Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GODIVA REACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dosimetry characterization of the Godiva Reactor under burst conditions

A series of sixteen (16) burst irradiations were performed in May 2014, fifteen of which were part of an international collaboration to characterize the Godiva IV fast burst reactor at the National Criticality Experiments Research Center (NCERC). Godiva IV is a bare cylindrical assembly of approximately 65 kg of highly enriched uranium fuel (93.2% 235 U metal alloyed with 1.5% molybdenum for strength) and is designed to perform controlled prompt critical excursions (Myers 2010, Goda 2013). Twelve of the irradiations were dedicated to neutron spectral measurements using a Bonner multiple sphere spectrometer. Three irradiations, with core temperature increases of 71.1°C, 136.9°C, and 229.9°C, were performed for generating comparative fluence data, establishing corrections for varying heights, testing linearity with burst temperature, and establishing gamma dose characteristics.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quick Look Report of Godiva U233 shot March 2022 Data Collection Activities

This report discussing the March 2022 irradiation of U233 on the Godiva critical assembly using burst mode and subsequent analysis of the fission products starting at 65 minutes post irradiation, and ending 12 days later. The Short-Lived Fission Product Yield (SLFPY) project is one of many efforts under the Nuclear Physics Multi-Lab and related Venture Project. The objective of the SLFPY project is to provide improved measurements of fission product yields for select nuclides. The SLFPY project consists of measurement and analysis campaigns. To produce fission data, samples of actinide material are irradiated in a high-flux neutron environment. These samples are quickly placed in front of a detection system where both gamma singles and coincidence spectra are collected as a function of time. Gamma spectroscopy is performed on the irradiated material on site near the irradiation facility, starting as soon as feasible after the irradiation and continuing for 7 days or longer. Following the data collection, time-dependent fission yield analyses are performed using gamma-ray spectroscopy. This document summarizes the measurement campaign performed March 21 - April 4, 2022 where sub-gram quantities of 233 U nitrate (UO 2 (NO 3 ) 2 ) were irradiated in the Godiva reactor. The Godiva burst #2076 conducted under experiment IER 504 had a temperature change of +156 degrees Celsius, lasted 13.32 microseconds, and had a reactivity of $\$$1.089. The targets consisted of uranium oxide solution deposited in a quartz tube and packed with quartz wool. The flame-sealed quartz ampoules were used to contain the uranium samples for the irradiation and count activities. On March 22, 2022, at 10:27:00 a.m. the three uranium ampoules, along with a witness foil pack, were irradiated in the Godiva critical assembly using burst mode operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

International Intercomparison Exercise for Nuclear Accident Dosimetry at the DAF Using GODIVA-IV

The Nuclear Criticality Safety Program operated under the direction of Dr. Jerry McKamy completed the first NNSA Nuclear Accident Dosimetry exercise on May 27, 2016. Participants in the exercise were from Lawrence Livermore National Laboratory (LLNL), Los Alamos National Laboratory (LANL), Sandia National Laboratory (SNL), Savanah River Site (SRS), Pacific Northwest National Laboratory (PNNL), US Navy, the Atomic Weapons Establishment (United Kingdom) under the auspices of JOWOG 30, and the Institute for Radiological Protection and Nuclear Safety (France) by special invitation and NCSP memorandum of understanding. This exercise was the culmination of a series of Integral Experiment Requests (IER) that included the establishment of the Nuclear Criticality Experimental Research Center, (NCERC) the startup of the Godiva Reactor (IER-194), the establishment of a the Nuclear Accident Dosimetry Laboratory (NAD LAB) in Mercury, NV, and the determination of reference dosimetry values for the mixed neutron and photon radiation field of Godiva within NCERC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Blind Intercomparison of Nuclear Accident Dosimetry using the Flattop Reactor at NCERC

The purpose of this exercise was to continue United States, United Kingdom, and France collaborative activities performing Nuclear Accident Dosimetry intercomparison. IER 148 was the inaugural intercomparison exercise using the Godiva reactor at the DAF. In contrast to IER 148, in the current exercise participants were “blind” to the known doses during the exercise, to simulate the dosimetry response to a real criticality incident. This document is the Final Exercise (CED-x) Report for IER-253, “International Intercomparison Exercise for Nuclear Accident Dosimetry at the DAF Using Flattop.” The report describes the structure and results of the exercise consisting of two irradiations. The details of all dosimetry elements and their placement in proximity to Flattop on support stands or phantoms was unknown to participating laboratories. The participating laboratories in this report are deidentified and the report summarizes participant results from the intercomparison. The exercise occurred during the week of May 21, 2018.

