Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Godiva Burst”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Godiva IV Burst Reproducibility and Diagnostic Testing

Godiva IV is a fast burst critical assembly located at the Nation Criticality Experiment Research Center (NCERC) in the Nevada National Security Site (NNSS). It is constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5% molybdenum for strength. The assembly can be operated at delayed critical or can be used to perform super-prompt critical bursts with temperature rises of up to 250 °C. Several projects with the objective of characterizing Go diva IV are ongoing including characterizations of its radiation emission and thermomechanics. One of the characterization projects is a study of the variability in the relative source emission (or fluence in absolute terms) between bursts that are nominally the same size. There is some inherent variation in the number of fissions, or "size" of the burst, even for bursts where the operators perform identical processes. The source of the variation can be attributed to several factors. The largest contributor is the precision with which the operators are able to determine delayed critical (DC). Operators find DC for every burst operation. The impact of being slightly above or below DC can change the super-prompt critical reactivity and therefore the source term. The temperature of the fuel is another factor. Establishing delayed critical prior to performing a burst act as a control of the bulk temperature coefficient of reactivity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Plan for IER-443 Testing of the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor

This document provides the scope and details of the “Plan for Testing the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor”. Due to the relative simplicity of the testing goals, scope, and methodology, the NCSP Manager approved execution of the test when ready. No preliminary CED-1 or final design CED-2 reports were required or issued. The test will subject Criticality Accident Alarm System (CAAS) detectors supplied by Y- 12 and AWE to very intense and short duration mixed neutron and gamma radiation fields. The goals of the test will be to (1) substantiate functionality, for both existing and newly acquired Y- 12 CAAS detectors, and (2) the ability of the AWE detectors to provide quality temporal dose information after a hypothetical criticality accident. ANSI/ANS-8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates which will be achieved in this test will exceed these requirements. Pulsed radiation fields will be produced by the Godiva IV fast metal burst reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The magnitude of the pulses and the relative distances to the detectors will be varied to afford a wide range of radiation fluence and pulse widths. The magnitude of the neutron and gamma fields will be determined by reactor temperature rise to fluence and dose conversions which have been previously established through extensive measurements performed under IER-147. The requirements for CAAS systems to detect and alarm under a “minimum accident of concern” as well as other functional requirements specified in ANSI/ANS-8.3.1997, are not included in the test. Routine and periodic maintenance and calibrations performed at Y-12 and AWE are intended to provide adequate confirmation for meeting these requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report for the Testing of the Y-12 Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor (IER-443)

This report documents the experimental conditions and final results for the performance testing of the Y-12 Criticality Accident Alarm System (CAAS) detectors at the Godiva IV Burst Reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The testing followed a previously issued test plan and was conducted during the week of July 17, 2017, with completion on Thursday July 20. The test subjected CAAS detectors supplied by Y-12 to very intense and short duration mixed neutron and gamma radiation fields to establish compliance to maximum radiation and minimum pulse width requirements. ANSI/ANS- 8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates provided by each burst during the test exceeded those requirements. The CAAS detectors all provided an immediate alarm signal and remained operable after the bursts establishing compliance to the requirements and fitness for re-deployment at Y-12.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantifying Burst Repeatability for Godiva IV

The minimum resolvable relative change in the neutron source emission of Godiva IV between bursts, i.e., burst repeatability, was quantified using a combination of activation monitors and a resistance temperature detector (RTD). Measurements support changes in the neutron source emission between bursts can be determined with a precision of 2.7%. The measurements were performed during a series of twelve Godiva IV bursts and were a collaborative effort between Los Alamos National Laboratory, Sandia National Laboratories, and Pacific Northwest National Laboratory. Gold, iron, nickel, and sulfur activation monitors were positioned in a sample holder in the central cavity of Godiva IV for each burst. The RTD is part of the Godiva burst diagnostic system and is in a fixed location in the safety block of Godiva IV. It is used to determine the temperature rise of the burst, i.e., the difference between the maximum temperature recorded during the burst and the initial temperature prior to the burst. Differences in either the specific activity of the activation monitor reactions, or the temperature rise can be used to determine the relative change in the neutron source emission for separate bursts, but historic results have proven that each method is susceptible to various sources of biases which generally cannot be isolated using a single method. We address this issue by applying both measurement methods and analyzing the correlation between them. The results presented in this work will be used to support future experiments with Godiva IV at the National Criticality Experiments Research Center (NCERC).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uranium–Molybdenum Alloy Critical Experiments for the Design of the Health Physics Research Reactor

