Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Headspace Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

BY-110 Headspace Sampling Comparison Test: Volume 1

The Hanford Tank Operations Contractor, Washington River Protection Solutions, conducted comparison tests of two Hanford Waste tank vapor sampling systems to determine the relative differences in quantifying Chemicals of Potential Concern (COPC) while sampling the same waste tank. The systems are the traditional in situ, inline headspace sampling (HS) method and the recently developed slipstream sampling unit for testing respirator chemical cartridges known as the cartridge test (CT) rig. The comparison test was performed to determine if results obtained using the CT rig are similar to results obtained using the traditional HS method. Using the CT rig would provide efficiencies in headspace vapors sampling such as applying ALARA principles, minimizing worker entries to the tank farms, and eliminating the physical strain of manually lowering the headspace sampling bundles into the waste tanks. Six sampling events were conducted during January and February 2018 to collect headspace vapor samples from Hanford tank BY-110 with the two systems. Pacific Northwest National Laboratory was tasked with conducting an analysis of the analytical results to assess the comparability of the sampling methods and make recommendations on future testing or deployment of the CT method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

BY-110 Headspace Sampling Comparison Test: Volume 2: Raw Data

The Hanford Tank Operations Contractor, Washington River Protection Solutions, conducted comparison tests of two Hanford Waste tank vapor sampling systems to determine the relative differences in quantifying Chemicals of Potential Concern (COPC) while sampling the same waste tank. The systems are the traditional in situ, inline headspace sampling (HS) method and the recently developed slipstream sampling unit for testing respirator chemical cartridges known as the cartridge test (CT) rig. The comparison test was performed to determine if results obtained using the CT rig are similar to results obtained using the traditional HS method. Using the CT rig would provide efficiencies in headspace vapors sampling such as applying ALARA principles, minimizing worker entries to the tank farms, and eliminating the physical strain of manually lowering the headspace sampling bundles into the waste tanks. Six sampling events were conducted during January and February 2018 to collect headspace vapor samples from Hanford tank BY-110 with the two systems. Pacific Northwest National Laboratory was tasked with conducting an analysis of the analytical results to assess the comparability of the sampling methods and make recommendations on future testing or deployment of the CT method.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A device for volatile organic compound (VOC) analysis from skin using heated dynamic headspace sampling

Abstract Human skin is an important source of volatile organic compounds (VOCs) offering noninvasive methods to gain clinical metabolite information. This work was focused on the development of a skin sampling device based on a dynamic headspace sampling method with the addition of temperature to increase VOC metabolite recovery. The device preconcentrates skin VOC emissions onto a sorbent substrate, which can either be preserved for offline analysis or attached to a real time sensor downstream. In this work, skin VOC samples were analyzed offline using thermal desorption-gas chromatography-mass spectrometry. A list of 10 common skin VOCs was pre-selected to optimize parameters of sampling time, sampling temperature, and sorbent selection. Overall, this study highlights an effective skin VOC sampling technology with a heating dimension (40 °C, rather than 30 °C or no heating) with a sampling time of 15 min (rather than 5 or 30 mins) and onto Tenax TA sorbent (rather than PDMS), which collectively increases the recovery of compounds with lower vapor pressure and decreases the observed variability in skin VOC measurements. Finally, a list of 79 skin VOC compounds were detected and identified within a cohort of 20 young, healthy volunteers.

Biochemistry & Molecular Biology↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗

