Green and durable engineered cementitious composites (GD-ECC) with recycled PE fiber, desert sand, and carbonation curing: Mixture design, durability performance, and life-cycle analysis
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
The Observatoire de Haute Provence (OHP) weekly Electrochemical Concentration Cell (ECC) ozonesonde data have been homogenized for the period 1991-2021 according to the recommendations of the Ozonesonde Data Quality Assessment (O3S-DQA) panel. The assessment of the ECC homogenization benefit has been carried out using comparisons with other ozone measuring ground based instruments at the same station (lidar, surface measurements) and with collocated satellite observations of the O3vertical profile by Microwave Limb Sounder (MLS). The major differences between uncorrected and5homogenized ECC data are related to a change of ozonesonde type in 1997, removal of the pressure dependency of the ECC background current and correction of internal pump temperature. The original 3-4 ppbv positive bias between ECC and Lidar in the troposphere is corrected with the homogenization. The ECC 30-years trends of the seasonally adjusted ozone concentrations are also significantly improved in both the troposphere and the stratosphere after the ECC homogenization, as shown by the ECC/lidar or ECC/surface ozone trend comparisons. A -0.19% per year negative trend of the normalization factor (NT)10calculated using independent measurements of the total ozone column (TOC) at OHP disappears after homogenization of the ECC data. There is however a remaining -3.7% negative bias in the TOC which is likely related to an underestimate of the ECC concentrations in the stratosphere above 50 hPa. Differences between TOC measured by homogenized ECC and satellite observations show a smaller bias of -1%. Comparisons between homogenized ECC and OHP stratospheric lidar and MLS observations below 26 km are slightly negative (-2%) or positive (+2%), respectively. Both the comparisons with lidar and15satellite observations suggest that homogenization increases the negative bias of the ECC to values lower than -6% above 28km. The reason for this bias is still unclear, but a possible explanation might be related to freezing or evaporation of the sonde solution in the stratosphere.
Use of Engineered Cementitious Composites (ECC) has been proven to enhance structural fatigue resistance and reduce the use-phase emissions for transportation infrastructure. Carbonation curing offers an opportunity to reduce the embodied carbon of ECC via direct CO 2 sequestration. In this study, the impact of carbonation curing on ECC’s fatigue resistance was examined. ECC’s CO 2 uptake, static flexural behavior, flexural fatigue performance, and single fiber pull-out behavior were studied experimentally. Midspan deflection up to 3 million cycles under fatigue load, fatigue stress-life relationship, and failure mechanism for carbonation-cured and air-cured ECC were investigated. Carbonation curing was found to significantly improved the fatigue life of ECC and lowered the midspan deflection under the same stress. Further, CO 2 -cured ECC can achieve >20% CO 2 uptake per cement mass after 24-hour carbonation curing. Carbonation curing increased ECC’s flexural strength by 32% and promoted crack width control capability, with maximum post-fatigue crack width reduced from 148 μm to 76 μm. As a result, the positive impact of carbonation curing on the fatigue behavior of ECC simultaneously lowers the embodied and operational carbon of ECC structural members subjected to fatigue loading during service.
Electrochemical Concentration Cell (ECC) ozone instruments depend on the quality of care exercised in their pre-flight preparation. The ozone-measuring project conducted at Goddard Space Flight Center's Wallops Flight Facility uses a number of mechanisms designed to inspect the ECC for anomalies that may interfere with the reception of valid ozone profiles. Complete electronic testing of the instrument, individually and when coupled to its radiosonde has led to exceptional monitoring of ozone for detecting long-term atmospheric changes. A number of factors are considered when preparing an ECC instrument for flight. These basically are specific calibrations of pump efficiency, volumetric flow rate, temperature of the air entering the pump, and background current. The concentration of the potassium iodide solution is also important. Wallops is the only site using a UV photometer (Dasibi) to compare ECC ozone output at various concentrations of ozone that allows adjustment to be made to offsets that may appear in the balloon-borne instrument prior to release. All of the above procedures allow identification of potential problems before release of the ECC instrument. Procedures followed at Wallops also are employed in Brazil, and Ascension Island where NASA has cooperative agreements in place to obtain ozonesondes data. All ECC instruments are prepared 3-4 weeks prior to the day of observation. We will briefly describe the instrumental tests employed. These tests have included simultaneous dual observations to compare the effect of different solution concentrations, comparison of sensors of different manufacturers, and comparisons with surface- and space-based instrumentation such as the Dobson Spectrophotometer and satellites. Vertical profiles of ozone from Arctic, mid-latitudes, and Antarctica will be discussed. Although not unusual, the data reveals ozone structure that correlate well with typical atmospheric temperatures and possibly relative humidity. Finally, vertical ozone distribution, compared with remotely measured ozone from lidar and satellite, will be discussed. Specific comparisons between ECC and HALOE measurements, integrated ECC total ozone overburden with the EP-TOMS and the Dobson, as well as comparisons with lidar are discussed. Results show agreement and some disagreement between the in situ measurements of the ECC and the remote instruments. We postulate reasons for the differences, or biases, which in spite of the excellent ECC quality control during pre-flight preparation and data analysis processes, may be due to uncertainties in both measuring systems.
