Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEAT LOSSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Alterations in heat loss and heat production mechanisms in rat exposed to hypergravic fields

A review of studies investigating the thermal response of rats exposed to hypergravic fields well below maximum tolerance levels is presented. It is concluded that several lines of evidence indicate that the neural switching network for temperature regulation and cardiovascular channeling of blood flow is transiently affected during the first hour a rat is exposed to hypergravity. Moreover, even after one hour of exposure, when the core temperature has fallen several degrees, shivering and nonshivering thermogenesis are not fully activated. Only after prolonged exposure to hypergravic fields do heat production mechanisms recover sufficiently to bring the core temperature back to a normal level. Thus, the data indicate a more rapid recovery of effector mechanisms for heat loss than for heat production.

Horowitz, J. M.↗

Generation of a Parabolic Trough Collector Efficiency Curve from Separate Measurements of Outdoor Optical Efficiency and Indoor Receiver Heat Loss

The thermal efficiency of a parabolic trough collector is a function of both the fraction of direct normal radiation absorbed by the receiver (the optical efficiency) and the heat lost to the environment when the receiver is at operating temperature. The thermal efficiency can be determined by testing the collector under actual operating conditions or by separately measuring these two components. This paper describes how outdoor measurement of the optical efficiency is combined with laboratory measurements of receiver heat loss to obtain the thermal efficiency curve. This paper describes this approach and also makes the case that there are advantages to plotting collector efficiency versus the difference between the operating temperature and the ambient temperature at which the receiver heat loss was measured divided by radiation to a fractional power (on the order of 1/3 but obtained via data regression) - as opposed to the difference between operating and ambient temperatures divided by the radiation. The results are shown to be robust over wide ranges of ambient temperature, sky temperature, and wind speed.

14 SOLAR ENERGY↗

Heat losses associated with the upward flow of air, water, CO 2 in geothermal production wells

This present work reports on the heat losses associated with the upward flow of hot air, water, and CO 2 in a production well. The heat losses considered here are the frictional heat loss, the gravitational heat loss, the Joule-Thomson effect, and the conduction heat loss to the surrounding rock formation. These heat losses were characterized using the mass flow rate, the operation time as variable parameters while the surrounding formation was assumed to have constant properties with a linear geothermal gradient. The results show that, the frictional heat loss was small while the influences of the others depended on the flow conditions and the operation time. For water, the Joule-Thomson effect was a heating effect and its magnitude was comparable to that due to the gravitational effect. The conduction heat loss was dominant for all situations. For air as well as CO 2 , the Joule-Thomson effects were the cooling effects. For low mass flow rates, the conduction heat loss was the dominant heat loss during the initial stages of the operation and the combined heat losses due to the gravitational and the Joule-Thomson effects became dominant during the later times. For high mass flow rates, throughout the operation life time, the gravitational and the Joule-Thomson effects were the dominant heat losses that control the temperature of air and CO 2 in the production well.

15 GEOTHERMAL ENERGY↗

Heat Loss Characteristics and Energy Use of Piperazine with the Advanced Stripper (PZAS) at the UT-SRP Pilot Plant

Heat duty and heat loss were measured at the pilot plant at UT Austin. Heat loss was measured with energy balances using water. Heat loss was studied using surface temperature measurements over 68 different locations at the pilot plant. Surface temperature measurements indicated that bare metal surfaces were the primary source of heat loss from the pilot plant. Heat loss from bare metal surfaces was at least 50% controlled by natural convection and in many cases was as high as 75% natural convection controlled. Measured heat loss at the pilot plant was 20100 BTU/hr and overall heat loss did not show any dependence on the heat rate of the plant. Compared to PZAS™ at the National Carbon Capture Center, heat loss relative to heat rate was higher at 38%. The relative heat loss at the pilot plants was found to decrease by 20% per MW of added capacity. Measured net heat duty was found to be dependent on measured lean loading and cold rich bypass flow rate. Measured net heat duty was between 2.2 and 2.4 GJ/tonne at an optimum lean loading of 0.2–0.21 mol/mol. Data reconciliation by Aspen Plus® Data Fit™ underpredicted CO2 flow rate by 20% due to an overprediction of lean loading by 19%, indicating a necessary change in thermodynamic parameters in the model. This resulted in an over prediction of heat duty by 33% on average.

