Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Enclosures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Arc Weld Robotic Arm & Enclosure Seismic Anchorage in B226

The Arc Weld Robotic Arm & Enclosure is adequately anchored by the details shown on sheets SKS-01 through SKS-03. Two different Hilti anchors have been provided to allow for installation flexibility. Existing documentation shows that the existing enclosure base has been anchored with 5/8”Ø Kwik Bolt TZ’s. As a result, it is believed that the existing holes are sized for that 5/8”Ø anchor. The first option is to install a 5/8”Ø Kwik Bolt TZ2, similarly to the existing conditions. The second option is to use a threaded insert anchor. Since the largest allowable diameter of HIS-N insert is 1/2”Ø based on the slab thickness, 2”x2” square plate washers with a 9/16”Ø hole will need to be installed on the top of the existing enclosure base plates to reduce the diameter of the existing holes. This is required for the anchorage to provide proper restraint in a seismic event.

42 ENGINEERING↗

Radiative equilibrium in a rectangular enclosure bounded by gray walls

Two-dimensional temperature and heat-flux distributions are calculated for an absorbing-emitting gray medium at radiative equilibrium in a rectangular enclosure. The bounding walls are gray and diffuse with arbitrary surface-temperature distributions, and heat generation may take place inside the medium. As a first approximation, the problem is solved for optically thick systems (differential approximation). These results are subsequently improved by the introduction of a number of geometrical parameters to yield good accuracy for all optical thicknesses. As examples, two cases are discussed in detail: (1) uniform heat generation in a black enclosure, and (2) an enclosure with one gray surface at constant temperature. Comparison with some numerical solutions generated by Hottel's /Hottel and Cohen (1958) and Einstein (1963)/ zonal method shows excellent agreement.

Modest, M. F.↗

Tissue stimulator enclosure welding fixture

It was demonstrated that the thickness of the stimulator titanium enclosure is directly related to the battery recharge time cycle. Reduction of the titanium enclosure thickness from approximately 0.37 mm (0.015 inch) to 0.05 mm (0.002 inch) significantly reduced the recharge time cycle and thereby patient inconvenience. However, fabrication of titanium enclosures from the thinner material introduced problems in forming, holding, and welding that required improvement in state of the art shop practices. The procedures that were utilized to resolve these fabrication problems are described.

Mcclure, S. R.↗

Experimental determination of the particle motions associated with the low order acoustic modes in enclosures

A procedure for experimentally determining, in terms of the particle motions, the shapes of the low order acoustic modes in enclosures is described. The procedure is based on finding differentiable functions which approximate the shape functions of the low order acoustic modes when these modes are defined in terms of the acoustic pressure. The differentiable approximating functions are formed from polynomials which are fitted by a least squares procedure to experimentally determined values which define the shapes of the low order acoustic modes in terms of the acoustic pressure. These experimentally determined values are found by a conventional technique in which the transfer functions, which relate the acoustic pressures at an array of points in the enclosure to the volume velocity of a fixed point source, are measured. The gradient of the function which approximates the shape of a particular mode in terms of the acoustic pressure is evaluated to give the mode shape in terms of the particle motion. The procedure was tested by using it to experimentally determine the shapes of the low order acoustic modes in a small rectangular enclosure.

Byrne, K. P.↗

Analytical study of acoustic response of a semireverberant enclosure with application to active noise control

The acoustic response of a semireverberant enclosure with two interacting, velocity-prescribed source distributions was analyzed using standard modal analysis techniques with a view toward a better understanding of active noise control. Different source and enclosure dimensions, source separations, and single-wall admittances were studied over representative frequency bandwidths of 10 Hz with source relative phase as a parameter. Results indicate that power radiated into the enclosure agree qualitatively with the spatial average of the mean square pressure, even though the reverberant field is nondiffuse. Decreases in acoustic power can therefore be used to estimate global noise reduction in a nondiffuse semireverberant environment. As might be expected, parametric studies indicate that maximum power reductions of up to 25 dB can be achieved when secondary and primary sources are compact and closely spaced. Although less success is achieved with increasing frequency and source separation or size, significant suppression of up to 8 dB still occurs over the 1 to 2 Hz bandwidth.

Parrott, T. L.↗

Thermal enclosures for electronically scanned pressure modules operating in cryogenic environments

Specific guidelines to design, construct, and test ESP thermal enclosures for applications at cryogenic temperatures are given. The enclosures maintain the ESP modules at a constant temperature (10 C plus or minus 1 C) to minimize thermal zero and sensitivity shifts, to minimize the frequency of expensive on-line calibrations, and to avoid adverse effects on tunnel and model boundary layers. The enclosures are constructed of a rigid closed-cell foam and are capable of withstanding the stagnation pressures to 932kPa (135 psia) without reduction in thermal insulation properties. This construction procedure has been used to construct several thermal packages which have been successfully used in National Transonic Facility.

