One-dimensional air temperature measurements by air resonance enhanced multiphoton Ionization thermometry (ART)

In this work, a detailed calibration study is performed to establish non-intrusive one-dimensional (1D) rovibrational temperature measurements in unseeded air, based on air resonance enhanced multiphoton ionization thermometry (ART). ART is generated by REMPI (resonance enhanced multi-photon ionization) of molecular oxygen and subsequent avalanche ionization of molecular nitrogen in a single laser pulse. ART signal, the fluorescence from the first negative band of molecular nitrogen, is directly proportional to the 2-photon transition of molecular oxygen C 3 Π (v = 2) ← X 3 Σ (v’=0), which is used to determine temperature. Experimentally, hyperfine structures of the O 2 rotational branches with high temperature sensitivity are selectively excited through a frequency-doubled dye laser. Electron-avalanche ionization of N 2 results in the fluorescence emissions from the first negative bands of N 2 + near 390, 425, and 430nm, which are captured as a 1D line by a gated intensified camera. Post processing of the N 2 + fluorescence yields a 1D thermometry line that is representative of the air temperature. It is demonstrated that the technique provides ART fluorescence of ∼5cm in length in the unseeded air, presenting an attractive thermometry solution for high-speed wind tunnels and other ground test facilities.

42 ENGINEERING↗

Facile synthesis and temperature-dependent luminescence of single-phase dual-emitting CdTe@NaNO{sub 3} composite

Graphical abstract: Single-phase dual-emitting CdTe@NaNO{sub 3} composite was prepared by a facile and efficient aqueous ethanol phase assisted coprecipitation method. Its use in self-referencing luminescent thermometry was tested, by exploiting the temperature-dependence of fluorescence intensity ratio (green/red) in range of 273–473 K. - Highlights: • Single-phase green and red dual-emitting CdTe@NaNO{sub 3} composite was prepared. • CdTe QDs embedded in NaNO{sub 3} matrices exhibit photoluminescence quantum yields of 35%. • Temperature-dependent luminescent properties of CdTe@NaNO{sub 3} composite were studied. • It could be a good candidate for ratiometric temperature sensing with a high relative sensitivity. - Abstract: Single-phase dual-emitting CdTe@NaNO{sub 3} composite was prepared by a facile and efficient aqueous ethanol phase assisted coprecipitation method, providing a new type of solid-state luminescent material with processability, robustness and high luminescence. Cubic-shape Green + Red (G + R) CdTe@NaNO{sub 3} composite particles display single-excitation, dual-emission with two well-resolved, intensity-comparable fluorescence peaks. Its application potential in ratiometric luminescent thermometry was tested, by exploiting the temperature-dependence of fluorescence intensity ratio (green/red) in range of 273–473 K, and the maximum sensitivity is found to be 0.6183% K{sup −1} at 473 K. The results indicate that dual-emitting G + R CdTe@NaNO{sub 3} composite could be considered as potential candidates for ratiometric temperature sensing.

36 MATERIALS SCIENCE↗

One dimensional temperature measurements by resonantly ionized photoemission thermometry of molecular nitrogen

This paper presents an extensive parameter study of a non-intrusive and non-seeded laser diagnostic method for measuring one dimensional (1D) rotational temperature of molecular nitrogen (N 2 ) at 165 - 450 K. Compared to previous efforts using molecular oxygen, here resonantly ionized and photoelectron induced fluorescence of molecular nitrogen for thermometry (N 2 RIPT) was demonstrated. The RIPT signal is generated by directly probing various rotational levels within the rovibrational absorption band of N 2 , corresponding to the 3-photon transition of N 2 ( X 1 Σ g + , v =0→ b 1 Π u , v ′ =6) near 285 nm, without involving collisional effects of molecular oxygen and nitrogen. The photoionized N 2 produces strong first negative band of N 2 + ( B 2 Σ u + − X 2 Σ g + ) near 390 nm, 420 nm, and 425 nm. Boltzmann analyses of various discrete fluorescence emission lines yield rotational temperatures of molecular nitrogen. By empirically choosing multiple rotational levels within the absorption band, non-scanning thermometry can be accurately achieved for molecular nitrogen. It is demonstrated that the N 2 RIPT technique can measure 1D temperature profile up to ∼5 cm in length within a pure N 2 environment. Multiple wavelengths are thoroughly analyzed and listed that are accurate for RIPT for various temperature ranges.

