Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT LOSSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effect of neutral collision and radiative heat-loss function on self-gravitational instability of viscous thermally conducting partially-ionized plasma

The problem of thermal instability and gravitational instability is investigated for a partially ionized self-gravitating plasma which has connection in astrophysical condensations. We use normal mode analysis method in this problem. The general dispersion relation is derived using linearized perturbation equations of the problem. Effects of collisions with neutrals, radiative heat-loss function, viscosity, thermal conductivity and magnetic field strength, on the instability of the system are discussed. The conditions of instability are derived for a temperature-dependent and density-dependent heat-loss function with thermal conductivity. Numerical calculations have been performed to discuss the effect of various physical parameters on the growth rate of the gravitational instability. The temperature-dependent heat-loss function, thermal conductivity, viscosity, magnetic field and neutral collision have stabilizing effect, while density-dependent heat-loss function has a destabilizing effect on the growth rate of the gravitational instability. With the help of Routh-Hurwitz's criterion, the stability of the system is discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of radiation heat loss on planar and spherical hydrofluorocarbon/air flames

Hydrofluorocarbons (HFC), which are mildly flammable and pose potential fire risks, have received greater attention as a viable low global warming potential alternative to traditional refrigerant and fire-suppressant compounds. Therefore, there is a demand to accurately quantify their flammability and re-activity to establish proper safety metrics. Here, this study investigates the effects of radiation heat loss on slowly-propagating HFC/air laminar flames. Planar 1-D simulations of R-32/air and R-1234yf/air flames show significant reductions in laminar flame speed due to radiative heat losses from the flame zone. Simulations of spherically expanding flames (SEF) revealed that the radiation-induced flow needs to be considered when interpreting data from experiments. To this end, a Spherical-flame RADiation-Induced Flow (SRADIF) model was developed to estimate the burned gas inward flow velocities in constant-pressure SEFs, utilizing the optically thin limit assumption to model radiation heat loss. The model was validated against results from detailed numerical simulations of SEFs, from which radiation-induced inward flow was derived using a new formulation considering both the radiation heat loss and convective flow effects. Results show that SRADIF accurately predicts the inward flow velocity for R-32/air mixtures over a range of conditions and performs significantly better compared to existing analytical models. However, the model was unable to accurately predict flow velocities for R-1234yf/air flames and the reason for this is discussed. (224 words)

42 ENGINEERING↗

On the Influence of a Fuel Side Heat-Loss (Soot) Layer on a Planar Diffusion Flame

A model of the response of a diffusion flame (DF) to an adjacent heat loss or 'soot' layer on the fuel side is investigated. The thermal influence of the 'soot' or heat-loss layer on the DF occurs through the enthalpy sink it creates. A sink distribution in mixture-fraction space is employed to examine possible DF extinction. It is found that (1) the enthalpy sink (or soot layer) must touch the DF for radiation-induced quenching to occur; and (2) for fuel-rich conditions extinction is possible only for a progressively narrower range of values ot the characteristic heat-loss parameter, N(sub R)(Delta Z(sub R)) Various interpretations ot the model are discussed. An attempt is made to place this work into the context created by previous experimental and computational studies.

Wichman, Indrek S.↗

Effects of radiative heat loss on extinction limits of counterflow premixed ammonia-air flames

The effect of radiative heat loss on counterflow premixed ammonia-air flames has been investigated as a function of equivalence ratio and system pressure. Non-adiabatic counterflow premixed flame simulations incorporating detailed chemistry, transport, and radiative heat transfer in the optically thin limit have been employed to elucidate important underlying physics and extinction characteristics. Similar to methane-air flame systems, non-adiabatic counterflow premixed computations show that the combined effects of positive flame stretch, sub-unity Lewis number, and radiative heat loss lead to the extension of the lean flammability limit for ammonia-air flames, revealing a C-shaped curve near the lean flammability limit that exhibits both radiation-induced and stretch-induced extinction states. Here, the computations compare favorably with the experimentally determined extinction stretch rate values for the stretch-induced extinction states over a wide range of equivalence ratios at different pressures up to 5 atm. A novel feature sensitivity analysis has also been developed to highlight important sensitive reactions for the stretch- and radiation-induced extinction states. Furthermore, the controlling chemistry at the dual-extinction states and at varying pressures are compared and discussed.

