Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Godiva Burst”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

34 records · Page 2

Godiva-IV Dosimetry Exercise 2022 Preliminary Results

Integral Experiment Request (IER) 538 is part of a series of dose characterization and nuclear accident dosimetry (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). This is the second NAD exercise using the Godiva-IV critical assembly and the third NAD exercise overall. The participating laboratories provided their own dosimeters that were mounted on the Lawrence Livermore National Laboratory (LLNL) BOttle Manikin ABsorption (BOMAB) phantoms and aluminum plates. The BOMABs and plates were placed at two, three, and four meters away from the center of Godiva. Alongside the NADs, there was a LLNL Passive Neutron Spectrometer (PNS), Atomic Weapons Establishment (AWE) PNS, and Y-12 Sphere present to measure the neutron dose from Godiva. Two irradiations were conducted to test the NAD performance from each laboratory and assesses their performance to the DOE-STD-1098-2017 part 515 criteria. Neutron and gamma doses were measured prior to this exercise. This work presents a model for the neutron and gamma dose respectively to serve as the reference value. A code written in C/C++/ROOT was used to fit the measured neutron and gamma dose with the new models. It was assumed that the neutron and gamma doses are proportional to the change in temperature of Godiva after a burst irradiation. Uncertainties for the reference values were calculated using error propagation of the model’s parameters. Preliminary results (within twenty-four hours) and final results were compared for each laboratory. On average of all the participating laboratories, 32% of neutron doses and 78% of gamma doses were outside the DOE standards. One laboratory did not report their dose readings and were not included in this average. There is a bias for a lower neutron dose and a higher gamma dose based on the distribution of results. In comparison with the past Godiva-IV NAD exercise, there is an improvement in neutron dose readings by 20%.

BOttle Manikin ABsorption (BOMAB)↗

Yield and PDV Measurements of the Godiva-IV Critical Assembly (Preliminary Report)

A high dynamic range, scinillator based detector, the MHD-240, was used to measure the gamma and neutron flux of several prompt critical bursts of the Godiva-IV assembly. The measurements provided the alpha and FWHM for several different burst temperatures. Calibrations of the MHD240 gamma and neutron sensitivity along with MCNP based simulation of the Godiva-IV assembly will allow us to also determine the total fission yield of the burst integrated over approximately 5 ms. Work is ongoing to check the calibrations of the MHD-240, and improve the MCNP simulations. This is a preliminary report, and the fission yields reported here are not final and are likely inaccurate. The measured alpha and FWHM are not impacted by the calibration issues and are considered final.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Gamma Converter Box Preliminary Design [Slides]

Objective: Develop a test capability near Godiva IV fast burst reactor to maximize gamma dose to neutron dose ratio and gain increase in gamma dose over free field. Goal: Maximize gamma dose to neutron dose ratio and gain increase in gamma dose over free field.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

National Criticality Experiments Research Center (NCERC) - capabilities and recent measurements

The National Criticality Experiments Research Center (NCERC) located at the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS) and operated by Los Alamos National Laboratory (LANL) is home to four critical assemblies which are used to support of range of missions, including nuclear criticality safety and nuclear nonproliferation. Additionally, subcritical systems can also be assembled at NCERC. NCERC is providing critical and subcritical experiments valuable to the nuclear data community and experiments performed at NCERC are often published as benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. This manuscript will give a broad overview of recent experiments performed at NCERC, upcoming experiments, and why integral measurements are important and useful to the nuclear data community. The four critical assemblies are GODIVA IV, FLATTOP, COMET, and PLANET. GODIVA IV is a cylindrical metal fast burst reactor, the fourth in the GODIVA series that dates back to the 1950’s. FLATTOP is an highly enriched uranium (HEU) or Pu core reflected by natural uranium. COMET and PLANET are vertical lift assemblies, where one half of the reactor can be lifted to the upper half of the reactor to create a critical system. Some recent experiments include various critical intermediate energy assemblies with lead, and subcritical measurements of plutonium reflected by copper, tungsten, and nickel. Work is also underway to make a better measurement of the critical mass of neptunium, using a neptunium sphere surrounded by nickel shells. Additionally, measurements will be performed next year with HEU shells from Rocky Flats. These HEU shells will be stacked together to make larger systems, allowing for a large range of criticality (from subcritical to delayed critical). Other upcoming measurements include an HEU critical assembly sensitive to intermediate energy neutrons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A New Era of Nuclear Criticality Experiments: The First 10 Years of Godiva IV Operations at NCERC