Mitchell, Michael↗

Numerical studies of convective heat transfer in an inclined semiannular enclosure

Natural convection heat transfer in a two-dimensional differentially heated semiannular enclosure is studied. The enclosure is isothermally heated and cooled at the inner and outer walls, respectively. A commercial software based on the SIMPLER algorithm was used to simulate the velocity and temperature profiles. Various parameters that affect the momentum and heat transfer processes were examined. These parameters include the Rayleigh number, Prandtl number, radius ratio, and the angle of inclination. A flow regime extending from conduction-dominated to convection-dominated flow was examined. The computed results of heat transfer are presented as a function of flow parameter and geometric factors. It is found that the heat transfer rate attains a minimum when the enclosure is tilted about +50 deg with respect to the gravitational direction.

Wang, Lin-Wen↗

Numerical studies of convective heat transfer in an inclined semi-annular enclosure

Natural convection heat transfer in a two-dimensional differentially heated semiannular enclosure is studied. The enclosure is isothermally heated and cooled at the inner and outer walls, respectively. A commercial software based on the SIMPLER algorithm was used to simulate the velocity and temperature profiles. Various parameters that affect the momentum and heat transfer processes were examined. These parameters include the Rayleigh number, Prandtl number, radius ratio, and the angle of inclination. A flow regime extending from conduction-dominated to convection-dominated flow was examined. The computed results of heat transfer are presented as a function of flow parameter and geometric factors. It is found that the heat transfer rate attains a minimum when the enclosure is tilted about +50 deg with respect to the gravitational direction.

Wang, L.-W.↗

Application of static and dynamic enclosures in determining DMS and OCS fluxes in Sphagnum peatlands

A static enclosure method was applied to determine the exchange of dimethyl sulfide (DMS) and OCS between the surface of Sphagnum peatlands and the atmosphere. Measurements were performed concurrently with dynamic enclosure measurements with S-free air used as sweep gas. DMS emission rates determined by both methods were comparable between 5 and 500 nmol/m(sup -2)h(sup -1). The dynamic method provided positive OCS flux rates (emission) for measurements performed at sites containing Sphagnum. Conversely, data from the static method indicated that OCS was consumed from the atmosphere. Measurements using both techniques at a site devoid of vegetation showed that peat is a source of both DMS and OCS. Results suggested that OCS is produced in surface peat but it is taken up from the atmosphere by Sphagnum mosses. However, the net effect of both processes is that OCS uptake exceeds emission. The dynamic enclosure technique is adequate to measure rates of emissions of S gases which are produced in peatlands but not consumed, as long as attention is paid to the rate of sweep flow.

Demello, William Zamboni↗

Uncertainty analysis of diffuse-gray radiation enclosure problems: A hypersensitive case study

An uncertainty analysis of diffuse-gray enclosure problems is presented. The genesis was a diffuse-gray enclosure problem which proved to be hypersensitive to the specification of view factors. This genesis is discussed in some detail. The uncertainty analysis is presented for the general diffuse-gray enclosure problem and applied to the hypersensitive case study. It was found that the hypersensitivity could be greatly reduced by enforcing both closure and reciprocity for the view factors. The effects of uncertainties in the surface emissivities and temperatures are also investigated.

Taylor, Robert P.↗

On the Maximum Expected Electric Field in Electrically Small, Undermoded Enclosures

This paper reports the experimental validation of an improved statistical model for the prediction of maximum expected electric field in electrically small and under-moded enclosures. The aerospace community is interested in application of Hill's statistical models to design of avionics boxes for shielding effectiveness and for tailoring EMC test requirements for critical applications. However, it is observed that the probability distribution for mean-squared electric field in an electrically small enclosure differs from the exponential distribution which is widely used in reverberation chamber testing. It is postulated here that the difference is attributable to the under-moded character of the small enclosure.

Bremner, Paul↗

An Approach to Solving Enclosure Radiation Problems in A Multi-Physics Context

Thermal protection system analysis of complex features or damage sites can sometimes require modeling of high temperature enclosures. Implementing efficient and accurate view-factor algorithms required to model such problems is complex. The current work leverages the Non-equilibrium Radiation (NERO) software, which solves the radiation transport equation in a finite-volume scheme, to alleviating challenges often faced with view-factor calculations. By assuming heat transfer occurs only between grey bodies and that the medium is non-participating, computational cost of the method is significantly reduced. The enclosure physics are modeled through emitting and reflecting boundary conditions in NERO. The emitted radiative flux is dependent on the wall temperature which is a solution to the material response, obtained from Icarus, in this context. The Ares framework manages the time-advancement and exchange of the necessary data between the solvers. The surface energy balance is modified to account for the enclosure terms within the material response boundary condition. The methodology was verified against analytical solutions including radiating parallel plates, a hollow cylinder (shown in Fig. 1), and a hemisphere. Application of the methodology to inform the design of components of the Dragonfly system will be shown.