10 SYNTHETIC FUELS↗

Heat Loss Effects on Emissions in an NH 3 RRQL Combustor

Ammonia (NH 3 ) is a carbon-free energy carrier with an infrastructure for production, storage, and distribution. There is interest in direct NH 3 combustion, but managing pollutant emissions is a key challenge, particularly nitric oxides (NO x ) due to the fuel-bound nitrogen atom, nitrous oxide (N 2 O), which is a potent greenhouse gas, and unburned NH 3 , which is harmful to humans and the environment. Rich staged combustor concepts with extended primary residence times (τ res,primary ), like Rich-Relax- Quick-mix-Lean (RRQL), offer a viable pathway for direct NH 3 combustion with low levels of NO x formation. However, minimizing secondary emissions such as N 2 O and unburned NH 3 and hydrogen (H 2 ) remains a critical challenge. Prior atmospheric-pressure studies have demonstrated that RRQL operation with sufficiently long τ res,primary enables substantial NO x relaxation and promotes NH 3 cracking to H 2 , if heat losses from the relaxation stage are limited. However, the combined influence of elevated pressure and long residence time on RRQL performance has not been explored. The present work examines RRQL operation at pressures up to 5 bar and elevated τ res,primary . Exhaust measurements of NO x , NH 3 , and N 2 O are used to quantify the extent of NO x relaxation and NH 3 cracking under nonadiabatic conditions. To contextualize and quantify the effects of heat losses in the experimental data, chemical reactor networks (CRNs) incorporating prescribed heat loss rates are employed to assess the sensitivity of emissions to thermal losses in the relaxation stage. Collectively, the results demonstrate that management and quantification of heat losses are essential to preserve NO x relaxation and limit NH 3 and N 2 O emissions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiative Heat Loss Measurements During Microgravity Droplet Combustion in a Slow Convective Flow

Radiative heat loss from burning droplets in a slow convective flow under microgravity conditions is measured using a broad-band (0.6 to 40 microns) radiometer. In addition, backlit images of the droplet as well as color images of the flame were obtained using CCD cameras to estimate the burning rates and the flame dimensions, respectively. Tests were carried out in air at atmospheric pressure using n-heptane and methanol fuels with imposed forced flow velocities varied from 0 to 10 centimeters per second and initial droplet diameters varied from 1 to 3 millimeters. Slow convective flows were generated using three different experimental configurations in three different facilities in preparation for the proposed International Space Station droplet experiments. In the 2.2 Second Drop-Tower Facility a droplet supported on the leading edge of a quartz fiber is placed within a flow tunnel supplied by compressed air. In the Zero-Gravity Facility (five-second drop tower) a tethered droplet is translated in a quiescent ambient atmosphere to establish a uniform flow field around the droplet. In the KC 135 aircraft an electric fan was used to draw a uniform flow past a tethered droplet. Experimental results show that the burn rate increases and the overall flame size decreases with increases in forced-flow velocities over the range of flow velocities and droplet sizes tested. The total radiative heat loss rate, Q(sub r), decreases as the imposed flow velocity increases with the spherically symmetric combustion having the highest values. These observations are in contrast to the trends observed for gas-jet flames in microgravity, but consistent with the observations during flame spread over solid fuels where the burning rate is coupled to the forced flow as here.

Hicks, Michael C.↗

Extinction of the Stagnation Point Diffusion Flame: Effect of Conductive Heat Loss into Solid Interior

The planned microgravity experiment Growth and Extinction Limit (GEL) is designed to study the material flammability and extinction of thermally thick solid with an emphasis to quantify the effect of conductive heat loss into the solid interior by measuring the in-depth temperature profile. To obtain a more detailed understanding of the extinction phenomena, a previously developed one-dimensional axisymmetric stagnation-point diffusion flame model is expanded to account for the excessive heat loss into the solid beyond the steady burning state. This is important because for thick solids, this is important because the burning period can have a long and slow solid transient with a quasi-steady gas -phase. A non-dimensional excessive conductive heat loss parameter Ψ is defined in the paper and extensive numerical computations have been performed to determine the extinction boundary and the characteristics of near-limit flames. The classical U-shaped flammability boundary in the oxygen vs. stretch rate plot now becomes a series of U-shaped boundaries as a function of Ψ. For a given oxygen ambient, extinction boundary is a function of Ψ. The boundary consists of a blowoff branch and a radiative quenching branch. This is similar to the steady burning flammability boundary (Ψ =0) in the oxygen vs stretch rate plot. Extensive computed data including flame and pyrolysis temperatures, burning rate, flame standoff distance, and reaction rate are presented along the extinction boundaries. In particular, we note that the non-dimensional gas reaction rate is the ratio of diffusion reaction time to the reaction diffusion time, so it has the classical Damhkoler number character. By examining the maximum non-dimensional reaction rates, we observe that along the extinction boundaries, they are approximate constant across the entire range of stretch rates (from quenching to blow-off). These critical values are of the order unity but may vary in different oxygen ambient. The implication will be discussed in the presentation together with the near-limit flame structures.