Clean critical experiments with a uranium-molybdenum alloy (average of 10.1616 wt. % Mo with a density of 17.08 g/cm 3 ) were performed at the Oak Ridge Critical Experiments Facility in 1961 to support the design of the Health Physics Research Reactor (HPRR). The HPRR was similar to the Godiva burst reactor at Los Alamos National Laboratory and was designed to produce 50 microseconds burst of 10 17 fission pulses of radiation for dosimetry measurements, initially in support of the determination of the doses from the nuclear detonations in Japan during World War II. These experiments reported here were used to verify the calculational methods used to design the HPRR. These delayed critical measurements were:1) a solid unreflected and unmoderated 8-in.-dimeter U-Mo cylinder, 2) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void, 3) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void filled with stainless steel, 4) Same as 3) but with 3-in-thick Plexiglas reflector on top with and without cadmium between the reflector and the U-Mo alloy assembly with steel in the center, and 5) an unmoderated and unreflected annulus which was a modification of the second but with the lower 5 inches of the central hole enlarged to 3.5 in. with various reflector conditions. The reflector conditions were: 1-in.-thick Plexiglas on all outer surfaces-void in the center; 1-in.-thick Plexiglas on all outer surfaces-Plexiglas in the center; 2-in.- thick Plexiglas on radial surface-void in the center; 6-in.-thick Plexiglas on the bottom only-Plexiglas in the center; and 6-in.-thick Plexiglas on bottom, 1-in.-thick on top and on the lower 8.25-cm.-section of the radial surface-void in the center. For some of these reflector conditions 0.025-cm.thick cadmium was located between the reflector and the U-Mo alloy. The uranium contained 93.17 wt. % 235 U. Reflection was a safety concern for this unmoderated and unreflected reactor and reduction of reflection effects was also investigated by insertion of neutron absorber around the U-Mo alloy. The stainless steel 304 contained 18% nickel and 8% chromium and the rest iron. The reflector material was a methacrylate plastic (Plexiglas) containing 5.8 x 10 22 atoms/cm 3 of hydrogen and 3.6 x 10 22 atoms/cm 3 of carbon with a density of 1.20 g/cm 3 . The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a EURATON Nuclear Energy Agency (NEA) benchmark. The data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in k eff could be as low as ±0.0002 for some configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Dosimetry characterization of the Godiva Reactor under burst conditions

A series of sixteen (16) burst irradiations were performed in May 2014, fifteen of which were part of an international collaboration to characterize the Godiva IV fast burst reactor at the National Criticality Experiments Research Center (NCERC). Godiva IV is a bare cylindrical assembly of approximately 65 kg of highly enriched uranium fuel (93.2% 235 U metal alloyed with 1.5% molybdenum for strength) and is designed to perform controlled prompt critical excursions (Myers 2010, Goda 2013). Twelve of the irradiations were dedicated to neutron spectral measurements using a Bonner multiple sphere spectrometer. Three irradiations, with core temperature increases of 71.1°C, 136.9°C, and 229.9°C, were performed for generating comparative fluence data, establishing corrections for varying heights, testing linearity with burst temperature, and establishing gamma dose characteristics.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Photo Doppler Velocimetry and Gamma/Neutron Yield Measurements of Godiva-IV Critical Assembly

The purpose of this experiment was to collect data for a dynamic benchmark of the Godiva-IV burst assembly. Data were taken using two different measurement systems. The gamma & neutron flux was measured using a calibrated, high-dynamic-range scintillator detector, the MHD-240. The measurement will be used to determine the total fission yield and alpha throughout the burst and shutdown sequence of Godiva-IV. The Photon Doppler Velocimetry (PDV) measurement detected the surface motion of the burst assembly as a function of time. The combined data will be used in a multi-physics simulation of the Godiva-IV burst assembly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva Experiments for the Nuclear Criticality Safety Program (NCSP)

Godiva IV is a fast burst critical assembly constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5 percent molybdenum for strength. Godiva is one of the last such critical assemblies in the United States, and can be used for studies of super-prompt critical behavior as well as irradiations and demonstrations. A demonstration of a Godiva burst is usually performed as a highlight of the hands-on portion of the Criticality Safety Training Classes taught at the National Criticality Experiment Research Center (NCERC). The Godiva burst is used to demonstrate the concept of super-prompt critical and the time-scale of a criticality accident. In addition, several NCSP projects have been conducted on Godiva IV over the past two years. One experiment focused on collecting data to support multiphysics simulations using Photo-Doppler Velocimetry (PDV) to measure surface movement and gamma detectors to measure the burst output as the burst develops from background to peak over ten orders of magnitude. Another experiment was performed to demonstrate the functionality of the Criticality Accident Alarm System (CAAS) system developed for installation in the Y-12 Uranium Processing Facility (UPF). The system must not only respond to a criticality event and alarm, but must also be shown to operate in a high dose environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

Au-198 and TLD-600 results from IER-593 Godiva irradiations

This report summarizes the results from dosimetry packets deployed during a nominally 250 ◦C temperature rise Godiva IV burst. Dosimetry packets including Bare Au foils, Cd covered Au foils, and Thermoluminescent Dosimeters (TLDs) were deployed at five positions around Godiva at a height corresponding to the center height of the HEU fuel.

