Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electronics Inspection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Endurance Testing and Fabrication of Advanced 15-cm and 30-cm Carbon-Carbon Composite Grids

Two sets of carbon-carbon grids in a three-grid SAND configuration were endurance tested for 700 hours. Pre- and post test inspections employing electron microscope scans, x-ray fluorescence, grid mass loss measurements, and measurements of grid aperture diameters and thicknesses revealed an extraordinary low degree of erosion. No reduction in grid thicknesses was detectable within the margin of error of the measurements.

Carbon-Carbon↗

Evaluating the Viability of Compact and Portable X-Ray Systems for an Exploration Medical System in a Ground Demonstration

MOTIVATION FOR INCLUDING X-RAY CAPABILITIES For upcoming exploration missions, the need for enhanced medical care becomes critical due to extended mission durations, significant communication delays, and minimal evacuation opportunities. Previous evidence by our team has revealed that among the 119 medical conditions targeted for management during spaceflight within NASA Exploration Medical Capability’s IMPACT Condition List, at least 36 could benefit from radiography (XR). Utilizing XR for diagnosis and management is hypothesized to significantly improve management of crew health by enabling the immediate evaluation and confirmation of potential injuries or illnesses. Beyond clinical applications, XR also holds potential for non-destructive testing (NDT). This includes applications such as assessing the structural integrity of the spacecraft, analyzing surface and meteorite samples, and inspecting onboard electronics. THREE CANDIDATE X-RAY SYSTEMS CHOSEN FOR GROUND DEMONSTRATION The Exploration Medical Capability Element (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) of the Mars Campaign Office initiated early background work for ground demonstrations. In FY21, ExMC published a Concept of Operations to guide requirements development. By FY23, XMIPT and yet2, a technology scouting and open innovation consulting firm, had completed a market survey and trade study to identify potential miniature XR systems. Selection criteria included commercial-off-the-shelf availability, low mass and volume, and regulatory compliance. The top three candidate devices—Remedi REMEX-KA6, MinXray Impact, and FujiFilm Xair—were acquired to characterize the requirements and capabilities of each device. To facilitate testing, phantoms, and radiographic personal protective equipment (PPE) were purchased, and a dedicated space was designated for XRS usage at Glenn Research Center. During this presentation, the mass, volume, and power requirements for each of the three piloted devices are revealed, as well as information regarding the detector, mA, and kV of the devices. GOAL AND OBJECTIVES OF A MINI XRS GROUND DEMONSTRATION The primary goal of ExMC/XMIPT technology demonstrations is to bridge the gap in available, flight-ready medical device technology by flight-testing diagnostic and treatment technologies essential for managing medical conditions during exploration missions. These technologies must adhere to vehicle constraints such as mass, volume, power, and data requirements, integrate seamlessly with medical decision-support tools, and support increasingly Earth-independent operations. There are three main objectives for the future ground demonstration of these three devices. First, we aim to determine the full capabilities of these three miniature XR systems within the context of the spaceflight environment. While medical applications are the primary focus for the miniature XR, a comprehensive exploration of non-medical uses has been initiated by an XMIPT-sponsored NASA SPARK campaign to identify collaborators. Second, we plan to establish criteria and to use insights gained from evaluating each miniature XR against those criteria to select the most suitable system among the three candidates. Third, we intend to evaluate their suitability for flight certification, which includes assessing its durability for launch, reentry, and exposure to high background radiation, as well as its compatibility with existing data architecture systems. Numerous subject matter experts from NASA and partner institutions will support these objectives.