McCord, Walker (ORCID:0000000179747550)↗

Single-pulse gas thermometry at low temperatures using two-photon laser-induced fluorescence in NO-N2 mixtures

A technique suitable for measuring fluctuating temperatures in supersonic turbulent flows of N2 seeded with NO has been demonstrated in a nonflowing cell. The method relies on the two photon excitation of two selected ro-vibronic transitions in the NO gamma (alpha 2 sigma+, v prime = 0 yields ch1zp1, v double prime = 0). Previously announced in STAR as N83-20079

Gross, K. P.↗

Containerless Atomic-Fluorescence Property Measurements

Report describes studies conducted to establish and verify use of laser-induced fluorescence in monitoring and controlling high-temperature containerless processes. Specimens levitated by gas jets or electromagnetic fields and heated by laser beams or electromagnetic induction while being irradiated and detected by fluorescence technique. Makes quantitative and qualitative comparisons among three new methods of temperature measurement; all rely on laser-induced fluorescence. One method gas-density thermometry with seed gas. Other two methods involve measurements of velocities of evaporating atoms or of population ratios of different electronic states.

Nordine, P.↗

From Wind Tunnels to Flight Vehicles: Visualization and quantitative measurements supporting NASA’s space program

NASA’s Space Launch System (SLS) and Orion Crew Module have been studied in wind tunnels using the planar laser-induced fluorescence (PLIF) technique for flow visualization and quantitative thermometry and in flight using high-resolution imagery and quantitative infrared surface heating measurements. This paper reviews both types of measurements. OCIS codes: (120.1740) Combustion diagnostics; (300.2530) Fluorescence, laser-induced; (110.3080) Infrared imaging.

Planar Laser-Induced Fluorescence (PLIF)↗

Seeing in with X-rays: 4D Strain and Thermometry Measurements for Thermal-Mechanical Testing

Understanding temperature-dependent material decomposition and structural deformation induced by combined thermal-mechanical environments is critical for safety qualification of hardware under accident scenarios. Seeing in with X-rays elucidated the physics necessary to develop X-ray strain and thermometry diagnostics for use in optically opaque environments. Two parallel thermometry schemes were explored: X-ray fluorescence and X-ray diffraction of inorganic doped ceramics– colloquially known as thermographic phosphors. Two parallel surface strain techniques–Path-Integrated Digital Image Correlation and Frequency Multiplexed Digital Image Correlation–were demonstrated. Finally, preliminary demonstration of time-resolved digital volume correlation was performed by taking advantage of limited view reconstruction techniques. Additionally, research into blended ceramic-metal coatings was critical to generating intrinsic thermographic patterns for the future combination of X-ray strain and thermometry measurements.

36 MATERIALS SCIENCE↗

Temperature-dependent x-ray fluorescent response from thermographic phosphors under x-ray excitation

Phosphor thermometry has been successfully applied within several challenging environments. Typically, the thermographic phosphors are excited by an ultraviolet light source, and the temperature-dependent spectral or temporal response is measured. However, this is challenging or impossible in optically thick environments. In addition, emission from other sources (e.g., a flame) may interfere with the optical phosphor emission. Furthermore, a temperature dependent x-ray excitation/emission could alleviate these issues as x-rays could penetrate obscurants with no interference from flame luminosity. In addition, x-ray emission could allow for thermometry within solids while simultaneously x-ray imaging the structural evolution. In this study, select thermographic phosphors were excited via x-ray radiation, and their x-ray emission characteristics were measured at various temperatures. Several of the phosphors showed varying levels of temperature dependence with the strongest sensitivity occurring for YAG:Dy and ZnGa 2 O 4 :Mn. This approach opens a path for less intrusive temperature measurements, particularly in optically opaque multiphase and solid phase combustion environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Non-contact temperature measurement