Amine scrubbing, stripper, energy requirement, hea↗

Modeling Heat Loss through Piston and Effects of Thermal Boundary Coatings in Diesel Engine Simulations using Conjugate Heat Transfer models

Heat loss through wall boundaries play a dominant role in the overall performance and efficiency of internal combustion engines. Typical engine simulations use constant temperature wall boundary conditions. These boundary conditions cannot be estimated accurately from experiments due to the complexities involved with engine combustion. As a result they introduce a large uncertainty in engine simulations and serve as a tuning parameter. Modeling the process of heat transfer through the solid walls in an unsteady engine computational fluid dynamics (CFD) simulation can lead to the development of higher fidelity engine calculations. These models can be used to study the impact of heat loss on engine efficiency and explore new design methodologies that can reduce heat losses. In this work, a single cylinder diesel engine is modeled along with the solid piston coupled to the fluid domain. Conjugate heat transfer (CHT) modeling techniques were implemented to model heat losses for a full cycle of a Navistar diesel engine. This CFD model is then validated against experimental data available from thermocouples embedded inside the piston surface. The overall predictions from the model match closely with the experimental observations. The validated model is further used to explore the benefits of thermal barrier coatings (TBC) on piston bowls. The effect of TBC coatings were modeled as a thermal resistance in the heat transfer models. Full cycle 3D engine simulations provide quantitative insights into heat loss and thus calculate the efficiency gain by the use of TBC coatings. The work establishes a validated modeling framework for CHT modeling in reciprocating engine simulations.

Kundu, Prithwish↗

Feasibility of determining flat roof heat losses using aerial thermography

The utility of aerial thermography for determining rooftop heat losses was investigated experimentally using several completely instrumented test roofs with known thermal resistances. Actual rooftop heat losses were obtained both from in-situ instrumentation and aerial thermography obtained from overflights at an altitude of 305 m. In general, the remotely determined roof surface temperatures agreed very well with those obtained from ground measurements. The roof heat losses calculated using the remotely determined roof temperature agreed to within 17% of those calculated from 1/R delta T using ground measurements. However, this agreement may be fortuitous since the convective component of the heat loss is sensitive to small changes in roof temperature and to the average heat transfer coefficient used, whereas the radiative component is less sensitive. This, at this time, it is felt that an acceptable quantitative determination of roof heat losses using aerial thermography is only feasible when the convective term is accurately known or minimized. The sensitivity of the heat loss determination to environmental conditions was also evaluated. The analysis showed that the most reliable quantitative heat loss determinations can probably be obtained from aerial thermography taken under conditions of total cloud cover with low wind speeds and at low ambient temperatures.

Bowman, R. L.↗

Feasibility of determining flat roof heat losses using aerial thermography

The utility of aerial thermography for determining rooftop heat losses is investigated. Actual rooftop heat losses were obtained both from in-situ instrumentation of test roofs with known thermal resistances and aerial thermography obtained from overflights at an altitude of 305 m. It is found that the roof heat losses calculated using the remotely determined roof temperature agreed to within 17% of those calculated from ground measurements. However it is noted that an acceptable quantitative determination of roof heat losses using aerial thermography is only feasible when the convective term is accurately known or minimized. In addition, the sensitivity of the heat loss determination to environmental conditions is also evaluated. Finally, the analysis shows that the most reliable determinations can probably be obtained under conditions of total cloud cover with low wind speeds and at low ambient temperatures.

Bowman, R. L.↗

An Analytical Methodology to Evaluate Thermal-Hydraulic Performance of Compact Heat Exchangers, Accounting for Heat Loss

High efficiency and compactness, offered by the Printed Circuit Heat Exchanger (PCHE) makes it a strong candidate for use as an Intermediate Heat Exchanger (IHX) and/or Secondary Heat Exchanger (SHX) for Advanced High Temperature Reactor (AHTR) systems and also the Very High Temperature Reactor (VHTR). Idaho National Laboratory (INL) has been developing a computer code for the PCHE design and analysis [1], and will construct an experimental loop to evaluate the thermal hydraulic performance of PCHEs [2]. In order to correctly compare experimental results with the simulations, the extraneous heat losses from the PCHEs must be determined and incorporated. These heat exchangers operate at high temperature and consequently, despite the use of external thermal insulation, experience non-negligible heat losses to the surroundings. The objective of this work is to develop an analytical methodology for quantification of these heat losses based on experimental data to evaluate and predict the performance of the heat exchanger accurately.

