Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GODIVA REACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Godiva IV and Juliet Diagnostics CED-1, Rev. 1 (IER-176)

The Juliet experiment is currently in preliminary design (IER-128). This experiment will utilize a suite of diagnostics to measure the physical state of the device (temperature, surface motion, stress, etc.) and the total and time rate of change of neutron and gamma fluxes. A variety of potential diagnostics has been proposed in this CED-1 report. Based on schedule and funding, a subset of diagnostics will be selected for testing using the Godiva IV pulsed reactor as a source of neutrons and gammas. The diagnostics development and testing will occur over a two year period (FY12-13) culminating in a final set of diagnostics to be fielded for he Juliet experiment currently proposed for execution in FY15.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

National Criticality Experiments Research Center (NCERC) - capabilities and recent measurements

The National Criticality Experiments Research Center (NCERC) located at the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS) and operated by Los Alamos National Laboratory (LANL) is home to four critical assemblies which are used to support of range of missions, including nuclear criticality safety and nuclear nonproliferation. Additionally, subcritical systems can also be assembled at NCERC. NCERC is providing critical and subcritical experiments valuable to the nuclear data community and experiments performed at NCERC are often published as benchmarks in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook. This manuscript will give a broad overview of recent experiments performed at NCERC, upcoming experiments, and why integral measurements are important and useful to the nuclear data community. The four critical assemblies are GODIVA IV, FLATTOP, COMET, and PLANET. GODIVA IV is a cylindrical metal fast burst reactor, the fourth in the GODIVA series that dates back to the 1950’s. FLATTOP is an highly enriched uranium (HEU) or Pu core reflected by natural uranium. COMET and PLANET are vertical lift assemblies, where one half of the reactor can be lifted to the upper half of the reactor to create a critical system. Some recent experiments include various critical intermediate energy assemblies with lead, and subcritical measurements of plutonium reflected by copper, tungsten, and nickel. Work is also underway to make a better measurement of the critical mass of neptunium, using a neptunium sphere surrounded by nickel shells. Additionally, measurements will be performed next year with HEU shells from Rocky Flats. These HEU shells will be stacked together to make larger systems, allowing for a large range of criticality (from subcritical to delayed critical). Other upcoming measurements include an HEU critical assembly sensitive to intermediate energy neutrons.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

A Review of Nuclear Reactor Transients

This paper explores the nuclear yield that is produced during nuclear transients in small reactors. Nuclear reactor transients can have a wide range of effects such as the reproducible power excursions as found in Godiva-IV to full reactor destruction as planned for in the Kiwi-TNT test. Criticality accidents are also included in this study as in essence a small nuclear reactor has been inadvertently created. The motivation for this paper is to educate the audience as to the likely fission energy release for a typical transient in a small nuclear reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Time Scale Effects on the Temperature Coefficient of Reactivity

For a nuclear reactor, the temperature coefficient of reactivity (TCR) is of significance for both power control and safety analysis, but it is not always a constant. For example, the TCR may be dependent upon temperature due to Doppler broadening, and may be also dependent upon time scale due to heat transfer and thermal expansion. A fast burst reactor is a favorable nuclear facility to simulate the time scale effects on the TCR. Fast burst reactors are generally unmoderated research reactors of enriched uranium metal or uranium alloys. The neutrons are fast and the Doppler broadening effects can be neglected, and the TCR is mainly contributed by fuel thermal expansion. Fast burst reactors can operate on both steady state power mode and burst power mode. In steady state power mode, the systems are assumed to be in thermal equilibrium. In burst mode, the full width at half maximum (FWHM) of the power is from tens of microseconds to a few milliseconds, and the heat transfer is generally neglected. If FWHM is short enough, thermal expansion will have a time delay due to inertial effect. This paper is aimed to study the exact time scale effects on the TCR due to thermal expansion. The TCR contributed by the Doppler broadening effects was neglected, because it is relatively small (The k{sub eff} as a function of temperature was also calculated using the Monte Carlo particle transport code JMCT by our group, and no definite difference due to the temperature change was obtained near room temperature), and there is no method to evaluate the time scale dependence of the Doppler broadening effects yet. In the time scale from 1 x 10{sup -6} s to 1 x 10{sup 5} s, the TCR of a Godiva-like spherical fast burst reactor was calculated with perturbation theory. A Godiva-like spherical fast burst reactor was studied, the calculation of the time scale effects on TCR involved thermal conduction, thermoelasticity and reactivity variation analysis. Both the thermal and the thermoelastic problems were solved using ANSYS software. ANSYS is software implementation of finite element simulations, which is widely used in engineering field. The reactivity variation due to thermal expansion was calculated with perturbation theory.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CAAS-3S Radiation Testing for Y-12 and UPF with Godiva-IV

