Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Helium cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Preliminary Assessment of Additively Manufactured Cooling Channel Performance for Helium-Cooled Blanket Concepts

Sufficient cooling of the blanket first wall remains a critical challenge for the design and deployment of fusion power plants. Helium has been targeted as a potential blanket coolant due to its inertness and low neutron interactivity, among other advantages. However, the low thermal mass of helium creates a need for heat transfer enhancements in coolant channels to provide adequate cooling to the blanket’s first wall. Toward this end, a series of ribbed flow channels of various rib cross sections and configurations has been produced via additive manufacturing (AM) to study the efficacy of AM for first wall heat transfer enhancement and the optimization of heat transfer geometries. Helium cooling performance is studied in AM test articles at 4 MPa operating pressure, Reynolds numbers up to 197 000, and outer surface heat fluxes up to 42 kW/m 2 in the recently commissioned helium flow loop experiment (HFLE). Preliminary results of this study are presented herein. Heat transfer performance of nominally smooth (i.e., featureless) AM channels is quantified via measured Nusselt numbers and friction factors and compared to off-the-shelf smooth pipe experiments. Results are compared to existing correlations and used to discuss the effects of the AM processes on thermal-hydraulic performance. It is seen that the inherent roughness of the AM channels leads to an increase in both heat transfer coefficient and pressure drop when compared to the conventional pipe. In conclusion, recommendations are made for future studies based on these findings and additional considerations for the deployment of AM blanket cooling components.

36 MATERIALS SCIENCE↗

Liquid helium-cooled MOSFET preamplifier for use with astronomical bolometer

A liquid helium-cooled p-channel enhancement mode MOSFET, the 3N167, is found to have sufficiently low noise for use as a preamplifier with helium-cooled bolometers that are used in infrared astronomy. Its characteristics at 300, 77, and 4.2 K are presented. It is also shown to have useful application with certain photoconductive and photovoltaic infrared detectors.

Goebel, J. H.↗

Helium-Cooled Black Shroud for Subscale Cryogenic Testing

This shroud provides a deep-space simulating environment for testing scaled-down models of passively cooling systems for spaceflight optics and instruments. It is used inside a liquid-nitrogen- cooled vacuum chamber, and it is cooled by liquid helium to 5 K. It has an inside geometry of approximately 1.6 m diameter by 0.45 m tall. The inside surfaces of its top and sidewalls have a thermal absorptivity greater than 0.96. The bottom wall has a large central opening that is easily customized to allow a specific test item to extend through it. This enables testing of scale models of realistic passive cooling configurations that feature a very large temperature drop between the deepspace-facing cooled side and the Sun/Earth-facing warm side. This shroud has an innovative thermal closeout of the bottom wall, so that a test sample can have a hot (room temperature) side outside of the shroud, and a cold side inside the shroud. The combination of this closeout and the very black walls keeps radiated heat from the sample s warm end from entering the shroud, reflecting off the walls and heating the sample s cold end. The shroud includes 12 vertical rectangular sheet-copper side panels that are oriented in a circular pattern. Using tabs bent off from their edges, these side panels are bolted to each other and to a steel support ring on which they rest. The removable shroud top is a large copper sheet that rests on, and is bolted to, the support ring when the shroud is closed. The support ring stands on four fiberglass tube legs, which isolate it thermally from the vacuum chamber bottom. The insides of the cooper top and side panels are completely covered with 25- mm-thick aluminum honeycomb panels. This honeycomb is painted black before it is epoxied to the copper surfaces. A spiral-shaped copper tube, clamped at many different locations to the outside of the top copper plate, serves as part of the liquid helium cooling loop. Another copper tube, plumbed in a series to the top plate s tube, is clamped to the sidewall tabs where they are bolted to the support ring. Flowing liquid helium through these tubes cools the entire shroud to 5 K. The entire shroud is wrapped loosely in a layer of double-aluminized Kapton. The support ring s inner diameter is the largest possible hole through which the test item can extend into the shroud. Twelve custom-sized trapezoidal copper sheets extend inward from the support ring to within a few millimeters of the test item. Attached to the inner edge of each of these sheets is a custom-shaped strip of Kapton, which is aluminum- coated on the warm-facing (outer) side, and has thin Dacron netting attached to its cold-facing side. This Kapton rests against the test item, but the Dacron keeps it from making significant thermal contact. The result is a non-contact, radiatively reflective thermal closeout with essentially no gap through which radiation can pass. In this way, the part of the test item outside the shroud can be heated to relatively high temperatures without any radiative heat leaking to the inside.

