Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electronics Inspection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electronic Inspection of Beef

Two proposed methods for grading beef quality based on inspection by electronic equipment: one method uses television camera to generate image of a cut of beef as customer sees it; other uses ultrasonics to inspect live animal or unsliced carcasses. Both methods show promise for automated meat inspection.

Anselmo, Victor J.↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods.This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel. An ultrasonic scanner was enclosed in a nitrogen-cooled insulating box that prevented thermal damage from the industrial oven to the temperature-sensitive electronics. Inspection of the composite part was performed through the bottom of the enclosure, which served as the tool plate for the part. In this study, a porosity gradient was introduced through a misfit of the part and caul plate. Using the data obtained from B-scans and amplitude C-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

In-process, Defect Detection, Cure Monitoring, Por↗

Physics-assisted generative adversarial network for X-ray tomography

X-ray tomography is capable of imaging the interior of objects in three dimensions non-invasively, with applications in biomedical imaging, materials science, electronic inspection, and other fields. The reconstruction process can be an ill-conditioned inverse problem, requiring regularization to obtain satisfactory results. Recently, deep learning has been adopted for tomographic reconstruction. Unlike iterative algorithms which require a distribution that is known a priori , deep reconstruction networks can learn a prior distribution through sampling the training distributions. In this work, we develop a Physics-assisted Generative Adversarial Network (PGAN), a two-step algorithm for tomographic reconstruction. In contrast to previous efforts, our PGAN utilizes maximum-likelihood estimates derived from the measurements to regularize the reconstruction with both known physics and the learned prior. Compared with methods with less physics assisting in training, PGAN can reduce the photon requirement with limited projection angles to achieve a given error rate. The advantages of using a physics-assisted learned prior in X-ray tomography may further enable low-photon nanoscale imaging.

47 OTHER INSTRUMENTATION↗

Investigation of thermal fatigue in fiber composite materials

Graphite-epoxy laminates were thermally cycled to determine the effects of thermal cycles on tensile properties and thermal expansion coefficients of the laminates. Three 12-ply laminate configurations were subjected to up to 5,000 thermal cycles. The cumulative effect of the thermal cycles was determined by destructive inspection (electron micrographs and tensile tests) of samples after progressively larger numbers of cycles. After thermal cycling, the materials' tensile strengths, moduli, and thermal expansion coefficients were significantly lower than for the materials as fabricated. Most of the degradation of properties occurred after only a few cycles. The property degradation was attributed primarily to the progressive development of matrix cracks whose locations depended upon the layup orientation of the laminate.

Fahmy, A. A.↗

Querying Proofs (Work in Progress)

We motivate and introduce the basis for a query language designed for inspecting electronic representations of proofs. We argue that there is much to learn from large proofs beyond their validity, and that a dedicated query language can provide a principled way of implementing a family of useful operations.

Aspinall, David↗

Radiographic inspection specifications for electronic components

Quality assurance provisions cover personnel training, radiographic equipment, radiographic test procedures, and inspection and examination of radiographs. Supplementary information includes accept and reject criteria for radiographic inspection of resistors, capacitors, transistors, hybrid microcircuits, diodes, small coils and transformers.

Source record↗

New camera tube improves ultrasonic inspection system

Electron multiplier, incorporated into the camera tube of an ultrasonic imaging system, improves resolution, effectively shields low level circuits, and provides a high level signal input to the television camera. It is effective for inspection of metallic materials for bonds, voids, and homogeneity.

Berger, H.↗

Voice-Recognition System Records Inspection Data

Main Injector Voice Activated Record (MIVAR) system acts on vocal commands and processes spoken inspection data into electronic and printed inspection reports. Devised to improve acquisition and recording of data from borescope inspections of interiors of liquid-oxygen-injecting tubes on main engine of Space Shuttle. With modifications, system used in other situations to relieve inspectors of manual recording of data. Enhances flow of work and quality of data acquired by enabling inspector to remain visually focused on workpiece.