The work presented in this paper focuses on the first 10 years (2011–2020) of Godiva IV operations at the National Criticality Experiments Research Center (NCERC). Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5% molybdenum for strength. Godiva is one of the last such critical assemblies in the United States and can be used for studies of super-prompt-critical behavior as well as irradiations and demonstrations. An overview of the startup of Godiva IV at NCERC is given followed by a summary of the experiments performed utilizing Godiva IV over the first 10 years of operation at NCERC.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

237 Np Fission Spectrum Cumulative Fission Product Yield Measurement Using Godiva IV Critical Assembly

Precise integral measurement of fast neutron-induced fission product yields for various actinides is of high interest for applied nuclear science. The goal of this effort is to improve uncertainties in fission product yield values of 237 Np. Fission was induced in a NpO 2 (NO 3 ) target using the Godiva IV critical assembly in burst mode. The irradiated sample was transferred to a high-resolution γ-ray detection setup within 50 minutes. γ-ray list mode data was collected from 50 minutes to 1 week after the irradiation. γ-ray spectroscopy was performed to analyze the time dependent γ-ray yields using an automated peak search algorithm to identify isotopes by their decay γ-ray energy and half-life. Finally, the initial activity for each isotope identified was used to calculate their fission product yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

239 Pu Fission Spectrum Cumulative Fission Product Yield Measurement Using Godiva IV Critical Assembly

Precise integral measurement of fast neutron-induced fission product yields for various actinides is of high interest for applied nuclear science. The goal of this effort is to improve uncertainties in fission product yield values of 239 Pu. Fission was induced in a pure 239 Pu (>99%) target using the Godiva IV critical assembly in burst mode. Further, the irradiated sample was transferred to a high-resolution γ-ray detector within 45 minutes. γ-ray list mode data was collected from 45 minutes to 1 week after the irradiation. γ-ray spectroscopy was performed to analyze the time dependent γ-ray yields using an automated peak search algorithm to identify isotopes by their decay γ-ray energy and half-life. The initial activity for each isotope identified was used to calculate their fission product yield.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The First ICNC February 10-12, 1981 [Slides]

The first meeting that became the International Conference on Nuclear Criticality—ICNC—was held at the Los Alamos National Laboratory in February 1981. This presentation includes information on that meeting, including several experiments performed around that time period.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experiment Design and Preparation for a Shielding Benchmark Utilizing Godiva-IV

An experiment is currently being designed to provide a high-quality shielding benchmark for Criticality Accident Alarm System (CAAS) modeling. Previous benchmarks have suffered from uncertainty primarily due to two factors. The first factor is radiation that is not directly coming from the source, also known as room return. Room return is notoriously difficult to account for in experimental data and to model in benchmarks. The second factor is uncertainty associated with the source term itself. In order to reduce these two sources of uncertainty, this experiment will utilize a room return shield [1] that will reduce the effect of room return and previous work performed to ensure the reproducibility of the source term. The experiment will use the Godiva IV [2] assembly located at the National Criticality Experiments Research Center (NCERC) to provide a neutron source representative of a criticality accident. Previous experiments [3]-[4] have shown that Godiva IV is capable of producing both bursts and steady-state emissions of equal magnitude which will allow for reduced uncertainty in the source term. The room return shield will house and isolate the shielding samples, neutron activation foils, and other detectors. Data collected will provide a comparison of the neutron and gamma dose for shielded and unshielded configurations. This data will be used to validate shielding data used for modeling criticality accident alarm systems. Shielding samples included in this benchmark are C, Fe, NaCl, Pb, high density polyethylene, and SiO 2 . This paper details the design of the room return shield, the experimental plan, challenges, and mitigation strategies.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