The Effect of Temperature on the Preservation of Volatile-Rich Lunar Samples

Introduction. The Moon’s south pole is a high-priority target for human exploration and scientific study. This interest is, in part, due to the presence of Permanently Shadowed Regions (PSRs), which could contain high concentrations of unique volatiles at cryogenic temperatures [1]. Returned samples from PSRs may include a unique combination of rocks, regolith, and volatile species, providing unprecedented insights into the history of the Solar System and the potential for resource utilization on the Moon. However, because PSR samples are cryogenic up-on collection, lunar polar sample return will eventually require cold stowage for the journey from the Moon to Earth. Without cold stowage, PSR sample return will likely result in phase changes and chemical reactions within the volatile component of the sample, which would negatively impact the resulting scientific studies of those samples. This abstract summarizes the initial results from an ongoing characterization of analog PSR samples at a range of temperatures, with the goal of defining the temperatures needed for a flight cold stowage freezer. Background. Based on remote sensing observations of the Moon [2], south polar PSRs range in temperature from ~120K for small and/or shallow PSRs to ~20K at the most extreme locations in large, deep PSRs. A range of volatiles have been hypothesized to exist at the surface or subsurface of the lunar poles [3-5 and others]. This hypothesis was verified when the LCROSS mission impacted the <50-K PSR in the crater Cabeus, detecting a range of volatiles from water to low condensation temperature species such as H2S and methane [6]. Species such as H2S and ammonia (also detected by LCROSS) are also highly reactive, and increase the likelihood of chemical reactions at elevated (non-cryogenic) temperatures. At the Johnson Space Center’s Planetary Exploration and Astromaterials Research Laboratory (JSC-PEARL), we have developed a volatile-bearing lunar simulant that incorporates several of the species detected by LCROSS [Table 1] mixed cryogenically with the USGS Lunar Highlands Type (LHT) regolith simulant. The new volatile-regolith simulant will be used to assess the degree of sample alteration at room temperature, -20°C, -80°C, and -196°C (liquid nitro-gen), over a two-week period. Room temperature samples represent those likely to be returned during initial missions without cold stowage, -20°C provides an analog to Apollo cold curated samples, -80°C is the temperature of multiple flight payload freezers (e.g., MELFI), and -196°C is analogous to lunar PSRs. Two weeks is an approximation of the time between sample collection and Earth return for initial Artemis missions. Over this period of time, sample head-space gases will be analyzed using a Universal Gas Analyzer (UGA, a type of mass spectrometer) coupled with a Baratron pressure sensor. After testing, the regolith component of the simulant will be purged of volatiles and preserved for future electron beam and/or FTIR analysis. Experimental Procedure. Volatile-regolith simulants will be produced as an initial homogenous batch; this batch will then be distributed into aliquots (gas chromatography/GC vials or cryo vials), ensuring that each sample has the same starting composition and conditions [Fig. 1]. In addition to the “full” simulant shown in Table 1, less complex simulant compositions will be used as baseline and control samples [Table 2]. Aliquots will be produced in triplicate for each simulant composition, storage temperature, and date of sampling. Headspace gases in all Day 0 samples will be analyzed by the UGA immediately. Cold storage samples for future analytical days will be placed in freezers appropriate to their target temperatures (-20°C, -80°C, -196°C). For ambient-temperature samples, regolith and regolith-water samples will be stored in a fume hood, while the full simulant will be stored in a sealed Parr vessel for safety; no other simulants (RWCM/ RWCM+) will be stored at ambient temperature for this test. Samples will be analyzed by UGA in this manner on each Analysis Day outlined in Table 2. Analytical Data. The UGA measures the partial pressures in a single sample aliquot over a set mass range of 0-105 atomic mass units (AMU) [Figure 2]; this set range was selected to slightly exceed the mass of the highest-mass expected reaction product (H2SO4). The Baratron complements the UGA by measuring the total pressure in the headspace of a sample vial. Coupled together, the quantitative abundances of gases will be monitored throughout the test. UGA analyses of the triplicate samples for each storage temperature, day, and simulant composition will be averaged, and standard deviations for each will be calculated. The compositions of starting species (shown in Table 1) will be characterized as a function of time, and the presence of any new compounds (reaction products) will be monitored as well. Total pressures will be recorded for each sample analysis, and any samples that show signs of leakage (e.g., a significant reduction in pressure or simulant volatiles) will be discarded. Anticipated Results. Testing is planned to begin in January 2022. The resulting data will allow compositional and phase changes in the volatile component of the simulants to be determined. Both the reduction in initial compounds and the addition of reaction products are expected to be observed. In addition, the relative efficacy of the different temperatures at pre-serving the initial composition of the simulants will be quantified. Finally, the regolith component of each sample will be argon-purged and stored in a controlled environment for future laboratory analysis. Compositional and morphological changes in the regolith are expected for samples above 0°C. This test will be repeated three times over the course of 2022. Understanding the effect of temperature on both the volatile and regolith components of analog lunar materials will allow requirements for a cold stowage freezer to be developed. The implementation of cold stowage for lunar polar missions will maximize the preservation of returned samples, enabling ground-breaking lunar and Solar System volatiles science for decades to come.