Three methods for noncontact temperature measurement are presented. Ideal gas thermometry is realized by using laser-induced fluorescence to measure the concentration of mercury atoms in a Hg-Ar mixture in the vicinity of hot specimens. Emission polarimetry is investigated by measuring the spatially resolved intensities of polarized light from a hot tungsten sphere. Laser polarimetry is used to measure the optical properties, emissivity, and, in combination with optical pyrometry, the temperature of electromagnetically levitated liquid aluminum. The precision of temperature measurements based on the ideal gas law is + or - 2.6 percent at 1500-2000 K. The polarized emission technique is found to have the capability to determine optical properties and/or spectral emissivities of specimens over a wide range of wavelengths with quite simple instruments.

Nordine, Paul C.↗

Laser Optogalvanic Spectroscopy pf Neon and Argon in a Discharge Plasma and its Significance for Microgravity Combustion

A detailed study of combustion mechanisms in flames, employing laser-based diagnostics, has provided good knowledge and understanding of the physical phenomena, and led to better characterization of the dynamical and chemical combustion processes, both under low-gravity (in space) and normal gravity (in ground based facilities, e.g. drop towers). Laser induced fluorescence (LIF), laser-induced incandescence (LII) and LIF thermometry have been widely used to perform nonintrusive measurements and to better understand combustion phenomena. Laser optogalvanic (LOG) spectroscopy has well-established applications in ion mobility measurements, atomic and molecular spectroscopy, ionization rates, recombination rates, velocity measurements and as a combustion probe for trace element detection. Absorption spectra of atomic and molecular species in flames can be obtained via LOG spectroscopy by measuring the voltage and current changes induced by laser irradiation. There are different kinds of processes that contribute to a discharge current, namely: (1) electron impact ionization, (2) collisions among the excited atoms of the discharge species and (3) Penning ionization. In general, at higher discharge currents, the mechanism of electron impact ionization dominates over Penning ionization, whereby the latter is hardly noticeable. In a plasma, whenever the wavelength of a laser coincides with the absorption of an atomic or molecular species, the rate of ionization of the species momentarily increases or decreases due to laser-assisted acceleration of collisional ionization. Such a rate of change in the ionization is monitored as a variation in the transient current by inserting a high voltage electrode into the plasma. Optogalvanic spectroscopy in discharges has been useful for characterizing laser line-widths and for providing convenient calibration lines for tunable dye lasers in the ultraviolet, visible and infrared wavelength regions. Different kinds of quantitative information, such as the electron collisional ionization rate, can be extracted from the complex processes occurring within the discharge. In the optogalvanic effect (OGE), there is no problem of overlap from background emissions, and hence even weak signals can be detected with a high signal-to-noise ratio, which makes the optogalvanic effect sensitive enough to resolve vibrational changes in molecular bonds and differences in energy levels brought about by different electron spins. For calibration purposes, neon and argon gaseous discharges have been employed most extensively, because these gases are commonly used as buffer gases within hollow-cathode lamps and provide an acceptable density of calibration lines. In the present work, our main aim has been to understand the dominant physical processes responsible for the production of the OGE signal, based on the extensive time resolved optogalvanic waveforms recorded, and also to extract quantitative information on the rates of excited state collisional processes.

