Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Headspace Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

A Study of the Curation Protocol by Sample Analysis Working Team (SAWT) in Martian Moons eXploration (MMX) Project

Japan Aerospace Exploration Agency (JAXA) will launch a spacecraft in 2024 for a sample return mission from Phobos (Martian Moons eXploration: MMX). The major scientific goals of MMX are to constrain (1) the origin of Phobos and Deimos and (2) the evolution of the Mars-moon system [1]. The touchdown operations are planned to be performed twice at different landing sites on the Phobos surface to collect > 10 g of the surface materials [2]. After the return to the Earth, the Phobos samples will be collected from the individual sample canisters and introduced to the clean chamber installed at ISAS (Institute of Space and Astronautical Science). The Sample Analysis Working Team (SAWT) of MMX designed the procedure of Phobos sample analysis mainly conducted by the initial analysis teams [3]. For the next step, the SAWT will define the procedure of the curation process (mostly non-destructive analysis) of the Phobos samples, which will be presented here. The protocols of the Phobos sample curation is illustrated in figure 1. First, the headspace gas from the sample container will be collected during the Quick Analysis phase. The Quick Analysis will be operated by the sampler and curation teams in ISAS/JAXA. The terrestrial leak and contamination from the sampling systems will be tested using a quadrupole mass spectrometer equipped with a gas sampling system. Second, the bulk Phobos sample will be observed in the clean chamber under purified-N2 gas with an ambient condition (Pre-basic Characterization). This phase will be operated by the curation team in ISAS/JAXA and the instrument team of the MMX mission. The consistency between the data from the instruments in the clean chamber and the spacecraft will then be evaluated. Subsequently, the curation will distribute the small amount of Phobos samples to the Initial analysis team of MMX to conduct the "Preliminary Examination". The objectives of the preliminary examination are to provide (1) feedback on the subsequent sample allocation process, (2) preliminary scientific results that will address parts of MMX mission goals, and (3) evaluation of the sampling system and terrestrial alteration on Phobos samples. Because multiple models are proposed for the origin of Phobos [1] (e.g., giant impact, the capture of asteroids), the chemical and mineralogical characteristics of Phobos must be assessed before the allocation of the samples to the individual initial analysis teams. Simultaneously, the curation team in JAXA will observe the individual grains and aliquots of the samples in the clean chamber (Basic Characterization).

R Fukai↗

Chemical Profiling of Volatile Organic Compounds in the Headspace of Algal Cultures as Early Biomarkers of Algal Pond Crashes

Algae ponds used in industrial biomass production are susceptible to pathogen or grazer infestation, resulting in pond crashes with high economic costs. Current methods to monitor and mitigate unhealthy ponds are hindered by a lack of early indicators that precede culture crash. We used solid-phase microextraction (SPME) coupled with gas chromatography-mass spectrometry (GC-MS) to identify volatiles emitted from healthy and rotifer infested cultures of Microchloropsis salina. After 48 hours of algal growth, marine rotifers, Brachionus plicatilis, were added to the algae cultures and volatile organic compounds (VOC) were sampled from the headspace using SPME fibers. A GC-MS approach was used in an untargeted analysis of VOCs, followed by preliminary identification. The addition of B. plicatilis to healthy cultures of M. salina resulted in decreased algal cell numbers, relative to uninfected controls, and generated trans-β-ionone and β-cyclocitral, which were attributed to carotenoid degradation. The abundances of the carotenoid-derived VOCs increased with rotifer consumption of algae. Our results indicate that specific VOCs released by infected algae cultures may be early indicators for impending pond crashes, providing a useful tool to monitor algal biomass production and pond crash prevention.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers'’ for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field's Metal eutectic alloy with a melting point of 62°C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions. It is recommended that glass vessels of various volumes ranging from 125 mL to 1 gallon with modified tops containing the specified Field's Metal eutectic alloy which are appropriately designed to avoid flashing spray material releases be added to the DSA container list. These vessels will be utilized in the Shielded Cells for the storage of radioactive liquid samples of sludge slurries. Use of these vessels will also be advantageous for other liquid samples containing accountable amounts of nuclear material throughout other SRNL laboratories. Similarly constructed paraffin vessel lids could also potentially be added to the approved list, though additional testing would be required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers” for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field’s Metal eutectic alloy with a melting point of 62 °C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential for Evaporation and In Situ Reaction of Organic Compounds in Hanford Supplemental LAW