J L Mitchell↗

Low Molecular Weight Volatile Organic Compounds Indicate Grazing by the Marine Rotifer Brachionus plicatilis on the Microalgae Microchloropsis salina

Microalgae produce specific chemicals indicative of stress and/or death. The aim of this study was to perform non-destructive monitoring of algal culture systems, in the presence and absence of grazers, to identify potential biomarkers of incipient pond crashes. Here, we report ten volatile organic compounds (VOCs) that are robustly generated by the marine alga, Microchloropsis salina, in the presence and/or absence of the marine grazer, Brachionus plicatilis. We cultured M. salina with and without B. plicatilis and collected in situ volatile headspace samples using thermal desorption tubes over the course of several days. Data from four experiments were aggregated, deconvoluted, and chromatographically aligned to determine VOCs with tentative identifications made via mass spectral library matching. VOCs generated by algae in the presence of actively grazing rotifers were confirmed via pure analytical standards to be pentane, 3-pentanone, 3-methylhexane, and 2-methylfuran. Six other VOCs were less specifically associated with grazing but were still commonly observed between the four replicate experiments. Through this work, we identified four biomarkers of rotifer grazing that indicate algal stress/death. This will aid machine learning algorithms to chemically define and diagnose algal mass production cultures and save algae cultures from imminent crash to make biofuel an alternative energy possibility.

headspace sampling↗

Comparing π‐complexation capabilities of ionic liquids containing silver(I) and copper(I) ions by headspace single drop microextraction in combination with high‐performance liquid chromatography

Selective π‐complexation capabilities of silver(I) and copper(I) ions can be effectively facilitated in ionic liquids. To understand the effects of environmental factors that influence the π‐complexation of these metal ions with analytes, techniques that employ small volumes of ionic liquid that can be readily analyzed are desired. In this study, headspace single drop microextraction coupled with HPLC is used to investigate a diverse set of environmental factors on the metal ion‐mediated complexation with aromatic compounds in ionic liquid media. Silver(I) and copper(I) bis[(trifluoromethyl)sulfonyl]imide salts were both studied by dissolving them in the 1‐decyl‐3‐methylimidazolium bis[(trifluoromethyl)sulfonyl]imide ionic liquid and employing the mixture as extraction media for aromatic compounds. Water and acetonitrile within the sample solution were observed to interfere with the complexation of silver(I) ions and aromatic compounds, while ethylene glycol and triethylene glycol did not. The temperature and extraction times were optimized to fully facilitate the π‐complexation capabilities of metal ions in ionic liquid media. Partition coefficients between the sample headspace and metal ion were determined using a three‐phase equilibria model. Although no discernable difference in analyte partitioning between the headspace and ionic liquid solvent was observed, analyte partition coefficients to silver(I) ion tended to be greater compared to copper(I) ion.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of Long-Path Gas Cell Assisted Infrared Spectroscopy for Detection of Lunar Volatiles and Advanced Curation Efforts