Misra, Prabhakar↗

NO PLIF Rotational Thermometry Characterization of a Hypersonic Boundary Layer

Nitric oxide (NO) planar laser-induced fluorescence (PLIF) was performed to determine rotational temperature profiles and fluctuations within a hypersonic boundary layer above the surface of a 2.75° half-angle wedge. The experiments were performed in the Texas A&M University Actively Controlled Expansion (ACE) hypersonic blow-down wind tunnel at Mach = 5.7 and 𝑅𝑒 = 6 × 10 6 /m. The NO was introduced to the flow in the settling chamber of the ACE tunnel and probed using two laser sheets near 226 nm. The resulting NO PLIF fluorescence signal was acquired using in-house software, which simultaneously recorded tunnel conditions. After a Fast Fourier Transform (FFT) blurring and statistical treatment was performed, the preshock temperature was evaluated to be 58 ± 2 K (3.5%), while the turbulent boundary layer temperature near the wall was found to be 350 K with fluctuations on the order of ±25 K (7%). The relative temperature fluctuations were determined to be 3 − 5% in the freestream and peaked at 33% in the turbulent boundary layer. The advantages and disadvantages of seeding NO in the tunnel settling chamber for thermometric PLIF measurements are discussed.

Hypersonics↗

High-Speed Diagnostic and Simulation Capabilities for Reacting Hypersonic Reentry Flows (LDRD Final Report)

High-enthalpy hypersonic flight represents an application space of significant concern within the current national-security landscape. The hypersonic environment is characterized by high-speed compressible fluid mechanics and complex reacting flow physics, which may present both thermal and chemical nonequilibrium effects. We report on the results of a three-year LDRD effort, funded by the Engineering Sciences Research Foundation (ESRF) investment area, which has been focused on the development and deployment of new high-speed thermochemical diagnostics capabilities for measurements in the high-enthalpy hypersonic environment posed by Sandia's free-piston shock tunnel. The project has additionally sponsored model development efforts, which have added thermal nonequilibrium modeling capabilities to Sandia codes for subsequent design of many of our shock-tunnel experiments. We have cultivated high-speed, chemically specific, laser-diagnostic approaches that are uniquely co-located with Sandia's high-enthalpy hypersonic test facilities. These tools include picosecond and nanosecond coherent anti-Stokes Raman scattering at 100-kHz rates for time-resolved thermometry, including thermal nonequilibrium conditions, and 100-kHz planar laser-induced fluorescence of nitric oxide for chemically specific imaging and velocimetry. Key results from this LDRD project have been documented in a number of journal submissions and conference proceedings, which are cited here. The body of this report is, therefore, concise and summarizes the key results of the project. The reader is directed toward these reference materials and appendices for more detailed discussions of the project results and findings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature-dependent fluorescence decay lifetimes of the phosphor Y3(Al0.5Ga0.5)5O12:Ce 1%

The decay time of the phosphor YAG:Ce is temperature dependent. Selective incorporation of gallium into the YAG:Ce matrix permits tuning the temperature at which quenching begins. Also, the size of the phosphor particle and processing method affect this characteristic. We describe one such situation in which quenching of the combustion synthesized nanophosphor Y3(Al0.5Ga0.5)5O12:Ce 1% was observed from ambient to 125 C. By signal averaging of laser excited fluorescence, temperature uncertainties ranged from 0.05 to 0.15 C. The single shot temperature uncertainty at 115 C was 3 C, indicating the feasibility for transient thermometry with response rate exceeding 1 MHz.

36 MATERIALS SCIENCE↗

Highly sensitive up-conversion optical thermometry based on Yb3+-Er3+ co-doped NaLa(MoO4)2 green phosphors