Tuttle, James↗

A small helium-cooled infrared telescope for Spacelab 2

A helium cooled telescope of 15 cm aperture is being designed and constructed jointly by the University of Arizona, the Smithsonian Astrophysical Observatory and the Marshall Space Flight Center for high sensitivity infrared astronomical observations from Spacelab 2. A focal plane array of ten detectors provide a total field of view of 3 deg and cover the wavelength regions 4.5-8.5, 6-7, 9-16, 18-30 and 80-120 microns. A highly redundant all sky survey will be conducted by repeated scanning of the sky during many orbits of the spacecraft. High redundancy will allow discrimination among variable and constant celestial sources and several types of variable nearby sources. The principal astronomical result of the survey will be the absolute flux measurement of low surface brightness, large scale celestial infrared emissions but it will also extend existing IR sky surveys by a factor of 10 in point source sensitivity. The experiment will also make significant engineering measurements of contaminants in the Shuttle environment, test the technology of storage and utilization of large quantities of superfluid helium in space and test mechanical designs for future infrared telescopes for the Space Shuttle.

Gautier, T. N., III↗

Experimental evaluation of thermal-fluids performance of Helium-Cooled Flat Plate (HCFP) divertor

Various helium (He)-cooled solid-tungsten (W) divertor concepts have been proposed for long-pulse magnetic fusion energy reactors. Among these concepts, the He-cooled flat plate divertor (HCFP) modules have the largest plasma-facing surface area of ~0.2 m 2 . Simulations have shown that the most recent version of the design can withstand heat fluxes as great as 8 MW/m 2 . Earlier experimental studies of a single shortened HCFP cooling unit with a slot length of 7.6 cm used air at ambient temperature and pressures below 0.6 MPa. Here, we present initial experimental studies of a copper alloy and steel test section modeling a shortened HCFP cooling unit using He at prototypical pressure of 10 MPa, inlet temperatures T i ≤ 200 °C and steady-state incident heat fluxes q" ≤ 1.2 MW/m 2 . Results for Nusselt number Nu as a function of Reynolds number Re were obtained for Re = 1.2×10 4 –3.4×10 4 , and used to develop a Nu(Re) correlation and validate numerical models of the test section using commercial computational fluid dynamics (CFD) software. Simulations with this model are performed to evaluate the effect of the shortened slot. Furthermore, these analyses are used to estimate the thermal-fluids performance of the HCFP under prototypical conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Testing of Helium Cooled Metal Molybdenum Disk Target System

NorthStar Medical Radioisotopes LLC is planning to produce the important medical radioisotope molybdenum-99 (Mo-99) through a photonuclear reaction on molybdenum-100 (Mo-100). In this approach, multiple thin disks of enriched molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, we intend to use as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium atmosphere inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flow from one side, making the window design challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess as high a tensile strength as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and the high thermal stress from beam heating.

42 ENGINEERING↗

Freeze range of a condensing gas propagating in a liquid helium-cooled tube

Understanding air propagation and condensation following a catastrophic vacuum break in particle accelerator beamlines cooled by liquid helium is crucial for maintaining the operational safety of these facilities. Previous experimental investigations on nitrogen gas propagation in both normal liquid helium (He I) and superfluid helium (He II) cooled copper tubes unveiled a nearly exponential deceleration of the gas propagation. A comprehensive theoretical model incorporating gas dynamics, heat transfer, and condensation mechanisms has been developed, which effectively reproduces various key experimental observations. An intriguing phenomenon uncovered in our model simulation is that the gas propagation appears to nearly stop beyond a certain distance from the location where condensation starts. We refer to this distance as the freeze range. In this paper, we present our systematic study of the freeze range at various inlet mass fluxes and tube diameters. We show that the results can be well described by a simple correlation. The underlying physical mechanism that supports this useful correlation is explained. Knowing the freeze range may allow accelerator engineers to develop protocols for controlling frost-layer contamination in the beamline tubes, which is of great practical importance.