IER 268 CED-3b Report

The goal of IER 268 was to collect information from the operation of the Godiva IV super-prompt critical assembly to support multi-physics modeling efforts. There were two types of systems deployed. One was a Photo-Doppler Velocimetry (PDV) system which used the reflection of laser light on the surface of the Godiva IV core. The other consisted of an MHD 240 detector with two other detectors (an MHD-241 and an Eljen EJ-325A) used for reference as the MHD-240 detector was moved. The collection is referred to as the MHD Detector in the narrative log. There were two types of Godiva operations performed to gather data. A series of super-prompt critical bursts were performed and data collected on both systems, tied to a common trigger. Separately, a series of delayed critical operations at various power levels was performed for a combination of MHD detector distances from Godiva and the presence and absence of a shield in the line of sight between Godiva and the MHD detector. This data was collected to determine the contribution of room return during the burst measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation characterization summary for the WSMR fast burst reactor environment at the 6-inch location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields for the White Sands Missile Range (WSMR) Fast Burst Reactor, also known as molybdenum-alloy Godiva (Molly-G) has been assessed at the 6-inch irradiation location. The neutron energy spectra, uncertainties, and common radiation metrics are presented. Code-dependent recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. The Molly-G core was designed and configured similarly to Godiva II, as an unreflected, unmoderated, cylindrical annulus of uranium-molybdenum-alloy fuel with molybdenum loading of 10%. At the 6-inch position, the axial fluence maximum is about 2.4×10 13 n/cm 2 per MJ of reactor energy; about 0.1% of the neutron fluence is below 1 keV and 96% is above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is estimated at 2.2×10 13 n/cm 2 per MJ of reactor energy. The prompt gamma-ray dose is roughly 2.5E+03 rad(Si) per MJ and the delayed gamma-ray dose is about 1.3E+03 rad(Si) per MJ.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Radiation Characterization Summary: WSMR Fast Burst Reactor Environment at the 6-Inch and 24-Inch Irradiation Locations

This document presents the facility-recommended characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields for the White Sands Missile Range (WSMR) Fast Burst Reactor, also known as molybdenum-alloy Godiva (Molly-G), at the 6-inch and the 24-inch irradiation locations. The neutron, prompt gamma-ray, and delayed gamma-ray energy spectra, uncertainties, and covariance matrices are presented. Code dependent recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER 557: Godiva IV Reproducibility/Characterization [Slides]

The primary goal of the IER 557 Godiva IV reproducibility/characterization process is to determine reproducibility for 70°C bursts. The secondary goal is to characterize the radiation field, including absolute calibration with radchem counting of fission foils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva IV Thermal Neutron Dosimetry Modeling and Variance Reduction

The transfer of the Godiva IV experiment from the Los Alamos Critical Experiments Facility (LACEF) to the National Critical Experiments Research Center (NCERC) introduced a vastly different experiment room return to the neutron flux. The contribution of the background to the burst neutron energy spectrum is significant in the thermal and epithermal neutron energies. Target materials may be placed in various locations in the Godiva room, or outside of the room, for thermal neutron activation. Modeling of this dosimetry problem in Monte Carlo N-Particle (MCNP) presented a novel challenge compared to previous Godiva IV glory hole irradiation simulations. An advanced dosimetry modeling framework for high efficiency calculations in locations far from the Godiva IV fission source was desired. The mesh-based weight windows and point detector advanced variance reduction techniques in MCNP were implemented and tested using adaptations of the critical experiment benchmark model of the Godiva IV problem. The models were validated against measured activations of Nickel, Indium, Scandium, and Cobalt foils at locations 2 meters from the Godiva IV core. Dosimetry measurements were performed in collaboration with Sandia National Laboratory. The weight windows and point detector variance reduction coupled method resulted in the highest problem efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Godiva IV Shielding Benchmark Overview [Slides]

This presentation shows that Integral experiments increase the level of realism from that of data measurements. Further, Godiva IV is capable of intensities to activate foils. IER 498 uses a relative measurement to provide an intermediate level of realism. With reproducibility and room return management are key components. The test matrix put forward in CED-2 enables numerous cross-comparisons. IER 498 facilitates various additional works using a room return shield to isolate the source. IER 557 demonstrated burst reproducibility sufficient for IER 498.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