Ablation↗

Titanium Wire Arc Additive Manufacturing Inert Enclosure and Material Handling Safety Considerations

Wire arc additive manufacturing (WAAM) via metal inert gas (MIG)/gas metal arc welding (GMAW) is a viable option for fabrication of large-scale titanium parts; however, it introduces new safety hazards associated with both the material and the additional system hardware required for the process. Localized gas shielding of the weld arc via standard GMAW torch is inadequate for titanium due to its affinity for oxygen; thereby requiring the use of an inert enclosure to protect the weld from entraining oxygen. The use of the inert enclosure presents potential safety hazards such as operator asphyxiation and brings up discussion of confined space considerations. In addition, the titanium welding process creates pyrophoric titanium soot residue around the deposit, which can undergo deflagration during part cleaning and part removal. This paper provides an overview of the titanium WAAM process along with safety considerations for the design and operation of the inert enclosure as well as functional solutions for the safe handling of the titanium soot by-product.

Walters, Alex↗

Report on High Energy Arcing Fault Experiments: Experimental Results from Open Box Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena. The experiments focus on providing data to better characterize the arc to improve the prediction of arc energy emitted during a HEAF event. An open box experiment allow for direct observation of the arc, which allows diagnostic instrumentation to record the phenomenological data needed for better characterization of the arc energy source term. The data collected supports characterization of the arc and arc jet, enclosure breach, material loss, and electrical properties. These results will be used to better characterizing the hazard for improvements in fire probabilistic risk assessment (PRA) realism. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA Labs. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 22, 2020 and September 18, 2020 on near-identical 51 cm (20 in) cube metal boxes suspended from a Unistrut support structure. The three-phase arcing fault was initiated at the ends of the conductors oriented vertically and located at the center of the box. Either aluminum or copper conductors were used for the conductors. The low-voltage experiments used 1 000 volts AC, while the medium-voltage experiments used 6 900 volts AC consistent with other recently completed experiments. Durations of the experiment ranged from 1 s to 5 s with fault currents ranging from 1 kA to 30 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. The experiments were documented with normal and high-speed videography, infrared imaging and photography.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hydrogen Equipment Enclosure Risk Reduction through Earlier Detection of Component Failures

Hydrogen component reliability and the hazard associated with failure rates is a critical area of research for the successful implementation and growth of hydrogen technology across the globe. The research team has partnered to quantify system risk reduction through earlier detection of hydrogen component failures. A model of hydrogen dispersion in a hydrogen equipment enclosure has been developed utilizing experimentally quantified hydrogen component leak rates as inputs. This model provides insight into the impact of hydrogen safety sensors and ventilation on the flammable mass within a hydrogen equipment enclosure. This model also demonstrates the change in safety sensor response time due to detector placement under various leak scenarios. The team looks to improve overall hydrogen system safety through an improved understanding of hydrogen component reliability and risk mitigation methods. This collaboration fits under the work program of IEA Hydrogen Task 43 Subtask E Hydrogen System Safety.

CFD↗

Examination of entrainment, combustibility, and heat transfer due to cell venting inside simplified battery energy storage enclosures

Battery energy storage systems (ESS) assembled of modules containing lithium-ion batteries can pose fire and explosion hazards during thermal runaway because vented gases may accumulate, combust, or escape enclosures. Here, we propose a prototypical configuration composed of the main components of an ESS rack, where modules are represented as rectangles within an enclosure and vent gas is injected steadily through the top of a module. This idealized geometry allows for exploration of how rack-level characteristics can influence smaller single-cell or module-level scales. Through this geometry, we conduct numerical simulations to understand how variations in the vent velocity, temperature, and vertical location affect entrainment rates, fraction of uncombusted fuel, rich-gas coverage, and heat flux to other modules. At lower vent velocities and vertical positions, buoyancy drives enough entrainment and mixing to react with most of the vent gases on the converging plenum. As jet momentum increases and/or buoyancy decreases via higher vent position in the rack, vent gases can propagate into and burn in the divergence plenum. Heat flux to the impinged module scales strongly with vent momentum and temperature, while heat transfer to upper modules peaks when flames in the diverging plenum reach the surface and declines when combustion is suppressed.

Computational fluid dynamics↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

This report, Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities , explores ways to automatically identify residential homes with enclosure retrofit opportunities; estimate prospective savings; and perform evaluation, measurement, and verification using interval data from communicating thermostats.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enclosure fire modeling

A fire characterization methodology is presented, which for the first time provides a unified analysis framework for the integration of all fire tests data on a common basis. Fire temperatures, smoke densities, toxic gas concentrations and heat fluxes to material properties, enclosure geometry, and ventilation factors are provided in this fire characterization approach. The fire characterization methodology was used to develop an enclosure fire hazards analysis procedure capable of predicting the probable course in fire prevention.

Coulbert, C. D.↗