Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flowmeters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Experimental study of a vortex-shedding flowmeter

A prototype of a vortex-shedding flowmeter with no moving parts is investigated for the loading of hypergolic fuels into the Space Shuttle Orbiter. Eliminating moving parts is intended to reduce the need for servicing the meter, and the vortex shedder is compared to the turbine flowmeter presently in use. A flow test loop is designed and employed to conduct experimental investigations in which the output characteristics are examined. The relationship between vortex frequency and flow rate is almost linear, as is the relationship between vortex shedding frequency and the Reynolds and Strouhal numbers. The results are consistent with calculations and suggest that the flowmeter is a possible replacement for measuring the loading of hypergols into the Space Shuttle Orbiter.

Thinh, Ngo D.↗

The Effect of Acoustic Disturbances on the Operation of the Space Shuttle Main Engine Fuel Flowmeter

The Space Shuttle Main Engine (SSME) uses a turbine fuel flowmeter (FFM) in its Low Pressure Fuel Duct (LPFD) to measure liquid hydrogen flowrates during engine operation. The flowmeter is required to provide accurate and robust measurements of flow rates ranging from 10000 to 18000 GPM in an environment contaminated by duct vibration and duct internal acoustic disturbances. Errors exceeding 0.5% can have a significant impact on engine operation and mission completion. The accuracy of each sensor is monitored during hot-fire engine tests on the ground. Flow meters which do not meet requirements are not flown. Among other parameters, the device is screened for a specific behavior in which a small shift in the flow rate reading is registered during a period in which the actual fuel flow as measured by a facility meter does not change. Such behavior has been observed over the years for specific builds of the FFM and must be avoided or limited in magnitude in flight. Various analyses of the recorded data have been made prior to this report in an effort to understand the cause of the phenomenon; however, no conclusive cause for the shift in the instrument behavior has been found. The present report proposes an explanation of the phenomenon based on interactions between acoustic pressure disturbances in the duct and the wakes produced by the FFM flow straightener. Physical insight into the effects of acoustic plane wave disturbances was obtained using a simple analytical model. Based on that model, a series of three-dimensional unsteady viscous flow computational fluid dynamics (CFD) simulations were performed using the MSFC PHANTOM turbomachinery code. The code was customized to allow the FFM rotor speed to change at every time step according to the instantaneous fluid forces on the rotor, that, in turn, are affected by acoustic plane pressure waves propagating through the device. The results of the simulations show the variation in the rotation rate of the flowmeter due to the interaction of the flow straightener wakes and the upstream propagating acoustic waves. A detailed analysis of the acoustic disturbance effects is presented along with an assessment of the impact on measurement accuracy.

Marcu, Bogdan↗

A theoretical model for determining turbine flowmeter sensitivity

Analytical model of turbine-type flowmeter guides in the selection of valid extrapolation of available calibration data. An expression for flowmeter performance is developed to include the effects of fluid friction, bearing drag, and magnetic drag upon helical rotor design.

Smith, R. L.↗

Flowmeter determines mix ratio for viscous adhesives

Flowmeter determines mix ratio for continuous flow mixing machine used to produce an adhesive from a high viscosity resin and aliphatic amine hardener pumped through separate lines to a rotary blender. The flowmeter uses strain gages in the two flow paths and monitors their outputs with appropriate instrumentation.

Lemons, C. R.↗

Nonintrusive dynamic flowmeter

Description of some of the design and performance characteristics of an ultrasonic dynamic flowmeter which combines nonintrusiveness, fast response, high accuracy, and high resolution and is intended for use with cryogenic liquids and water. The flowmeter measures to 1% accuracy the dynamic as well as the steady flow velocity averaged over the pipe area.

Pedersen, N. E.↗

Dynamic calibration of flowmeter

Technique for flowmeters has been developed and tested whereby fluid flows through meter at constant velocity while flowmeter is forced to oscillate relative to fluid.

Herr, R. W.↗

Differential oil flowmeter

Difference in oil flow volume through two mechanical flowmeters is converted to analog signal by simple inexpensive circuit. Circuit can be implemented with only minor changes to conventional oil flowmeters and used to measure fuel consumed by oil fired furnace or water heater.

Powers, W. T.↗

An ultrasonic flowmeter for measuring dynamic liquid flow

A novel oscillating pipe system was developed to provide dynamic calibration wherein small sinusoidal signals with amplitudes of 0.5 to 10% of the steady-state flow were added to the steady-state flow by oscillating the flowmeter relative to the fixed pipes in the flow system. Excellent agreement was obtained between the dynamic velocities derived from an accelerometer mounted on the oscillating pipe system and those sensed by the flowmeter at frequencies of 7, 19, and 30 Hz. Also described were the signal processing techniques used to retrieve the small sinusoidal signals which were obscured by the fluid turbulence.

Carpini, T. D.↗

Automatic flowmeter calibration system

A system for automatically calibrating the accuracy of a flowmeter is described. The system includes a calculator capable of performing mathematical functions responsive to receiving data signals and function command signals. A prover cylinder is provided for measuring the temperature, pressure, and time required for accumulating a predetermined volume of fluid. Along with these signals, signals representing the temperature and pressure of the fluid going into the meter are fed to a plurality of data registers. Under control of a progress controller, the data registers are read out and the information is fed through a data select circuit to the calculator. Command signals are also produced by a function select circuit and are fed to the calculator set indicating the desired function to be performed. The reading is then compared with the reading produced by the flowmeter.