The presence of regulated organic species in Hanford nuclear tank waste is assessed in this report, along with fate of the organics and possible evaporative treatment. A narrowed list of regulated organic species of concern is developed based upon published analyses, chemical properties like aqueous solubility, and chemical reactivity under alkaline conditions. Published analyses include tank headspace and liquid samples, review of chemical reagents formerly used at Hanford, and the Tank Waste Information Network System (TWINS). This work supports possible stabilization of Hanford Supplemental Low Activity Waste (SLAW) by grouting.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Potential for Evaporation and In Situ Reaction of Organic Compounds in Hanford Supplemental LAW

The presence of regulated organic species in Hanford nuclear tank waste is assessed in this report, along with fate of the organics and possible evaporative treatment. A narrowed list of regulated organic species of concern is developed based upon published analyses, chemical properties like aqueous solubility, and chemical reactivity under alkaline conditions. Published analyses include tank headspace and liquid samples, review of chemical reagents formerly used at Hanford, and the Tank Waste Information Network System (TWINS). This work supports possible stabilization of Hanford Supplemental Low Activity Waste (SLAW) by grouting.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Management of the Three Mile Island, Unit 2, Accident Corium and Severely Damaged Fuel Debris

The Three Mile Island, Unit Two (TMI-2) pressurized water reactor core melted down in 1979 due to an untimely combination of maintenance problems that led to a loss of feedwater, followed by a series of operational misunderstandings and errors. The melted core recovery process required development of a wide array of tools. After approximately three years of water management and other cleanup actions, the first views of the core revealed a much higher degree of damage than previously expected. Approximately 62 metric tons of the core had melted, leaving only 42 of the 177 fuel assemblies standing with a majority of rods intact. The core to be recovered was composed of loose debris and a solidified mass of formerly molten fuel. Robotic tools that had been designed for the task were of limited effectiveness due to the range of material types and phases. Over a period of several years, the central melt was broken up, primarily by use of a core-boring drill originally designed to acquire samples through the depth of the debris field. The broken pieces were loaded into specially designed debris canisters by use of long-handled pick-and-place tools and suctioned into baffled knockout canisters using an airlift vacuum system. A remotely operable underwater plasma arc torch was developed for removal of the lower core support structure to be able to retrieve the fuel pieces and secondary melt that had accumulated on the bottom reactor vessel head. Canister design played a central role in defining the initial retrieval process and later affected transportation, interim wet and its current interim dry storage. Due to concerns about the potential for radiolysis of residual water in the debris and other canister material, the canisters were fitted with hydrogen recombiner catalyst units to prevent a buildup of flammable gas and potential pressurization. To confirm the effectiveness of the recombiners during shipping, eight dewatered canisters were kept sealed for up to 205 days with periodic sampling of the headspace gas. The highest hydrogen value (9 vol%) was observed in a canister held for 147 days while the longest stored canister resulted in a 5% hydrogen concentration. The oxygen concentration never exceeded 0.5 %, and the primary backfill was >80% argon, meaning there was no flammability risk. Radiolytic hydrogen was also observed in wet pool storage, where the vented canisters discharged a portion of the water backfill as a result of gas production. The 344 canisters (268 fuel debris, 62 filter, and 12 knockout type) were dewatered, loaded in groups of seven into a double barrier shipping cask, and transported to the U.S. Department of Energy site in Idaho for 10 years of pool storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Differential Organic Carbon Mineralization Responses to Soil Moisture in Three Different Soil Orders Under Mixed Forested System: Supporting Data