The motivation behind analyzing gaseous samples from the Permanently Shadowed Regions (PSRs) on the lunar surface is built upon the volatiles observed during the LCROSS mission. Advanced curation techniques under cold conditions are essential to the critical scientific analysis of these returned samples. The detection of various volatiles in returned samples by gas-phase infrared (IR) spectroscopy is known to be a powerful tool to understand the resources present in planetary bodies and Astro-materials. The identification and quantification of volatile compounds in returned planetary samples and regolith simulants by advanced and custom-built analytical devices are areas of primary research interest in our group and the Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility. In this context, we discuss recent advancements and experimental results for quick analysis of the major volatiles detected by the LCROSS (water, CO 2 , CH 3 OH, and NH 3 ) by a long-path gas cell/FTIR (Fourier Transform Infrared) spectrometer system. The applicability of this system is demonstrated by qualitative analysis of a series of volatiles measured individually. In addition, the linear dependence of absorption intensity on headspace sample volumes was checked by measuring gas-phase IR absorption spectra of increasing volumes of pure CO 2 gas aliquots. Finally, the instrument performance was evaluated by measuring the relative concentration of NH 3 (g) in methanol solution.

Curation↗

Design of an Online Electrochemical Mass Spectrometry System to Study Gas Evolution from Cells with Lean and Volatile Electrolytes

Gas evolution in high-energy Li-ion batteries remains a pervasive problem for a multitude of chemistries, jeopardizing the electrochemical performance and safety for consumers of electric vehicles. Many electrode–electrolyte degradation processes evolve gasses that may be detected in-situ with online electrochemical mass spectrometry (OEMS). In this work, details are provided for the setup and validation of an OEMS system that operates well under lean and volatile electrolyte conditions. Quite notably, the OEMS cells with only 40 µL of electrolyte and intermittent headspace sampling exhibit comparable electrochemical performance to flooded coin-cells. It is demonstrated that the onset time, shape, and magnitude of the gas evolution profiles calculated from mass spectrometer measurements match well to a known pressure reference through the use of an empirically determined fraction of removal. The off-gassing characteristics from a set of layered-oxide materials, NMC532, NMC811, and LNO, are used to further validate the OEMS setup against the literature. It is shown that many of the features present in the OEMS curves for equivalent systems from other groups are captured by this OEMS system. Finally, at an upper cut-off voltage of 4.4 V, LNO exhibits an intense release of CO 2 , O 2 , and CO gas relative to NMC532 and NMC811.

25 ENERGY STORAGE↗

Cryo-GCMS Outgassing Screening: Thermal Filler Materials

A study was conducted to investigate the outgassing characteristics of four thermal filler materials. The purpose of this screening was to identify any outgassing products that might be considered reactive, specifically compounds that could result in corrosion in the systems where these materials are used. A range of compounds was observed in the sample headspaces, though most do not stand out as being known reactive species of concern. However, several halogenated compounds and sulfurous compounds- classes compounds known to facilitate corrosion reactions under certain conditions- were observed in low concentrations. The TFLEX 760 exhibited the highest total outgassing, while the GR130 had the lowest. Therm-a-Gap75 and the Si thermal grease exhibited very similar outgassing profiles. It is difficult to predict the extent to which any given compound observed in an analysis of this type might pose a risk in an actual system; factors such as temperature, system geometry, concentration, and gas conductance all play a role in the kinetics governing chemical reactions. It is recommended that the results of these analyses are shared with pertinent materials SMEs familiar with the system(s) in question to evaluate potential risks.

36 MATERIALS SCIENCE↗

Peroxide-modified titanium dioxide: a chemical analog of putative Martian soil oxidants

