Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ECC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 37 records · Page 2

Effects of solution mass transport on the ECC ozonesonde background current

A technique is developed to measure the effective mass transport parameter for the electrochemical concentration cell (ECC) ozonesonde in order to determine the mass transport rate constant for the ECC as a function of pressure. It is shown that a pressure dependent factor in the background current originates in a convective mass transport parameter. It is determined that for atmospheric pressures greater than 100 mb the mass transport parameter is a constant, while at pressures less than 100 mb it decreases logarithmically with pressure. It is suggested that the background current correction is directly correlated to the mass transport parameter pressure dependence. The presently used background current correction, which is based on the partial pressure of oxygen, is found to lead to an overestimation of the integrated ozone value in the troposphere for the ECC ozonesonde data.

Thornton, D. C.↗

Evaluation of longitudinal double-spin asymmetry measurements in semi-inclusive deep-inelastic scattering from the proton for the ECCE detector design

The evaluation of the measurement of double-spin asymmetries for charge-separated pions and kaons produced in deep-inelastic scattering from the proton using the ECCE detector design concept is presented, for the combinations of lepton and hadron beam energies of 5 × 41 GeV 2 and 18 × 275 GeV 2 . The study uses unpolarised simulated data that are processed through a full GEANT simulation of the detector. These data are then reweighted at the parton level with DSSV helicity distributions and DSS fragmentation functions, in order to generate the relevant asymmetries, and subsequently analysed. Furthermore, the performed analysis shows that the ECCE detector concept provides the resolution and acceptance, with a broad coverage in kinematic phase space, needed for a robust extraction of asymmetries. This, in turn, allows for a precise extraction of sea-quark helicity distributions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Detector requirements and simulation results for the EIC exclusive, diffractive and tagging physics program using the ECCE detector concept

This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC’s exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark–gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detector system close to the beamline to ensure exclusivity and tag ion beam/fragments for a particular reaction of interest. Preliminary studies confirm the proposed technology and design satisfy the requirements. Further, the projected physics impact results are based on the projected detector performance from the simulation at 10 or 100 fb -1 of integrated luminosity. Additionally, insights related to a potential second EIC detector are documented, which could serve as a guidepost for future development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scientific computing plan for the ECCE detector at the Electron Ion Collider

The Electron Ion Collider (EIC) is the next generation of precision QCD facility to be built at Brookhaven National Laboratory in conjunction with Thomas Jefferson National Laboratory. There are a significant number of software and computing challenges that need to be overcome at the EIC. During the EIC detector proposal development period, the ECCE consortium began identifying and addressing these challenges in the process of producing a complete detector proposal based upon detailed detector and physics simulations. Here, in this document, the software and computing efforts to produce this proposal are discussed; furthermore, the computing and software model and resources required for the future of ECCE are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECCE unpolarized TMD measurements

For this work, we performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions for the ECCE detector proposal. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS variables x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. The expected statistical precision of such measurements is extrapolated to accumulated luminosities of 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. The expected uncertainties are then used to obtain the expected impact on the related TMD distribution and fragmentation functions. We find that the ECCE detector proposal fulfills the physics requirements on these channels as detailed in the EIC Yellow Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of ECCS Acceptance Criteria and Experimental Basis Evolution Toward Fuel Fragmentation, Relocation, and Dispersal Studies

The U.S. nuclear industry is pursuing extensions of light water reactor (LWR) fuel burnup and enrichment limits to approximately 75 GWd/t and 10 wt.% 235 U to achieve economic and operational benefits. A central safety consideration in this effort is the behavior of high burnup (HBu) fuel during loss-of-coolant accidents (LOCAs), particularly fuel fragmentation, relocation, and dispersal (FFRD). Here, this work provides a historical and technical review of U.S. LOCA regulation and experimentation, clarifying how the evolution of Emergency Core Cooling System (ECCS) acceptance criteria in 10 CFR 50.46 has shaped both testing approaches and interpretations of fuel safety. The study revisits the original intent of the ECCS criteria, showing that the peak cladding temperature and equivalent cladding reacted limits were developed as surrogates to preserve a coolable geometry. The explicit inclusion of the coolable geometry criterion in the regulation was intended to emphasize the underlying safety philosophy and as a safeguard against unforeseen failure modes, an intent that remains directly relevant to modern concerns regarding FFRD. The review traces the lineage of HBu LOCA experiments to the Argonne National Laboratory furnace tests, from which subsequent programs at Studsvik, Halden, and Oak Ridge National Laboratory were derived. These tests employed a 5 °C/s heating rate inherited from early embrittlement studies, a stylized temperature history that does not represent actual LWR LOCA thermal-hydraulics. Comparison of these test conditions to pressurized water reactor large break LOCAs and separate effects data indicates that the existing HBu LOCA database may not be fully applicable to all LWR LOCA scenarios, from which a qualitative framework for applicability is proposed.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance tests on the Kohmyr ECC ozone sonde

The reliability and accuracy of the Kohmyr ECC ozone sonde are determined. Emphasis is placed on establishing and testing for leak-free connections and stable pump flow rates as well as properly adjusting the pumping pressure. Calibration of the Kohmyr ECC ozone sondes and Dasibi monitors is described. Raw ordinate data and ozone connection data are presented in tabular form. The results of a linear regression treatment of the sonde-indicated ozone concentration vs. Dasibi readings for each switch position are included along with averages of the regression parameters over the six sequencing switch positions. It is suggested that sondes and Dasibi monitors be individually calibrated before flight.