This data contains data from 90-day long incubation study which aimed to look at the soil moisture-texture relationship on soil organic carbon (SOC) cycling. Soils were collected from three distinct soil textures from mixed forests in 2017: sandy (Georgia, 2017-05-01), loamy (Missouri, 2017-06-14) and clayey (Texas, December 2017) were incubated at different soil moisture levels (air-dried, 25% water holding capacity (WHC), 50% WHC, 100% WHC and 175% WHC) at room temperature for a period of 90 days. Files contain microbial respiration, active and slow SOC pools, and their respective mineralization rates, extractable organic carbon (C), and C-acquiring extracellular enzymes. Findings from these data were used in Singh et al. (2021). This study aimed to examine the interactive effect of soil moisture and texture on SOC mineralization. Soil samples of three distinct textures (sandy, loamy, and clayey) were collected from mixed forests of Georgia, Missouri, and Texas, respectively. Soil cores of 5 cm diameter were collected from numerous random locations at each site from 0-15 cm depth after scraping the litter layer and mixed thoroughly to obtain a composite sample per site. Three additional soil cores were collected to determine the WHC using pressure plate extractors. Soil samples were composited, and triplicate soil samples were incubated in mason jars for a period of 90 days at room temperature under different moisture regimes: air dried, 25% WHC, 50% WHC, at WHC and 100% saturation. Soil respiration was measured weekly, and destructive sampling was conducted at 1, 15, 60, and 90 days to determine extractable organic C, C acquiring enzyme activity, and active and slow SOC pools with their respective mineralization rates. The C acquiring enzyme activity was the total activity of α-glucosidase, β-glucosidase, cellobiohydrolase, and β-xylosidase enzymes. Gas samples for microbial respiration measurements were collected from headspace of incubation jars through the sampling ports on the lids and then analyzed using a Shimadzu Gas Chromatograph (GC-2014). Prior to sampling, the vials were evacuated. Blank correction was also done by collecting gas samples from empty incubation jars. Double pool exponential decay model was used in SigmaPlot to determine the active and slow SOC pools and their mineralization rates (Farrar et al., 2012; Jagadamma et al., 2014). The C-acquiring extracellular enzymes were measured using the microplate method by German et al., (2011). Microbial community structure was determined using the phospholipid fatty acid (PLFA) and neutral lipid fatty acid (NLFA) analyses (Buyer and Sasser, 2012). This dataset has seven data files provided in comma-separate (*.csv) format. Additional metadata are provided: seven data dictionaries and a file-level metadata file in comma separate (*.csv) format and a user guide in PDF (*.pdf) format.

Carbon acquiring enzyme activity↗

MSR Science Planning Group 2 (MSPG2): Science & Curation Considerations for Time Sensitive Measurements That Should be Performed in Containment

The Perseverance rover is currently collecting samples on the martian surface for potential return to Earth and planning is underway to develop facilities to study these samples. Perseverance will collect up to 38 samples that will be sealed in TiN tubes. As long as the tubes remain sealed the samples will be metastable. However, as soon as a tube is opened, or headspace gas is extracted these samples will begin to re-equilibrate with their new surroundings. The MSPG2 time-sensitive science sub-group attempted to quantify the rates at which alteration is likely to occur assuming the samples are opened and stored in a nitrogen atmosphere at room temperature. The group also recommended ~20 instruments for inclusion in a sample receiving facility to allow the time sensitive properties of these samples to be measured before they are irreversibly altered.

Aaron B Regberg↗

Ambient vapor sampling and selective cluster formation for the trace detection of tributyl phosphate via atmospheric flow tube mass spectrometry

In addition to serving as an f-element ligand and rare-earth method complexing agent, tributyl phosphate (TBP) is a compound containing core functional groups that mimic those routinely found in degradation products from industrial processes. Because detection of trace quantities of TBP can provide insight into the routes of contamination and degradation in the environment, there is a need to develop methods capable of detecting trace quantities of TBP. Vapor detection at atmospheric pressure is one approach that is both sensitive and rapid. We present here the use of atmospheric flow tube mass spectrometry (AFT-MS) for the ambient vapor sampling of TBP from headspace of ppb-level solutions in methanol. Gas phase clustering reactions were to enhance detection levels via the addition of small quantities of the dopants diethylamine (DEA), triethylamine (TEA), and pinacolyl methylphosphonate (PMP) in the vapor stream. Detection of the TBP vapor emanating from these solutions demonstrated a linear range for the protonated TBP species of 1-1000 ppb from solution. The clusters of TBP with DEA, TEA, and PMP each yielded linear ranges of 1-250 ppb for TBP in solution. Despite smaller linear ranges, the addition of these dopant species added a layer of analytical selectivity and reduced variability in signals from quality control samples. These data were obtained using an AFT source coupled to a linear ion trap mass spectrometer, which demonstrates the applicability of trapping systems to the AFT ionization technique while monitoring positive ions.