C A Haddix↗

Methods for estimating X-ray machine output through measurement and simulation

We report ball grid arrays are increasingly being applied in the electronics industry and may require X-ray inspection to ensure the integrity and correct placement of solder pins. However, as the architecture of integrated circuits continues to narrow while simultaneously growing more complex, the risk of electronic failure due to radiation damage increases. While medical X-ray devices have been held to high standards and are repeatedly shown to be well characterized, devices used for electronic inspection are often lacking detailed characterization. This study presents unique methods to solve for important properties in X-ray inspection devices such as source to object distance and energy spectrum. This information can then be applied to Monte Carlo models to achieve better overall dose estimates to electronics, which will lead to superior manufactured products. Since X-ray devices can vary greatly in source characteristics, this work investigates spectral measurement and Monte Carlo representation of three X-ray devices. For a Philips SRO 33 100 medical diagnostic device, the spectral output followed expected trends given by the prediction software SpekCalc and Spektr. For the Dage XD7500NT, direct measurement showed a spectral artifact that through the use of Gafchromic films, was shown to be a contributing effect in the dose output. For the Rad Source RS1800, a high powered irradiation device, direct spectral measurement was not achieved. However, a Monte Carlo model using an assumed spectra was found to match ion chamber measurements to a high degree.

47 OTHER INSTRUMENTATION↗

Experiment S026: Ion wake measurement

Measurements of the ion-wake and electron-wake structure and other perturbations of the ambient medium produced by the Gemini spacecraft in orbit are reported. Thruster firings in the TDA-south configuration produced a decrease in the observed ion flux to the outboard ion sensor, an apparent increase in the ion flux to the inboard ion sensor, and an enhanced electron concentration to the outboard electron sensor. Visual inspection of strip-chart data was indicative that definitive wake-cone angles could be determined. It also was apparent for many cases that the electron distribution followed the ion depletion effects; this was indicative that the wake was a plasma, not an ion wake. Analysis of the data from the GATV orbits was indicative that electron and ion temperatures were higher than was estimated. The high electron temperature accounted for the sensor saturation observed during the mission. This temperature measurement was 0.3 electron volt at a 200-n. mi. altitude during daytime conditions. Spacecraft wake structure has been observed as far as 100 feet from the vehicle.

Medved, D. B.↗

Ultrasonic Inspection Of Welds On Tube Fittings

Scanning ultrasonic apparatus designed for use in nondestructive inspection of electron-beam welds between heat-exchanger tube and end fittings. Includes ultrasonic probe, scanning mechanism, ultrasonic-signal-generating and -processing circuits, and computers. Not necessary to immerse any part of apparatus or tube/fitting assembly in water during inspection. Output ultrasonic-test signals displayed on computer to reveal defects.

Ray, Arjun N.↗

Scanning electron microscope/energy dispersive x ray analysis of impact residues on LDEF tray clamps

To better understand the nature of particulates in low-Earth orbit (LEO), and their effects on spacecraft hardware, we are analyzing residues found in impacts on the Long Duration Exposure Facility (LDEF) tray clamps. LDEF experiment trays were held in place by 6 to 8 chromic-anodized aluminum (6061-T6) clamps that were fastened to the spacecraft frame using three stainless steel hex bolts. Each clamp exposed an area of approximately 58 sq cm (4.8 cm x 12.7 cm x .45 cm, minus the bolt coverage). Some 337 out of 774 LDEF tray clamps were archived at JSC and are available through the Meteoroid & Debris Special Investigation Group (M&D SIG). Optical scanning of clamps, starting with Bay/Row A01 and working toward H25, is being conducted at JSC to locate and document impacts as small as 40 microns. These impacts are then inspected by Scanning Electron Microscopy/Energy Dispersive X-ray Analysis (SEM/EDXA) to select those features which contain appreciable impact residue material. Based upon the composition of projectile remnants, and using criteria developed at JSC, we have made a preliminary discrimination between micrometeoroid and space debris residue-containing impact features. Presently, 13 impacts containing significant amounts of unmelted and semi-melted micrometeoritic residues were forwarded to Centre National d'Etudes Spatiales (CNES) in France. At the CNES facilities, the upgraded impacts were analyzed using a JEOL T330A SEM equipped with a NORAN Instruments, Voyager X-ray Analyzer. All residues were quantitatively characterized by composition (including oxygen and carbon) to help understand interplanetary dust as possibly being derived from comets and asteroids.

