HEMJ test section was heated with an induction heater and that it is impractical to scale this up to divertors with larger PFS areas, a reversed heat flux approach is being considered to measure heat transfer coefficients (HTCs). In this approach, the direction of the heat flux is reversed with water cooling and high-temperature He heating of the outer shell attached to the PFS. This work presents an initial experimental and numerical evaluation of this approach for a single HEMJ finger. Experiments with brass and copper-chromium-zirconium outer shells were conducted at dimensionless He mass flow rates or Reynolds numbers Re = 1 × 10 4 to 4.7 × 10 4 , an inlet pressure of 10 MPa, temperatures as great as 673 K, and maximum heat flux of 8.4 MW/m 2 . The experiments verify that the He-side HTCs are independent of the direction of the heat flux. Here, the results agree well with previous Nusselt number correlation and pressure loss coefficients for the HEMJ obtained using the normal heating approach.

42 ENGINEERING↗

A liquid-helium-cooled absolute reference cold load for long-wavelength radiometric calibration

Design, radiometric and thermal performance, and operation of a large diameter (78 cm) liquid-helium-cooled blackbody absolute reference cold load (CL) for the calibration of microwave radiometers is described. CL provides an absolute calibration near the liquid-helium (LHe) boiling point, with total uncertainty in the radiometric temperature of less than 30 mK over the 2.5-23 cm wavelength operating range. CL was used at several wavelengths at the South Pole, Antarctica and the White Mountain Research Center, California. Results show that, for the instruments operated at 20-, 12-, 7.9-, and 4.0 cm wavelength at the South Pole, the total corrections to the LHe boiling-point temperature (about 3.8 K) were 48 +/-23, 18 +/-10, 10 +/-18, and 15 +/-mK.

Bensadoun, Marc↗

Consequence analyses of sabotage-induced radiological releases in high-temperature helium-cooled prismatic microreactors

Here, this study analyzes the radiological dose consequences of sabotage-induced accidents at three high-temperature helium-cooled prismatic microreactors (HTPMs) with thermal power ratings of 1, 10, and 50 MWt. Each HTPM employs uranium oxycarbide tristructural isotropic fuel enriched to 19.75 wt% high-assay low-enriched uranium. Simulations were conducted to estimate reactor core inventory at the point of fuel discharge––when the effective multiplication factor reduced to less than 1––representing peak radionuclide inventory. Postulated sabotage scenarios leading to reactor shutdown were analyzed at two intervals: immediately post-shutdown (0 h) and 3 days after shutdown using the SCALE code for radionuclide inventories and the RASCAL tool for dose consequences. Results show that although HTPMs benefit from inherent safety features and robust fuel design, radiological consequences scale with reactor power because of increased source term inventories. Smaller microreactors exhibited proportionally lower dose consequences. To support the economic and regulatory feasibility of microreactor deployment, this study emphasizes the value of a risk-informed, performance-based approach, as supported by regulations like 10 CFR Parts 100 and 53 in the United States. Microreactor developers should perform site-specific assessments of potential sabotage or low-probability, high-consequence events, especially when considering minimal on-site or full off-site emergency response.

Consequence↗

Efficiency analysis of helium-cooled MAS DNP: case studies of surface-modified nanoparticles and homogeneous small-molecule solutions

Despite the growing number of successful applications of dynamic nuclear polarization (DNP)-enhanced magic-angle spinning (MAS) NMR in structural biology and materials science, the nuclear polarizations achieved by current MAS DNP instrumentation are still considerably lower than the theoretical maximum. Here, the method could be significantly strengthened if experiments were performed at temperatures much lower than those currently widely used (~100 K). Recently, the prospects of helium (He)-cooled MAS DNP have been increased with the instrumental developments in MAS technology that uses cold helium gas for sample cooling. Despite the additional gains in sensitivity that have been observed with He-cooled MAS DNP, the performance of the technique has not been evaluated in the case of surfaces and interfaces that benefit the most from DNP. Herein, we studied the efficiency of DNP at temperatures between ~30 K and ~100 K for organically functionalized silica material and a homogeneous solution of small organic molecules at a magnetic field B 0 = 16.4 T. We recorded the changes in signal enhancement, paramagnet-induced quenching and depolarization effects, DNP build-up rate, and Boltzmann polarization. For these samples, the increases in MAS-induced depolarization and DNP build-up times at around 30 K were not as severe as anticipated. In the case of the surface species, we determined that MAS DNP at 30 K provided ~10 times higher sensitivity than MAS DNP at 90 K, which corresponds to the acceleration of experiments by multiplicative factors of up to 100.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of Gaseous Helium Cooling in a Superconducting Coil Test Rig