Highlights: • Phosphors NaLa(MoO{sub 4}){sub 2}:Er{sup 3+}/Yb{sup 3+} UC with intense green emission were synthesized. • The thermometric property based on FIR {sup 2}H{sub 11/2}/{sup 4}S{sub 3/2} → {sup 4}I{sub 15/2} was evaluated. - Abstract: Pursuing highly sensitive thermometry is a permanent goal in recent scientific research, which can be achieved through Fluorescence intensity ratio (FIR) technique due to its fast response, excellent accuracy, high spatial resolution and tunable size. Herein, highly sensitive micro-thermometers based on FIR of the thermal coupled levels (TCLs) {sup 2}H{sub 11/2}/{sup 4}S{sub 3/2} → {sup 4}I{sub 15/2} from Er{sup 3+} in phosphors NaLa(MoO{sub 4}){sub 2}: Yb{sup 3+}/Er{sup 3+} up-conversion (UC) were developed, which emits dazzling green light with the excitation of 980 nm laser and its UC spectra consisted of intense green bands peaked at 530 and 552 nm and a negligible 658 nm red emission ({sup 4}F{sub 9/2} → {sup 4}I{sub 15/2}), respectively. The maximum absolute sensitivity approached to 0.023 K{sup -1} at 490 K through assessing FIR based on thermo-responsive green emissions. Results suggest the present green-emitting phosphors have great potential to serve as UC thermometers with high and stable sensitivity, which greatly meet the growing demand for sensing applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental and numerical study of the role of NCN in prompt-NO formation in low-pressure CH{sub 4}-O{sub 2}-N{sub 2} and C{sub 2}H{sub 2}-O{sub 2}-N{sub 2} flames

We report an experimental and modeling study on prompt-NO formation in low-pressure (5.3 kPa) premixed flames. Special emphasis is given to the quantitative detection (and prediction) of NCN, whose role in prompt-NO formation has recently been confirmed in alkane flames. Here a rich ({phi} = 1.25) CH{sub 4}-O{sub 2}-N{sub 2} flame and rich ({phi} = 1.25) and stoichiometric C{sub 2}H{sub 2}-O{sub 2}-N{sub 2} flames have been investigated. Absolute concentration profiles of CH and NCN radicals and NO species are obtained by combining laser-induced fluorescence (LIF) and cavity ring-down spectroscopy (CRDS). Temperature profile is determined in each flame using OH and NO-LIF thermometry. Flame modeling is performed to determine the role of NCN in prompt-NO formation and to test the capacity of the present chemical mechanisms to predict some intermediate species involved in prompt-NO formation. The methane flame is modeled using GDFkin registered 3.0{sub N}CN mechanism [El Bakali et al., Fuel 85 (2006), 896-909]. The acetylene flames are modeled using the Lindstedt and Skevis C/H/O mechanism [Lindstedt and Skevis, Proc. Combust. Inst. 28 (2000), 1801-1807], completed by the submechanism issued from GDFkin registered 3.0{sub N}CN for nitrogen chemistry. This submechanism includes the initiation reaction CH + N{sub 2} = NCN + H. Rate constants of NO-sensitive reactions of the submechanism are modified by taking into account the recent literature. In particular, the C{sub 2}O route could be explored thanks to a significant presence of C{sub 2}O in acetylene flames. Globally, the modified submechanism of nitrogen chemistry coupled with the two hydrocarbon mechanisms leads to a satisfying prediction of NCN and NO mole fraction profiles, even though refinements of rate constant determination is still required. The role of NCN in prompt-NO formation in acetylene flames is demonstrated. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Report of the EMI Testing of the Johnson Noise Thermometry System

This report summarizes the Electromagnetic Interference (EMI) testing of the Johnson Noise Thermometry System developed at ORNL. The EMI performance is very important for Johnson Noise Thermometry because it requires accurate measurement of a very small noise signal that is amplified 10,000 times. Any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Testing is therefore very important in determining the effects of these external noise sources. Results from testing in several environments with various sources of EMI are presented here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Innovative signal processing for Johnson Noise thermometry

This report summarizes the newly developed algorithm that subtracted the Electromagnetic Interference (EMI). The EMI performance is very important to this measurement because any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Two methods of removing EMI were developed and tested at various locations. This report also summarizes the testing performed at different facilities outside Oak Ridge National Laboratory using both EMI removal techniques. The first EMI removal technique reviewed in previous milestone reports and therefore this report will detail the second method.

97 MATHEMATICS AND COMPUTING↗