Bernhard, Ronald P.↗

INSERVICE INSPECTION OF EXTENDED DRY STORAGE OF SPENT NUCLEAR FUEL, PART II: NDE/SENSOR TECHNOLOGY DEVELOPMENT AND CODIFICATION

This paper describes development and demonstration of nondestructive examination (NDE) technologies to support periodic examinations of interim dry cask storage system (DCSS) canisters for spent nuclear fuel in the USA to verify continued safe operation and that the canister confinement is intact and performing its intended safety function. Specifically, this work relates to NDE technology development for “canister” based DCSS systems which form the majority population of DCSSs, in the USA, for interim storage of spent nuclear fuel. Consideration of potential degradation of the welded stainless-steel canister in these systems is required for continued usage in the period of extended operation (PEO) beyond the initial license or certified term. Physical access to the canister surface is constrained due to narrow annulus spaces between the canister and the overpack, tortuous entry pathways, and high temperatures and radiation doses that can be damaging to materials and electronics related to inspections. Several activities to demonstrate NDE technologies for the inspections of different DCSS systems are summarized.

nondestructive examination (NDE), Dry Cask Storage↗

SIMS analysis of extended impact features on LDEF experiment

Discussed here are the first Secondary Ion Mass Spectroscopy (SIMS) analysis of projectile material deposited in extended impact features on Ge wafers from the trailing edge. Although most capture cells lost their plastic film covers, they contain extended impact features that apparently were produced by high velocity impacts when the plastic foils were still intact. Detailed optical scanning of all bare capture cells from the trailing edge revealed more than 100 impacts. Fifty-eight were selected by scanning electron microscope (SEM) inspection as prime candidates for SIMS analysis. Preliminary SIMS measurements were made on 15 impacts. More than half showed substantial enhancements of Mg, Al, Si, Ca, and Fe in the impact region, indicating micrometeorites as the projectiles.

Amari, S.↗

Innovation: Key to the future

The NASA Marshall Space Flight Center Annual Report is presented. A description of research and development projects is included. Topics covered include: space science; space systems; transportation systems; astronomy and astrophysics; earth sciences; solar terrestrial physics; microgravity science; diagnostic and inspection system; information, electronic, and optical systems; materials and manufacturing; propulsion; and structures and dynamics.

Source record↗

Atomic oxygen interactions with protected organic materials on the Long Duration Exposure Facility (LDEF)

The Long Duration Exposure Facility (LDEF) has provided an excellent opportunity to understand the nature of directed atomic oxygen interactions with protected polymers and composites. Although there were relatively few samples of materials with protective coatings on their external surfaces on LDEF which were exposed to a high atomic oxygen fluence, analysis of such samples has enabled an examination of the shape of atomic oxygen undercut cavities at defect sites in the protective coatings. Samples of front-surface aluminized (Kapton) polyimide were inspected by scanning electron microscopy to identify and measure crack defects in the aluminum protective coatings. After chemical removal of the aluminum coating, measurements were also made of the width of the oxidized undercut cavities below the crack defects. The LDEF flight undercut cavity geometries were then compared with Monte Carlo computational model undercut cavity predictions. The comparison of the LDEF results and computational modeling indicates agreement in specific undercut cavity geometries for atomic oxygen reaction probabilities dependent upon the 0.68 to 3.0 power of the energy. However, no single energy dependency was adequate to replicate flight results over a variety of aluminum crack widths.

Banks, Bruce A.↗

Inspection system of wellbores and surrounding rock using penetrating X-rays

A system, method, and apparatus for wellbore inspection comprise an electron accelerator to generate X-rays, a rotating collimator assembly configured to produce a cone of X-rays, and at least one detector assembly configured to collect backscattered X-rays. A position assembly can be provided to move the electron accelerator, rotating collimator assembly, and detector through a wellbore. A computer system is configured to receive data from the detector and generate an image of the wellbore.

Kroc, Thomas K.↗

Radiopaque particle processing additive

A radiopaque processing medium comprising a plurality of radiopaque particles and a non-radiopaque processing medium. The plurality of radiopaque particles is added to the non-radiopaque processing medium to increase a bulk density of the processing medium thereby forming the radiopaque processing medium. The radiopaque processing medium allows excess process media to be located and characterized during X-ray inspection of an electronic device on which the radiopaque processing medium was used. The radiopaque processing medium may also be used to locate and identify flaws/defects of the electronic device based on the location of excess radiopaque processing medium. The radiopaque processing medium may also be used as an underfill material to reinforce electronic chips soldered to the electronic device.