An experimental rig was designed and constructed at the NASA Glenn Research Center to measure the alternating current (AC) losses of round, multifilament, superconducting (SC), magnesium diboride (MgB2) wire in the temperature range from 20 to 30 K. The rig resembles a permanent magnet (PM) motor with the stator windings omitted. Experiment packs containing the superconductor samples will be placed in the annular space between the rotor and the stator back iron. The original plan was to measure the AC losses by calorimetry using nonboiling liquid hydrogen as the cooling fluid. The present plan is to use helium gas (GHe) under a few bar pressure instead. This report summarizes the calculations that indicate that reasonable results can be obtained, even though the mass density of the GHe will be only a fraction of that of liquid hydrogen. It is necessary to show that the heat transfer coefficient from SC wire to GHe can be high enough, that the temperature rise of the He between the experiment inlet and outlet can be small enough, and that sufficient He flow can be driven by a commercially available He fan. Both straight wire samples to validate loss models and coils to simulate motor stator coils can be tested in the rig. The lowest superconductor temperature that is feasible to reach in the rig is estimated. The temperature range available for samples will be wider with the gaseous He system than it would have been with liquid hydrogen.

supeconductors↗

Investigation Development Plan for Reflight of the Small Helium-cooled Infrared Telescope Experiment. Volume 1: Investigation and Technical/management

The Infrared Telescope (IRT) is designed to survey extended celestial sources of infrared radiation between 4 and 120 micrometers wavelength. It will provide data regarding Space Shuttle induced environmental contamination and the zodical light. And, it will provide experience in the management of large volumes of superfluid helium in the space environment.

Source record↗

Small helium-cooled infrared telescope experiment for Spacelab-2 (IRT)

The Infrared Telescope (IRT) experiment, flown on Spacelab-2, was used to make infrared measurements between 2 and 120 microns. The objectives were multidisciplinary in nature with astrophysical goals of mapping the diffuse cosmic emission and extended infrared sources and technical goals of measuring the induced Shuttle environment, studying properties of superfluid helium in space, and testing various infrared telescope system designs. Astrophysically, new data were obtained on the structure of the Galaxy at near-infrared wavelengths. A summary of the large scale diffuse near-infrared observations of the Galaxy by the IRT is presented, as well as a summary of the preliminary results obtained from this data on the structure of the galactic disk and bulge. The importance of combining CO and near-infrared maps of similar resolution to determine a 3-D model of galactic extinction is demonstrated. The IRT data are used, in conjunction with a proposed galactic model, to make preliminary measurements of the global scale parameters of the Galaxy. During the mission substantial amounts of data were obtained concerning the induced Shuttle environment. An experiment was also performed to measure spacecraft glow in the IR.

Fazio, Giovanni G.↗

NorthStar Helium Cooling System. Final Report on LANL Contribution

From the beginning of NNSA support to the NorthStar development of a production facility for the medical isotope Molybdenum-99 (Mo99), LANL has been responsible for the design and testing of a target and its cooling. The target is comprised of a stack of Mo100 disks separated by coolant flow gaps between the disks and between the first disk and a housing window, which separates the target and its coolant from the vacuum of the beam line. The target, and therefore its cooling requirements, evolved steadily over the years of system development

07 ISOTOPE AND RADIATION SOURCES↗

Liquid-helium-cooled Michelson interferometer

Interferometer serves as a rocket-flight spectrometer for examination of the far infrared emission spectra of astronomical objects. The double beam interferometer is readily adapted to make spectral scans and for use as a detector of discrete line emissions.

Augason, G. C.↗

Experiment requirements document for reflight of the small helium-cooled infrared telescope experiment

The four astronomical objectives addressed include: the measurement and mapping of extended low surface brightness infrared emission from the galaxy; the measurement of diffuse emission from intergalactic material and/or galaxies and quasi-stellar objects; the measurement of the zodiacal dust emission; and the measurement of a large number of discrete infrared sources.

Source record↗

Sensitive method for characterizing liquid helium cooled preamplifier feedback resistors

It is pointed out that the simple and traditional method of measuring resistance using an electrometer is ineffective since it is limited to a narrow and nonrepresentative range of terminal voltages. The present investigation is concerned with a resistor measurement technique which was developed to select and calibrate the Transimpedance Mode Amplifier (TIA) load resistors on the Infrared Astronomical Satellite (IRAS) for the wide variety of time and voltage varying signals which will be processed during the flight. The developed method has great versatility and power, and makes it possible to measure the varied and complex responses of nonideal feedback resistors to IR photo-detector currents. When employed with a stable input coupling capacitor, and a narrow band RMS voltmeter, the five input waveforms thouroughly test and calibrate all the features of interest in a load resistor and its associated TIA circuitry.

Smeins, L. G.↗