61 RADIATION PROTECTION AND DOSIMETRY↗

Quick Look Report of Godiva U233 shot March 2022 Data Collection Activities

This report discussing the March 2022 irradiation of U233 on the Godiva critical assembly using burst mode and subsequent analysis of the fission products starting at 65 minutes post irradiation, and ending 12 days later. The Short-Lived Fission Product Yield (SLFPY) project is one of many efforts under the Nuclear Physics Multi-Lab and related Venture Project. The objective of the SLFPY project is to provide improved measurements of fission product yields for select nuclides. The SLFPY project consists of measurement and analysis campaigns. To produce fission data, samples of actinide material are irradiated in a high-flux neutron environment. These samples are quickly placed in front of a detection system where both gamma singles and coincidence spectra are collected as a function of time. Gamma spectroscopy is performed on the irradiated material on site near the irradiation facility, starting as soon as feasible after the irradiation and continuing for 7 days or longer. Following the data collection, time-dependent fission yield analyses are performed using gamma-ray spectroscopy. This document summarizes the measurement campaign performed March 21 - April 4, 2022 where sub-gram quantities of 233 U nitrate (UO 2 (NO 3 ) 2 ) were irradiated in the Godiva reactor. The Godiva burst #2076 conducted under experiment IER 504 had a temperature change of +156 degrees Celsius, lasted 13.32 microseconds, and had a reactivity of $\$$1.089. The targets consisted of uranium oxide solution deposited in a quartz tube and packed with quartz wool. The flame-sealed quartz ampoules were used to contain the uranium samples for the irradiation and count activities. On March 22, 2022, at 10:27:00 a.m. the three uranium ampoules, along with a witness foil pack, were irradiated in the Godiva critical assembly using burst mode operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Godiva IV Central Cavity Neutron Environment Characterization with Threshold Neutron Detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235 U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

UPF and Y-12 Criticality Accident Alarm System (CAAS) Radiation Testing Report

This report documents the experimental conditions and results for the testing of the Mirion Technologies CAAS-3S Criticality Accident Alarm System (CAAS) for the Y-12 National Security Complex (Y-12) and Uranium Processing Facility (UPF). The testing was conducted at the Godiva IV Burst Reactor at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS) during the week of January 11, 2021. The testing was conducted in accordance with 25774-QL-POA-JR00-00002-VDE-27.0, CAAS-3S Radiation Testing of Cabinet Components Test Plan. The tests subjected the CAAS-3S system to intense and short duration mixed neutron and gamma radiation fields and to high integrated radiation doses. The purpose of the test was to environmentally qualify various CAAS-3S components in a radiation environment. Successful completion of the tests was predicated on the collaborative efforts of several organizations. Sandia National Laboratory (SNL) and Lawrence Livermore National Laboratory (LLNL) provided dosimetry to estimate photon and neutron dose. Los Alamos National Laboratory (LANL) manages the NCERC facility, operated the Godiva IV reactor, and provided field support for CAAS-3S placement and communications interface for data acquisition systems supplied by Mirion Technologies. Throughout the test campaign, Y-12 and UPF personnel provided technical support in determining changes to the test schedule, as needed, interpretation of the results, and comparison between the measured dosimetry data and predicted results. Throughout the test campaign, Mirion personnel provided technical support in the operation of the CAAS-3S system itself.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hands-On Experimental Training [Slides]

Training provided includes: Nuclear Criticality Safety Fundamentals, Sub-Critical "Hands On" Demonstration, Hand-Stacking and Remote Approach to Critical Using the Planet Assembly, Flattop Free-Run Demonstration, and Godiva-IV Critical Assembly Demonstration.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

CAAS-3S Radiation Testing for Y-12 and UPF with Godiva-IV

The Y-12 National Security Complex and the Uranium Processing Facility (UPF) selected the Mirion CAAS-3S as the Criticality Accident Alarm System for UPF and for Y-12 facilities replacing their legacy CAAS as part of efforts to extend the facility lifespans. As part of this process, the CAAS-3S system was exposed to a high radiation dose and dose rate during reactor testing with the Godiva-IV fast burst reactor. The reactor testing was designed around preliminary analyses that determined Y-12 and UPF requirements, and simulations of the radiation field within the reactor facility were used to determine reactor operating parameters, CAAS equipment locations, and the design of a neutron shield wall. This paper presents the design and results of the testing, and discusses how the test results were interpreted by criticality safety engineers at Y-12 and UPF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A neutron fluence map of the Los Alamos National Laboratory Godiva IV critical assembly

A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva IER268 PDV Measurements

PowerPoint slides providing a quick-look of photon Doppler velocimetry (PDV) data taken during a series bursts using the Godiva machine located at the NNSS Device Assembly Facility. Vibrations, or ringing, of approximately 7.2 to 7.8 kHz were observed.

47 OTHER INSTRUMENTATION↗