Ambient vapor sampling, Dielectric barrier dischar↗

Initial Testing of an In Situ Load Retention Aging Vessel

A thermal aging vessel instrumented with load cells was fabricated. The primary function of the vessel is to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary function is to enable gas sampling of the vessel headspace during thermal aging. Heating of the vessel is achieved using a custom heater jacket. To improve upon our conventional aging study methods which require periodic interruption of aging to perform load testing in an Instron machine at room temperature, this technology aims to automate/facilitate data acquisition/analysis, improve data quality, and enable uninterrupted compression of the polymer which represents the service condition. As an example case to assess functionality of the in situ vessel, the load retention of a siloxane elastomer material additively manufactured by direct-ink-writing (DIW) was measured at three different isothermal aging temperatures for ~1 month. Initial compression of the coupons while near the aging temperature was achieved by temporarily opening the heated vessel to access the interior chamber and manually tightening four nuts to drive the heated compression plate down onto the heated coupons. Initial testing demonstrated achievement of the primary load retention monitoring function. Unfortunately, the vessel leaked which prevented gas sampling; an active purge was used to maintain a nitrogen atmosphere. Welded or otherwise sealed joints, which could be implemented in a future design, would likely eliminate leak paths. To apply time-temperature superposition (TTS), a technique used to provide long-term prediction of the load retention from short-term isothermal data, the load retention needed to be calculated relative to the load at an estimated “equilibrium” time, after most of the transient viscoelastic physical relaxation occurred. The peak load immediately after compression could not be used as the load retention basis for two reasons: (1) age-related changes must be isolated from non-age-related physical relaxation before applying TTS and (2) the manual mechanism used to compress the specimens at the aging temperature was neither smooth nor repeatable which affected the peak load value. To better understand the effect of the mode of initial compression on the measured load, and possibly better estimate “equilibrium” physical relaxation times, systematic stress relaxation experiments were performed using an Instron machine with a thermal chamber. At a given temperature, the DIW polymer was compressed to a fixed strain in either a stepped or continuous manner at two different rates, then held at that strain for 24 hrs. The results indicated that, at a given temperature, the different stress relaxation curves appeared to converge to the same curve at some “equilibrium” time when the non-age-related physical relaxation was mostly complete. Though this observation suggests that the discontinuous manual compression employed by the vessel is feasible, a compression mechanism that is rapid, smooth, and repeatable would enhance its use.

36 MATERIALS SCIENCE↗

Progress Update on the In Situ Load Retention Aging Vessel

To improve upon our conventional thermally accelerated aging study methods which require periodic interruption of aging to perform load testing in an Instron machine, a new aging system is being developed to: (1) automate/facilitate data acquisition/analysis, (2) improve data quality, and (3) enable uninterrupted aging conditions (compression, temperature, atmosphere) which represents the service condition. In FY24, a thermal aging vessel instrumented with load cells was fabricated and tested. That unit demonstrated the primary function of the vessel: to continuously monitor the in situ load retention of up to three compressed polymer coupons undergoing thermally accelerated aging under nitrogen. A secondary objective, not realized in the unit due to inadequate sealing, was to enable a single initial nitrogen backfill (as opposed to a continuous purge) and gas sampling of the vessel headspace during thermal aging. Heating of the vessel was achieved using a custom heater jacket.

36 MATERIALS SCIENCE↗

Methods of detecting predators in algal cultures

The present disclosure features methods of detecting crop damage in an algal culture. Such methods include detecting one or more carotenoids as a volatile organic compound in a sample obtained from a headspace of the algal culture.

Fisher, Carolyn Laura↗

Gold Nanoparticles (AuNPs) as Reactive Matrix for Detection of Trace Levels of HCN in Air by Laser Desorption/Ionization Mass Spectrometry (LDI-MS)

Under direct laser desorption/ionization mass spectrometric conditions, the irradiation of target spots made of gold nanoparticle residues generates a series of peaks at m/z 197, 394, 591… representing Au{sub n}{sup −} ions (n = 1–3). In contrast, spectra recorded from gold nanoparticles directly mixed with an alkali cyanide exhibited an additional peak at m/z 249, indicating an abundant generation of gaseous [Au(CN){sub 2}]{sup −} ions upon irradiation. The relative intensity of the m/z 249 peak surged when the amount of cyanide in the mixture was increased. Most remarkably, a peak at m/z 249 was observed even from neat AuNPs upon irradiation, if a nearby spot, which was not irradiated, happened to bear a cyanide sample. We postulated that traces of HCN emanating from the headspace of aqueous cyanide solution during the sample-plate preparation is sufficient to convert gold to AuCN, which is subsequently detected as [Au(CN){sub 2}]{sup −}. Further experiments demonstrated that the relative intensity of the m/z 249 peak diminishes exponentially as the AuNP spot becomes more distant from the putative HCN source. Eventually, the method was developed as an efficient procedure to detect HCN or alkali cyanides. Using KCN, the detection limits were determined to be below 10 pg of CN{sup −} per spot. The method also demonstrated that, upon crushing, the seeds or roots of certain fruits and vegetables such as apple, peach, radish, and cassava, but not carrot, release HCN in amounts detectable by this method. .