eCC++ is a new compiler construction framework for embedding domain-specific programming languages within C++. That is, the host language is C++, the guest language is the DSL to be embedded in C++, and eCC++ is the tool that enables the embedding. The eCC++ framework is composed of three main components: a front-end, an API for program verification based on a functional and declarative intermediate representation (IR), and a Multi-Level Intermediate Representation (MLIR) code generator. The eCC++ front-end consists of a library of C++ classes and operators that can be used to define the guest language. Guest sources are compiled with any standard C++ compiler, and when run, the resulting executable generates an eCC++ IR representation of the program, which can be verified within the eCC++ framework. Finally, eCC++ allows for high-level and domain-specific optimizations before generating MLIR. In summary, eCC++ aims to act as a generic front-end that enables embedding guest languages into C++, and provides necessary compiler technology for program verification, targeting the existing capabilities in the MLIR infrastructure. The paper evaluates the eCC++ expressiveness and usability describing the process of embedding GraphIt, a high-performance graph language in C++.
The ECC background current was identified as the removal of residual tri-iodide (iodine) as the cell approaches equilibrium. The altitude dependence of this source of the background current is expected to be only slowly changed in the troposphere with a more rapid decrease in the stratosphere. Oxygen does not play a role in the background current except in the unlikely situation where the electrodes have had all forms of iodine removed from them and the electrodes have not re-equilibrated with the sonde solutions before use. A solution mass transport parameter in the ECC was identified and its altitude dependence determined. The mass transport of tri-iodide dominates in the chemical transduction of ozone to electrical signal. The effect of the mass transport on the ECC background current is predicted. An electrochemical model of the ECC has been developed to predict the response of the ECC to various ozone vertical profiles. The model corresponds very closely to the performance of the ECC in the laboratory. Based on this model, an ECC with no background current is predicted to give total ozone values within 1% of the correct value, although the vertical profile may be in error by as much as + or - 15%.
Engineered Cementitious Composites (ECC) have superior properties with high tensile ductility and tight crack width compared to conventional concrete. The properties of ECC are significantly influenced by the material composition which can be tailored to enhance the sustainability of ECC. Towards this goal, recycled crumb rubber (CR) and silica fume (SF) were used to tailor the properties of a polypropylene-fiber reinforced ECC with a low carbon binder based on limestone calcined clay cement (LC3) in this study. Crumb rubber was found to be effective in enhancing strain-hardening performance and reducing the width of the multiple microcracks. However, a loss of compressive strength was accompanied by an increasing amount of CR. While silica fume or lower w/b ratio enhanced the compressive strength, the crack width of ECC increased at higher SF content or lower w/b. The underlying mechanisms of these trends were traced to the alteration of the matrix fracture toughness and fiber/matrix interfacial bond. Rubber particle bridging was found to contribute to crack width control. Finally, the combined use of the LC3 green binder and CR led to a lowering of the embodied and operational carbon footprint of ECC.
Traditional PVA fiber-reinforced Engineered Cementitious Composites (ECC) show high tensile ductility and superior durability with tight crack width, but the high cost and embodied carbon can hinder its wider application in infrastructures. The objective of this study is to develop a better understanding of the fresh and hardened properties of an ECC that employs a lower embodied-carbon binder, Limestone Calcined Clay Cement (LC3), and lower-cost PP fiber that is widely available. Specifically, the interrelations between material processing, microstructure, and composite properties were studied experimentally. The results showed that ECC with high tensile ductility up to 9% tensile strain and tight crack width with 50 μm at 2% tensile strain can be achieved. It was found that a matrix paste with higher viscosity generally enhanced fiber dispersion uniformity and robustness in tensile strain-hardening. The paste viscosity is increased when OPC is replaced by LC3 and can be tuned with superplasticizer content. Larger maximum flaw size leads to lower first crack strength, beneficial for microcrack initiation and multiple cracking. This study generates fundamental knowledge linking processing-microstructure-performance of PP-LC3-ECC. This class of low embodied carbon ECC with tight crack width is expected to contribute to reducing the carbon footprint of the built environment.