42 ENGINEERING↗

Experiment Logistics for an International Blind Intercomparison Exercise for Nuclear Accident Dosimetry at Godiva-IV

This document is the Experimental Set-up and Design (CED-3A) Report for IER-538, “Full Dosimetry Exercise Around Godiva Reactors” The report discusses the structure of the exercise consisting of two critical excursions, identifying the participating laboratories and their points of contact. The report also includes details of all dosimetry each laboratory will submit to be placed in proximity to Godiva-IV on aluminum plates or BOMAB phantoms. Each laboratory list the counting and spectroscopy equipment to be utilized at the LLNL NAD Laboratory in Mercury. The exercise is tentatively scheduled for one week in fiscal year 2022.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Prompt Fission Neutron Spectrum: From Experiment to the Evaluated Data and its Impact on Critical Assemblies

After a brief introduction concerning nuclear data, prompt fission neutron spectrum (PFNS) evaluations and the limited PFNS covariance data in the ENDF/B-VII library, and the important fact that cross section uncertainties ~ PFNS uncertainties, the author presents background information on the PFNS (experimental data, theoretical models, data evaluation, uncertainty quantification) and discusses the impact on certain well-known critical assemblies with regard to integral quantities, sensitivity analysis, and uncertainty propagation. He sketches recent and ongoing research and concludes with some final thoughts.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Plan for IER-443 Testing of the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor

This document provides the scope and details of the “Plan for Testing the Y-12 and AWE Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor”. Due to the relative simplicity of the testing goals, scope, and methodology, the NCSP Manager approved execution of the test when ready. No preliminary CED-1 or final design CED-2 reports were required or issued. The test will subject Criticality Accident Alarm System (CAAS) detectors supplied by Y- 12 and AWE to very intense and short duration mixed neutron and gamma radiation fields. The goals of the test will be to (1) substantiate functionality, for both existing and newly acquired Y- 12 CAAS detectors, and (2) the ability of the AWE detectors to provide quality temporal dose information after a hypothetical criticality accident. ANSI/ANS-8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates which will be achieved in this test will exceed these requirements. Pulsed radiation fields will be produced by the Godiva IV fast metal burst reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The magnitude of the pulses and the relative distances to the detectors will be varied to afford a wide range of radiation fluence and pulse widths. The magnitude of the neutron and gamma fields will be determined by reactor temperature rise to fluence and dose conversions which have been previously established through extensive measurements performed under IER-147. The requirements for CAAS systems to detect and alarm under a “minimum accident of concern” as well as other functional requirements specified in ANSI/ANS-8.3.1997, are not included in the test. Routine and periodic maintenance and calibrations performed at Y-12 and AWE are intended to provide adequate confirmation for meeting these requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Report for the Testing of the Y-12 Criticality Accident Alarm System Detectors at the Godiva IV Burst Reactor (IER-443)

This report documents the experimental conditions and final results for the performance testing of the Y-12 Criticality Accident Alarm System (CAAS) detectors at the Godiva IV Burst Reactor at the National Criticality Experimental Research Center (NCERC) at the Nevada National Security Site (NNSS). The testing followed a previously issued test plan and was conducted during the week of July 17, 2017, with completion on Thursday July 20. The test subjected CAAS detectors supplied by Y-12 to very intense and short duration mixed neutron and gamma radiation fields to establish compliance to maximum radiation and minimum pulse width requirements. ANSI/ANS- 8.3.1997 states that the “system shall be sufficiently robust as to actuate an alarm signal when exposed to the maximum radiation expected”, which has been defined at Y-12, in Documented Safety Analyses (DSAs), to be a dose rate of 10 Rad/s. ANSI/ANS-8.3.1997 further states that “alarm actuation shall occur as a result of a minimum duration transient” which may be assumed to be 1 msec. The pulse widths and dose rates provided by each burst during the test exceeded those requirements. The CAAS detectors all provided an immediate alarm signal and remained operable after the bursts establishing compliance to the requirements and fitness for re-deployment at Y-12.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Electromagnetic Near Field Measurements of Two Critical Assemblies

The reactors employed, Godiva IV and WSMR Fast Burst Reactor, are described first. Then the point reactor kinetics model, electromagnetic potential, and the measurement of kinetics quantities are successively discussed. In summary, reactor power produces measurable electric energy. The electric signal mimics power curve for prompt burst operations - features in logarithmic derivatives match. The electric signature should be dependent on the power and not the derivative; therefore, steady-state modes should be measurable.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Godiva II—An Unmoderated Pulse-Irradiation Reactor