99 GENERAL AND MISCELLANEOUS↗

Effect of air path heat losses at different locations in vapor compression-based clothes dryer: Quasi-steady modeling and design implications

Clothes drying is among the most power-intensive household end uses, and vapor compression-based clothes dryers offer substantial energy cost savings compared with conventional electric heater dryers. However, parasitic heat losses along the air path, that is, heat loss at the upstream of the drum, inside the drum, and at downstream of the drum, remain rarely quantified, but can strongly affect overall performance according to experiments. Here, this study enhances a vapor compression simulation model by integrating a validated drum model using a dimensionless heat-and-mass-transfer effectiveness correlation derived from 63 drying tests in the literature to form a quasi-steady dryer simulation model. The model is validated against laboratory measurements of a baseline dryer. The impact of heat losses is simulated at three locations and explored through 16 heat loss cases spanning two loads (2 and 5 kg), two airflow rates, and multiple loss distributions. For a 5 kg wet load, eliminating pre-drum and in-drum losses reduces total energy use by up to 34–35% and shortens drying time by 27–38% compared with the baseline. At a 2 kg wet load, introducing post-drum heat loss lowers energy costs by up to 23% and reduces operation time by up to 57% compared with the baseline. The results demonstrate that the impact of heat loss is location dependent. Vapor compression dryers should minimize pre-drum and in-drum losses while potentially exploiting post-drum heat dissipation to enhance the drying rate and energy cost savings.

Dryer↗

Convection heat loss from cavity receiver in parabolic dish solar thermal power system: A review

The convection heat loss from cavity receiver in parabolic dish solar thermal power system can significantly reduce the efficiency and consequently the cost effectiveness of the system. It is important to assess this heat loss and subsequently improve the thermal performance of the receiver. This paper aims to present a comprehensive review and systematic summarization of the state of the art in the research and progress in this area. The efforts include the convection heat loss mechanism, experimental and numerical investigations on the cavity receivers with varied shapes that have been considered up to date, and the Nusselt number correlations developed for convection heat loss prediction as well as the wind effect. One of the most important features of this paper is that it has covered numerous cavity literatures encountered in various other engineering systems, such as those in electronic cooling devices and buildings. The studies related to those applications may provide valuable information for the solar receiver design, which may otherwise be ignored by a solar system designer. Finally, future development directions and the issues that need to be further investigated are also suggested. It is believed that this comprehensive review will be beneficial to the design, simulation, performance assessment and applications of the solar parabolic dish cavity receivers. (author)

14 SOLAR ENERGY↗

An improved model for natural convection heat loss from modified cavity receiver of solar dish concentrator

A 2-D model has been proposed to investigate the approximate estimation of the natural convection heat loss from modified cavity receiver of without insulation (WOI) and with insulation (WI) at the bottom of the aperture plane in our previous article. In this paper, a 3-D numerical model is presented to investigate the accurate estimation of natural convection heat loss from modified cavity receiver (WOI) of fuzzy focal solar dish concentrator. A comparison of 2-D and 3-D natural convection heat loss from a modified cavity receiver is carried out. A parametric study is carried out to develop separate Nusselt number correlations for 2-D and 3-D geometries of modified cavity receiver for estimation of convective heat loss from the receiver. The results show that the 2-D and 3-D are comparable only at higher angle of inclinations (60 {<=} {beta} {<=} 90 ) of the receiver. The present 3-D numerical model is compared with other well known cavity receiver models. The 3-D model can be used for accurate estimation of heat losses from solar dish collector, when compared with other well known models. (author)

14 SOLAR ENERGY↗

Influence of a Simple Heat Loss Profile on a Pure Diffusion Flame

The presence of soot on the fuel side of a diffusion flame results in significant radiative heat losses. The influence of a fuel side heat loss zone on a pure diffusion flame established between a fuel and an oxidizer wall is investigated by assuming a hypothetical sech(sup 2) heat loss profile. The intensity and width of the loss zone are parametrically varied. The loss zone is placed at different distances from the Burke-Schumann flame location. The migration of the temperature and reactivity peaks are examined for a variety of situations. For certain cases the reaction zone breaks through the loss zone and relocates itself on the fuel side of the loss zone. In all cases the temperature and reactivity peaks move toward the fuel side with increased heat losses. The flame structure reveals that the primary balance for the energy equation is between the reaction term and the diffusion term. Extinction plots are generated for a variety of situations. The heat transfer from the flame to the walls and the radiative fraction is also investigated, and an analytical correlation formula, derived in a previous study, is shown to produce excellent predictions of our numerical results when an O(l) numerical multiplicative constant is employed.

Ray, Anjan↗

The effects of radiative heat loss on microgravity flame spread

The effect of radiative heat loss from the surface of a solid material burning in a zero gravity environment in an opposed flow is studied through the use of a numerical model. Radiative heat loss is found to decrease the flame spread rate, the boundary layer thickness, and pyrolysis lengths. Blowoff extinction is predicted to occur at slower opposesd flow velocities than would occur if the radiative loss is not present. The radiative heat fluxes are comparable to the conduction fluxes, indicating the significance of the surface energy loss.