The electrochemical concentration cell (ECC) ozonesonde has been the main instrument for in situ profiling of ozone worldwide; yet, some details of its operation, which contribute to the ozone uncertainty budget, are not well understood. Here, we investigate the time response of the chemical reactions inside the ECC and how corrections can be used to remove some systematic biases. The analysis is based on the understanding that two reaction pathways involving ozone occur inside the ECC that generate electrical currents on two very different timescales. The main fast-reaction pathway with a time constant of about 20 s is due the conversion of iodide to molecular iodine and the generation of two free electrons per ozone molecule. A secondary slow-reaction pathway involving the buffer generates an excess current of about 2 %–10 % with a time constant of about 25 min. This excess current can be interpreted as what has conventionally been considered the “background current”. This contribution can be calculated and removed from the measured current instead of the background current. Here we provide an algorithm to calculate and remove the contribution of the slow-reaction pathway and to correct for the time lag of the fast-reaction pathway. This processing algorithm has been applied to ozonesonde profiles at Costa Rica and during the Central Equatorial Pacific Experiment (CEPEX) as well as to laboratory experiments evaluating the performance of ECC ozonesondes. At Costa Rica, where a 1 % KI, 1/10th buffer solution is used, there is no change in the derived total ozone column; however, in the upper troposphere and lower stratosphere, average reported ozone concentrations increase by up to 7 % and above 30 km decrease by up to 7 %. During CEPEX, where a 1 % KI, full-buffer solution was used, ozone concentrations are increased mostly in the upper troposphere, with no change near the top of the profile. In the laboratory measurements, the processing algorithms have been applied to measurements using the majority of current sensing solutions and using only the stronger pump efficiency correction reported by Johnson et al. (2002). This improves the accuracy of the ECC sonde ozone profiles, especially for low ozone concentrations or large ozone gradients and removes systematic biases relative to the reference instruments. In the surface layer, operational procedures prior to launch, in particular the use of filters, influence how typical gradients above the surface are detected. The correction algorithm may report gradients that are steeper than originally reported, but their uncertainty is strongly influenced by the prelaunch procedures.
The reliability of the Electrochemical Concentration Cell (ECC) ozonesonde depends on the care exercised in preparing the instrument for use. Although the ECC can be quickly prepared and flown, generally within less then one day if necessary, it is best to prepare the instrument at least one week prior to use, and as our tests have confirmed even 2-3 weeks prior to use may actually be better. There are a number of factors that must be considered when preparing an ECC. These basically are the pump efficiency, volumetric flow rate, temperature of the air entering the pump, and the background current. Also of importance is the concentration of the potassium iodide solution. Tests conducted at Wallops Island (38 N) has enabled us to identify potential problem areas and ways to avoid them. The calibration and pre-flight preparation methods will be discussed. The method of calibrating the ECC also is used at Ascension Island (8 S) and Natal, Brazil (5 S). Comparisons between vertical profiles of the ECC instrument and satellites will be reviewed as well as comparison with ground based instruments, such as, the Dobson Spectrophotometer and hand held Microtops photometers.
The Electron-Ion Collider (EIC) is a cutting-edge accelerator facility that will study the nature of the “glue” that binds the building blocks of the visible matter in the universe. The proposed experiment will be realized at Brookhaven National Laboratory in approximately 10 years from now, with detector design and R&D currently ongoing. Notably, EIC is one of the first large-scale facilities to leverage Artificial Intelligence (AI) already starting from the design and R&D phases. The EIC Comprehensive Chromodynamics Experiment (ECCE) is a consortium that proposed a detector design based on a 1.5 T solenoid. The EIC detector proposal review concluded that the ECCE design will serve as the reference design for an EIC detector. Herein we describe a comprehensive optimization of the ECCE tracker using AI. The work required a complex parametrization of the simulated detector system. Herein our approach dealt with an optimization problem in a multidimensional design space driven by multiple objectives that encode the detector performance, while satisfying several mechanical constraints. We describe our strategy and show results obtained for the ECCE tracking system. The AI-assisted design is agnostic to the simulation framework and can be extended to other sub-detectors or to a system of sub-detectors to further optimize the performance of the EIC detector.
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been recommended as a reference design for the proposed Electron-Ion Collider (EIC) program. Here, this paper presents simulation studies of exclusive J/$\psi$ detection and selected physics impact results in EIC using the projected ECCE detector concept. Exclusive quarkonium photoproduction is one of the most popular processes in EIC, which has a large cross section and a simple final state. Due to the gluonic nature of the exchange Pomeron, this process can be related to the gluon distributions in the nucleus. Preliminary results estimate the excellent statistics benefited from the large cross section of J/$\psi$ photoproduction and superior performance of ECCE detector concept. The precise measurement of exclusive J/$\psi$ photoproduction at EIC will help us to more deeply understand nuclear gluon distributions, near threshold production mechanism and nucleon mass structure.