Design features of Godiva II, the improved pulsed reactor successor to Lady Godiva, are discussed together with characteristics of power excursions, and performance is compared with that of the original Godiva. Measurements of the wait time between stepwise reactivity insertion and the occurrence of a burst are presented and compared with theory based on a statistical model of fission chains. Analytical and numerical solutions of the reactor equations are developed to reproduce experimental data and extrapolate to higher energy release. Here, consideration is also given to perturbations arising from room-returned neutrons. Two different modes of operation are discussed and some design problems of Godiva-type pulsed reactors are briefly mentioned. Typical bursts are illustrated with peak powers up to 13,000 Mw and widths at half-maximum down to 35 μsec.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Summary of GNU Octave Lady Godiva Simulator

A pseudo real-time interactive reactor simulator for the Lady Godiva reactor has been developed using the GNU Octave software package. The simulator tracks the time-dependent power and fuel temperature behavior of the Lady Godiva reactor during sub-prompt critical transients. Users interact with the simulator by controlling reactivity input. This input occurs through users repositioning a control rod as desired during simulator operation. Various reactor parameters are displayed graphically in near “real time,” facilitating user assessment and feedback input. The reactor model consists of a lumped-fuel core, a single control rod, and a simple heat transfer mechanism that allows heat to be rejected from the core. The goal of the simulator is to demonstrate in real-time the system response to reactivity perturbations, the effect of reactivity feedback, and the effect of temperature-dependent equilibrium conditions. The dynamic behavior of the reactor is primarily driven by the relative characteristic time-constants between the delayed neutrons and the overall heat transfer parameter. The simulator will allow users to gain experience performing standard reactor operations, such as establishing steady-state at different fuel temperatures and making power level changes

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Examining Computational Assumptions For Godiva IV

Over the course of summer 2016, the effects of several computational modeling assumptions with respect to the Godiva IV reactor were examined. The majority of these assumptions pertained to modeling errors existing in the control rods and burst rod. The Monte Carlo neutron transport code, MCNP, was used to investigate these modeling changes, primarily by comparing them to that of the original input deck specifications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uranium–Molybdenum Alloy Critical Experiments for the Design of the Health Physics Research Reactor

Clean critical experiments with a uranium-molybdenum alloy (average of 10.1616 wt. % Mo with a density of 17.08 g/cm 3 ) were performed at the Oak Ridge Critical Experiments Facility in 1961 to support the design of the Health Physics Research Reactor (HPRR). The HPRR was similar to the Godiva burst reactor at Los Alamos National Laboratory and was designed to produce 50 microseconds burst of 10 17 fission pulses of radiation for dosimetry measurements, initially in support of the determination of the doses from the nuclear detonations in Japan during World War II. These experiments reported here were used to verify the calculational methods used to design the HPRR. These delayed critical measurements were:1) a solid unreflected and unmoderated 8-in.-dimeter U-Mo cylinder, 2) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void, 3) an unmoderated and unreflected annulus with 8-in.-outside diameter, 2-in.-inside diameter cylinder with a central void filled with stainless steel, 4) Same as 3) but with 3-in-thick Plexiglas reflector on top with and without cadmium between the reflector and the U-Mo alloy assembly with steel in the center, and 5) an unmoderated and unreflected annulus which was a modification of the second but with the lower 5 inches of the central hole enlarged to 3.5 in. with various reflector conditions. The reflector conditions were: 1-in.-thick Plexiglas on all outer surfaces-void in the center; 1-in.-thick Plexiglas on all outer surfaces-Plexiglas in the center; 2-in.- thick Plexiglas on radial surface-void in the center; 6-in.-thick Plexiglas on the bottom only-Plexiglas in the center; and 6-in.-thick Plexiglas on bottom, 1-in.-thick on top and on the lower 8.25-cm.-section of the radial surface-void in the center. For some of these reflector conditions 0.025-cm.thick cadmium was located between the reflector and the U-Mo alloy. The uranium contained 93.17 wt. % 235 U. Reflection was a safety concern for this unmoderated and unreflected reactor and reduction of reflection effects was also investigated by insertion of neutron absorber around the U-Mo alloy. The stainless steel 304 contained 18% nickel and 8% chromium and the rest iron. The reflector material was a methacrylate plastic (Plexiglas) containing 5.8 x 10 22 atoms/cm 3 of hydrogen and 3.6 x 10 22 atoms/cm 3 of carbon with a density of 1.20 g/cm 3 . The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Nuclear Criticality Safety Benchmark Program (ICSBEP) or a EURATON Nuclear Energy Agency (NEA) benchmark. The data from the experiments described should be acceptable for use as criticality safety benchmark experiments for the ICSBEP and the NEA nuclear criticality safety benchmark program, once the uncertainty analysis is completed. Based on previous ICSBEP benchmarks with this enriched uranium metal at ORCEF, the uncertainties in k eff could be as low as ±0.0002 for some configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Disposition of fuel elements from the Aberdeen and Sandia pulse reactor (SPR-II) assemblies