Fakheri, Ahmad↗

A Dual Multilayer Insulation Blanket Concept to Radically Reduce Heat Loss From Thermally Controlled Spacecraft and Instruments

At large distances from the Sun (e.g. Jupiter/Saturn), the solar flux is less than 4% that at Earth. This requires very large solar arrays to meet the power demands of a typical new mission concept. Heat loss through Multi-Layer Insulation (MLI) blankets typically constitutes the vast majority of the total heat loss. Hence, improvements to MLI blankets that reduce heat loss are advantageous to the spacecraft design. The overall effective emittance (ε*) of MLI is usually a range dependent on the number of layers, size of blanket, seams, feedthroughs, layer density and operating temperatures of the heat source and heat sink. A concept has been developed at JPL to reduce the ε* by as much as a factor of two, which produces a corresponding reduction in heat losses. This concept utilizes two MLI blankets physically separated by traditional bumpers or spacers used for micrometeoroid protection. The outer surface of the inner blanket and the inner surface of the outer blanket are low emissivity surfaces to further minimize the total ε* of the overall dual MLI system. Analytical predictions of a dual MLI concept have been made using test data based ε* correlations. A development test has been conducted to validate the dual blanket design’s performance. This paper will describe the dual blanket design concept, schemes for its implementation, and the corresponding test results to validate its performance.

Duran, Mark↗

An Analytical Investigation of the Heat Losses from a U.S. Navy K-Type Airship

The heat losses from the envelope surface of a U.S. Navy K-type airship are evaluated to determine if the use of heat is a feasible means of preventing ice and snow accumulations on lighter-than-air craft during flight and when moored uncovered. Consideration is given to heat losses in clear air (no liquid water present in the atmosphere) and in probable conditions of icing and snow. The results of the analysis indicate that the amount of heat required in flight to raise the surface temperature of the entire envelope to the extent considered adequate for ice protection, based on experience with tests of heavier-than-air craft, is very large. Existing types of heating equipment which could be used to supply this quantity of heat would probably be too bulky and heavy to provide a practical flight installation. The heat requirements to provide protection for the nose and stern regions in assumed mild to moderate icing conditions appear to be within the range of the capacity of current types of heating equipment suitable for flight use. The amount of heat necessary to prevent snow accumulations on the upper surface of the airship envelope when moored uncovered under all conditions appear to be excessive for the heating equipment presently available for flight use, but could possibly be achieved with auxiliary ground heating equipment.

Hillendahl, Wesley H.↗

Extinction of the Stagnation Point Diffusion Flame: Effect of Conductive Heat Loss into Solid Interior

The flammability boundary of a solid is U-shaped with the ordinate as ambient oxygen percentage (or total pressure) and the abscissa represents flow velocity, gravity level, stretch rate, etc. The left side of the flammability boundary is the quenching branch, and the right side is the blow-off branch. Quenching is due to a weak flame whose heat release from combustion cannot overcome the excessive heat losses from, for example, radiation. Blow-off is due to a short gas residence time that is smaller than the chemical reaction time (traditionally referred to as the small Damköhler number effect). For thick solids, the heat conduction into the solid interior has a long transient after ignition before the solid temperature reaches the steady state. During this slow transient, there is excessive (i.e. more than that at the steady state) gas phase heat conduction into the solid interior. From the viewpoint of the quasi-static gaseous flame, this is an additional heat loss that will affect the gas flame's flammability. In this work, a previously developed one-dimensional axisymmetric stagnation-point diffusion flame model is extended to account for the excessive heat loss into the solid beyond the steady burning state. A non-dimensional excessive conductive heat loss parameter Ψ is defined in the paper to account for the transient solid effect. For each Ψ, the gas phase is considered reaching a quasi-steady state. Extensive numerical computations have been performed to determine the extinction boundary and the characteristics of near-limit flames. The U-shaped flammability boundary is now a series of boundaries with Ψ as a parameter. Flame structures under the same environment condition but with different Ψ are compared. For a given oxygen ambient, the extinction boundary Ψ vs stretch rate is an inverted U-shape. The boundary consists of a blowoff branch and a radiative quenching branch. Extensive computed data including flame and pyrolysis temperatures, burning rate, flame standoff distance, species concentration, and reaction rate are presented along the extinction boundaries. Heat balance analysis is performed for both the gas phase and the gas-solid interface. Along the extinction boundary, the relative importance of conduction, convection, radiation, and chemical reaction are analyzed in detail.

Stagnation point diffusion flame↗