Rochester, Larry L.↗

Using Optically Stimulated Electron Emission as an Inspection Method to Monitor Surface Contamination

During redesign of the Space Shuttle reusable solid rocket motor (RSRM), NASA amended the contract with ATK Launch Systems (then Morton Thiokol Inc.) with Change Order 966 to implement a contamination control and cleanliness verification method. The change order required: (1) A quantitative inspection method (2) A written record of actual contamination levels versus a known reject level (3) A method that is more sensitive than existing methods of visual and black light inspection. Black light inspection is only useful for inspection of contaminants that fluoresce near the 365 nm spectral line and is not useful for inspection of most silicones that will not produce strong fluorescence. Black light inspection conducted by a qualified inspector under controlled light is capable of detecting Conoco HD-2 grease in gross amounts and is very subjective due to operator sensitivity. Optically stimulated electron emission (OSEE), developed at the Materials and Process Laboratory at Marshall Space Flight Center (MSFC), was selected to satisfy Change Order 966. OSEE offers several important advantages over existing laboratory methods with similar sensitivity, e.g., spectroscopy and nonvolatile residue sampling, which provide turn around time, real time capability, and full coverage inspection capability. Laboratory methods require sample gathering and in-lab analysis, which sometimes takes several days to get results. This is not practical in a production environment. In addition, these methods do not offer full coverage inspection of the large components

Lingbloom, Mike S.↗

Neural-net Processed Electronic Holography for Rotating Machines

This report presents the results of an R&D effort to apply neural-net processed electronic holography to NDE of rotors. Electronic holography was used to generate characteristic patterns or mode shapes of vibrating rotors and rotor components. Artificial neural networks were trained to identify damage-induced changes in the characteristic patterns. The development and optimization of a neural-net training method were the most significant contributions of this work, and the training method and its optimization are discussed in detail. A second positive result was the assembly and testing of a fiber-optic holocamera. A major disappointment was the inadequacy of the high-speed-holography hardware selected for this effort, but the use of scaled holograms to match the low effective resolution of an image intensifier was one interesting attempt to compensate. This report also discusses in some detail the physics and environmental requirements for rotor electronic holography. The major conclusions were that neural-net and electronic-holography inspections of stationary components in the laboratory and the field are quite practical and worthy of continuing development, but that electronic holography of moving rotors is still an expensive high-risk endeavor.

Decker, Arthur J.↗

Electron and Electron-Nuclear Dynamics of Open Quantum Subsystems

Leveraging an open-subsystem formulation of Density Functional Theory (DFT) we aim at describing periodic and molecular systems alike, including their electronic and nuclear dynamics. Subsystem DFT enables first principles simulations to approach realistic time- and length-scales, and most importantly sheds light on the dynamical behavior of complex systems. Taking subsystem DFT to the time domain allows us to inspect the electron dynamics of condensed-phase systems in real time. In liquids and interfaces, we observe all the relevant regimes proper of non-Markovian open quantum system dynamics, such as electronic energy transfer, and screening. In addition, the ab-initio modeling of system-bath interactions brought us to observe and justify the holographic time-dependent electron density theorem. Contrary to interactions between molecular (finite) systems, when molecules interact with metal or semiconductor surfaces the electron dynamics is strongly non-Markovian with dramatic repercussions to the molecule’s response to external perturbations. Metals and semiconductors typically have large polarizabilities, and even in a regime of low coupling their effect on impinging molecular species is significant–line broadening, peak shift, and intensity borrowing are observed, characterized, and explained in terms of inter-subsystem dynamical interactions and a many-body decomposition of the system’s density-density response function in a way that transcends the canons of Fermi Golden Rule.

33 ADVANCED PROPULSION SYSTEMS↗

Optimized Viewing Techniques to Minimize Radiation Damage From X-ray Imaging Systems

X-ray inspection of ball grid arrays (BGAs) is typically performed at one or more viewing angles to examine adhesion sites for errors such as voids, joint cracking, or head-in-pillow. During this inspection process, the cir cuit board assembly is subject to ionizing radiation exposure, which can cause trapped charge within oxide layers of semiconductor devices. Some x-ray machines allow for programmable inspection routines, which could be used to optimize radiation exposure to semiconductor components. Using Monte Carlo methods, x-ray inspection of a BGA was simulated to determine a range of acceptable viewing angles. Dose rates to circuit board components were estimated at each inspection angle to determine the view resulting in optimized radiation exposure. Results showed that for each BGA, the maximum unobstructed viewing times without exceeding a 5 Gy dose limit to a single part ranged from 82 to 94 minutes. Using a radiation cost function method, optimized viewing across all components was found. Here, it was observed that for a consistent dose limit applied to silicon-based components, performing inspection with BGAs facing the x-ray source was optimal. A third method was applied, assigning individual dose limits based on empirical data from the NASA Goddard Space Flight Center radiation database. This method showed that optimized viewing maximizes the distance between the radiation source and highly sensitive components. It was also observed that cumulative effects from viewing two BGAs will influence viewing angles, causing the optimal view of one BGA to exist nearly 180° from the other.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray Inspection Model Validation with Physical Dosimetry