43 PARTICLE ACCELERATORS↗

A liquid helium cooled Fabry-Perot infrared spectrometer

A liquid-helium-cooled Fabry-Perot infrared spectrometer offering excellent performance in the middle infrared range has been constructed and tested. The spectrometer is based on newly developed superconducting actuators which control the alignment and tuning at 4.2 K with virtually no power dissipation within the instrument. Depending on the availability of high-quality etalons, this type of spectrometer should be useful in a wide range of infrared astronomical spectroscopy applications.

Nishimura, T.↗

Testing of Helium-Cooled Metal Molybdenum Disk Target

NorthStar Medical Radioisotopes LLC is planning to produce an important medical radioisotope, molybdenum-99 (Mo-99), through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, it is desired to use as much beam power as possible to achieve maximum production yield and minimize target mass. This objective leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the main challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium inside the target from the vacuum in the beamline, so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flowing on one side, making the window cooling even more challenging. High heat deposition in the target disks also imposes a strict requirement on performance of the helium cooling system and thickness of the target disks. The target disks are produced from metal powder via a press-and-sinter process. The resulting disks do not possess tensile strength as high as solid molybdenum and might not survive the vibration from the high-velocity helium coolant and high thermal stress from beam heating. An Argonne team of scientists performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF) [3-7]. This report describes two series of tests for scale down production target designs that utilize full-scale 29 millimeters diameter, 0.75 mm thick press-and-sintered disks. We performed two thermal tests with different beam parameters and configurations of the disk laminations. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.

36 MATERIALS SCIENCE↗

Advances in understanding vacuum break dynamics in liquid helium-cooled tubes for accelerator beamline applications

Understanding air propagation and condensation following a catastrophic vacuum break in particle accelerator beamlines cooled by liquid helium is essential for ensuring operational safety. This review summarizes experimental and theoretical work conducted in our cryogenics lab to address this issue. Systematic measurements were performed to study nitrogen gas propagation in uniform copper tubes cooled by both normal liquid helium (He I) and superfluid helium (He II). These experiments revealed a nearly exponential deceleration of the gas front, with stronger deceleration observed in He II-cooled tubes. To interpret these results, a one-dimensional (1D) theoretical model was developed, incorporating gas dynamics, heat transfer, and condensation mechanisms. The model successfully reproduced key experimental observations in the uniform tube system. However, recent experiments involving a bulky copper cavity designed to mimic the geometry of a superconducting radiofrequency (SRF) cavity revealed strong anisotropic flow patterns of nitrogen gas within the cavity, highlighting limitations in extrapolating results from simplified tube geometries to real accelerator beamlines. To address these complexities, we outline plans for systematic studies using tubes with multiple bulky cavities and the development of a two-dimensional (2D) model to simulate gas dynamics in these more intricate configurations. As a result, these efforts aim to provide a comprehensive understanding of vacuum breaks in particle accelerators and improve predictive capabilities for their operational safety.

Beamline tube↗

Far-Infrared Photometry with an 0.4-Meter Liquid Helium Cooled Balloon-Borne Telescope

A 0.4-meter aperture, liquid helium cooled multichannel far-infrared balloon-borne telescope was constructed to survey the galactic plane. Nine new sources, above a 3-sigma confidence level of 1300 Jy, were identified. Although two-thirds of the scanned area was more than 10 degrees from the galactic plane, no sources were detected in that region; all nine fell within 10 degrees and eight of those within 4 degrees of the galactic equator. Correlations with visible, compact H lines associated with radio continuum and with sources displaying spectra steeply rising between 11 and 20 microns were noted, while stellar objects were not detected.