Lisle, R. V.↗

A new technique for measuring gas conversion factors for hydrocarbon mass flowmeters

A technique for measuring calibration conversion factors for hydrocarbon mass flowmeters was developed. It was applied to a widely used type of commercial thermal mass flowmeter for hydrocarbon gases. The values of conversion factors for two common hydrocarbons measured using this technique are in good agreement with the empirical values cited by the manufacturer. Similar agreements can be expected for all other hydrocarbons. The technique is based on Nernst theorem for matching the partial pressure of oxygen in the combustion product gases with that in normal air. It is simple, quick and relatively safe--particularly for toxic/poisonous hydrocarbons.

Singh, J. J.↗

New technique for calibrating hydrocarbon gas flowmeters

A technique for measuring calibration correction factors for hydrocarbon mass flowmeters is described. It is based on the Nernst theorem for matching the partial pressure of oxygen in the combustion products of the test hydrocarbon, burned in oxygen-enriched air, with that in normal air. It is applied to a widely used type of commercial thermal mass flowmeter for a number of hydrocarbons. The calibration correction factors measured using this technique are in good agreement with the values obtained by other independent procedures. The technique is successfully applied to the measurement of differences as low as one percent of the effective hydrocarbon content of the natural gas test samples.

Singh, J. J.↗

Positioning Rotors In Turbine Flowmeters

Lengths of wakes roughly proportional to thickness of vanes. Mathematical model simplifies analysis of effects of flow-straightening vanes in turbine flowmeter. Yields numerical solution of differential equations of flow for quick examination of efforts of thicknesses of vanes and rate of flow on extent of wake behind vanes. From examination, minimum distance at which flowmeter rotor placed behind vanes determined.

Lynch, Edward D.↗

Self-Calibrating Respiratory-Flowmeter Combination

Dual flowmeters ensure accuracy over full range of human respiratory flow rates. System for measurement of respiratory flow employs two flowmeters; one compensates for deficiencies of other. Combination yields easily calibrated system accurate over wide range of gas flow.

Westenskow, Dwayne R.↗

SHOOT flowmeter and pressure transducers

A venturi flowmeter has been designed and constructed for the Superfluid Helium On-Orbit Transfer (SHOOT) experiment. The calibration results obtained from the SHOOT venturi demonstrate the ability of the flowmeter to meet the requirements of the SHOOT experiment. Flow rates as low as 20 cu dm/h and as high as 800 cu dm/h have been measured. Performances of the SHOOT differential and absolute pressure transducers, which have undergone calibration and vibration tests, are also included. Throughout the tests, the responses of the transducers remained linear and repeatable to within + or - 1 percent of the full scales of the transducers.

Kashani, A.↗

Strong, Ductile Rotor For Cryogenic Flowmeters

Improved magnetic flowmeter rotor resists cracking at cryogenic temperatures, yet provides adequate signal to magnetic pickup outside flowmeter housing. Consists mostly of stainless-steel alloy 347, which is ductile and strong at low temperatures. Small bead of stainless-steel alloy 410 welded in groove around circumference of round bar of stainless-steel alloy 347; then rotor machined from bar. Tips of rotor blades contain small amounts of magnetic alloy, and passage of tips detected.

Royals, W. T.↗

Space Shuttle Hypergol Load Determination Using Nonintrusive Ultrasonic Flowmeters

Space Shuttle preflight hypergol oxidizer and fuel loading were monitored using a nonintrusive flow measurement system (NFMS) during preflight operation. A pair of 4-megahertz ultrasonic transducers measured the flow rate using a transit-time flow measurement technique. Using wireless cellular phone technology, flow-rate data was monitored and recorded. Excellent correlation was observed between the flow profiles measured using the proposed nonintrusive ultrasonic flowmeters (UFM's) and those made from conventional intrusive turbine meters (TFM). Based on the preliminary tests, it is concluded that the nonintrusive method of flow measurement has the same or higher accuracy, is simpler, and costs less than the existing TFM. Benefits of UFM's include a highly flexible, cost-effective, reliable, hazard free, and streamlined hypergol operation. Redundant installation of ultrasonic flowmeters was recommended for a few more launches prior to the replacement of the existing TFM.

Werlink, Rudolph↗

Aeroacoustic flowmeter

The flowmeter is based on a measurement of phase difference between two points on the circumference of a pipe separated axially by an integral multiple of sound wavelength. Plane sound waves are generated aeroacoustically by a non-protruding ring cavity energized either directly by the flow or by a subsidiary flow of the same medium. The frequency of the aeroacoustic source varies with temperature and therefore the temperature can be obtained. In the case of steam flow, temperature can be measured independently and therefore from the measured frequency (or speed of sound), the quality of wet steam can be measured. The flowmeter is linear in velocity and no calibrations are required.

Shakkottai, Parthasarathy↗

Off-Earth Servicing Component Advancement (OESCA) Flight-like Coriolis Mass Flowmeter Development

With the completion of this initial technology development effort, additional work will be required for infusion and advancement through TRL 7. The remainder of the flight-level environmental testing (electromagnetic interference and compatibility or electromagnetic interference/electromagnetic compatibility (EMI/EMC), thermal vacuum or TVAC, along with vibration and shock testing) and post-test functional checkouts will need to be completed and are currently planned as part of an awarded STMD Early Career Initiative (ECI) Project called Advancement of Exploration Components for In-Space Servicing or AXCIS. The results and reports from these additional tests during the ECI effort will complete the technology development package, advancing the TRL to 5 or 6 while providing a vendor capable of manufacturing flight units and a flight-ready design as well as lessons-learned from the environmental testing. The Coriolis flowmeter development unit would then be incorporated into a demonstration testbed system for microgravity testing to further understand how it functions and performs in a space-like environment, advancing the developed technology to TRL 6 or 7. Following this infusion path will enable NASA program(s)/proposal(s) to procure a flight-rated high accuracy Coriolis mass flowmeter for incorporation into in-space and Lunar/Martian surface spacecraft propellant resupply systems which, after successful mission use, will bring the TRL to 7+.

Amy Felt↗