Bandy, A. R.↗

The validation of LIMS ozone profiles using correlative rocket, ECC, and Dobson data sets

The Limb Infrared Monitor of the Stratosphere (LIMS) experiment is a limb scanning infrared sounder designed to measure vertical temperature profiles and the concentrations of key chemical compounds which are important in the stratospheric ozone-nitrogen photochemistry. Preliminary ozone profiles are being intercompared with correlative rocket and balloonsonde ozone data sets as part of the Nimbus 7 LIMS data validation activity. The LIMS ozone retrievals extend from the lower mesosphere to the tropopause (or cloud-top altitudes). In this paper, preliminary statistics of comparisons of ECC (electrochemical concentration cell) ozonesonde and rocket ozone profiles with LIMS ozone profiles are presented. ECC ozonesonde data taken at times of LIMS overpasses are also used to extend the LIMS retrieval down to ground level. Each combined profile is then integrated to obtain total column ozone. These integrated results are compared to Dobson data obtained at approximately the same time and location.

Remsberg, E. E.↗

Satellite and correlative measurements of stratospheric ozone - Comparison of measurements made by SAGE, ECC balloons, chemiluminescent, and optical rocketsondes

The validity of ozone-profile data from the satellite sensor SAGE was tested in a series of correlative experiments conducted at five fixed sites between 6 deg S and 65 deg N during 1979-1980. The intercomparisons included data taken with electrochemical ozone (ECC) balloonsondes and chemiluminescent and optical rocketsondes. The average mean difference for 17 separate comparisons between the SAGE and ECC balloonsonde observations over the altitudes 18-28 km was 9.3 percent with a standard deviation of 2.8 percent. Excluding comparisons separated by greater than 500 km reduces the average mean difference to 8.9 percent and the standard deviation to 2.1 percent. The average mean difference between SAGE and three optical rocketsonde observations over the altitudes 25-50 km was 11 percent, and between SAGE and two chemiluminescent rocketsondes over the altitudes 20-60 km it was 13.5 percent. Considering the differences in vertical resolution, experimental errors, and ozone time and space gradients, the agreement between SAGE-derived ozone profiles and these correlative measurements is considered very good. In addition, isopleths of ozone mixing ratio versus latitude and altitude are in good agreement with previously published results.

Mccormick, M. P.↗

Design and simulated performance of calorimetry systems for the ECCE detector at the electron ion collider

Here, we describe the design and performance the calorimeter systems used in the ECCE detector to achieve the overall performance specifications cost-effectively with careful consideration of appropriate technical and schedule risks. The calorimeter systems consist of three electromagnetic calorimeters, covering the combined pseudorapidity range from -3.7 to 3.8 and two hadronic calorimeters covering a combined range of -1.1<η<3.8. Key calorimeter performances which include energy and position resolutions, reconstruction efficiency, and particle identification will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of solution mass transport on the ECC ozonesonde background current

Measurement of the mass transport rate constant for the electrochemical concentration cell in an ozonesonde as a function of the pressure is reported. The investigation was performed to accurately model the residual current present in the ECC cell in the absence of ozone. The convective mass transport for two sondes were determined while maintaining a sufficiently negative cathodic potential to eliminate electron transfer at the cathode surface. A sonde was placed in a bell jar and subjected to varying pressure levels. When the background current was kept below 0.1 microamp and pressure was from 100-1000 mb, the necessary correction term for the pressure was independent of pressure. However, below 100 mb, a logarithmic decrease in the background current with pressure is expected. Present practices, involving a sensitivity to oxygen, are calculated to result in overestimation of the total ozone between 1000-10 mb by 0.0096 atm-cm with a background current of 0.1 microamp at 1000 mb.

Thornton, D. C.↗

The latitudinal distribution of ozone to 35 km altitude from ECC ozonesonde observations, 1982-1990

Electrochemical concentration cell (ECC) ozone-sonde observations, made in recent years at ten stations whose locations range from the Arctic to Antarctica, have yielded a self-consistent ozone data base from which mean seasonal and annual latitudinal ozone vertical distributions to 35 km have been derived. Ozone measurement uncertainties are estimated, and results are presented in the Bass-Paur (1985) ozone absorption coefficient scale adopted for use with Dobson ozone spectrophotometers January 1, 1992. The data should be useful for comparison with model calculations of the global distribution of atmospheric ozone, for serving as apriori statistical information in deriving ozone vertical distributions from satellite and Umkehr observations, and for improving the satellite and Umkehr ozone inversion algorithms. Attention is drawn to similar results based on a less comprehensive data set published in Ozone in the Atmosphere, Proceedings of the 1988 Quadrennial Ozone Symposium where errors in data tabulations occurred for three of the stations due to inadvertent transposition of ozone partial pressure and air temperature values.

Komhyr, W. D.↗

10826-ECC-CA-FY24Q1-BP1Q3

Emerald Cities Collaborative (ECC) is piloting a replicable model to increase the supply and diversity of technicians entering the solar/electrical workforces to meet demand for renewable energy, electrification, and energy efficiency.

14 SOLAR ENERGY↗

Sources of background current in the ECC ozonesonde - Implications for total ozone measurements

The source of the background current in the usual operation of the electrochemical concentration cell ozonesonde is the reduction of tri-iodide normally present in the cathode solution. The time variations in the background current can be explained by the slow rates of solution mass transport and of heterogeneous electron transfer for tri-iodide. Oxygen does not contribute to the background current through reaction with iodide to produce tri-iodide. Direct reduction of oxygen at the cathode is negligible once the electrodes have been exposed to iodide for 24 hours. The present background current correction is altitude-dependent, since it is based on an assumed sensitivity of the electrochemical concentration cell to oxygen. If the background current is independent of altitude and of oxygen, a constant, uncorrected, background current of 0.1 microamp would produce an error of +5.5% for the total ozone value of the electrochemical concentration cell for a typical midlatitude total ozone value of 0.345 atm-cm.

Thornton, D. C.↗