We describe the disposition of fuel from the Aberdeen (APR) and the Sandia Pulse Reactors (SPR-II) which were used to provide intense neutron bursts for radiation effects testing. The enriched Uranium - 10% Molybdenum fuel from these reactors was shipped to the Los Alamos National Laboratory (LANL) for size reduction prior to shipment to the Savannah River Site (SRS) for final disposition in the H Canyon facility. The Shipper/Receiver Agreements (SRA), intra-DOE interfaces, criticality safety evaluations, safety and quality requirements and key materials management issues required for the successful completion of this project will be presented. This work is in support of the DOE Consolidation and Disposition program. Sandia National Laboratories (SNL) has operated pulse nuclear reactor research facilities for the Department of Energy since 1961. The Sandia Pulse Reactor (SPR-II) was a bare metal Godiva-type reactor. The reactor facilities have been used for research and development of nuclear and non-nuclear weapon systems, advanced nuclear reactors, reactor safety, simulation sources and energy related programs. The SPR-II was a fast burst reactor, designed and constructed by SNL that became operational in 1967. The SPR-ll core was a solid-metal fuel enriched to 93% {sup 235}U. The uranium was alloyed with 10 weight percent molybdenum to ensure the phase stabilization of the fuel. The core consisted of six fuel plates divided into two assemblies of three plates each. Figure 1 shows a cutaway diagram of the SPR-II Reactor with its decoupling shroud. NNSA charged Sandia with removing its category 1 and 2 special nuclear material by the end of 2008. The main impetus for this activity was based on NNSA Administrator Tom D'Agostino's six focus areas to reenergize NNSA's nuclear material consolidation and disposition efforts. For example, the removal of SPR-II from SNL to DAF was part of this undertaking. This project was in support of NNSA's efforts to consolidate the locations of special nuclear material (SNM) to reduce the cost of securing many SNM facilities. The removal of SPR-II from SNL was a significant accomplishment in SNL's de-inventory efforts and played a key role in reducing the number of locations requiring the expensive security measures required for category 1 and 2 SNM facilities. A similar pulse reactor was fabricated at the Y-12 National Security Complex beginning in the late 1960's. This Aberdeen Pulse Reactor (APR) was operated at the Army Pulse Radiation Facility (APRF) located at the Aberdeen Test Center (ATC) in Maryland. When the APRF was shut down in 2003, a portion of the DOE-owned Special Nuclear Material (SNM) was shipped to an interim facility for storage. Subsequently, the DOE determined that the material from both the SPR-II and the APR would be processed in the H-Canyon at the Savannah River Site (SRS). Because of the SRS receipt requirements some of the material was sent to the Los Alamos National Laboratory (LANL) for size-reduction prior to shipment to the SRS for final disposition.

36 MATERIALS SCIENCE↗

Godiva and Juliet Diagnostics CED-1 (IER-176)

A suite of diagnostics are being proposed for use in the Juliet experiment (IER-128). In order to calibrate and test the diagnostics prior to use, the LLNL calibration facility and Godiva pulsed reactor will be used to provide intense sources of neutrons and gammas. Due to the similarities of the Godiva and Juliet radiation fields, the diagnostics being developed and tested for Juliet can also play an on-going role in diagnostics for Godiva as well as, perhaps, other critical assembly experiments. Similar work is also being conducted for IER-147 for the purpose of characterizing the Godiva radiation field in support of an upcoming international nuclear accident dosimetry exercise. Diagnostics developed and fielded under IER-147 can provide valuable data with respect to the neutron and gamma energy spectrums in the vicinity of Godiva which is relevant to the calibration of Juliet diagnostics.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Critical Experiment Accidents - Redux