Diamond, Louis↗

Comparisons of NDT Methods to Inspect Cork and Cork filled Epoxy Bands

Sheet cork and cork filled epoxy provide external insulation for the Reusable Solid Rocket Motor (RSRM) on the Nation's Space Transportation System (STS). Interest in the reliability of the external insulation bonds has increased since the Columbia incident. A non-destructive test (NDT) method that will provide the best inspection for these bonds has been under evaluation. Electronic Shearography has been selected as the primary NDT method for inspection of these bond lines in the RSRM production flow. ATK Launch Systems Group has purchased an electronic shearography system that includes a vacuum chamber that is used for evaluation of test parts and custom vacuum windows for inspection of full-scale motors. Although the electronic shearography technology has been selected as the primary method for inspection of the external bonds, other technologies that exist continue to be investigated. The NASA/Marshall Space Flight Center (MSFC) NDT department has inspected several samples for comparison with electronic shearography with various inspections systems in their laboratory. The systems that were evaluated are X-ray backscatter, terahertz imaging, and microwave imaging. The samples tested have some programmed flaws as well as some flaws that occurred naturally during the sample making process. These samples provide sufficient flaw variation for the evaluation of the different inspection systems. This paper will describe and compare the basic functionality, test method and test results including dissection for each inspection technology.

Lingbloom, Mike↗

Methods of Measurement for Semiconductor Materials, Process Control, and Devices

The development of methods of measurement for semiconductor materials, process control, and devices is reported. Significant accomplishments include: (1) Completion of an initial identification of the more important problems in process control for integrated circuit fabrication and assembly; (2) preparations for making silicon bulk resistivity wafer standards available to the industry; and (3) establishment of the relationship between carrier mobility and impurity density in silicon. Work is continuing on measurement of resistivity of semiconductor crystals; characterization of generation-recombination-trapping centers, including gold, in silicon; evaluation of wire bonds and die attachment; study of scanning electron microscopy for wafer inspection and test; measurement of thermal properties of semiconductor devices; determination of S-parameters and delay time in junction devices; and characterization of noise and conversion loss of microwave detector diodes.

Bullis, W. M.↗

Experimental and analytical study of fatigue damage in notched graphite/epoxy laminates

Both tension and compression fatigue behaviors were investigated in four notched graphite/epoxy laminates. After fatigue loading, specimens were examined for damage type and location using visual inspection, light microscopy, scanning electron microscopy, ultrasonic C-scans, and X-radiography. Delamination and ply cracking were found to be the dominant types of fatigue damage. In general, ply cracks did not propagate into adjacent plies of differing fiber orientation. To help understand the varied fatigue observations, the interlaminar stress distribution was calculated with finite element analysis for the regions around the hole and along the straight free edge. Comparison of observed delamination locations with the calculated stresses indicated that both interlaminar shear and peel stresses must be considered when predicting delamination. The effects of the fatigue cycling on residual strength and stiffness were measured for some specimens of each laminate type. Fatigue loading generally caused only small stiffness losses. In all cases, residual strengths were greater than or equal to the virgin strengths.

Whitcomb, J. D.↗

Automatic Inspection During Machining

In experimental manufacturing process, numerically-controlled machine tool temporarily converts into inspection machine by installing electronic touch probes and specially-developed numerical-control software. Software drives probes in paths to and on newly machined parts and collects data on dimensions of parts.

Ransom, Clyde L.↗

Training Data Optimized and Conditioned to Learn Characteristic Patterns of Vibrating Blisks and Fan Blades

At the NASA Glenn Research Center, we have been training artificial neural networks to interpret the characteristic patterns (see the leftmost image) generated from electronic holograms of vibrating structures. These patterns not only visualize the vibration properties of structures, but small changes in the patterns can indicate structural changes, cracking, or damage. Neural networks detect these small changes well. Our objective has been to adapt the neural-network, electronic-holography combination for inspecting components in Glenn's Spin Rig.

Decker, Arthur J.↗