The Y-12 National Security Complex and the Uranium Processing Facility (UPF) selected the Mirion CAAS-3S as the Criticality Accident Alarm System for UPF and for Y-12 facilities replacing their legacy CAAS as part of efforts to extend the facility lifespans. As part of this process, the CAAS-3S system was exposed to a high radiation dose and dose rate during reactor testing with the Godiva-IV fast burst reactor. The reactor testing was designed around preliminary analyses that determined Y-12 and UPF requirements, and simulations of the radiation field within the reactor facility were used to determine reactor operating parameters, CAAS equipment locations, and the design of a neutron shield wall. This paper presents the design and results of the testing, and discusses how the test results were interpreted by criticality safety engineers at Y-12 and UPF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2014 CALIBAN and PROSPERO experiments for the criticality accident dosimetry intercomparison - 14529

Nuclear criticality accident dosimetry is very specific, due to the mixed fields and to energy and dose ranges which could be out of the range of classical individual dosimetry. The maximal neutron and gamma dose must be determined as well as other information such as the orientation of the victim in the radiation field. It is exceptionally challenging to establish doses in the event of partial body exposures. Therefore, frequent exercises are organized to maintain competencies and to train staff to perform such dosimetry. Experiments using the CALIBAN and PROSPERO reactors were performed in June and September 2014 in order to test various criticality accident dosimeters (CAD). These two metallic reactors are located at the CEA research center at Valduc (Cote-d'Or, France). They are composed of a metallic alloy of uranium with a high enrichment in the isotope {sup 235}U. These reactors are used for the production of mixed radiation fields primarily comprised of fission neutrons and gammas. CADs from three different laboratories (AWE, UK; IRSN, FR; LLNL, USA) were irradiated on water phantoms with three different orientations (0 deg. and 45 deg., front and rear faces) and free in air at both CALIBAN and PROSPERO reactors, in pulse and steady state modes. This paper will present the comparison of some results. These experiments will be useful preparation for other exercises planned in 2016 at the GODIVA-IV and FLATTOP reactors located at the Nevada National Security Site, USA. (authors)

42 ENGINEERING↗

A Mercury Model of the Molly-G Fast Burst Reactor (FBR)

In order to design neutron irradiation experiments at a given nuclear reactor, one requires a representative neutron spectrum for the configuration of the reactor that will exist during the experiment. This usually implies modeling the operation of the reactor using a neutron transport code. Since the modeling of pulsed neutron reactors is quite complex, requiring coupled modeling of neutronics and thermo-structural response, the typical methodology employs analysis of the neutron spectrum which is obtained from a static keff calculation. While this time-independent Eigenfunction is not truly representative of that during a reactor pulse, we postulate that it is a reasonable representation for our purposes. The Nuclear Survivability (NS) Program at LLNL is considering fielding such experiments at the Molly-G (‘Molybdenum Godiva-II’) Fast Burst Reactor (FBR) at the White Sands Missile Range (WSMR). The goal of these experiments is to (a) test / proof / calibrate diagnostics, and (b) test the efficacy of neutron shield configurations, before fielding at other nuclear reactors, such as the Annular Core Research Reactor (ACRR) at SNL/NM. After attempting to secure either drawings or a copy of an existing MCNP model of the Molly-G FBR from various institutions, it was decided to develop a new model for use with the Mercury Monte Carlo transport code. The model described herein will be used to design these experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

R-X Modeling Figures

This document contains figures that will be included in an ORNL final report that details computational efforts to model an irradiation experiment performed on the Godiva IV critical assembly. This experiment was a collaboration between LANL and ORNL.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Feasibility study of noise analysis methods on virtual thermal reactor subcriticality monitoring

This paper presents the analysis results of Rossi-alpha, cross-correlation, Feynman-alpha, and Feynman difference methods applied to the subcriticality monitoring of nuclear reactors. A thermal spectrum Godiva model has been designed for the analysis of the four methods. This Godiva geometry consists of a spherical core containing the isotopes of H-l, U-235 and U-238, and the H{sub 2}O reflector outside the core. A Monte Carlo code, McCARD, is used in real time mode to generate virtual detector signals to analyze the feasibility of the four methods. The analysis results indicate that the four methods can be used with high accuracy for the continuous monitoring of subcriticality. In addition to that, in order to analyze the impact of the random noise contamination on the accuracy of the noise analysis, the McCARD-generated signals are contaminated with arbitrary noise. It is noticed that, even when the detector signals are contaminated, the four methods can predict the subcriticality with reasonable accuracy. Nonetheless, in order to reduce the adverse impact of the random noise, eight detector signals, rather than a single signal, are generated from the core, one signal from each equally divided eighth part of the core. The preliminary analysis with multiple virtual detector signals indicates that the approach of using many detectors is promising to improve the accuracy of criticality prediction and further study will be performed in this regard. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The First ICNC February 10-12, 1981 [Slides]

The first meeting that became the International Conference on Nuclear Criticality—ICNC—was held at the Los Alamos National Laboratory in February 1981. This presentation includes information on that meeting, including several experiments performed around that time period.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gamma Converter Box Preliminary Design [Slides]