Much has been written regarding "process accidents" in the realm of criticality safety. Indeed, great effort has been put toward analyzing the accidents for lesson-learned and toward the development of models to predict the behavior of process systems in support of safety cases an emergency response. Less effort has been levied toward the lessons-learned and modeling of critical experiment accidents. Perhaps this stems from the tenets of criticality safety: Fissionable material processes shall be determined to be subcritical under both normal and credible abnormal conditions. Given the imminent startup of the Criticality Experiments Facility (CEF) at the Nevada National Security Site, an examination of critical experiment accidents for lessons-learned is prudent to ensure that the benefit of past experience is applied to CEF operations. In this paper, the history of critical experiment accidents is reviewed and lessons-learned relevant to CEF are discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

UPF and Y-12 Criticality Accident Alarm System (CAAS) Radiation Testing Report

This report documents the experimental conditions and results for the testing of the Mirion Technologies CAAS-3S Criticality Accident Alarm System (CAAS) for the Y-12 National Security Complex (Y-12) and Uranium Processing Facility (UPF). The testing was conducted at the Godiva IV Burst Reactor at the National Criticality Experiments Research Center (NCERC) at the Nevada National Security Site (NNSS) during the week of January 11, 2021. The testing was conducted in accordance with 25774-QL-POA-JR00-00002-VDE-27.0, CAAS-3S Radiation Testing of Cabinet Components Test Plan. The tests subjected the CAAS-3S system to intense and short duration mixed neutron and gamma radiation fields and to high integrated radiation doses. The purpose of the test was to environmentally qualify various CAAS-3S components in a radiation environment. Successful completion of the tests was predicated on the collaborative efforts of several organizations. Sandia National Laboratory (SNL) and Lawrence Livermore National Laboratory (LLNL) provided dosimetry to estimate photon and neutron dose. Los Alamos National Laboratory (LANL) manages the NCERC facility, operated the Godiva IV reactor, and provided field support for CAAS-3S placement and communications interface for data acquisition systems supplied by Mirion Technologies. Throughout the test campaign, Y-12 and UPF personnel provided technical support in determining changes to the test schedule, as needed, interpretation of the results, and comparison between the measured dosimetry data and predicted results. Throughout the test campaign, Mirion personnel provided technical support in the operation of the CAAS-3S system itself.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monte Carlo Direct Simulation Method for Initiation Probability Problems

During the early period of a supercritical system, the growth of fission chains shows a significant stochastic feature. In multiplying medium, it is a probability issue of fail-pass type for a single neutron to sponsor a divergent fission chain, and the probability of success is named as single neutron initiation probability. Meanwhile, in the presence of a weak neutron source, the time at which fission burst occurs also exhibits a stochastic nature, which can be observed on experiments of pulsed reactors such as GODIVA I and GODIVA II. The initiation probability and burst waiting time reflect the dynamic feature of a supercritical system, which are very important for nuclear criticality safety concerns. It is desirable that a supercritical system has an initiation probability very close to zero and releases limited energy in case of criticality accidents. The stochastic process of neutron population evolution in early age in a multiplying system is governed by Bell's equation in the form of an adjoint neutron transport equation with a non-linear fission term. In order to solve this stochastic neutron transport equation, the deterministic method discretizing the phase space was proposed long ago and has been implemented in several SN codes such as Partisn, Ardra and PANDA. However, the deterministic method is of limited usage, due to its poor ability to precisely describe real-world 3D complex geometries and continuous energy neutron spectrum. Recently, Monte Carlo methods have gradually gained attention for solving Bell's equation. Greenman from LLNL proposed an analog Monte Carlo forward-transport method for calculating initiation probability in 2007. He implemented this method by introducing the maximum age parameter, the time sub-interval and the neutron progenitor tag into Mercury in time-dependent fixed-source simulation mode. This method is only suitable for initiation probability calculations, however not for analyzing the randomness of burst waiting time. Later, GANG in 2011 developed the GSMP (Generalized Semi-Markov Process method) Monte Carlo method according to Bell's equation. While the GSMP method, which can deal with both initiation probability and burst waiting time, is flexible and powerful for zero-dimensional problems, it is not favorable when extended to 3D and continuous energy problems due to severe lack of computational efficiency. In 2015, a direct Monte Carlo simulation method for stochastic systems problems was implemented in MCATK, yet this method has not been applied specifically to the burst waiting time. In this work, a new and efficient 3D Monte Carlo direct simulation method for calculating both the initiation probability and the burst waiting time is developed. By taking random factors during evolvement of fission chains into account in dynamic Monte Carlo simulation, this new method has the potential of simulating the whole process from source neutron injection to exponential growth of the neutron population, and finally to extinction of the neutron pulse. This capability is useful in criticality accidents evaluation and pulsed reactor experiments explanation. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