A non-functional printed circuit board assembly was developed using ULTIboard and a simple computational transport model was created for use with the Monte Carlo software MCNP. EBT 3 film radiography was used to compare with Monte Carlo simulation to validate the board representation. The computational transport model was then revised to include connection pins, solder balls, highly attenuating internal structures, and copper trace distribution. Results from the revised model were compared to the EBT 3 films to observe improvements to dose profiles. It was found that this method was useful in verifying the placement of components, as the dose profiles were observed to follow the same trends. The experiment was then repeated using XRQA 2 films to achieve the same level of contrast with 1% the dose of EBT 3 films. It was found that high contrast may be achieved using these films to identify major issues with the model geometry, at a cost of dose profile accuracy. A second validation method was applied to the model using 37 CaF 2 thermoluminescent dosimeters (TLDs). TLD measurements were compared with the simplified and complex transport models to identify the features that have the greatest impact on simulation accuracy. The TLD calibration to CaF 2 was found to be accurate within 5.6%, while calibration to dose in Si was found to be accurate within 4.7%. Finally, it was observed that the accurate representation of solder balls and proper modeling of highly attenuating internal structures had the greatest impact on simulation accuracy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Standardized Methods for Electronic Shearography

Research was conducted in development of operating procedures and standard methods to evaluate fiber reinforced composite materials, bonded or sprayed insulation, coatings, and laminated structures with MSFC electronic shearography systems. Optimal operating procedures were developed for the Pratt and Whitney Electronic Holography/Shearography Inspection System (EH/SIS) operating in shearography mode, as well as the Laser Technology, Inc. (LTI) SC-4000 and Ettemeyer SHS-94 ISTRA shearography systems. Operating practices for exciting the components being inspected were studied, including optimal methods for transient heating with heat lamps and other methods as appropriate to enhance inspection capability.

Lansing, Matthew D.↗

Lightning Reporting at 45th Weather Squadron: Recent Improvements

The 45th Weather Squadron (45 WS) provides daily lightning reports to space launch customers at CCAFS/KSC. These reports are provided to assess the need to inspect the electronics of satellite payloads, space launch vehicles, and ground support equipment for induced current damage from nearby lightning strokes. The 45 WS has made several improvements to the lightning reports during 2008-2009. The 4DLSS, implemented in April 2008, provides all lightning strokes as opposed to just one stroke per flash as done by the previous system. The 45 WS discovered that the peak current was being truncated to the nearest kilo amp in the database used to generate the daily lightning reports, which led to an up to 4% underestimate in the peak current for average lightning. This error was corrected and led to elimination of this underestimate. The 45 WS and their mission partners developed lightning location error ellipses for 99% and 95% location accuracies tailored to each individual stroke and began providing them in the spring of 2009. The new procedure provides the distance from the point of interest to the best location of the stroke (the center of the error ellipse) and the distance to the closest edge of the ellipse. This information is now included in the lightning reports, along with the peak current of the stroke. The initial method of calculating the error ellipses could only be used during normal duty hours, i.e. not during nights, weekends, or holidays. This method was improved later to provide lightning reports in near real-time, 24/7. The calculation of the distance to the closest point on the ellipse was also significantly improved later. Other improvements were also implemented. A new method to calculate the probability of any nearby lightning stroke. being within any radius of any point of interest was developed and is being implemented. This may supersede the use of location error ellipses. The 45 WS is pursuing adding data from nine NLDN sensors into 4DLSS in real-time. This will overcome the problem of 4DLSS missing some of the strong local strokes. This will also improve the location accuracy, reduce the size and eccentricity of the location error ellipses, and reduce the probability of nearby strokes being inside the areas of interest when few of the 4DLSS sensors are used in the stroke solution. This will not reduce 4DLSS performance when most of the 4DLSS sensors are used in the stroke solution. Finally, several possible future improvements were discussed, especially for improving the peak current estimate and the error estimate for peak current, and upgrading the 4DLSS. Some possible approaches for both of these goals were discussed.

Finn, Frank C.↗