Chengyao Li↗

Effects of heat loss, preferential diffusion, and flame stretch on flame-front instability and extinction of propane/air mixtures

Flame configurations, flame-front cellular instability, and extinction of propane/air mixtures in the stagnation-point flow are experimentally studied for their dependence on downstream heat loss, preferential diffusion, and flame stretch. Boundaries for lean- and rich-limit extinction, stabilization of corrugated flames, and local extinction caused by sharp curvatures are mapped for varying propane concentrations and freestream velocities. Flame location and temperature at extinction are determined as functions of stagnation surface temperature, extent of preheating, propane concentration, and freestream velocity. Results substantiate the theoretical predictions of the different extinction modes for lean and rich flames in the absence of downstream heat loss, and yield useful insight on the extinction characteristics when finite downstream heat loss does exist. It is further shown that flame-front instability occurs only for rich mixtures in accordance with preferential diffusion considerations, and that flame stretch has a stabilizing effect such that flame-front instability is completely inhibited before the onset of extinction.

Ishizuka, S.↗

Heat Loss Testing of Schott's 2008 PTR70 Parabolic Trough Receiver

Two Schott 2008 model year PTR70 HCEs were tested on NREL's heat loss test stand from 100 - 500 deg C in 50 deg C increments. Absorber emittance was determined from the laboratory testing so that the performance of the HCEs could be modeled in a parabolic trough collector. Collector/HCE simulation results for many different field operation conditions were used to create heat loss correlationcoefficients for Excelergy and SAM. SAM estimates that the decreased emittance of the 2008 PTR70 will decrease the LCOE for parabolic trough power plants by 0.5 cents/kWh and increase the electricity generated by 5% relative to previous PTR70s. These conclusions assume that the 2008 PTR70 is supplied at the same cost and with the same optical performance as earlier PTR70 models.

14 SOLAR ENERGY↗

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator↗

Spacecraft Radiator Protection from Ionizing Radiation, Dust, and Excessive Heat Loss

Under a Phase II SBIR project funded by NASA Johnson Space Center (Contract No. 80NSSC25C0088), Analytical Scientific Products LLC (ASP) has been developing an actively controlled louver to protect spacecraft radiators from degradation due to exposure to various types of environmental conditions. Of particular interest are ionizing radiation during spacecraft transit through the Van Allen belts, dust during spacecraft landing and surface operations on the moon, and excessive heat loss during the long lunar night especially near the poles where the local ambient temperatures can drop below -200°C. Exposure to ionizing radiation and dust can degrade the optical properties of the radiator coating that in turn reduces its ability to reject excess heat from the spacecraft into the environment. Exposure to the extremely low temperature conditions during the lunar night near the poles can freeze the radiator fluids that can compromise the integrity of the radiator. Passive louvers constructed using thick aluminum vanes are used currently to protect spacecraft radiators from some of the above effects, but they have several drawbacks: (i) their high aerial density makes it impractical to scale them to protect the much larger spacecraft radiators needed for future manned missions to the moon and beyond, (ii) the bimetallic actuators used to open and close the vanes in passive louvers rely on external temperature alone and so the louver cannot offer protection from dust and ionizing radiation when the ambient temperatures are high, and (iii) the bimetallic actuators need time scales of the order of hours to open and close. We have addressed the above limitations of passive louvers through the development of a low aerial density and rapidly actuating actively controlled louver. It is constructed from a custom alloy that offers much higher levels of protection against the ionizing radiation, dust and excessive heat loss at a fraction of weight compared to passive louvers while providing opening and closing time scales of the order of a second. Our modular design makes it easy to scale the system up or down depending on the application. We have recently constructed a 31 inch × 31 inch module of this louver and tested its functionality and effectiveness. These tests have shown that the louver can be opened and closed in less than 2 s. It reduces the transmission of ionizing radiation by 78% to 100% (depending on the radiation source), dust transmission by more than 93%, and heat loss by more than 97%. We are currently preparing to evaluate this device at the Johnson Space Center’s cryogenic vacuum chamber where it can be subjected to simulated lunar surface conditions. This paper provides a detailed discussion of the test designs as well as the data from tests that demonstrate the effectiveness in reducing the transmission of ionizing radiation, dust, and heat under laboratory conditions.