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Six-Membered Concerted Mechanism for CO 2 Capture by Amines Studied under Charged Microdroplet Reaction Conditions

Carbon dioxide (CO 2 ) capture and storage represents an important technological challenge. A mechanistic understanding of interactions involved in the capture process is necessary not only for technological development but also for efficient conversion of captured CO 2 into value-added materials. Herein, we present a novel contained secondary electrospray ionization platform for studying the interactions of gaseous amines and CO 2 gas under microdroplet reaction conditions, which enables mass spectrometry (MS) characterization of CO 2 capture products and intermediates in real time. We detected [2 M + CO 2 + H] + species, which corresponds to a six-membered intermediate. DFT calculations confirmed the high stability of the protonated six-membered ring intermediate. This finding provides a plausible concerted mechanism in the microdroplet environment that excludes the involvement of thermodynamically disfavored ionic species. The carbamic acid counterpart of the final product/salt was readily characterized by tandem MS. The carbamic acid/amine salt was also isolated and characterized by Fourier transform infrared spectroscopy. By virtue of the fact that headspace vapors of amines are sampled, we were able to establish a high-throughput platform that enabled the CO 2 capture capacity of five different amines to be studied in under 2 min. The same device also enabled the absolute quantification of capture capacity.

Amines↗

Advanced Curation: Solving Current and Future Sample Return Problems

Advanced Curation is a wide-ranging and comprehensive research and development effort at NASA Johnson Space Center that identifies and remediates sample related issues. For current collections, Advanced Curation investigates new cleaning, verification, and analytical techniques to assess their suitability for improving curation processes. Specific needs are also assessed for future sample return missions. For each need, a written plan is drawn up to achieve the requirement. The plan draws while upon current Curation practices, input from Curators, the analytical expertise of the Astromaterials Research and Exploration Science (ARES) team, and suitable standards maintained by ISO, IEST, NIST and other institutions. Additionally, new technologies are adopted on the bases of need and availability. Implementation plans are tested using customized trial programs with statistically robust courses of measurement, and are iterated if necessary until an implementable protocol is established. Upcoming and potential NASA missions such as OSIRIS-REx, the Asteroid Retrieval Mission (ARM), sample return missions in the New Frontiers program, and Mars sample return (MSR) all feature new difficulties and specialized sample handling requirements. The Mars 2020 mission in particular poses a suite of challenges since the mission will cache martian samples for possible return to Earth. In anticipation of future MSR, the following problems are among those under investigation: What is the most efficient means to achieve the less than 1.0 ng/sq cm total organic carbon (TOC) cleanliness required for all sample handling hardware? How do we maintain and verify cleanliness at this level? The Mars 2020 Organic Contamination Panel (OCP) predicts that organic carbon, if present, will be present at the "one to tens" of ppb level in martian near-surface samples. The same samples will likely contain wt% perchlorate salts, or approximately 1,000,000x as much perchlorate oxidizer as organic carbon. The chemical kinetics of this reaction are poorly understood at present under the conditions of cached or curated martian samples. Among other parameters, what is the maximum temperature allowed during storage in order to preserve native martian organic compounds for analysis? What is the best means to collect headspace gases from cached martian (and other) samples? This gas will contain not only martian atmosphere but also off-gassed volatiles from the cached solids.

Fries, M.↗

Partitioning of Radionuclides in Various Streams of the Mo-99 Purification Process

The Universal Neutron Irradiator (UNI) was designed to irradiate a small volume of uranium solution and to achieve high fission power without creating a large radionuclide (RN) inventory. The UNI system is equipped with a fully enclosed off-gas system with online hydrogen gas monitoring to prevent the production of an explosive atmosphere, as well as storage cylinders for capturing fission gases. It also includes a catalytic recombiner in the target capsule (to immediately recombine radiolytic hydrogen and oxygen gas in the system) and access ports for sampling the target solution and capsule headspace. In UNI Phase I experiments, 50 mL of uranyl sulfate solution was irradiated at 0.3–0.5 W/mL fission power using a tantalum target assembly to produce photoneutrons via irradiation with an electron beam. The purposes of the Phase I experiments were to test the efficacy of adding 200 ppm Fe 2+ to the target solution to prevent uranyl peroxide precipitation under representative irradiation conditions, and to monitor iodine speciation in the irradiated uranyl sulfate solution. The focus of the UNI Phase II experiments was to use an irradiated uranyl sulfate solution containing a mixture of fission products and monitor their distribution in various streams during the primary recovery column (titania-based column) that separates Mo-99 from uranium. Irradiations were designed to create sufficient activity for tracking their distribution in various processing streams using a combination of gamma counting and inductively coupled plasma mass spectrometry (ICP-MS) analyses. Obtained data will be used to better understand the composition of waste streams, accumulation of RN on the titania column, and identify what RNs accumulate in the uranyl sulfate solution. Furthermore, this knowledge will allow us to determine waste classifications for various streams produced during the Mo-99 purification process and develop an appropriate waste clean-up strategy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