Jacobson, M. R.↗

A liquid-helium-cooled grating spectrometer for far infrared astronomical observations

A liquid-helium-cooled grating spectrometer has been developed for low-resolution far-infrared spectrometric measurements of astronomical sources conducted by the 30-cm NASA Lear Jet telescope. Simple MOSFET coupled transimpedance preamplifiers were adopted for the spectrometer design. The infrared spectrometer has resolving powers from 10 to 150 over the wavelength range from 45 to 115 microns.

Houck, J. R.↗

A turnkey gaseous helium-cooled superconducting CORC ® dc power cable with integrated current leads

Abstract High-temperature superconducting (HTS) direct current (dc) power cable systems, capable of delivering power exceeding 10 MW while being cooled with cryogenic helium gas, have been developed for applications on naval electric ships, electric aircraft and in data centers. Current injection from room temperature into the superconducting power cable causes by far the greatest heat load to the cryogenic system. Efficient current leads with integrated helium gas heat exchangers were developed to inject a current exceeding 1 kA from room temperature into a superconducting Conductor on Round Core (CORC ® ) power cable, without the need for liquid nitrogen pre-cooling. A 2 m long single-pole CORC ® power cable system that included current leads was cooled using a Stirling cryocooler with a closed-loop helium gas circulation system. The turnkey power cable system allowed cool down from room temperature to its operating temperature of 60 K–70 K within 5 h, after which continuous operation at 1.2 kA was demonstrated. The successful development and demonstration of a CORC ® power cable with current leads containing integrated helium gas heat exchangers enables widespread implementation of HTS MW-class, high current density superconducting dc power cables in many applications with constrained space that require a power dense solution.

Physics↗

Estimation of the Thermal-Fluids and Thermal-Structural Performance of Helium-Cooled Modular Finger-Type Divertors

Over the past decade, our group has investigated the thermal-fluid performance of the helium-cooled modular divertor with multiple jets (HEMJ) and a simplified “flat” design of the HEMJ for long-pulse magnetic fusion energy (MFE) reactors. Experimental studies were performed in a helium (He) loop at the prototypical pressure of 10 MPa, nearly prototypical He temperatures and incident heat fluxes using test sections made from stainless steel and tungsten alloys. Correlations for average Nusselt numbers and pressure loss coefficients were developed from the data and are used to validate computational fluid dynamics (CFD) models. Here, this work presents updated thermal-fluids performance curves based on these correlations that estimate the maximum heat flux that can be accommodated by the plasma-facing surface and coolant pumping power requirements at prototypical operating conditions. Thermal-structural performance curves developed from ITER structural design criteria are introduced, which include protection against ductile and non-ductile failure, ratcheting fatigue, and creep fatigue. The performance design curves for these finger-type divertors demonstrate that the “flat” design, with a significantly less complicated geometry than the HEMJ, has thermal-fluid and thermal-structural performance comparable to the original HEMJ concept, and may be superior in terms of non-ductile failure criteria.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heat and mass transfer during a sudden loss of vacuum in a liquid helium cooled tube - Part III: Heat deposition in He II

A sudden loss of vacuum can be catastrophic for superconducting particle accelerators. In such an event, air leaks into the liquid-helium-cooled accelerator beamline tube and condenses on its inner surface, causing rapid boiling of the helium and dangerous pressure build-up. Understanding the coupled heat and mass transfer processes is important for the design of the beamline cryogenic system. Our past experimental study on nitrogen gas propagating in a copper tube cooled by normal liquid helium (He I) has revealed a nearly exponential slowing down of the gas front. A theoretical model that accounts for the interplay of the gas dynamics and the condensation was developed, which successfully reproduced various key observations. However, since many accelerator beamlines are actually cooled by superfluid helium (He II) in which the heat transfer is via a non-classical thermal counterflow mode, we need to extend our work to the He II cooled tube. This paper reports our systematic measurements using He II and the numerical simulations based on a modified model that accounts for the He II heat-transfer characteristics. By tuning the He II peak heat-flux parameter in our model, we have reproduced the observed gas dynamics in all experimental runs. The fine-tuned model is then utilized to reliably evaluate the heat deposition in He II. Finallly, this work not only advances our understanding of condensing gas dynamics but also has practical implications to the design codes for beamline safety.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