The recently approved Electron-Ion Collider (EIC) will provide a unique new opportunity for searches of charged lepton flavor violation (CLFV) and other new physics scenarios. In contrast to the e ↔ μ CLFV transition for which very stringent limits exist, there is still a relatively large discovery space for the e → τ CLFV transition, potentially to be explored by the EIC. Here, with the latest detector design of ECCE (EIC Comprehensive Chromodynamics Experiment) and projected integral luminosity of the EIC, we find the τ-leptons created in the DIS process ep → τX are expected to be identified with high efficiency. A first ECCE simulation study, restricted to the 3-prong τ-decay mode and with limited statistics for the Standard Model backgrounds, estimates that the EIC will be able to improve the current exclusion limit on e → τ CLFV by an order of magnitude. As a result, the very high vertex resolution of the ECCE detector configuration plays a critical role in τ identification.
The EIC Comprehensive Chromodynamics Experiment (ECCE) detector has been designed to address the full scope of the proposed Electron Ion Collider (EIC) physics program as presented by the National Academy of Science and provide a deeper understanding of the quark-gluon structure of matter. To accomplish this, the ECCE detector offers nearly acceptance and energy coverage along with excellent tracking and particle identification. The ECCE detector was designed to be built within the budget envelope set out by the EIC project while simultaneously managing cost and schedule risks. Finally, this detector concept has been selected to be the basis for the EIC project detector.
Here, we performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in pythia6 and geant4 simulated e+p collisions at 18 GeV on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector configuration. Typical DIS kinematics were selected, most notably Q 2 >1 GeV 2 , and cover the x range from 10 -4 to 1. The single spin asymmetries were extracted as a function of x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton, and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. They are obtained in azimuthal moments in combinations of the azimuthal angles of the hadron transverse momentum and transverse spin of the nucleon relative to the lepton scattering plane. In order to extract asymmetries, the initially unpolarized MonteCarlo was re-weighted in the true kinematic variables, hadron types and parton flavors based on global fits of fixed target SIDIS experiments and e + e – annihilation data. The expected statistical precision of such measurements is extrapolated to 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. Similar neutron information is obtained by comparing the ECCE e+p pseudo-data with the same from the EIC Yellow Report and scaling the corresponding Yellow Report e+ 3 He pseudo-data uncertainties accordingly. The impact on the knowledge of the Sivers functions, transversity and tensor charges, and the Collins function has then been evaluated in the same phenomenological extractions as in the Yellow Report. Finally, the impact is found to be comparable to that obtained with the parametrized Yellow Report detector and shows that the ECCE detector configuration can fulfill the physics goals on these quantities.
The proposed Electron-Ion Collider (EIC) will operate high-energy high-luminosity electron+proton and electron+nucleus collisions to solve several unresolved fundamental questions. Due to their large masses (mc,b > ΛQCD), heavy quarks and their hadron products are ideal probes to study the nucleon/nuclear parton distribution functions in the high Bjorken-x (xBJ > 0.1) region and explore the hadronization process within the unconstrained kinematic region. Recently, the Electron-Ion Collider Comprehensive Chromodynamics Experiment (ECCE) consortium detector conceptual design has been selected as the reference design for the EIC project detector. The precise momentum and spatial resolutions provided by the ECCE tracking detector enable a series of open heavy flavor and quarkonia measurements. The physics projections of these proposed heavy flavor measurements in simulation studies using the ECCE detector design will be presented.
Using Dobson spectrophotometer measurements of total ozone as a comparison, an analysis of the electrochemical concentration cell (ECC) ozonesonde's measurement accuracy is presented. Days of conjunctive ECC-Dobson observations (from 1970 to 1976 at Wallops Flight Center) provide a set of 123 pairs of total ozone values. Sample set statistics are generated with means and standard deviations of total ozone values and differences being noted. An in-depth study of factors such as time assumptions used in calculating residual ozone, and other possible sources of errors are examined. A study of ECC ozone profiles is also presented with an evaluation of sonde measurement of seasonal trends, altitude or peak ozone concentration, and other important ozone parameters. Short-period changes in total ozone using Dobson data during the observational period are also described.
The ECC ozonesonde sampling behavior was examined at pressures ranging from 60 to 6 hPa with the objective of evaluating uncertainties in high altitude ozone data caused by variations in pumping efficiency. The averaged pump efficiency correction curve for a 43 sample set of 3A type ECC pumps showed a 2-3% bias from the curve provided by the manufacturer. In addition, random pump to pump variations (2 sigma) + or - were 5% at 6 hPa. These values probably represent minimum errors since the pumps were from the same production batch. A seven sample set of the newer 4A type ECC pumps was examined, with similar findings as for the 3A types.