Hydrogen peroxide chemisorbed on titanium dioxide (peroxide-modified titanium dioxide) is investigated as a chemical analog to the putative soil oxidants responsible for the chemical reactivity seen in the Viking biology experiments. When peroxide-modified titanium dioxide (anatase) was exposed to a solution similar to the Viking labeled release (LR) experiment organic medium, CO2 gas was released into the sample cell headspace. Storage of these samples at 10 degrees C for 48 hr prior to exposure to organics resulted in a positive response while storage for 7 days did not. In the Viking LR experiment, storage of the Martian surface samples for 2 sols (approximately 49 hr) resulted in a positive response while storage for 141 sols essentially eliminated the initial rapid release of CO2. Heating the peroxide-modified titanium dioxide to 50 degrees C prior to exposure to organics resulted in a negative response. This is similar to, but not identical to, the Viking samples where heating to approximately 46 degrees C diminished the response by 54-80% and heating to 51.5 apparently eliminated the response. When exposed to water vapor, the peroxide-modified titanium dioxide samples release O2 in a manner similar to the release seen in the Viking gas exchange experiment (GEx). Reactivity is retained upon heating at 50 degrees C for three hours, distinguishing this active agent from the one responsible for the release of CO2 from aqueous organics. The release of CO2 by the peroxide-modified titanium dioxide is attributed to the decomposition of organics by outer-sphere peroxide complexes associated with surface hydroxyl groups, while the release of O2 upon humidification is attributed to more stable inner-sphere peroxide complexes associated with Ti4+ cations. Heating the peroxide-modified titanium dioxide to 145 degrees C inhibited the release of O2, while in the Viking experiments heating to this temperature diminished but did not eliminated the response. Although the thermal stability of the titanium-peroxide complexes in this work is lower than the stability seen in the Viking experiments, it is expected that similar types of complexes will form in titanium containing minerals other than anatase and the stability of these complexes will vary with surface hydroxylation and mineralogy.

Review↗

Scientific Value of Including an Atmospheric Sample as Part of Mars Sample Return (MSR)

The Perseverance rover is meant to collect samples of the martian surface for eventual return to Earth. The headspace gas present over the solid samples within the sample tubes will be of significant scientific interest for what it reveals about the interactions of the solid samples with the trapped atmosphere and for what it will reveal about the martian atmosphere itself. However, establishing the composition of the martian atmosphere will require other dedicated samples. The headspace gas as the sole atmospheric sample is problematic for many reasons. The quantity of gas present within the sample tube volume is insufficient for many investigations, and there will be exchange between solid samples, headspace gas, and tube walls. Importantly, the sample tube materials and preparation were not designed for optimal Mars atmospheric gas collection and storage as they were not sent to Mars in a degassed evacuated state and have been exposed to both Earth's and Mars' atmospheres. Additionally, there is a risk of unconstrained seal leakage in transit back to Earth, which would allow fractionation of the sample (leak-out) and contamination (leak-in). The science return can be improved significantly (and, in some cases, dramatically) by adding one or more of several strategies listed here in increasing order of effectiveness and difficulty of implementation: (1) Having Perseverance collect a gas sample in an empty sample tube, (2) Collecting gas in a newly-designed, valved, sample-tube-sized vessel that is flown on either the Sample Fetch Rover (SFR) or the Sample Retrieval Lander (SRL), (3) Adding a larger (50-100 cc) dedicated gas sampling volume to the Orbiting Sample container (OS), (4) Adding a larger (50-100 cc) dedicated gas sampling volume to the OS that can be filled with compressed martian atmosphere.

Timothy D. Swindle↗

Radiolytic Gas Generation and Pressure Buildup in a Closed System Containing Mo-99 Solution

This study measured radiolytic gas generation and pressure buildup in a sealed stainless-steel system containing alkaline Mo-99 solution with added sodium nitrate as a hydrogen suppressant. In each of two experiments, approximately 200 Ci of Mo-99 solution was transferred into a closed experimental vessel inside a hot cell, isolated, and monitored for pressure rise caused by gas generation during radioactive decay. After pressure buildup, headspace gas samples were collected and analyzed by mass spectrometry to determine hydrogen and oxygen concentrations. The purpose was to quantify the magnitude of pressure buildup in a closed system and to characterize the gas composition produced by radiolysis of the Mo-99 target solution under representative handling and storage conditions. The two experiments used similar total Mo-99 activity but differed in solution volume, headspace volume, and leak integrity. In the first experiment, 197.5 Ci of Mo-99 in 16.92 mL of solution was loaded into a vessel with a 31.1-mL headspace; a small leak was later identified, and the measured peak pressure of 46 psig was extrapolated to about 70 psig in the absence of leakage. The headspace gas from this experiment contained about 21.4% H2 and 63.4% O2, but the composition was influenced by preferential hydrogen loss through the leak. In the second experiment, 193 Ci of Mo-99 in 5.41 mL of solution with 0.46 g NaNO3 was loaded into a vessel with a larger 42.61 mL headspace, and no detectable leak was observed. This experiment reached a peak pressure of 38 psig, and the measured gas composition was approximately 28.2% H2 and 51.5% O2. Because the second experiment was leak-free, it is considered the more reliable indicator of the true pressure buildup and intrinsic radiolytic gas composition of the Mo-99 solution.