Radiator↗

Directional solidification with heat losses

The upward directional solidification of a dilute binary alloy in a tall, thin, two-dimensional slot is considered. Heat losses from the sidewalls produce curved isotherms, interface deformations, and melt convection. An asymptotic approach is used which relates the small heat loss to the thinness of the solidification cell, and solutions are obtained for the resulting melt convection, interface deflection, and the distribution of heat and solute. The model is compared to the numerical results of Chang and Brown (1983) which exclude the effects of solute buoyancy and thermodynamic equilibrium at the interface. The radial segregation at the interface (consistent with both interface shapes and temperature fields) is computed, and it is found that the radial segregation is independent of interfacial shapes; the radial segregation cannot be calculated from only a knowledge of the interface shape.

Brattkus, K.↗

Experimentally-determined external heat loss of automotive gas turbine engine

An external heat balance was conducted on a 150 HP two-shaft automotive gas turbine engine. The engine was enclosed in a calorimeter box and the temperature change of cooling air passing through the box was measured. Cooling airflow ranges of 1.6 to 2.1 lb-per-second and 0.8 to 1.1 lb-per-second were used. The engine housing heat loss increased as the cooling airflow through the calorimeter box was increased, as would be the case in a moving automobile. The heat balance between the total energy input and the sum of shaft power output and various losses compared within 30 percent at engine idle speeds and within 7 percent at full power.

Meng, P. R.↗

A detailed experimental and modeling comparison of molecular radiative heat loss in a spark-ignition engine

Radiative heat transfer has been chiefly considered negligible in internal combustion engines, except for Diesel engines where soot radiation was recognized as a significant radiative transfer source. Only more recently, detailed simulations have shown that molecular radiation can be substantial as well. In extension to this, molecular radiative heat transfer can reach detectable levels of about 5–10% of the total heat transfer in spark-ignited engines. The broadband radiative nature of the significant emitting molecules, carbon dioxide and water, makes it necessary to address whether radiative trapping plays a substantial role in either total heat loss or energy redistribution within the cylinder. An experimental setup that allows measurements of the infrared emissions at a 2-crank-angle-degree resolution was developed to determine the importance of radiative trapping by carbon dioxide and water. Measurements were conducted in the well-characterized and documented TCC-III engine at the University of Michigan. The engine operated on a stoichiometric propane/air mixture at a speed of 1,300 RPM. Large Eddy Simulations with added line-by-line photon Monte-Carlo simulations of the molecular radiation were an integral part of this study to plan and devise the measurements. Post-processing of the simulation data included an accurate representation of the experimental volume from where infrared signals are collected. Additionally, the experimental data were used for validation of the photon Monte-Carlo simulations. Joint analysis of experimental and simulated spectra allowed quantifying the significance of radiative trapping. Results show the significant role of radiative trapping when predicting radiative heat transfer in the TCC-III engine.

42 ENGINEERING↗

Heat Loss Imagery

Infrared scanning devices are being used to produce images that show, by color or black-and-white shading differences, which buildings and homes are losing heat to the outdoors, and how much. Heat loss surveys done by Texas Instruments, Daedalus Enterprises, Inc. and other companies have growing acceptance of their services among industrial firms, utilities, local governments, and state and federal agencies interested in promoting heat loss awareness and inspiring corrective actions.

Source record↗

Comparison of Equivalent System Mass (ESM) and Modeling Results from Improved Heat Loss Approaches for the Carbon Dioxide Deposition (CDep) System

Proper insulation on any type of cryogenic system is essential for its performance to be optimal, as a poorly insulated system will allow for significant heat loss. Different insulation arrangements for CDep were considered, and performance was simulated and measured in Modelica. Heat loss was correlated to cycle time and CO2 deposition efficiency, which led to overall system power usage. Mass, volume, and power consumption were weighted accordingly in the ESM calculations to guide selection of the CDep insulation scheme.

Marian Alcid↗

1D Heat Loss Models Validation Experiment

Contains data from the model validation in the 1D Heat Loss Models to Predict the Aquifer Temperature Profile during Hot/Cold Water Injection Project. The data include two COMSOL models (2D axisymmetric benchmark model and 2D Vinsome model), one python code (1D Vinsome based FEM numerical simulation), one matlab main code (1D Newton analytical solution and all results comparison visualization), and output files generated from the above models.

1D↗