Objective: Develop a test capability near Godiva IV fast burst reactor to maximize gamma dose to neutron dose ratio and gain increase in gamma dose over free field. Goal: Maximize gamma dose to neutron dose ratio and gain increase in gamma dose over free field.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.↗

A neutron fluence map of the Los Alamos National Laboratory Godiva IV critical assembly

A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva IV Central Cavity Neutron Environment Characterization with Threshold Neutron Detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235 U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Radiation characterization summary for the WSMR fast burst reactor environment at the 6-inch location

The characterization of the neutron, prompt gamma-ray, and delayed gamma-ray radiation fields for the White Sands Missile Range (WSMR) Fast Burst Reactor, also known as molybdenum-alloy Godiva (Molly-G) has been assessed at the 6-inch irradiation location. The neutron energy spectra, uncertainties, and common radiation metrics are presented. Code-dependent recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. The Molly-G core was designed and configured similarly to Godiva II, as an unreflected, unmoderated, cylindrical annulus of uranium-molybdenum-alloy fuel with molybdenum loading of 10%. At the 6-inch position, the axial fluence maximum is about 2.4×10 13 n/cm 2 per MJ of reactor energy; about 0.1% of the neutron fluence is below 1 keV and 96% is above 100 keV. The 1-MeV Damage-Equivalent Silicon (DES) fluence is estimated at 2.2×10 13 n/cm 2 per MJ of reactor energy. The prompt gamma-ray dose is roughly 2.5E+03 rad(Si) per MJ and the delayed gamma-ray dose is about 1.3E+03 rad(Si) per MJ.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Godiva-IV Delayed-Critical and Static Super-Prompt-Critical Conditions

Super-prompt-critical burst experiments were conducted on the Godiva-IV assembly at Los Alamos National Laboratory from the 1960s through 2005. Detailed and simplified benchmark models have been constructed for four delayed-critical experiments and for the static phase of a super-prompt-critical burst experiment. In addition, a two-dimensional cylindrical model has been developed for the super-prompt-critical condition. Criticality calculations have been performed for all of those models with four modern nuclear data libraries: ENDFIB-VI, ENDF/8-VII.0, JEFF-3.1, and JENDL-3.3. Overall, JENDL-3.3 produces the best agreement with the reference values for k eff .

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Reactivity Worth Measurement of Control Rods of CFBR-II with Inverse Kinetics Method

CFBR-II is a Godiva type metal HEU fast burst reactor. Reactivity adjustment of the reactor depends on three metal HEU rods (CPI, CP2 and CP3), which have positive reactivity worth. Reactivity effectiveness curves of the three rods are important to safe operation and control of CFBR-I. To measure the reactivity, two different techniques were used: the asymptotic period method (APM) and the inverse kinetic method(IKM). The APM is the most common used method on fast burst reactor, which measured the asymptotic power period then determined reactivity with the in-hour equation. This method only works for positive periods (super criticality state). The IKM can measured continuously reactivity changes by analyzing the variation of reactor power level with the inverse kinetic equation, which works for both subcritical and super critical state. We will mainly discuss how to measure reactivity effectiveness curves of control rods by the IKM.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calculating Control Rod Differential Worth Using Adjoint-Weighted Method

Recently, there are more and more research on using Monte Carlo method to calculate reactor important parameters. Control rod worth is one of the important parameters as it can determine the critical control rod position. There are two presentations of the control rod worth for utilization purpose, integral and differential. The former is the total reactivity change, while the latter is the reactivity change caused by per unit movement. In Monte Carlo calculation, differential control rod worth of a particular position is estimated by finite difference of reactivity between a small gap divided by gap distance. Though easy to implemented, the problem of this approach lies in that too large gap will enlarge error between 'differential' and 'difference', while too small gap will be disturbed by error caused by random fluctuation. Monte Carlo perturbation theory has been used to calculate the k{sub eff} sensitivity to certain parameters for a long time. By calculating the differential coefficient along with the k{sub eff}, this method is quite time-consuming and relatively accurate compared to finite difference method. Nevertheless, most of perturbation research focus on the perturbation of nuclide density or nuclear data. For geometrical perturbation, limited research was done before. Takahashi estimated the k{sub eff} sensitivity to reflector movement of pulsed fast reactor. MCNP6 used adjoint-weighted method for Godiva, Zeus and uranium oxyfluoride solution container benchmarks. This paper tries to apply the perturbation method to the determination of control rod differential worth. In this paper, based on RMC, a continuous-energy Reactor Monte Carlo transport code, Iterated Fission Probability method (IFP) is researched to calculate control rod differential worth on assembly level. IFP was originally developed by Hurwitz, and has been adopted by most of Monte Carlo code to compute adjoint-weighted parameters. This paper is organized with four parts. The first is introduction. Adjoint-weighted method is introduced in the second part. Problem 4 of benchmark from CASL is built to verify the method. Conclusion is given in final part.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