Chemerisov, Sergey D.↗

Analysis of Respirator Cartridge Performance Testing on Hanford Tank A-101

Washington River Protection Solutions (WRPS) conducted tests on two types of chemical cartridges for use in air purifying respirators (APR) to determine the period of time that the cartridges would provide adequate performance1 to protect workers when exposed to a mixture of Chemicals of Potential Concern (COPCs) from vapors emanating from the headspace of tank A-101 on the Hanford Site. The Occupational Safety and Health Administration (OSHA) identifies cartridge testing as a valid approach for establishing a cartridge change schedules.[3] Testing is commonly applied in situations where mixtures of COPCs exist, and where other approaches, such as manufacturer recommendations and modeling, are less reliable. The tests were designed and conducted to ensure measurement and/or control of the key variables OSHA identified as important to estimate cartridge service life, including temperature, humidity, COPC concentration, breathing rate, and cartridge adsorption capacity. Testing was conducted over a period from July 22-24, 2016, using headspace vapors from Hanford tank A-101 under static conditions2 fed to a respirator cartridge test stand developed by WRPS in collaboration with HiLine Engineering (Richland, Washington). Multipurpose respirator cartridges, SCOTT 7422-SD1 and 7422-SC1 (SCOTT Safety, Monroe, North Carolina) were assessed on separate days with A-101 headspace vapors. Sample media (sorbent tubes) were used to collect samples of the vapor stream entering and exiting the respirator cartridge, and were subsequently analyzed for COPC concentrations. Pacific Northwest National Laboratory was tasked with conducting an independent analysis of the analytical results and making recommendations based on the results for respiratory cartridge performance and service life. Key conclusions from the assessment of the 59 COPCs in this study are described below: • Based on d measured cartridge inlet vapor concentrations from tank A-101 headspace, both ammonia and N-Nitrosodimethylamine (NDMA) exceeded their Occupational Exposure Limits (OEL).3 These measurements were generally consistent with maximum A-101 headspace measurements previously obtained for these two compounds. • Ammonia had respirator cartridge outlet concentrations that exceeded 10% of the OEL for both cartridges tested, indicating breakthrough for each. For the SCOTT 7422-SD1 cartridge, ammonia appeared to breakthrough above 10% of its OEL after 2 hours. For the SCOTT 7422-SC1 cartridge, ammonia breakthrough appeared to occur after 8 hours. 1 “Adequate performance” refers to the breakthrough criteria used in this analysis—that is, sustained cartridge outlet concentrations above 10% of the OEL. For some COPCs, an alternate threshold has been applied when necessary due to higher detection limit (DL)/reporting limit (RL) values for specific compounds. Ultimately, Industrial Hygiene professionals will use these results along with specific hazard assessments to determine service life and cartridge use that provides the necessary performance. 2 These tests were conducted under static conditions absent waste-disturbing activities in the subject tank or tank farm. 3 Occupational Exposure Limits accepted for Hanford Tank Farm use are based on OELs established by a U.S. governmental agency or national professional organization (e.g., OSHA, National Institute for Occupational Safety and Health, American Conference of Governmental Industrial Hygienists), or if no U.S. OEL exists, standard toxicological practices are applied to develop OELs using non-U.S. exposure limits, other established OELs for chemical surrogates when available, or other standard procedures. The OEL for NDMA was established in 2005 based on the MAK (Maximale Arbeitsplatzkonzentration) Commission standard adopted in Europe. iv • Despite respirator inlet measurements for NDMA that were in excess of its OEL, all corresponding outlet measurements, from both respirator cartridges, were below analytical DL 1 for the

61 RADIATION PROTECTION AND DOSIMETRY↗

Mercury Methylation and Soil Organic Matter Degradation in Incubations with Added Acetate, Isotope-Labeled Mercury, and Selective Microbial Inhibitors, Teller and Council Sites, Seward Peninsula, 2018-2019

This dataset provides the results of laboratory soil microcosm incubation experiments conducted under anaerobic conditions with added acetate, isotope-labeled mercury, and selective microbial inhibitors (2-bromoethanesulfonate and sodium molybdate). The microcosms contained soil collected in August 2018 from the NGEE Arctic Teller Road Site at mile marker 27 (TL_MM27) near Intensive Site 9 (TL_IS_9) and from the Council Road Site (CN_MM71). Incubations were conducted at 8°C for 180 days (Teller incubations) or 60 days (Council incubations). The microcosm headspace was sampled at designated intervals for greenhouse gas concentrations, then destructively harvested and extracted using ultrapure water and 0.1 M KCl for analysis of the porewater geochemistry. This dataset contains one pdf, two csv data files, and one zipped file with raw data.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Mars Sample Receiving Facility Research and Development to Enable Preservation, Safe Containment, and Scientific Research of Martian Samples on Earth

NASA and ESA are working together to plan a joint campaign to potentially bring back the first Martian samples to Earth in the early 2030s. On the surface of Mars, the Mars 2020Perseverance Rover is selecting and packaging samples that could be returned to Earth for careful examination by an international team of scientists. In preparation for this historic sample return, advance planning is underway to design and build a Mars Sample Receiving Facility (SRF) in the mid-2020s. In 2022, a Mars Sample Receiving Facility Assessment Study(MSAS) will be conducted to further define construction modality and capability options for a facility in the conterminous United States. Since Mars Sample Return (MSR) is currently categorized as a planetary protection restricted Earth return, this new facility would feature biosafety level 4 (BSL-4)-like high containment to protect Earth’s biosphere from any potential hazard. In addition, the facility also requires integration of cleanroom technologies to mitigate against terrestrial contamination and preserve sample integrity for science investigations. The integration of both clean handling and high containment requires significant technology research and development (R&D) by the mid-2020s to support the definition and planning of a SRF before commencing the site specific design phase. The SRF project will need to solidify the inorganic, organic, and biological contamination control (CC) requirements for the facility. This could entail a translation of Mars 2020 mission CC requirements for geologic material to engineering requirements for surfaces and airborne molecular contamination inside isolators and cleanrooms. In tandem, the project will need to determine precision cleaning and sterilization approaches for cleanrooms, isolators, equipment, and tools. Initial material selections for the facility construction materials, cleanrooms, isolators, and BSL-4 suits/garments are an important activity. The recent construction of the OSIRIS-REx and Hayabusa2 curation cleanroom laboratories greatly benefited from early materials testing, before the design phase, to reduced organic outgassing and particulate shedding inside the laboratory. While the early biohazard investigations in the SRF may deem the samples safe to release to laboratories throughout the world, sterilization methods need to be defined to safely release Martian samples. One key aspect of enabling simultaneous sample containment and cleanliness is the concept of a Double-Walled Isolator (DWI) that ESA has been pursuing. Further R&D is needed about DWIs, sample handling, and instrumentation interfaces before beginning the SRF site specific design phase. A working isolator/DWI engineering model should be developed and fabricated. Isolator sizes, connections, pass-through antechambers, and configurations and basic interfaces with instruments and tools as well as the use of robotic, mechanical, and/or human manipulation need to be considered. Inert high purity gas supply (one-pass or recirculation) and other isolator utilities must be determined. Special accommodations for large instruments (e.g., XCT,SEM, etc.) need to be developed. Techniques for opening the sample tubes packaged by M2020and extracting the headspace gas while keeping samples pristine will be challenging, requiring additional R&D, and engagement of the M2020 project. In addition, careful micromanipulation for subdivision and packaging of samples will also need to be included. These combined R&D activities are important before commencing the SRF design phase to ensure safe biohazard containment, sample preservation, and science integrity for the samples that would be studied in the SRF and in laboratories around the world.

mars sample return↗

Study of Poly(ether ketone ketone) (PEKK): Outgassing Characteristics and Likely Residual Synthesis Impurities

In May-June, 2020, a study was conducted to characterize the outgassing properties of a series PEKK (Poly(ether ketone ketone)) samples using cryo-GC/MS headspace analysis. Three sets of samples were interrogated: sample group 1 consisted of 2 additively manufactured PEKK samples (PEKK "ole and "New") prepared by KCNSC from powder material from Solvay Specialty Polymers USA, LLC. Sample groups 2 and 3 consist of 5 PEKK powder types (used as feedstock for additive manufacturing processes) and 4 additively-manufactured PEKK material lots, respectively. Contrary to expectations, all samples of PEKK material were observed to outgas sulfur-containing compounds. Other analyses (EDS/EMA, GC-TOF/MS of PEKK sample extractions) confirmed the presence of sulfur in the PEKK bulk material. Specifically, Diphenyl sulfone (used as a reagent or high-temperature solvent in the synthesis of Polyaryletherketone or PAEK polymers) was observed in three of the powders and in both the PEKK "Old" and "New" samples, suggesting that the source of the sulfur can be traced to impurities in the material left over from the synthesis process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Study of the Curation Protocol by Sample Analysis Working Team (SAWT) in Martian Moons eXploration (MMX) Project

Japan Aerospace Exploration Agency (JAXA) will launch a spacecraft in 2024 for a sample return mission from Phobos (Martian Moons eXploration: MMX). The major scientific goals of MMX are to constrain (1) the origin of Phobos and Deimos and (2) the evolution of the Mars-moon system [1]. The touchdown operations are planned to be performed twice at different landing sites on the Phobos surface to collect > 10 g of the surface materials [2]. After the return to the Earth, the Phobos samples will be collected from the individual sample canisters and introduced to the clean chamber installed at ISAS (Institute of Space and Astronautical Science). The Sample Analysis Working Team (SAWT) of MMX designed the procedure of Phobos sample analysis mainly conducted by the initial analysis teams [3]. For the next step, the SAWT will define the procedure of the curation process (mostly non-destructive analysis) of the Phobos samples, which will be presented here. The protocols of the Phobos sample curation is illustrated in figure 1. First, the headspace gas from the sample container will be collected during the Quick Analysis phase. The Quick Analysis will be operated by the sampler and curation teams in ISAS/JAXA. The terrestrial leak and contamination from the sampling systems will be tested using a quadrupole mass spectrometer equipped with a gas sampling system. Second, the bulk Phobos sample will be observed in the clean chamber under purified-N2 gas with an ambient condition (Pre-basic Characterization). This phase will be operated by the curation team in ISAS/JAXA and the instrument team of the MMX mission. The consistency between the data from the instruments in the clean chamber and the spacecraft will then be evaluated. Subsequently, the curation will distribute the small amount of Phobos samples to the Initial analysis team of MMX to conduct the "Preliminary Examination". The objectives of the preliminary examination are to provide (1) feedback on the subsequent sample allocation process, (2) preliminary scientific results that will address parts of MMX mission goals, and (3) evaluation of the sampling system and terrestrial alteration on Phobos samples. Because multiple models are proposed for the origin of Phobos [1] (e.g., giant impact, the capture of asteroids), the chemical and mineralogical characteristics of Phobos must be assessed before the allocation of the samples to the individual initial analysis teams. Simultaneously, the curation team in JAXA will observe the individual grains and aliquots of the samples in the clean chamber (Basic Characterization).

R Fukai↗